• Title/Summary/Keyword: direct comparison method

Search Result 585, Processing Time 0.033 seconds

HIPIMS Arc-Free Reactive Deposition of Non-conductive Films Using the Applied Material ENDURA 200 mm Cluster Tool

  • Chistyakov, Roman
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.96-97
    • /
    • 2012
  • In nitride and oxide film deposition, sputtered metals react with nitrogen or oxygen gas in a vacuum chamber to form metal nitride or oxide films on a substrate. The physical properties of sputtered films (metals, oxides, and nitrides) are strongly influenced by magnetron plasma density during the deposition process. Typical target power densities on the magnetron during the deposition process are ~ (5-30) W/cm2, which gives a relatively low plasma density. The main challenge in reactive sputtering is the ability to generate a stable, arc free discharge at high plasma densities. Arcs occur due to formation of an insulating layer on the target surface caused by the re-deposition effect. One current method of generating an arc free discharge is to use the commercially available Pinnacle Plus+ Pulsed DC plasma generator manufactured by Advanced Energy Inc. This plasma generator uses a positive voltage pulse between negative pulses to attract electrons and discharge the target surface, thus preventing arc formation. However, this method can only generate low density plasma and therefore cannot allow full control of film properties. Also, after long runs ~ (1-3) hours, depends on duty cycle the stability of the reactive process is reduced due to increased probability of arc formation. Between 1995 and 1999, a new way of magnetron sputtering called HIPIMS (highly ionized pulse impulse magnetron sputtering) was developed. The main idea of this approach is to apply short ${\sim}(50-100){\mu}s$ high power pulses with a target power densities during the pulse between ~ (1-3) kW/cm2. These high power pulses generate high-density magnetron plasma that can significantly improve and control film properties. From the beginning, HIPIMS method has been applied to reactive sputtering processes for deposition of conductive and nonconductive films. However, commercially available HIPIMS plasma generators have not been able to create a stable, arc-free discharge in most reactive magnetron sputtering processes. HIPIMS plasma generators have been successfully used in reactive sputtering of nitrides for hard coating applications and for Al2O3 films. But until now there has been no HIPIMS data presented on reactive sputtering in cluster tools for semiconductors and MEMs applications. In this presentation, a new method of generating an arc free discharge for reactive HIPIMS using the new Cyprium plasma generator from Zpulser LLC will be introduced. Data (or evidence) will be presented showing that arc formation in reactive HIPIMS can be controlled without applying a positive voltage pulse between high power pulses. Arc-free reactive HIPIMS processes for sputtering AlN, TiO2, TiN and Si3N4 on the Applied Materials ENDURA 200 mm cluster tool will be presented. A direct comparison of the properties of films sputtered with the Advanced Energy Pinnacle Plus + plasma generator and the Zpulser Cyprium plasma generator will be presented.

  • PDF

Comparison of Mycobacterium tuberculosis Specific Antigen Stimulation Time for Performing Interferon Gamma mRNA Assay for Detecting Latent Tuberculosis Infection

  • Kim, Sunghyun;Cho, Jang-Eun;Kim, Hyunjung;Lee, Dongsup;Jeon, Bo-Young;Lee, Hyejon;Cho, Sang-Nae;Kim, Young Keun;Lee, Hyeyoung
    • Biomedical Science Letters
    • /
    • v.19 no.2
    • /
    • pp.90-97
    • /
    • 2013
  • The tuberculin skin test (TST) and interferon gamma (IFN-${\gamma}$) release assay (IGRA) have been widely used for diagnosis of latent tuberculosis infection (LTBI). In order to overcome limitations of current LTBI diagnostic methods, the development of a novel molecular assay which is able to measure the IFN-${\gamma}$ messenger RNA (mRNA) expression level after stimulation with Mycobacterium tuberculosis (MTB) specific antigen was recently developed. The ability of a molecular assay to detect MTB infection was similar to commercial IGRA however, the optimal incubation time for stimulating IFN-${\gamma}$ was not yet established. Therefore, in this study the direct comparisons of MTB Ag stimulation times (4 and 24 hrs) were performed for diagnosis of MTB infection. Data showed that the coincident rate between QFT-GIT IFN-${\gamma}$ ELISA and IFN-${\gamma}$ RT-PCR (4 hrs) was 88.35% and that of QFT-GIT and IFN-${\gamma}$ RT-PCR (24 hrs) was 70.85%. Based on a receiver operating characteristic (ROC) curve, the 4 hrs-MTB specific Ag stimulation time for IFN-${\gamma}$ RT-PCR had the significant P value, 95% CI value, and AUC (P < 0.0001, 95% CI=0.82 to 1.02, and AUC=0.9214) in comparison with 24 hrs-MTB specific Ag stimulation time (P = 0.009, 95% CI=0.06 to 0.94, and AUC=0.7711). These results show that 4-hr was the most optimal MTB Ag stimulation time for performing IFN-${\gamma}$ RT-PCR. Although semi-quantitative RT-PCR had a few analytical limitations, it might be useful as an alternative molecular diagnostic method for detecting MTB infection.

The Relationship with Internet Addiction, VDT Syndrome and Health Behavior of Elementary School Students (초등학생의 인터넷 중독과 VDT 증후군 및 건강행위 간의 관련성)

  • Lee, Gyeong-Ran;Hwang, Mi-Hye
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.9 no.2
    • /
    • pp.65-80
    • /
    • 2008
  • Objectives: To identify the relationship between the internet addition of elementary school students, and their health behavior and VDT syndrome, and thereby to detect the impact of internet addiction on the health behavior of elementary school students, to get the basic information necessary to develop a prevention program for internet addiction and to plan for VDT syndrome prevention program. Methods: We conducted this study during the period from jun 27, 2007 through July 8, 2007. The subjects of this study were 416 children whose grades were in 4th through 6th grades of elementary schools located in the city A in Kyung Pook Providence. Data were obtained from self-rating questionnaires. The questionnaires were composed of Korean Internet Addiction Self-examination on Internet Use Patterns (K-scale), Health Behavior Profile, VDT Syndrome, and general characteristics. We used t-test, AVOVA with Ducan method for Post-hoc comparison in means comparison between groups, $X^2$-test for frequency analysis and Pearson's correlation coefficient. We used SPSS/PC(12.0 ver) program and the LISREL 8.53 Win program for covariance structural analysis. Results: Major results were as follows. 1. The internet addiction propensity distribution based on the distribution of scores were investigated according to the self diagnosis scale on internet addiction. 6.5% of them were high risk user group, 14.4% were potential risk users and 79.1% of them were common user groups. 2. Internet addictions by sex, internet use duration, frequency (days/week), time(hours/day), purpose, position, brightness of internet, attitude of parents and frequency of conversation of family members were statistically significant(p<0.01). 3. There was a statistically significant difference in VDT syndrome according to internet addiction groups(p<0.001) besides ocular symptoms, dry mouth and GI troubles. 4. The health behavior score was the lowest in high risk user group(p<0.001). There were significant differences between internet addiction groups in personal hygiene and habits of daily living(p<.002), the prevention of accidents(p<.002), the practice concerned with the prevention of infectious disease(p=.002), and mental health(p<.001). 5. There was also a significant negative correlation between internal addiction and health profile(r=-0.365, p<0.01) and a significant positive correlation between internal addiction and VDT syndrome(r=0.331, p<0.01). 6. As the result of structural model analysis, internet use time(/day), days of internet use(/1week), conversation frequency among family members, degree of brightness of internet use had significant direct effects on internet addiction. Conclusions: The results will help the development of an effective intervention program for the prevention and treatment of internal addiction by clarifying the effect of the internal addiction upon elementary school students' VDT syndrome and health behavior.

  • PDF

Generating Rank-Comparison Decision Rules with Variable Number of Genes for Cancer Classification (순위 비교를 기반으로 하는 다양한 유전자 개수로 이루어진 암 분류 결정 규칙의 생성)

  • Yoon, Young-Mi;Bien, Sang-Jay;Park, Sang-Hyun
    • The KIPS Transactions:PartD
    • /
    • v.15D no.6
    • /
    • pp.767-776
    • /
    • 2008
  • Microarray technology is extensively being used in experimental molecular biology field. Microarray experiments generate quantitative expression measurements for thousands of genes simultaneously, which is useful for the phenotype classification of many diseases. One of the two major problems in microarray data classification is that the number of genes exceeds the number of tissue samples. The other problem is that current methods generate classifiers that are accurate but difficult to interpret. Our paper addresses these two problems. We performed a direct integration of individual microarrays with same biological objectives by transforming an expression value into a rank value within a sample and generated rank-comparison decision rules with variable number of genes for cancer classification. Our classifier is an ensemble method which has k top scoring decision rules. Each rule contains a number of genes, a relationship among involved genes, and a class label. Current classifiers which are also ensemble methods consist of k top scoring decision rules. However these classifiers fix the number of genes in each rule as a pair or a triple. In this paper we generalized the number of genes involved in each rule. The number of genes in each rule is in the range of 2 to N respectively. Generalizing the number of genes increases the robustness and the reliability of the classifier for the class prediction of an independent sample. Also our classifier is readily interpretable, accurate with small number of genes, and shed a possibility of the use in a clinical setting.

Direct Imaging of Polarization-induced Charge Distribution and Domain Switching using TEM

  • O, Sang-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.99-99
    • /
    • 2013
  • In this talk, I will present two research works in progress, which are: i) mapping of piezoelectric polarization and associated charge density distribution in the heteroepitaxial InGaN/GaN multi-quantum well (MQW) structure of a light emitting diode (LED) by using inline electron holography and ii) in-situ observation of the polarization switching process of an ferroelectric Pb(Zr1-x,Tix)O3 (PZT) thin film capacitor under an applied electric field in transmission electron microscope (TEM). In the first part, I will show that strain as well as total charge density distributions can be mapped quantitatively across all the functional layers constituting a LED, including n-type GaN, InGaN/GaN MQWs, and p-type GaN with sub-nm spatial resolution (~0.8 nm) by using inline electron holography. The experimentally obtained strain maps were verified by comparison with finite element method simulations and confirmed that not only InGaN QWs (2.5 nm in thickness) but also GaN QBs (10 nm in thickness) in the MQW structure are strained complementary to accommodate the lattice misfit strain. Because of this complementary strain of GaN QBs, the strain gradient and also (piezoelectric) polarization gradient across the MQW changes more steeply than expected, resulting in more polarization charge density at the MQW interfaces than the typically expected value from the spontaneous polarization mismatch alone. By quantitative and comparative analysis of the total charge density map with the polarization charge map, we can clarify what extent of the polarization charges are compensated by the electrons supplied from the n-doped GaN QBs. Comparison with the simulated energy band diagrams with various screening parameters show that only 60% of the net polarization charges are compensated by the electrons from the GaN QBs, which results in the internal field of ~2.0 MV cm-1 across each pair of GaN/InGaN of the MQW structure. In the second part of my talk, I will present in-situ observations of the polarization switching process of a planar Ni/PZT/SrRuO3 capacitor using TEM. We observed the preferential, but asymmetric, nucleation and forward growth of switched c-domains at the PZT/electrode interfaces arising from the built-in electric field beneath each interface. The subsequent sideways growth was inhibited by the depolarization field due to the imperfect charge compensation at the counter electrode and preexisting a-domain walls, leading to asymmetric switching. It was found that the preexisting a-domains split into fine a- and c-domains constituting a $90^{\circ}$ stripe domain pattern during the $180^{\circ}$ polarization switching process, revealing that these domains also actively participated in the out-of-plane polarization switching. The real-time observations uncovered the origin of the switching asymmetry and further clarified the importance of charged domain walls and the interfaces with electrodes in the ferroelectric switching processes.

  • PDF

A Study on the long-term Hemodialysis patient중s hypotension and preventation from Blood loss in coil during the Hemodialysis (장기혈액투석환자의 투석중 혈압하강과 Coil내 혈액손실 방지를 위한 기초조사)

  • 박순옥
    • Journal of Korean Academy of Nursing
    • /
    • v.11 no.2
    • /
    • pp.83-104
    • /
    • 1981
  • Hemodialysis is essential treatment for the chronic renal failure patient's long-term cure and for the patient management before and after kidney transplantation. It sustains the endstage renal failure patient's life which didn't get well despite strict regimen and furthermore it becomes an essential treatment to maintain civil life. Bursing implementation in hemodialysis may affect the significant effect on patient's life. The purpose of this study was to obtain the basic data to solve the hypotension problem encountable to patient and the blood loss problem affecting hemodialysis patient'a anemic states by incomplete rinsing of blood in coil through all process of hemodialysis. The subjects for this study were 44 patients treated hemodialysis 691 times in the hemodialysis unit, The .data was collected at Gang Nam 51. Mary's Hospital from January 1, 1981 to April 30, 1981 by using the direct observation method and the clinical laboratory test for laboratory data and body weight and was analysed by the use of analysis of Chi-square, t-test and anlysis of varience. The results obtained an follows; A. On clinical laboratory data and other data by dialysis Procedure. The average initial body weight was 2.37 ± 0.97kg, and average body weight after every dialysis was 2.33 ± 0.9kg. The subject's average hemoglobin was 7.05±1.93gm/dl and average hematocrit was 20.84± 3.82%. Average initial blood pressure was 174.03±23,75mmHg and after dialysis was 158.45±25.08mmHg. The subject's average blood ion due to blood sample for laboratory data was 32.78±13.49cc/ month. The subject's average blood replacement for blood complementation was 1.31 ±0.88 pint/ month for every patient. B. On the hypotensive state and the coping approaches occurrence rate of hypotension was 28.08%. It was 194 cases among 691 times. 1. In degrees of initial blood pressure, the most 36.6% was in the group of 150-179mmHg, and in degrees of hypotension during dialysis, the most 28.9% in the group of 40-50mmHg, especially if the initial blood pressure was under 180mmHg, 59.8% clinical symptoms appeared in the group of“above 20mmHg of hypotension”. If initial blood pressure was above 180mmHg, 34.2% of clinical symptoms were appeared in the group of“above 40mmHg of hypotension”. These tendencies showed the higher initial blood pressure and the stronger degree of hypotension, these results showed statistically singificant differences. (P=0.0000) 2. Of the occuring times of hypotension,“after 3 hrs”were 29.4%, the longer the dialyzing procedure, the stronger degree of hypotension ann these showed statistically significant differences. (P=0.0142). 3. Of the dispersion of symptoms observed, sweat and flush were 43.3%, and Yawning, and dizziness 37.6%. These were the important symptoms implying hypotension during hemodialysis accordingly. Strages of procedures in coping with hypotension were as follows ; 45.9% were recovered by reducing the blood flow rate from 200cc/min to 1 00cc/min, and by reducing venous pressure to 0-30mmHg. 33.51% were recovered by controling (adjusting) blood flow rate and by infusion of 300cc of 0,9% Normal saline. 4.1% were recovered by infusion of over 300cc of 0.9% normal saline. 3.6% by substituting Nor-epinephiine, 5.7% by substituting blood transfusion, and 7,2% by substituting Albumin were recovered. And the stronger the degree of symptoms observed in hypotention, the more the treatments required for recovery and these showed statistically significant differences (P=0.0000). C. On the effects of the changes of blood pressure and osmolality by albumin and hemofiltration. 1. Changes of blood pressure in the group which didn't required treatment in hypotension and the group required treatment, were averaged 21.5mmHg and 44.82mmHg. So the difference in the latter was bigger than the former and these showed statistically significant difference (P=0.002). On the changes of osmolality, average mean were 12.65mOsm, and 17.57mOsm. So the difference was bigger in the latter than in the former but these not showed statistically significance (P=0.323). 2. Changes of blood pressure in the group infused albumin and in the group didn't required treatment in hypotension, were averaged 30mmHg and 21.5mmHg. So there was no significant differences and it showed no statistical significance (P=0.503). Changes of osmolality were averaged 5.63mOsm and 12.65mOsm. So the difference was smaller in the former but these was no stitistical significance (P=0.287). Changes of blood pressure in the group infused Albumin and in the group required treatment in hypotension were averaged 30mmHg and 44.82mmHg. So the difference was smaller in the former but there is no significant difference (P=0.061). Changes of osmolality were averaged 8.63mOsm, and 17.59mOsm. So the difference were smaller in the former but these not showed statistically significance (P=0.093). 3. Changes of blood pressure in the group iutplemented hemofiltration and in the Uoup didn't required treatment in hypotension were averaged 22mmHg and 21.5mmHg. So there was no significant differences and also these showed no statistical significance (P=0.320). Changes of osmolality were averaged 0.4mOsm and 12.65mOsm. So the difference was smaller in the former but these not showed statistical significance(P=0.199). Changes of blood pressure in the group implemented hemofiltration and in the group required treatment in hypotension were averaged 22mmHg and 44.82mmHg. So the difference was smatter in the former and these showed statistically significant differences (P=0.035). Changes of osmolality were averaged 0.4mOsm and 17.59mOsm. So the difference was smaller in the former but these not showed statistical significance (P=0.086). D. On the changes of body weight, and blood pressure, between the group of hemofiltration and hemodialysis. 1, Changes of body weight in the group implemented hemofiltration and hemodialysis were averaged 3.340 and 3.320. So there was no significant differences and these showed no statistically significant difference, (P=0.185) but standard deviation of body weight averaged in comparison with standard difference of body weight was statistically significant difference (P=0.0000). Change of blood Pressure in the group implemented hemofiltration and hemodialysis were averaged 17.81mmHg and 19.47mmHg. So there was no significant differences and these showed no statistically significant difference (P=0.119), But in comparison with standard deviation about difference of blood pressure was statistically significant difference. (P=0.0000). E. On the blood infusion method in coil after hemodialysis and residual blood losing method in coil. 1, On comparing and analysing Hct of residual blood in coil by factors influencing blood infusion method. Infusion method of saline 200cc reduced residual blood in coil after the quantitative comparison of Saline Occ, 50cc, 100cc, 200cc and the differences showed statistical significance (p < 0.001). Shaking Coil method reduced residual blood in Coil in comparison of Shaking Coil method and Non-Shaking Coil method this showed statistically significant difference (P < 0.05). Adjusting pressure in Coil at OmmHg method reduced residual blood in Coil in comparison of adjusting pressure in Coil at OmmHg and 200mmHg, and this showed statistically significant difference (P < 0.001). 2. Comparing blood infusion method divided into 10 methods in Coil with every factor respectively, there was seldom difference in group of choosing Saline 100cc infusion between Coil at OmmHg. The measured quantity of blood loss was averaged 13.49cc. Shaking Coil method in case of choosing saline 50cc infusion while adjusting pressure in coil at OmmHg was the most effective to reduce residual blood. The measured quantity of blood loss was averaged 15.18cc.

  • PDF

A Rapid Analysis of 226Ra in Raw Materials and By-Products Using Gamma-ray Spectrometry (감마분광분석을 이용한 원료물질 및 공정부산물 중 226Ra 신속분석방법)

  • Lim, Chung-Sup;Chung, Kun-Ho;Kim, Chang-Jong;Ji, Young-Yong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.1
    • /
    • pp.35-44
    • /
    • 2017
  • A gamma-ray peak of $^{226}Ra$ (186.2 keV) overlaps with one of $^{235}U$ (185.7 keV) in a gamma-ray spectrometry system. Though reference peaks of $^{235}U$ can be used to correct the peak interference of $^{235}U$ in the analysis of $^{226}Ra$, this requires a complicated calculation process and a high limit of quantitation. On the other hand, evaluating $^{226}Ra$ using the correction constant in the overlapped peak can make a rapid measurement of $^{226}Ra$ without the complicated calculation process as well as overcome the disadvantage in the indirect measurement of $^{214}Bi$, which means the confinement of $^{222}Rn$ gas in a sample container and a time period to recover the secular equilibrium. About 93 samples with 6 species for raw-materials and by-products were prepared to evaluate the activity of $^{226}Ra$ using the correction constant. The results were compared with the activity of $^{214}Bi$, which means the indirect measurement of $^{226}Ra$, to validate the method of the direct measurement of $^{226}Ra$ using the correction constant. The difference between the direct and indirect measurement of $^{226}Ra$ was generally below about ${\pm}20%$. However, in the case of the phospho gypsum, a large error of about 50% was found in the comparison results, which indicates the disequilibrium between $^{238}U$ and $^{226}Ra$ in the materials. Application results of the contribution ratio of $^{226}Ra$ were below about ${\pm}10%$. The direct measurement of $^{226}Ra$ using the correction constant can be an effective method for its rapid measurement of raw materials and by-products because the activity of $^{226}Ra$ can be produced with a simple calculation without the consideration of the integrity of a sample container and the time period to recover the secular equilibrium.

Screening method for amines by derivatization reaction on TLC (TLC 상 유도체화 반응을 이용한 아민 계 화합물의 Screening 방법)

  • Choi, Sung-Woon;Lee, Hye-In;Sung, Nack-Do
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.228-234
    • /
    • 2013
  • Methamphetamine is an amine-containing illegal drug and is distributed unlawfully in South Korea. Finding a rapid, convenient and semi-quantitative determination method for methamphetamine is a very important issue in the area of forensic drug testing. As an effort to develop new screening method, the reactions between three organic compounds which are structurally similar to methamphetamine and N-(9-fluorenylmethoxycarbonyloxy) succinimide (FMOC-NHS) were performed on silica gel ($SiO_2$) TLC plates. Three reference compounds were synthesized and used for the identification, comparison and study of the limit of detection (LOD) of the products obtained from a direct reaction on a TLC plate. As a result, FMOC-NHS as a derivatization reagent generated compounds containing highly UV-active functional groups on the TLC plate after reacting with primary- and secondary amines. In the experiment 2D the LOD of amines was in the range of 0.045 and 0.01 mg/mL ($2{\mu}L/spot$), and in 1D the LOD was in the range of 0.002 and 0.007 mg/mL ($2{\mu}L/spot$). The LODs of the compounds tested were dependent on the concentration of the derivatizing reagent.

Seismic First Arrival Time Computation in 3D Inhomogeneous Tilted Transversely Isotropic Media (3차원 불균질 횡등방성 매질에 대한 탄성파 초동 주시 모델링)

  • Jeong, Chang-Ho;Suh, Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.3
    • /
    • pp.241-249
    • /
    • 2006
  • Due to the long tectonic history and the very complex geologic formations in Korea, the anisotropic characteristics of subsurface material may often change very greatly and locally. The algorithms commonly used, however, may not give sufficiently precise computational results of traveltime data particularly for the complex and strong anisotropic model, since they are based on the two-dimensional (2D) earth and/or weak anisotropy assumptions. This study is intended to develope a three-dimensional (3D) modeling algorithm to precisely calculate the first arrival time in the complex anisotropic media. Considering the complex geology of Korea, we assume 3D TTI (tilted transversely isotropy) medium having the arbitrary symmetry axis. The algorithm includes the 2D non-linear interpolation scheme to calculate the traveltimes inside the grid and the 3D traveltime mapping to fill the 3D model with first arrival times. The weak anisotropy assumption, moreover, can be overcome through devising a numerical approach of the steepest descent method in the calculation of minimum traveltime, instead of using approximate solution. The performance of the algorithm developed in this study is demonstrated by the comparison of the analytic and numerical solutions for the homogeneous anisotropic earth as well as through the numerical experiment for the two layer model whose anisotropic properties are greatly different each other. We expect that the developed modeling algorithm can be used in the development of processing and inversion schemes of seismic data acquired in strongly anisotropic environment, such as migration, velocity analysis, cross-well tomography and so on.

Comparison of Lambertian Model on Multi-Channel Algorithm for Estimating Land Surface Temperature Based on Remote Sensing Imagery

  • A Sediyo Adi Nugraha;Muhammad Kamal;Sigit Heru Murti;Wirastuti Widyatmanti
    • Korean Journal of Remote Sensing
    • /
    • v.40 no.4
    • /
    • pp.397-418
    • /
    • 2024
  • The Land Surface Temperature (LST) is a crucial parameter in identifying drought. It is essential to identify how LST can increase its accuracy, particularly in mountainous and hill areas. Increasing the LST accuracy can be achieved by applying early data processing in the correction phase, specifically in the context of topographic correction on the Lambertian model. Empirical evidence has demonstrated that this particular stage effectively enhances the process of identifying objects, especially within areas that lack direct illumination. Therefore, this research aims to examine the application of the Lambertian model in estimating LST using the Multi-Channel Method (MCM) across various physiographic regions. Lambertian model is a method that utilizes Lambertian reflectance and specifically addresses the radiance value obtained from Sun-Canopy-Sensor(SCS) and Cosine Correction measurements. Applying topographical adjustment to the LST outcome results in a notable augmentation in the dispersion of LST values. Nevertheless, the area physiography is also significant as the plains terrain tends to have an extreme LST value of ≥ 350 K. In mountainous and hilly terrains, the LST value often falls within the range of 310-325 K. The absence of topographic correction in LST results in varying values: 22 K for the plains area, 12-21 K for hilly and mountainous terrain, and 7-9 K for both plains and mountainous terrains. Furthermore, validation results indicate that employing the Lambertian model with SCS and Cosine Correction methods yields superior outcomes compared to processing without the Lambertian model, particularly in hilly and mountainous terrain. Conversely, in plain areas, the Lambertian model's application proves suboptimal. Additionally, the relationship between physiography and LST derived using the Lambertian model shows a high average R2 value of 0.99. The lowest errors(K) and root mean square error values, approximately ±2 K and 0.54, respectively, were achieved using the Lambertian model with the SCS method. Based on the findings, this research concluded that the Lambertian model could increase LST values. These corrected values are often higher than the LST values obtained without the Lambertian model.