• Title/Summary/Keyword: direct solid analysis

Search Result 120, Processing Time 0.029 seconds

Evaluation of Exposure Dose and Working Hours for Near Surface Disposal Facility

  • Yeseul Cho;Hoseog Dho;Hyungoo Kang;Chunhyung Cho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.4
    • /
    • pp.511-521
    • /
    • 2022
  • Decommissioning of nuclear power plants generates a large amount of radioactive waste in a short period. Moreover, Radioactive waste has various forms including a large volumes of metal, concrete, and solid waste. The disposal of decommissioning waste using 200 L drums is inefficient in terms of economics, work efficiency, and radiation safety. Therefore, The Korea Radioactive Waste Agency is developing large containers for the packaging, transportation, and disposal of decommissioning waste. Assessing disposability considering the characteristics of the radioactive waste and facility, convenience of operation, and safety of workers is necessary. In this study, the exposure dose rate of workers during the disposal of new containers was evaluated using Monte Carlo N-Particle Transport code. Six normal and four abnormal scenarios were derived for the assessment of the dose rate in a near surface disposal facility operation. The results showed that the calculated dose rates in all normal scenarios were lower than the direct exposure dose limitation of workers in the safety analysis report. In abnormal scenarios, the work hours with dose rates below 20 mSv·y-1 were calculated. The results of this study will be useful in establishing the optimal radiation work conditions.

Solar Inverter with Grid Power Generation

  • Suchitra Khoje;Govind Wanje;Ramesh Mali
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.9
    • /
    • pp.162-165
    • /
    • 2023
  • Power can be generated from either renewable or non-renewable sources. Renewable sources are liked to maintain a strategic distance from contamination emanation and rely on upon fossil energizes which is decreasing day by day. The proposed sun powered vitality transformation unit comprises of a sun oriented exhibit, Bidirectional DC-DC converter, single stage inverter and AC. The inverter changes over DC control from the PV board into AC power and offered it to the heap which is associated with the lattice. The photovoltaic sun powered vitality (PV) is the most direct approach to change over sunlight based radiation into power and depends on the photovoltaic impact. The most extreme power point following of the PV yield for all daylight conditions is a key to keep the yield control per unit cost low for fruitful PV applications. Framework associated PV frameworks dependably have an association with people in general power matrix by means of an appropriate inverter in light of the fact that a PV module conveys just dc power. This project presents the new design, Development and Performance Analysis of a Grid Connected PV Inverter. Demonstrate that the proposed framework can lessen the Energy Consumption radically from the power board and give a solid support to the Grid.

Studies in Iron Manufacture Technology through Analysis of Iron Artifact in Han River Basin during the Proto-Three Kingdoms

  • Kim, Soo-Ki
    • Conservation and Restoration of Cultural Heritage
    • /
    • v.1 no.1
    • /
    • pp.9-22
    • /
    • 2012
  • The most widely excavated iron artifacts used as weapons or farm tools from central southern regions of Korea were subjects of non-metallic inclusion analysis through metallographic examination, microhardness measurement, and scanning electron microscopy with energy dispersive X-ray spectroscopy. Through metallographic interpretation and study of the analyzed results, the steel manufacturing and iron smelting using heat processing in the iron artifacts excavated from the central southern region of the ancient Korean peninsula was studied, and the analysis of the non-metallic inclusions mixed within the metallic structures was interpreted as the ternary phase diagram of the oxide to infer the type of iron ores for the iron products and the temperature of the furnace used to smelt them. Most of the ancient forged iron artifacts showed $Al_2O_3/SiO_2$ with high $SiO_2$ contents and relatively low $Al_2O_3$ contents for iron ore, indicating t hat for $Al_2O_3$ below 5%, it is presumed that magnetic iron ores were reduced to bloom iron (sponge iron) with direct-reduction process for production. The temperature for extraction of wustite for $Al_2O_3$ below 1% was found to be $1,020{\sim}1,050^{\circ}C$. Considering the oxide ternary constitutional diagram of glassy inclusions, the steel-manufacturing temperature was presumed to have been near $1,150{\sim}1,280^{\circ}C$ in most cases, and minimum melting temperature of casting iron part excavated in Daeseong-ri. Gyeonggi was near $1,400^{\circ}C$, and it is thought that hypoeutectic cast iron of about 2.3% carbon was casted and fragility of cast iron was improved by decarburizing in solid state.

Exhaled Breath Analysis of Lung Cancer Patients Using a Metal Oxide Sensor

  • Yu, Joon-Boo;Byun, Hyung-Gi;Zhang, Sholin;Do, Seoung-Hun;Lim, Jeong-Ok;Huh, Jeung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.300-304
    • /
    • 2011
  • Exhaled breath gases include gases generated in the body. When there is disease in the body, exhalation can include gas components from the disease. If we can find these specific elements through analysis of the exhalation gases, this can be an effective way to diagnose the disease. The lung has a close relationship with exhalation. Lung cancer refers to malignant tumors which originate in the lungs. Exhalation from the lung causes direct jets of gas to be ejected through the mouth and nose, so by analyzing these jets it may be possible to diagnose lung cancer. In our study we attempt to diagnose lung cancer from patient's exhaled gases. Exhalation of lung cancer patients was analyzed using gas chromatography-mass spectroscopy(GC-MS) and the expiratory gas was also measured using a sensor system. The system was designed to use a metal oxide sensor and solid phase micro extraction(SPME) fiber. The GC-MS analysis of the healthy subject's and cancer patient's exhalation gases both showed the presence of decane in the breath of patients with lung cancer. In addition, the results from the sensor system showed significant difference between the lung cancer patients and the healthy subjects.

Elastoplastic FEM analysis of earthquake response for the field-bolt joints of a tower-crane mast

  • Ushio, Yoshitaka;Saruwatari, Tomoharu;Nagano, Yasuyuki
    • Advances in Computational Design
    • /
    • v.4 no.1
    • /
    • pp.53-72
    • /
    • 2019
  • Safety measures for tower cranes are extremely important among the seismic countermeasures at high-rise building construction sites. In particular, the collapse of a tower crane from a high position is a very serious catastrophe. An example of such an accident due to an earthquake is the case of the Taipei 101 Building (the author was the project director), which occurred on March 31, 2002. Failure of the bolted joints of the tower-crane mast was the direct cause of the collapse. Therefore, it is necessary to design for this eventuality and to take the necessary measures on construction sites. This can only be done by understanding the precise dynamic behavior of mast joints during an earthquake. Consequently, we created a new hybrid-element model (using beam, shell, and solid elements) that not only expressed the detailed behavior of the site joints of a tower-crane mast during an earthquake but also suppressed any increase in the total calculation time and revealed its behavior through computer simulations. Using the proposed structural model and simulation method, effective information for designing safe joints during earthquakes can be provided by considering workability (control of the bolt pretension axial force and other factors) and less construction cost. Notably, this analysis showed that the joint behavior of the initial pretension axial force of a bolt is considerably reduced after the axial force of the bolt exceeds the yield strength. A maximum decrease of 50% in the initial pretension axial force under the El Centro N-S Wave ($v_{max}=100cm/s$) was observed. Furthermore, this method can be applied to analyze the seismic responses of general temporary structures in construction sites.

Determination of Volatile Organic Compounds emitted from Municipal Solid Waste Landfill Site by Thermal Desorption-Cryofocusing-GC/FID/FPD (열탈착-저온농축-GC/FID/FPD에 의한 도시 생활폐기물 매립장에서 방출되는 휘발성 유기화합물의 측정에 관한 연구)

  • Kim, Man-Goo;Jung, Young-Rim;Seo, Young-Min;Nam, Sung-Hyun;Kwon, Young-Jin
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.274-285
    • /
    • 2001
  • In this study, the thermal desorption-cryofocusing-gas chromatographic(TD-C-GC) method was developed for determination of volatile organic compounds(VOCs) in ambient air and was applied at the municipal solid waste landfill sites. On-column cryofocusing was possible only with a 100 ml dewars bottle in TD-C-GC method with a stainless steel column. However, high operating pressure was needed for purging VOCs from the absorbent trap, which was able to solve by pressure programming with a electric pressure controller. By using both pressure and temperature programming brought increasing of resolution power in on-column cryofocusing method, but the high pressure caused a leakage of sample tube with repeated use. A loop cryofocusing devise was also developed and compared with the direct on-column method. In loop cryofocusing method, VOCs were concentrated on a 0.8mm i.d. loop which is located between the injector and separation column by using liquid nitrogen. In order to purge VOCs from the absorbent trap, only 0.4 psi of pressure was need in the loop cryofocusing method. Dual detection system was applied for the analysis of VOCs; a FID was used for hydrocarbons and a FPD was used for sulfur-containing compounds. Qualitative analysis was done by on-column cryofocusing GC-MS system. Among the large number of VOCs, toluene was the most abundant. Hydrogen sulfide, dimethyl sulfide, carbon disulfide, dimethyl disulfide and methyl propyl disulfide were detected at landfill site by FPD.

  • PDF

Design and Analysis of a Novel Methanol SOFC Combined System for Marine Applications Toward Future Green Shipping Goals

  • Duong Phan Anh;Ryu Bo Rim;Hokeun Kang
    • Journal of Navigation and Port Research
    • /
    • v.47 no.2
    • /
    • pp.106-119
    • /
    • 2023
  • Due to global decarbonization movement and tightening of maritime emissions restrictions, the shipping industry is going to switch to alternative fuels. Among candidates of alternative fuel, methanol is promising for decreasing SOx and CO2 emissions, resulting in minimum climate change and meeting the goal of green shipping. In this study, a novel combined system of direct methanol solid oxide fuel cells (SOFC), proton exchange membrane fuel cells (PEMFC), gas turbine (GT), and organic Rankine cycle (ORC) targeted for marine vessels was proposed. The SOFC is the main power generator of the system, whereas the GT and PEMFC could recover waste heat from the SOFC to generate useful power and increase waste heat utilizing efficiency of the system. Thermodynamics model of the combined system and each component were established and analyzed. Energy and exergy efficiencies of subsystems and the entire system were estimated with participation of the first and second laws of thermodynamics. The energy and exergy efficiencies of the overall multigeneration system were estimated to be 76.2% and 30.3%, respectively. The combination of GT and PEMFC increased the energy efficiency by 18.91% compared to the SOFC stand-alone system. By changing the methanol distribution ratio from 0.05 to 0.4, energy and exergy efficiencies decreased by 15.49% and 5.41%, respectively. During the starting up and maneuvering period of vessels, a quick response from the power supply system and propulsion plant is necessary. Utilization of PEMFC coupled with SOFC has remarkable meaning and benefits.

A Study on the Plasticity and Characteristics on Jump Suit Shown in the Modern Fashion (현대패션에 나타난 점프 슈트(Jump Suit)의 조형성과 특성)

  • Kim, Sun Young
    • Korean Journal of Human Ecology
    • /
    • v.23 no.3
    • /
    • pp.515-527
    • /
    • 2014
  • This study is intended to develop the creative and high value-added products as well as the development of diversity for jump suit for the future by analyzing the trend and feature shown in jump suit in the modern fashion. In the research methodology, the analysis was carried out over a total of 351 work pieces on jump suit among those presented in the collection of Paris, Milan, New York and London from 2006S/S to 2013F/W as well as literature review. The aesthetic features on suit jump design introduced in the modern fashion could be characterized as the following. First, both upper and lower garments are composed with a simple array of items and the stress was put on modernity feature through minimal expression technique. The feature of solid simplicity was also given with achromatic color or neutral monochrome. Second, the feminity image was emphasized with adoption of such highlighting items as detailed add-ons, tops, camisoles and blouses that stress the organically curved streamline including silhouette, material itself, crease and drape that enable the direct and indirect exposition of human body and the expression of smooth curve in human body. Third, jump suit revealed the multipurpose feature as item available for the diverse wear such as working habiliment, sports wear, uniform, office wear and evening wear, depending on the terms and conditions. Fourth, the deconstructive characteristic appeared through integration with various items, destruction of formative structure, non-structural shape, and ambiguity in wearing method.

Antitumor Components of the Cultured Mycelia of Lepiota procera (갓버섯의 항균 분석)

  • 김병각;심미자;김옥남;김하원;최응칠
    • Journal of Food Hygiene and Safety
    • /
    • v.4 no.2
    • /
    • pp.109-118
    • /
    • 1989
  • To find antitumor components in the cultured mycelia of Lepiota procera, the proteinpolysaccharide obtained from the mycelia was subjected to DEAE - Sephadex A-50 column chromatography and Sepharose-4B gel filtration. Of the fractions, the purified Fraction C1 was named lepiotan and examined for antitumor activity against the solid form of sarcoma 180 in ICR mice. The inhibition ratio of lepiotan was 64% at the dose of 10 mg/kg/day for 10days. The chemical analysis of lepiotan showed 60% polysaccharide and 21 % protein. The polysaccharide moiety was found to be a heteromannoglucan which consisted of 46.3% glucose, 40.2% mannose and 11.0% fucose. When the antitumor component, Fraction A, was examined for immunopotentiation activity, it was found to increase the number of plaques in hemolytic plaque assay and to restore the immunity in the tumor-bearing mice up to 89.7% of the normal level. Also the antitumor acitivity was suppressed by the treatment with carrageenan, an antimacrophage agent. These results indicate that the antitumor activity was exerted through immunopotentiation, but not through direct cytotoxicity against the tumor.

  • PDF

Fundamental Studies of Gas-jet Assisted Radio Frequency Glow Discharge Atomic Absorption Spectrometry (원자흡수법에 의한 Gas-Jet Assisted RF 글로우방전 시스템의 특성 연구)

  • Choi, Seong-Kyu;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.69-77
    • /
    • 1995
  • The instrumentation and operating characteristics of a gas-jet assisted radio frequency glow discharge atomic absorption spectrometry(RF-GDAAS) are studied. The roles of discharge power, pressure as well as gas flow rate on the sample loss rate and absorbance are described in this paper. Results show that the optimum discharge conditions depend on pressure and discharge power as well as on the gas flow rate. The gas flow rate plays as an important parameter in RF-GDAAS. Absorbance increases as the gas flow rate increase up to 600ml/min., and the optimum absorbance is obtained at the pressure of 3 mbar. The absorbance increases when the discharge power increases as expected, however, the instability of the system due to the heat might be the trade off factor. The linear calibration curves of Ni and Cr in stainless steel(BAS 461-468) and brass (KSS 1121-1126) are obtained with RF-GDAAS.

  • PDF