• Title/Summary/Keyword: direct standardization

Search Result 99, Processing Time 0.026 seconds

Quantitative Determination of Ursolic acid from Prunellae Herba (하고초(夏枯草, Prunellae Herba)로부터 Ursolic acid의 함량 분석)

  • Kim, Ju-Sun;Lee, Kyong-Soon;Chang, Seung-Yeup;Won, Do-Hee;Kang, Sam-Sik
    • Korean Journal of Pharmacognosy
    • /
    • v.31 no.4
    • /
    • pp.416-420
    • /
    • 2000
  • Ursolic acid was isolated from Prunellae Herba (Prunella vulgaris var. lilacina) and identified by direct comparison with an authentic sample. A method of analysis for the evaluation of ursolic acid was developed based on extraction of ground plant material, followed by quantitative determination using capillary gas chromatography of the TMS derivative. Quantitative analysis by GC after derivatisation under mild silylating conditions showed 0.31% ursolic acid in 20 samples collected throughout regions of Korea while no ursolic acid was detected in the samples of the whole plant of Thesium chinense, a substitute for Prunellae Herba in southern regions of Korean peninsula.

  • PDF

Better Understanding of Direct Bone-Conduction Measurement: Comparison with Frequency-Specific Bone-Conduction Tones and Brainstem Responses

  • Kim, Yeoju;Han, Woojae;Park, Sihun;You, Sunghwa;Kwak, Chanbeom;Seo, Youngjoon;Lee, Jihyeon
    • Journal of Audiology & Otology
    • /
    • v.24 no.2
    • /
    • pp.85-90
    • /
    • 2020
  • Background and Objectives: The present study aimed to compare thresholds of direct bone-conduction (BC direct) with those of behaviorally measured BC pure-tone audiometry (PTA) and objectively measured BC auditory brainstem response (ABR) to confirm the clinical feasibility of their relationships. Subjects and Methods: Young adults with normal hearing participated in the study to determine the thresholds from three measurements at four testing frequencies. In the BC direct, the vibrator of a bone-anchored hearing aid softband was placed on the right mastoid of each subject. In both PTA and ABR, a B71 bone oscillator was placed on the subject's right mastoid. While the subject's thresholds of BC direct and BC PTA were determined with a clinically routine 5-dB step procedure, BC ABR was conducted to determine the individual's hearing sensitivity by a peak V of the waveform using tone-burst and click stimuli. Results: The BC direct showed a different pattern between low and high frequencies. Precisely, its thresholds were 13.25 and 12.25 dB HL at 0.5 and 1 kHz, respectively, but 19 and 19.75 dB HL at 2 and 4 kHz, respectively. A significant positive correlation existed between BC direct and PTA at 1 kHz, which was also correlated with ABR. Conclusions: Based on the current data, the thresholds of BC direct were similar to BC PTA at low frequencies and BC ABR at high frequencies. The thresholds of BC direct might be predictable at approximately 5 dB higher (or lower) than that in PTA, although a large data set is required for standardization.

Better Understanding of Direct Bone-Conduction Measurement: Comparison with Frequency-Specific Bone-Conduction Tones and Brainstem Responses

  • Kim, Yeoju;Han, Woojae;Park, Sihun;You, Sunghwa;Kwak, Chanbeom;Seo, Youngjoon;Lee, Jihyeon
    • Korean Journal of Audiology
    • /
    • v.24 no.2
    • /
    • pp.85-90
    • /
    • 2020
  • Background and Objectives: The present study aimed to compare thresholds of direct bone-conduction (BC direct) with those of behaviorally measured BC pure-tone audiometry (PTA) and objectively measured BC auditory brainstem response (ABR) to confirm the clinical feasibility of their relationships. Subjects and Methods: Young adults with normal hearing participated in the study to determine the thresholds from three measurements at four testing frequencies. In the BC direct, the vibrator of a bone-anchored hearing aid softband was placed on the right mastoid of each subject. In both PTA and ABR, a B71 bone oscillator was placed on the subject's right mastoid. While the subject's thresholds of BC direct and BC PTA were determined with a clinically routine 5-dB step procedure, BC ABR was conducted to determine the individual's hearing sensitivity by a peak V of the waveform using tone-burst and click stimuli. Results: The BC direct showed a different pattern between low and high frequencies. Precisely, its thresholds were 13.25 and 12.25 dB HL at 0.5 and 1 kHz, respectively, but 19 and 19.75 dB HL at 2 and 4 kHz, respectively. A significant positive correlation existed between BC direct and PTA at 1 kHz, which was also correlated with ABR. Conclusions: Based on the current data, the thresholds of BC direct were similar to BC PTA at low frequencies and BC ABR at high frequencies. The thresholds of BC direct might be predictable at approximately 5 dB higher (or lower) than that in PTA, although a large data set is required for standardization.

Improving Percentile Points of $x^2$ Distribution ($x^2$분포의 백분위수의 개선에 관한 연구)

  • 이희춘
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.16 no.28
    • /
    • pp.137-143
    • /
    • 1993
  • Generally there are three methods to derive an approximation formula: 1) approching standard normal distribution by appropriate changing variable 2) using standardization variable for expansion 3) deriving approximation formula by direct method. This paper present correction terms having the form of $C_{1/v^{n/2}}/{\;}+{\;}C_2{\;}(n=1,2)$ with respect to $x^2_{\alpha}(v)$ distribution (${\nu}{\;}{\leq}{\;}30$), which minimize the error by EDA method and least square method.

  • PDF

A Study on the Korea Industrial Standardization of ISO 9053 (공기흐름저항(ISO 9053)의 KS 규격 제정에 관한 연구)

  • Jung, Sung-Soo;Kook, Chan;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.984-985
    • /
    • 2004
  • The ISO 9053, acoustics - materials for acoustical applications - determination of airflow resistance was reviewed in order to make it as a KS and the basic contents were introduced. The measurement apparatus according to ISO 9053 were made and tested.

  • PDF

Structural Design and Analysis of Barge for Canal-Coastal Shipping (운하-연안 연계용 바아지의 구조 설계 및 해석)

  • Kim, Kyung-Su;Son, Choong-Yul;Kim, Sung-Joon
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.2 s.32
    • /
    • pp.26-34
    • /
    • 1999
  • Two types of barge, container and tanker vessels, are designed with specific dimensions for canal-coastal shipping in Kyung-In canal and Yellow Sea region. The principal dimensions of barges are determined by considering the environment of Kyung-In canal and Yellow Sea. The selection of structure type and structure type and strength confirmation is conducted by the technical rules of Korean Register of Shipping. For the structural analysis of designed barges, the semi-direct stuctural analysis is carried out with using MSC NASTRAN software. Applying identical dimensions to both vessels, the standardization of structural design and analysis procedure are introduced.

  • PDF

An evaluation of local waters productivity by operating types (운영형태별 수도사업 생산성 평가)

  • Kim, Shang-Moon;Lee, Ik-Gyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.325-334
    • /
    • 2011
  • Market Environment around water work industry is rapidly changing. ISO, International Organization for Standardization, announced the international water work service standard for comparison and evaluation between nations and businesses. And developed countries in water work are introducing market principle for growth of nation's water industry and reinforcement of its competitiveness. Also, some local governments entrusted their water utilities for improvement of competitiveness of water work. However, as some failure cases from overseas came out with emphasis, there are many refuting perspective about entrusted operation achievements of domestic water market. Hence, this paper evaluated competitiveness of domestic local water utilities from the perspective of productivity. After evaluating productivity using Malmquist productivity index, the authors compared and analyzed whether there is a difference of productivity between two different operating types by using Mann-Whitney test. As a result of analysis, it has shown that local water utilities achieved higher productivity at entrusted operation type rather than direct operation type. The local water utilities which chose entrusted operation had increased the productivity 13.9% on total factor productivity(TFP) during experimenting period, while the local water utilities which chose direct operation had increased 0.2%. The background of achieving this high productivity in entrusted operation was analyzed as a result of the higher technological effectiveness of a special water company. The result of this study can be referred when local government needs to decide on what operating types they will use.

A Study on Regional Medical Utilization Variation of Hospital Inpatients in Korea (우리나라 병원급 이상 의료기관 입원환자의 지역별 의료이용의 변이에 관한 연구)

  • Seo, Young-Suk;Lee, Kyung-Soo;Park, Jong-Ho;Kang, Sung-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.4
    • /
    • pp.1511-1519
    • /
    • 2010
  • The purpose of this study was to analyze regional medical utilization variation of hospital inpatients and to suggest policy for the allocation of medical service in Korea. We analyzed the relationship among medical service, city size, income level and regional medical utilization variation of hospital inpatients. The patient survey report of 2005 year in Ministry of Health and Welfare was used for this study. To adjust on the factor age and sex, we used direct standardization method. Findings of the research were summarized as follows ; First, standardization discharge rate on patient was different in the district. city type, and number of beds. Second, standardization length of stay of patient was different in region, city type, and number of beds.

The Analysis of Requirements for Safe Self-Operation (안전한 자율운항을 위한 요구 조건 분석)

  • Hong, Sung-Hwa
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.508-510
    • /
    • 2021
  • As the international standardization of 5G element technologies (e.g., 5G vertical satellite, direct communication functions between 5G NR (New Radio)-based devices) required not only in 5G verticals but also in autonomous navigation services is currently underway, it is expected to be utilized for autonomous navigation services while utilizing the economic size advantages of the scale of international standard-based solutions through 3GPP international standardization of marine communication services related to autonomous navigation vessels. In order to establish the ecosystem of ICT convergence market related to autonomous navigation vessels and to preoccupy core communication technology based on international standards, it is necessary to develop digital communication systems and gateways that have global compatibility, (2) secure core element technology based on next generation communication, and (3) promote international standardization for internationalization of related technologies. For this, data analysis and standard technology should be developed through service analysis by distance. Currently, the requirements for the operation of autonomous navigation vessels can be classified into three categories.

  • PDF

A Study on Improvement of Shear Test Apparatus in the Direct Shear Test Under Constant Pressure (정압(CD)조건 직접전단시험에 있어서 시험기의 개선에 관한 연구)

  • Kim Jae Young;Yang Tae Seon;Akihiko Ohshima
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2005
  • A direct shear test is classified roughly by one side simple shear test of confining horizontal displacement type and torsional shear test of non-confining one. Direct shear test that has been widely used so far has some problems with test apparatus, testing and the analysis, and in particular that its strength value is everestimated in sandy soils. Also, progressive failure of shearing process happens from shear apparatus restriction and because the shear strain and shear stress are erratic in specimen, we can not define the shear strain value. In the meantime, a simple shear test having advantage of direct shear test is an ideal test method that can get stress-strain relation on shear because it can deliver constant shearing deformation to specimen. However, simple shear test cannot be used practically, because its structure makes tester manufacturing difficult. This paper described a on outline of test apparatus, improvement of test method, and constant pressure test results based on the obtained from improved direct shear apparatus and the standardization of JGS soil testing method.