Adhesion of clay to metal surface; Normal and tangential measurement

  • Basmenj, Amir Khabbazi;Ghafoori, Mohammad;Cheshomi, Akbar;Azandariani, Younes Karami
    • Geomechanics and Engineering
    • /
    • v.10 no.2
    • /
    • pp.125-135
    • /
    • 2016
  • Adhesion in geotechnical engineering is the interaction between cohesive soil and a solid surface which can cause clogging in mechanized tunnelling through clayey formations. Normal piston pull out and modified direct shear tests were performed on clayey soil samples to determine which type of adhesion stress, normal or tangential, could be most effectively measured. Measured values for normal adhesion ranged from 0.9 to 18 kPa. The range of tangential adhesion was 2.4 to 10 kPa. The results indicate normal adhesion results were more accurate than those for the modified direct shear test that measure tangential adhesion. Direct shear test on identical samples did not show any correlation between measured cohesion and normal adhesion values. Normal adhesion values have shown significantly meaningful variation with consistency index and so are compatible with the base of field clogging assessment criteria. But tangential adhesion and cohesion were not compatible with these assessment criteria.

Development of Hybrid Fiber Reinforced Polymer Reinforcing Bars and Evaluation of the Bond Properties (하이브리드 FRP 보강근의 형상개발과 부착성능 평가)

  • Park, Ji-Sun;Park, Young-Hwan;You, Young-Jun;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.629-632
    • /
    • 2006
  • The various rib geometry of hybrid fiber reinforced polymer (FRP) reinforcing bars were analyzed by finite element method. From the analysis result, two types of hybrid FRP reinforcing bars such as spiral and cross type with the same dimension of rib geometry were fabricated in this study. To evaluate the bond properties of them, direct pull-out test was performed. All testing procedures including specimens preparation, set-up of test equipments and measuring devices were made in accordance with the recommendations of CSA Standard S806-02. From the test results, it was found that cross type hybrid FRP reinforcing bars showed the highest bond strength than that of the others due to the higher relative rib area.

  • PDF

Comparison of Bond-Slip Behavior and Design Criteria of High Strength Lightweight Concrete with Compressive Strength 50 MPa and Unit Weight 16 kN/m3 (압축강도 50 MPa, 단위중량 16 kN/m3 고강도 경량 콘크리트 부착-슬립 거동의 설계기준과의 비교)

  • Lee, Dong-Kyun;Lee, Do-Kyung;Oh, Jun-Hwan;Yoo, Sung-Won
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.2
    • /
    • pp.168-175
    • /
    • 2022
  • With the recent development of nanotechnology, its application in the field of construction materials is continuously increasing. However, until now, studies on the bond characteristics of concrete and rebar for applying high-strength lightweight concrete with a compressive strength of 50 MPa and a unit weight of 16 kN/m3 to structural members are lacking. Therefore, in this paper, 81 specimens of high-strength lightweight concrete with a compressive strength of 50 MPa and a unit weight of about 16 kN/m3 were fabricated and a direct pull-out tests were performed. The design code for the bond strength of ACI-408R and the experimental results are shown to be relatively similar, and as a result of the CEB-FIP and modified CMR bond behavior models through statistical analysis, it is shown to describe well on average.

An Experimental Study on the Bond Failure Behavior between Parent Concrete and CFM (콘크리트와 탄소섬유메쉬의 부착파괴 거동에 관한 실험적 연구)

  • 오재혁;성수용;한병찬;윤현도;서수연;김태용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.965-970
    • /
    • 2002
  • The strengthening of concrete structures in situ with externally bonded carbon fiber is increasingly being used for repair and rehabilitation of existing structures. Carbon fiber is attractive for this application due to its good tensile strength, resistances to corrosion, and low weight. Generally bond strength and behavior between concrete and carbon fiber mesh(CFM) is very important, because of the enhanced bond of CFM. Therefore if bond strength is sufficient, it will be expected to enhance reinforcement effect. If insufficient, reinforcement effect can not be enhanced because of bond failure between concrete and CFM. This study is to investigate the bond strength of CFM to the concrete using direct pull-out test and tensile-shear test. The key variables of the experiment are the location of clip, number of clips and thickness of cover mortar. The general results indicate that the clip anchorage technique for increasing bond strength with CFM appear to be effective to maintain the good post-failure behavior.

  • PDF

Consideration on Bond Behavior of FRP Rebars with Various Surface Treatments and Deformation Shapes (FRP 보강근의 표면처리 및 돌기형상에 따른 부착거동 특성 비교)

  • You, Young-Jun;Park, Ji-Sun;Park, Young-Hwan;Kim, Keung-Hwan;Kim, Hyeong-Yeol;You, Young-Chan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.122-125
    • /
    • 2006
  • This paper presents the comparison of the bond behavior of various FRP rebars. A total of 9 specimens including steel reinforcement were tested through direct pull-out test procedure. The test results have revealed that the bond behavior was affected by the deformation shapes and surface treatments. The newly proposed FRP rebar by KICT showed good bond strength and ductile behavior after failure.

  • PDF

Bond between Carbon Fibers Sheet and Concrete (탄소섬유쉬트와 콘크리트의 부착)

  • 최근도;류화성;최기선;이한승;유영찬;김긍환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1019-1024
    • /
    • 2000
  • Carbon fiber sheet has been widely used for the strengthening of the concrete buildings structures due to its excellent physical properties such as high strength, lightness and high durability. Bond strength or behavior, on the other, hands, between carbon fiber sheet and concrete is very important in strengthening the concrete member using CFS. Also the bond failure mechanism between CFS and concrete should be fully verified and understood. This study is to investigate the bond strength of CFS to th concrete by the direct pull-out test and the tensile-shear test methods. From the tests, the average bond stress, $$\tau$_{y}$ and the effective bond length, $$\ell$_{u}$ are acquired.

Geogrid Reinforced Decomposed Granite Soil (화강풍화토의 지오그리드보강 특성연구)

  • 주재우;박종범;김병욱
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.4
    • /
    • pp.173-182
    • /
    • 2001
  • 보강토공법이란 다양한 보강재를 흙속에 삽입하여 흙이 갖지 못하는 인장력을 보충함으로써 구조물을 안정화시키는 공법이다. 그리고 기존공법에 비해 경제적 구조물로 인식되고 있으며 또한 최근들어 전세계적으로 빈발하는 지진에도 그 저항력이 아주 큰 구조물임이 입증이 되어 현재 토목분야에서 각광을 받고 있는 공법이다. 보강토옹벽의 뒤채움재료로서 현재 우리나라에서 쉽게 구할 수 있는 화강풍화토가 많이 사용되고 있다. 그러나, 설계에 필요로 하는 이에 대한 데이터는 그리 많지 않다. 본 연구에서는 어디서나 쉽게 구할 수 있는 화강풍화토를 채취하여 대형 인발시험을 실시하였다. 인발시 흙과 보강재 사이의 상호거동을 파악하기 위하여 인발변위, 인발력, 삽입보강재의 각 지점에서의 절점변위 등을 측정하였다. 그리고 구속응력의 영향을 검토하기 위해서 이들 응력을 0.2, 0.5, 1.0kg/$\textrm{cm}^2$으로 변화시켜 실험을 행하였다. 그리고, 다짐률이 이들 상호거동에 어떤 영향을 미치는지 알아보기 위해서 다짐률을 65%, 80%m 95% 등으로 시료를 제작하여 서로 비교를 행하였다. 실험결과로부터 화강풍화토의 보강재와의 상호거동특성을 파악하여 제시하였다. 특히 다짐률은 상호거동특성에 큰 영향을 미치는 것으로 드러났으며, 화강토의 경우, 꽤 큰 점착특성이 존재하고 있음을 알 수 있었다.

  • PDF

Strength Development Properties of Latex Modified Concrete For New Concrete Bridge Deck Overlay (신설 콘크리트 교면 덧씌우기를 위한 라텍스 개질 콘크리트의 강도발현 특성)

  • Yun, Kyong-Ku;Kim, Ki-Heoun;Lee, Joo-Hyung;Hong, Chang-Woo;Kim, Dong-Ho
    • International Journal of Highway Engineering
    • /
    • v.3 no.3 s.9
    • /
    • pp.135-146
    • /
    • 2001
  • This study focused on the investigation of compressive and flexural strengths development, and bond strength of latex modified concrete in order to validate the feasibility of application into concrete bridge deck overlay. Pull-out bond test was used for evaluating the bond strength of latex modified concrete to substrate. The main experimental variables were latex-cement ratio, surface preparation and moisture levels. The compressive strength of latex modified concrete decreased slightly and the flexural strength increased as the latex content increased from 5% to 20%. This might be due to the flexibility latex filled in voids and interconnections of hydrated cement and aggregates by a film of latex particles, respectively. In general, increasing the amount of latex will produce concrete with increased tensile and flexural strength and lower modulus of elasticity. Significant improvements in bond strength between new and existing concrete were achieved through the modification of the new concrete bridge deck overlay by latex polymers. The effect of surface preparation on bond of latex modified concrete to conventional concrete were significant at the conditions by sand paper and wire brush. A better bond could be achieved by rough surface rather than smooth. The saturated condition of surface is the most appropriate moisture level among the considered followed by dry condition and wet condition.

  • PDF

A Experimental and Analytical Study on One directional Bond Behavior of Grid typed CFRP Reinforcement (격자형 탄소 보강재의 일방향 부착특성에 대한 실험 및 해석적 연구)

  • Chi Hoon Noh;Nak Seop Jang;Hongseob Oh
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.2
    • /
    • pp.77-86
    • /
    • 2024
  • In this study, authors attempted to determine the bond behavior characteristics to utilize Grid typed CFRP reinforcement as an alternative to steel rebar used as concrete reinforcement. Since it is difficult to understand the influence of the transverse grid length of the Grid typed CFRP reinforcement in the existing numerical analysis proposal for bond behavior, a nonlinear 3D model was created and finite element analysis was performed. To perform the analysis, the analysis was conducted by inputting a nonlinear material model and modeling the bond interface characteristics between the Grid typed CFRP reinforcement and concrete and comparing them with the actual direct pull-out test results. The bond behavior characteristics of the Grid typed CFRP reinforcement were found to be very dominated by the factors of the transverse grid, and showed a tendency to continuously increase load.

Evaluation of the Crack Width of the Ultra High Performance Concrete(K-UHPC) Structures (초고성능 콘크리트(K-UHPC) 구조물의 균열폭 평가)

  • Kwahk, Imjong;Lee, Jungwoo;Kim, Jeesang;Joh, Changbin
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.99-108
    • /
    • 2012
  • Ultra High Performance Concrete(UHPC) has compressive strength higher than 180 MPa. The use of steel fibers in the dense UHPC matrix increases tensile strength, ductility and bond strength between UHPC and rebars. However, to apply the advance material behavior of UHPC to the design of a structure, we need design formulas. The crack formula is one of them. This paper investigated experimentally the bond behavior of a rebar and K-UHPC, the UHPC developed by Korea Institute of Construction Technology, and, modified CEB-FIP crack formula based on the test. In addition, this paper tested the crack behavior of K-UHPC reinforced with rebars to verify the modified crack formula. The result showed that the modified formula is reasonable to predict the width of cracks in the reinforced K-UHPC structures.