• Title/Summary/Keyword: dimensionless superficial velocity

Search Result 5, Processing Time 0.021 seconds

Heat Transfer in Bubble Columns with High Viscous and Low Surface Tension Media (고점성 낮은표면장력 매체 기포탑에서 열전달)

  • Kim, Wan Tae;Lim, Dae Ho;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.52 no.4
    • /
    • pp.516-521
    • /
    • 2014
  • Axial and overall heat transfer coefficients were investigated in a bubble column with relatively high viscous and low surface tension media. Effects of superficial gas velocity (0.02~0.1 m/s), liquid viscosity ($0.1{\sim}0.3Pa{\cdot}s$) and surface tension ($66.1{\sim}72.9{\times}10^{-3}N/m$) on the local and overall heat transfer coefficients were examined. The heat transfer field was composed of the immersed heater and the bubble column; a vertical heater was installed at the center of the column coaxially. The heat transfer coefficient was determined by measuring the temperature differences continuously between the heater surface and the column which was bubbling in a given operating condition, with the knowledge of heat supply to the heater. The local heat transfer coefficient increased with increasing superficial gas velocity but decreased with increasing axial distance from the gas distributor and liquid surface tension. The overall heat transfer coefficient increased with increasing superficial gas velocity but decreased with increasing liquid viscosity or surface tension. The overall heat transfer coefficient was well correlated in terms of operating variables such as superficial gas velocity, liquid surface tension and liquid viscosity with a correlation coefficient of 0.91, and in terms of dimensionless groups such as Nusselt, Reynolds, Prandtl and Weber numbers with a correlation of 0.92; $$h=2502U^{0.236}_{G}{\mu}^{-0.250}_{L}{\sigma}^{-0.028}_L$$ $$Nu=325Re^{0.180}Pr^{-0.067}We^{0.028}$$.

Separation Performance of Zigzag Air Classifier

  • Hirajima, Tsuyoshi;Nishida, Takuji;Toshima, Ryutaro;Kataoka, Kenji;Tsunekawa, Masami;Asakura, Kuniomi
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.759-764
    • /
    • 2001
  • The separation performance of zigzag air classifier with angle of 90 degrees was studied using narrow size fractions of thin square samples and granular samples. The simulation results of air velocity inside the classifier indicated that the zigzag geometry induces a new pattern consisting of an upward flow and a circulation flow, Experimental results showed that overflow product recovery was described as an integral calculus of normal distribution as a function of dimensionless air velocity ( $V_{A}$ $V_{A50}$), where $V_{A}$ is superficial air velocity and $V_{A50}$ is the $V_{A}$ at the fifty percent recovery. The $V_{A}$ values were predicted using the equations derived from dynamics for a particle dropping in air. A monitoring system that utilizes changes in acoustic signals emitted during the process of air classification was developed to separate PET with desired recovery or grade. The technical feasibility of the on-line monitoring of the PET recovery and grade was demonstrated by measuring relative energy of the signals.signals.als.

  • PDF

Effect of Geometric and Dynamic Parameters on Mixing Characteristic in an Internal-Loop Apparatus (내부 순환 장치의 크기 및 유속 변화에 따른 혼합특성)

  • 최윤찬;김동석
    • KSBB Journal
    • /
    • v.11 no.4
    • /
    • pp.405-410
    • /
    • 1996
  • This paper discussed the dispersion effect according to the geometrical variation of an internal-loop spparatus by the method of pulse injection of a tracer. The Bodenstein number, which is the dimensionless group characterizing the effect of dispersion, was decreased with increasing the superficial gas velocity in the 50L and the 500L apparatus. But, in the 5L apparatus, the Bodenstein number was increased with increasing the superficial gas velocity in the range of 0 to 2cm/sec but above that range the rate of increase was dropped down to give a constant value because of the phenomenon of gas disengagement. The principle of similarity based on dimensional analysis was applied to design a pilot scale internal-loop apparatus. The effect of dispersion was examined in three different internal-loop apparatus to give the following correlation with major geometric and fluid dynamic properties as variables. B0=4.4014ReG0.117 ReL-0.0065(Hr/Dr)0.76(Dd/Dr)-0.76

  • PDF

Air-Water Countercurrent Flow Limitation in a Horizontal Pipe Connected to an Inclined Riser

  • Kang, Seong-Kwon;Chu, In-Cheol;No, Hee-Cheon;Chun, Moon-Hyun;Sung, Chang-Kyung
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.548-560
    • /
    • 1999
  • An experimental investigation has been peformed to examine the effects of various geometrical parameters and an initial operating condition on the air-water countercurrent How limitation (CCFL) in a simulated PWR hot leg. A total of 118 experimental data for the onset of CCFL and zero liquid penetration were obtained for various combinations of test parameters. It was observe that the CCFL can be classified into three different categories: (the onset of CCFL, (the partial liquid delivery, and (r) the zero liquid penetration. The observed mechanisms of the onset of CCFL were different depending on the inlet water flow rate. The parametric effects of pipe diameter, horizontal pipe length, horizontal pipe length-to-diameter (L/D) ratio, and initial water level in the horizontal pipe of the test section on the onset of air-water CCFL were also examined. An empirical correlation for the onset of CCFL in a horizontal pipe connected to an inclined riser was developed in terms of Wallis flooding parameters for the low inlet water flow rate region. Comparisons of the present empirical correlation with the air-water CCFL data of large pipe diameters show that the present correlation agrees more closely with the experimental data than the existing CCFL correlations.

  • PDF

Development of a 9as-liquid two-phase flowmeter using double orifice plates (2중판 오리피스를 이용한 기액 2상유량계의 개발)

  • 이상천;이상무;남상철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.619-629
    • /
    • 1998
  • An experimental work was conducted to investigate a feasibility of simultaneous measurement of gas-liquid two-phase flowrates with double orifice plates using air and water. The tests were carried out under the atmospheric pressure and at the ambient temperature using two different tube sizes. Qualities of an air-water flow in the present study have values less than 0.1 and thus the mixed flow showed bubbly, plug, slug flow regimes. The probability density function (PDF) and the power spectral density function (PSDF) of the instantaneous pressure drop traces for the flow regimes were obtained. It is found that some distinctive features exist in the distribution of these functions, depending upon the two-phase flow pattern. The time-averaged value of the instantaneous pressure drop increases with increasing gas and liquid flowrates, showing a single-valued function for the total mass flowrate and the quality. It is also found that the two-phase discharge coefficient exhibits a consistent trend for variation of dimensionless parameters such as the superficial velocity ratio and the gas Reynolds number. The results indicate that simultaneous measurement of two-phase flowrate may be possible based upon a statistical analysis of the instantaneous pressure drop curves monitored using double orifice plates.

  • PDF