• Title/Summary/Keyword: direct reading instrument

Search Result 13, Processing Time 0.026 seconds

Comparative Analysis between Direct-reading Meter of PID and GC-FID using the Active Type Air Sampler for VOCs Measurement (직독식 측정기 PID와 능동식 시료채취기에 의한 GC-FID 정량분석법의 VOCs 농도 비교 연구)

  • Yeo, Jin-Hee;Choi, Kwang-Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.301-306
    • /
    • 2016
  • Objectives: Direct-reading instrument(Photoionization detectors, PID) and quantitative analysis using active type air sampling (Gas chromatography-flame ionization detector, GC-FID) were tested to evaluate their ability to detect volatile organic compounds(VOCs) in a semiconductor manufacturing plant. Methods: The organic compounds used were acetone and ethanol which are normally used as cleaning solutions in the semiconductor manufacturing. The evaluation was based on the preparation of test solutions of known acetone and ethanol concentration in a chamber($600{\times}600{\times}1150mm$). Samples were prepared that would be equivalent to 5~100 ppm for acetone and 10~ 200 ppm ethanol. GC-FID and PID were evaluated simultaneously. Quantitative analysis was performed after sampling and the direct-reading instrument was checked using real-time data logging. Results: Positive correlations between PID and GC-FID were found for acetone and ethanol at 0.04~2.4% for acetone(TLV: 500 ppm) and 0.1~8.3% for ethanol(TLV: 1000 ppm). When the sampling time was 15 min, concentration of test solution was the most similar between measurement methods. However, the longer the sampling time, the less similar the results. PID and GC-FID had similar exposure patterns. Conclusions: The results indicate that PID and GC-FID have similar exposure pattern and positive correlation for detection of acetone and ethanol. Therefore, PID can be used for exposure monitoring for VOCs in the semiconductor manufacturing industry. This study has significance in that it validates measuring occupational exposure using a portable device.

Feasibility Study of Laser Contact Angle Measurement for Nano-fiber Characterization (나노섬유의 특성분석을 위한 레이저 접촉각 측정기의 효율성 연구)

  • 신경인;안선훈;김성훈
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.5
    • /
    • pp.554-559
    • /
    • 2003
  • A newly developed contact angle measurement instrument by laser beam projection allows for rapid and direct determination of contact angles. The instrument may have a possibility to characterize newly developed nano-fibers. When the laser beam impinges on an edge of an interface of liquid and solid, projected beam were split across and made two straight lines on a tangent screen. From the result, it could measure the contact angle directly by reading the angle between two split beams. The purpose of this study was to prove reliability and reproducibility of the contact angle measurement instrument by laser beam projection compare to the conventional one by microscope through the comparative experiment and questionnaire. Test samples were selected by consideration of hydrophilic and hydrophobic, such as nylon 6 and polypropylene, respectively. The laser contact angle measurement has accurate, fast and convenient method to measure contact angle, and it can be a unique method to characterize nano-fibers.

A Comparison of PM10 Exposure Characteristics of Swine Farmers by Body Parts using Direct-reading Instrument (직독식 기기를 이용한 양돈작업자의 신체부위별 PM10 노출 특성 비교 연구)

  • Sin, Sojung;Kim, Hyocher;Kim, Kyung-ran;Seo, Mintae;Park, Sooin;Kim, Kyungmin;Kim, Kyungsu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.2
    • /
    • pp.159-166
    • /
    • 2019
  • Objectives: The purpose of this study was to evaluate the personal exposure to $PM_{10}$ by body parts for the development of dust monitoring wearable device for swine farmers. Methods: Tasks were classified by using motion pictures taken by action cameras attached to swine farmers. Concentrations of $PM_{10}$ were measured by attaching direct-reading instruments at the head, neck and waist of worker. Differences of $PM_{10}$ exposure between body parts were analyzed with linear regression. Results: We identified three tasks(vaccination, moving pigs, and manure treatment). $PM_{10}$ concentration during vaccination was the highest among the tasks, and the body part showing the highest concentration of $PM_{10}$ was the waist regardless of task. In all tasks, the closer distance between the body parts, the higher were the R-squared values(vaccination 0.4221, moving pigs 0.6990, and manure treatment 0.2164). Conclusions: We presumed that $PM_{10}$ concentrations were affected by the parts of the body in which they were measured. In order to develop swine farmer's wearable device for monitoring dust concentration in air, the determination of the positions of monitoring sensor to ensure accurate measurement is essential. Considering the results of this study, wearable sensor should be positioned at the waist.

Electrolytic Conductance Measurement using Four-Electrode Cell and Potentiometric Circuit (포텐티오메트릭 4-전극 용기에 의한 전도도 측정)

  • Jung-Kyoon Chon;Woon-kie Paik
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.2
    • /
    • pp.129-135
    • /
    • 1976
  • A direct-reading conductance measuring system using a potentiostatic circuit and a four-electrode conductance cell was devised. The difficulties with the traditional method of using the Wheatston bridge and a two-electrode cell due to the complicated nature of the electrochemical system, the double layer capacitance and the Faradaic impedance at the electrodes, etc., could be avoided in this method. The devised instrument proved to be convenient and suitable for precise measurements. The results of measured conductivities of KCl and HCl solutions are reported.

  • PDF

Preliminary Study on Effect of the Field Correlation Factor for Increasing of the Accuracy in a Direct Reading Instruments on Photoionization Detector for Total Volatile Organic Compounds (총휘발성유기화합물 측정 직독식장비 정확도 향상을 위한 현장보정계수 활용 연구)

  • Sungho Kim;Gwangyong Yi;Sujin Kim;Hae Dong Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.67-76
    • /
    • 2024
  • Objectives: Direct reading instruments (DRIs) are widely used by industrial hygienists and other experts for preliminary survey and identifying source locations in many industrial fields. Photoionization detectors (PIDs), which are a form of hand-held portable DRIs, have been used for a variety of airborne vaporized chemicals, especially evaporated hydrocarbon solvents. The benefits of PIDs are high sensitivity between each chemical, competitive price, and portability. With the goal of increasing the accuracy of logged PID concentrations, previous studies have performed tests for the assessment of single chemical compounds, not mixtures. The purpose of this preliminary study was to measure mixtures with a PID and charcoal tube at the same time and compare the accuracy between them. Methods: A chamber test was implemented with different mixtures of hydrocarbon chemicals (acetone, isopropyl alcohol, toluene, m-xylene) and levels in the range of 14 to 864 ppm. Three PIDs and charcoal tubes were connected to the chamber and measured the chemical mixtures simultaneously. A comparison of accuracy and the PID group of concentrations with manufacture correction factor (M_CF) and field correction factor (F_CF) applied was performed. Results: The accuracy of the PID concentrations data-logged from the PID did not meet the accuracy criteria except for the mixture level B and C logged from PID No. 2, which was 18% of all tests for meeting accuracy criteria. The mean and standard deviation (SD) of concentration (ppm) of the charcoal tube followed by each mixtures' level were 10.37±0.26, 155.33±5.28, 300.80±11.65, and 774.93±22.65, respectively. When applying F_CF into the PID concentrations, the accuracy increased by nearly 82%. However, in the case of M_CF, none met the accuracy criterion. Between the PID there were differences of logged concentrations. Conclusions: In this preliminary study, the concentration of a logged PID with F_CF applied was a better way to increase accuracy compared to applying M_CF. We suggest that additional research is necessary to consider environmental factors such as temperature and humidity.

Exposure to Dust and Organic Gas during Chicken Entrance and Shipment Tasks in Poultry Farms (양계장에서 입식 및 출하작업시 분진과 가스상 물질의 노출 측정 조사)

  • Kim, Kyung-Ran;Kim, Hyocher;Lee, Kyungsuk;Chae, Hye-Seon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.471-477
    • /
    • 2014
  • Objectives: This study was conducted to evaluate area exposure of airborne dust and organic gas during entrance and shipment of chicken in poultry farms Methods: Total dust was measured with NIOSH method 0500. The volume of distributed dust and organic gas(Ammonia, TVOC, Hydrogen Sulfide) were measured using direct reading instrument. Results: The range of concentrations of total dust in area sample was $0.07{\sim}4.91mg/m^3$ during the entrance of chicks and $4.37{\sim}9.4mg/m^3$ during shipment respectively. Concentration of ammonia reached approximately 9 ppm during shipment. There was a difference of concentration of total dust in the area sample between shipment and entrance tasks. Conclusions: It was found that the development of a special intervention program by type of task should be considered for reducing respiratory health effects among poultry farmers.

Ammonia and Hydrogen Sulfide Monitoring in Broiler Barns and Cattle Barns (계사 및 우사 내 암모니아 및 황화수소 노출농도 평가)

  • Park, Jihoon;Seok, Jiwon;Lee, Sangah;Kwon, Ohhun;Lee, Kyungsuk;Heo, Yong;Yoon, Chungsik
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.5
    • /
    • pp.277-288
    • /
    • 2015
  • Objectives: There are many hazardous agents at livestock farms. In particular, gases can be detrimental to both workers and animals. This study evaluated ammonia and hydrogen sulfide concentrations in broiler hen barns and beef cattle barns according to sampling location and height. Methods: Three broiler hen barns and three beef cattle barns were selected for gas monitoring in this study. Ammonia and hydrogen sulfide concentrations were measured using a direct-reading instrument which could measure the target gases simultaneously. Gas monitoring was conducted at human breathing height and animal breathing height at three points in each livestock farm. Results: Ammonia concentrations at the broiler hen barns ranged from 3.3 to 12.5 ppm by sampling location and height, but hydrogen sulfide was not detected. In the beef cattle barns, ammonia ranged from 3.1 to 16.3 ppm and low concentrations of hydrogen sulfide were detected at some animal breathing heights. The gas concentrations detected at each livestock farm were significantly higher in the animal breathing zones than in human breathing zones (p<0.0001). Conclusions: We found a difference in gas concentrations between human breathing zones and animal breathing zones. Gas monitoring should be conducted to improve the related environment considering both workers' and animals' health and safety.

Exposure to Ozone and TVOCs during Shipyard Welding and the Adequacy of RPE (조선소 용접작업 중 오존 및 TVOCs의 노출평가와 사용 호흡보호구의 적합성)

  • Han, Don-Hee;Kim, Dong Hwan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.2
    • /
    • pp.200-210
    • /
    • 2018
  • Objectives: The purpose of this study is to assess the exposure to ozone and total volatile organic compounds(TVOCs) generated during welding work at a shipyard and recommend respiratory protective equipment(RPE) adequate against these hazards. Method: Ozone was collected for about 30 minutes at two-minutes intervals using a direct reading instrument, specifically an ozone analyzer(Serinus 10, Ecotech, Australia). TVOCs were collected for about 30 minutes at three-minute intervals using a portable GC (Alpha 115, Synspec BV, the Netherlands), and were determined simultaneously by area sampling at the welding plume closest to the welder's breathing zone. The total measurements were 162 for ozone($CO_2$ welding 47, TIG 60, stick 55), and 136 for TVOCs($CO_2$ 65, TIG 50, stick 21). Based on these measurements, a literature survey was conducted to assess the adequacy of RPE. Results: Relative to Korean OEL, measurements above STEL 0.2 ppm were 23.4% for $CO_2$, 63.3% for TIG and 14.5% for stick welding. There were significant differences(p=<0.0001) among welding types. Compared with ACGIH peak exposure of 0.4 ppm for ozone, which is not applied in Korea, $CO_2$ welding exceeded it by 10.6%, TIG by 40.0% and stick by 7.3%. Although it was not feasible to compare them directly since there are no Korean OEL, TVOCs had very high levels similar to the concentrations before moving into a new apartment and about 10-20 times the indoor air quality recommendations for some individual measurements. Conclusions: As ozone removal RPE has been recommended in welding environments for a long time(Lunau, 1967), this fact was demonstrated based on the results of the on-site work environment measurements(ozone and TVOCs). In conclusion, for all welding at a shipyard, gas/vapor and particulate combination RPE are recommended. If this is not possible, it should at least be present for TIG welding.

An Analysis of the Attitudes toward Science and Support for Scientific Activities of Scientific Gifted and General Students' Parents in Elementary Schools (초등학교 과학 영재와 일반 학생 부모의 과학에 대한 태도 및 과학 활동 지원 정도 분석 연구)

  • Lee, Soo-Jin;Shim, Bong-Sup;Jeong, Jin-Su;Kang, Sang-Sun;Paik, Seoung-Hey;Lee, Kyung-Hwa;Chun, Jae-Sun
    • Journal of Korean Elementary Science Education
    • /
    • v.27 no.3
    • /
    • pp.296-306
    • /
    • 2008
  • The purpose of this study was to analyze the attitudes toward science and support for scientific activities of the scientific gifted students' parents and the general students' parents in elementary school. The objects of the study were 99 scientific gifted students and their parents and 433 general elementary school students and their parents. The instruments for the measurement of attitudes toward science included three scales: cognition :About value of science, affection toward science and science learning, and cognitive participation in scientific activities. The instrument to measure parents' support for scientific activities included two scales: indirect support and direct support. The results of the study showed that the attitudes toward science of scientific gifted elementary students' parents were more positive than the attitudes toward science of general elementary students' parents. Also the gifted elementary students' parents supported many more scientific activities for their children with various methods than the general elementary students' parents. Their preferring support methods for scientific activities included 16 items including the collection of information about science education, the record of TV science programs, purchase of scientific books, subscription of periodical publication about science, preparing material for scientific activities, and reading scientific book with children.

  • PDF

The Comparison Study on the Concentration of $NO_{2}$, HCHO by Passive Sampler and Direct Reading Instrument (확산형 시료 채취기와 직독식 기기에 의한 이산화질소와 포름알데히드 농도의 비교)

  • Kim, Gyeong-Jin;Park, Ji-Yeon;Kim, Hyeong-A;An, Gyu-Dong
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.11a
    • /
    • pp.106-109
    • /
    • 2005
  • 확산형 시료 채취기와 직독식 기기(공정시험법, Nitrogen Oxides Analyzer Model; EC 9841, Ecotech, Australia)에 의한 $NO_2$, 농도를 비교하고, 능동시료채취기(공정시험법)와 확산형포집기에 의한 HCHO(포름알데히드) 농도를 비교하기 위해 서울 ${\cdot}$ 경기 또는 대전, 충남 ${\cdot}$ 북지역에 소재한 11개 시설(종합병원 4곳, 노인 병원 1곳, 보건소 1곳, 복지관 3곳, 보육시설 2곳)을 대상으로 수행하였다. 1. 포름알데히드의능동 포집법(공정시험법)에 의한 시료(n=87)의 평균농도는 $11.44{\pm}11.07ppb$이고, 확산형 시료 채취기 의한 시료(n=40)의 평균농도는 $11.91{\pm}7.37ppb$으로 비슷한 값이 나왔고, 통계적으로 유의하지 않았다(p=0.806). 2. 포름알데히드 능동 포집법에 의한 농도와 확산형 시료 채취기에 의한 농도와의 상관계수 r=0.404(p=0.037)로 나타나 이 두 가지의 방법은 특정시간 포름알데히드 측정에 사용하여도 어느 정도 비교하기에는 적합할 것으로 생각된다. 3. 이산화질소의 노출정도는 직독식 기기(공정시험방법)와 확산형 시료 채취기로 각각 1시간 (오전, 오후 각각 2회), 8시간 측정하였다. 공정시험방법(n=61)에 의한 1시간-시료 평균농도는$44.48{\pm}37.96ppb$이고, 확산형 시료 채취기(n=61)에 의한 1시간-시료 평균농도는 $3.58{\pm}2.07ppb$으로 통계적으로 유의하였다(p=0.000). 직독식 기기(n=61)에 의한 8시간-시료 평균농도는 $34.85{\pm}22.83ppb$이고, 확산형 시료 채취기(n=61)에 의한 8시간-시료 평균농도 $8.32{\pm}4.44ppb$으로 통계적으로도 유의하였다(p=0.000). 4. 이산화질소를 직독식 기기(공정시험방법)와 확산형 시료 채취기로 측정한 1시간-시료 농도의 상관계수 r=0.253(p=0.268)이고 8시간-시료 일 때 상관계수 r=0.367(p=0.102)로 나타나 확산형 시료 채취기를 직독식 기기(공정시험방법) 대체 사용방법으로 이용하기에는 적합하지 않다고 생각된다.

  • PDF