• 제목/요약/키워드: dimensional limit

검색결과 488건 처리시간 0.026초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

생태학적 디자인을 기반으로 한 근 미래형 친환경주택연구 (A Study on the Eco-friendly Housing in the Near future based on the Ecological Design)

  • 추진;유보현
    • 디자인학연구
    • /
    • 제18권4호
    • /
    • pp.105-118
    • /
    • 2005
  • 20세기의 산업화에 따른 문명의 발전과 기술의 고도화를 통해 인간들은 다양한 편리성을 누리게 되었다. 그러나 21세기는 개발중심적인 편향적 발전에 대한 생태학적 한계를 극복하고 우리의 후손에게 좀 더 깨끗한 환경을 물려주는 이른바 '지속가능 한 환경'을 만드는 시대라는 점에 공감하고 있다. 환경공생이 가지는 범위는 미시적 차원의 환경에서 거시적 차원의 환경에 이르기까지 다양한 수준의 환경적 어울림을 뜻하는 것이다. 이에 따른 친환경주택의 세 가지 목표는 지구환경 보전, 주변 환경과의 친화성, 주거환경의 건강과 저 적성이다. 환경공생의 관점에서 본다면, 주택은 지구환경보전을 위해 에너지와 자원을 절약해야 하고 태양열이나 풍력 등을 이용한 자연 에너지의 집적과 우수의 재사용, 폐기물의 감소와 재활용이 생활 속에서 실천되어야 한다. 주변 환경과의 친화성이 이루어지도록 기후풍토, 지리 등 생태학적으로 환경을 이해하여 빛과 바람 그리고 동식물 등의 환경요소와 잘 화합하는 개발을 하도록 유도하여야 하고 그 구성원 또한 건강하여야 한다. 그리고 주거환경의 건강과 쾌적성을 위하여 청정한 공기와 온도, 습도, 통풍 등이 잘 유지되도록 친환경 소재를 통한 지구의 유한한 에너지 보전과 재활용에 더욱 노력을 아끼지 말아야 할 것이다. 친환경주택은 생태주의라는 새로운 패러다임으로의 전환 없이는 도전하기도 실현하기도 어려운 새로운 사회적 사명이 되었다. 특히 국내의 친환경적용 주택의 사례나 연구가 아직 선진국에 비해 많지 않음께 아쉬움을 느끼며 본 연구가 환경적 삶과 질을 확보하기 위한 의식의 고취와 관심의 증대를 가져오길 바라며, 이러한 연구는 앞으로 좀 더 구체화되고 체계화되어 우리가 궁극적으로 추구해야 할 건강하고 행복한 삶을 위한 새로운 문명적 패러다임을 위한 하나의 기틀이 되어질 수 있도록 해야 할 것이다.리팀)를 중심으로 하는 QFD(quality function development)의 접근방법, (2) 마케팅 담당자를 중심으로 하는 컨조인트 분석(conjoint analysis), (3) 상기의 2가지 접근방법의 상호보완적 및 동시적 결합 및 피드백의 주장(Pullman, Moore and Wardell, 2002)을 들 수 있다. 그러나 본 연구의 실증적 분석결과에는 품질경쟁력이 제품 디자인과 고객만족사이에 교량적 역할을 담당한다. 이 분석결과는 제품 디자인에 대한 품질경쟁력의 2가지 접근방법(QFD의 접근방법과 컨조인트 분석)의 조화를 이룰 수 있는 이론적 기초가 될 수 있다. 즉, 제품디자인의 결정요인 분석결과는 QFD의 접근방법에, 제품 디자인 파급효과 분석결과는 컨조인트 분석에 각각 보완적 기여를 할 수 있다. 이와 동시에, 실증적 분석결과는 Ettlie(1997)의 디자인 통합(DI) 이론에 대한 실증적 기반을 제공할 수 있다. 마지막으로, 성공적인 디자인 경영(DM)을 위해서는 최고 경영자의 지원뿐만 아니라 부처 간 의사소통의 장애요인을 제거하고 CFT(cross-functional team)를 운영함으로써 동시적 엔지니어링(CE) 및 제품 및 공정 디자인의 개발이 제품 개발의 속도를 가속화하고 디자인 품질을 높이며 시장 성공을 보증할 수 있도록 해야 한다.임과 채팅은 긍정적인 상호관련을 가진 것으로 나타난 반면 전자메일 서비스 이용은 성적 만족과 부정적인 상호관련을 가진 것으로 분석되었다. 이는 대학생들이 지루하게 느끼거나 외로움을 느낄 때 전자메일을 주로 이용하지만 성적 만족을 위해 전자메일을 이용하지 않고 있다는 사실을 보여주는 것이다. (3) 인터넷 이용 이후 다른 미디어와 면대면 커뮤니케이션과의 관계 인터넷을 이용한 후 응답자들의 전통적인 미디어(텔레비전, 라디오, 신문, 잡지,

  • PDF

서울 성북동 역사문화자원 주변경관의 시각적 특성연구 (Research on the Visual Historical & Cultural Resources of Seongbuk-dong)

  • 이원호;김재웅
    • 한국전통조경학회지
    • /
    • 제31권2호
    • /
    • pp.118-127
    • /
    • 2013
  • 본 논문은 성북동의 역사문화자원 주변경관을 대상으로 경관 형용사 분석에 의한 시각적 특성을 분석하고, 시각적 특성과 선호도와의 관계를 파악하고자 하였다. 연구는 성북동에 위치하고 있는 역사문화자원 주변 경관사진 30장을 선정하여 설문조사를 실시하였으며, 경관 선호요인을 파악하기 위하여 16개 형용사를 척도화하여 요인분석을 실시하였다. 마지막으로 이미지 요인이 시각적 선호도에 미치는 영향을 파악하기 위하여 분산분석과 회귀분석을 실시하였다. 그 결과는 다음과 같이 요약될 수 있다. 첫째, 성북동 내 역사문화자원이 분포하고 있는 주변에 나타나는 경관에 대한 30장의 사진을 대상으로 16개의 형용사 어휘에 대한 선호도 평균분석을 실시한 결과, 전체적인 선호도 평균치는 3.72로 분석되었는데, 이들 중 4.5점 이상의 사진은 VP8번, VP9번, VP10번, VP12번, VP15번의 순으로 높게 나타났으며, 전체적으로 높은 선호를 보인 곳은 마포 최사영 고택과 성락원 주변경관으로, 이는 역사문화자원 주변에 대한 서울시 경관계획에 의해 고도를 제한함으로써 역사문화환경보존지역에서 문화재와 조화를 이루고 있으며, 북한산에서 북악산으로 이어지는 조망경관이 양호하게 확보되고 있는 것이 중요한 이유로 판단된다. 둘째, 역사문화자원 주변경관에 대한 시각적 특성을 요인 분석한 결과, 요인 1(심미적 요인), 요인 2(문화적 요인), 요인 3(물리적 요인) 등 3가지 요인으로 요약되어 구분할 수 있었으며, 시각적 선호도와 이미지 요인에 대한 회귀분석 및 분산분석 결과는 심리적 요인이 성북동의 역사문화자원 주변경관에 대한 시각적 선호 이미지를 설명하는 가장 중요한 요인으로 나타났다. 이는 역사문화자원에 대한 조망이 불가능한 상태에서 역사문화자원 주변에 위치한 주거지역에 대한 심미적 요인이 높은 것으로 분석된 것이다. 셋째, 역사문화자원 중 정비되지 않은 주거지역 주변경관에서는 부정적인 측면의 인자가 부각되고 있으며, 역사문화자원과 조화될수록 물리적, 문화적, 심미적 특성의 3가지 영역에서 긍정적인 측면의 인자가 높게 부각되고 있는 것을 알 수 있었다. 향후, 본 연구에서 표출된 인자에 대한 요인을 분석함으로써 역사문화자원 주변의 경관관리에 있어 중요하게 고려되어야 할 요인을 도출하기 위한 다각적 분석이 필요하다.

몬테칼로 전산모사를 이용한 셋업오차가 임상표적체적에 전달되는 선량과 셋업마진에 대하여 미치는 영향 평가 (Evaluation of Setup Uncertainty on the CTV Dose and Setup Margin Using Monte Carlo Simulation)

  • 조일성;곽정원;조병철;김종훈;안승도;박성호
    • 한국의학물리학회지:의학물리
    • /
    • 제23권2호
    • /
    • pp.81-90
    • /
    • 2012
  • 방사선 치료에서 부정확한 환자 셋업이 표적에 전달되는 선량에 미치는 영향과 치료 마진과의 연관성을 몬테칼로 기법을 사용한 전산모사를 통하여 분석하였다. 실제 방사선 치료를 받은 직장암 환자에 대한 임상표적체적(CTV: Clinical Target Volume) 및 주요장기의 구조와 치료계획 시스템(Eclipse 8.9, USA)을 이용하여 수립된 세기조절 방사선치료계획에서의 선량분포에 대한 데이터를 전산모사에서 사용하였다. 전산모사 프로그램은 리눅스환경에서 오픈소스인 ROOT 라이브러리와 GCC를 기반으로 본 연구를 위하여 개발되었다. 환자셋업오차의 확률분포를 정규분포로 가정한 것에 따라 무작위로 생성된 크기만큼 셋업이 부정확한 경우를 모사하여 임상표적체적에서의 선량분포의 변화와 오차크기에 따른 마진크기를 3차원입체조형 방사선치료에 사용되는 마진공식과 비교분석 하였다. 셋업오차 생성에 사용된 정규분포의 표준편차 크기는 1 mm부터 10 mm까지 1 mm간격으로 두었으며 계통오차와 통계오차별로 2,000번 전산모사했다. 계통오차의 경우 전산모사에 사용된 표준편차가 커질수록 임상표적체적에 조사되는 최소선량 $D_{min}^{stat{\cdot}}$은 100.4%에서 72.50%로 감소하였고 평균선량 $\bar{D}_{syst{\cdot}}$도 100.45%에서 97.88%로 감소한 반면에 표준편차${\Delta}D_{sys}$는 0.02%에서 3.33%로 증가하였다. 통계오차의 경우 최소선량 $D_{min}^{rand{\cdot}}$은 100.45%에서 94.80%감소하였고 평균선량 $\bar{D}_{syst{\cdot}}$도 100.46%에서 97.87%로 감소하였으며 표준편차 ${\Delta}D_{rand}$는 0.01%에서 0.63%로 증가하였다. 그리고 마진공식으로부터 전산모사에 사용된 셋업오차에 해당되는 마진크기를 구하고 모집단비율(population ratio)을 정의하여 기존 마진공식의 목적이 세기조절방사선치료에 만족함을 확인했다. 개발된 전산모사 프로그램은 해당 환자의 치료계획 정보를 직접 사용하므로 직장암만 아니라 두경부암, 전립선암 등 여러 환부에 적용 가능하며 셋업오차 및 선량변화에 연관된 연구에도 사용할 수 있을 것으로 사료된다.

복합 문서의 의미적 분해를 통한 다중 벡터 문서 임베딩 방법론 (Multi-Vector Document Embedding Using Semantic Decomposition of Complex Documents)

  • 박종인;김남규
    • 지능정보연구
    • /
    • 제25권3호
    • /
    • pp.19-41
    • /
    • 2019
  • 텍스트 데이터에 대한 다양한 분석을 위해 최근 비정형 텍스트 데이터를 구조화하는 방안에 대한 연구가 활발하게 이루어지고 있다. doc2Vec으로 대표되는 기존 문서 임베딩 방법은 문서가 포함한 모든 단어를 사용하여 벡터를 만들기 때문에, 문서 벡터가 핵심 단어뿐 아니라 주변 단어의 영향도 함께 받는다는 한계가 있다. 또한 기존 문서 임베딩 방법은 하나의 문서가 하나의 벡터로 표현되기 때문에, 다양한 주제를 복합적으로 갖는 복합 문서를 정확하게 사상하기 어렵다는 한계를 갖는다. 본 논문에서는 기존의 문서 임베딩이 갖는 이러한 두 가지 한계를 극복하기 위해 다중 벡터 문서 임베딩 방법론을 새롭게 제안한다. 구체적으로 제안 방법론은 전체 단어가 아닌 핵심 단어만 이용하여 문서를 벡터화하고, 문서가 포함하는 다양한 주제를 분해하여 하나의 문서를 여러 벡터의 집합으로 표현한다. KISS에서 수집한 총 3,147개의 논문에 대한 실험을 통해 복합 문서를 단일 벡터로 표현하는 경우의 벡터 왜곡 현상을 확인하였으며, 복합 문서를 의미적으로 분해하여 다중 벡터로 나타내는 제안 방법론에 의해 이러한 왜곡 현상을 보정하고 각 문서를 더욱 정확하게 임베딩할 수 있음을 확인하였다.

교동도 사운드스케이프의 특성과 재현 (On the Characteristic and Representation of Kyodong Island Soundscape)

  • 김지나;조경진;권병준
    • 한국조경학회지
    • /
    • 제47권1호
    • /
    • pp.57-75
    • /
    • 2019
  • 본 연구는 사운드스케이프를 통해 시각적 풍경 이면에 축적되어 있는 지역의 역사적 배경과 문화적 전통을 경험할 수 있으며, 사운드스케이프를 문화 관광자원으로 활용할 수 있는 가능성에 주목하였다. 사운드스케이프는 M. Schafer가 비판적, 미적 관찰 대상이 되는 소리 환경을 설명하기 위해 도입한 개념으로 시각뿐만 아니라, 다양한 감각을 사용함으로써 경관을 새롭게 경험할 수 있는 가능성을 제시하였다. 본 연구는 이러한 이론적 배경을 바탕으로, '평화의 섬'을 비전으로 하고 있는 DMZ 접경지역의 교동도에서 사운드스케이프를 조사, 분석한 후, 지역주민 교육과 방문객 경험을 위한 새로운 문화콘텐츠로 재탄생시키고자 하였다. 교동도는 DMZ 접경지역이자 섬 전체가 민간인 통제구역으로, 한국전쟁과 분단으로 인해 역사적으로 격변을 겪었으며, 최근에는 지역활성화를 위한 민관의 다양한 사업들이 추진되고 있는 지역이다. 특히 한강하구중립수역에 위치한 지리적 특성을 문화적으로 해석하여 '평화의 섬'으로서 새롭게 장소마케팅이 되고 있다. 교동도의 사운드스케이프 조사를 위해 먼저 사운드아티스트와 함께 사운드스케이프의 개념과 기술에 대한 워크샵을 실시하였으며, 이어 관찰조사, 청취조사, 문헌조사를 진행하였다. 녹음결과물은 Schafer의 사운드스케이프 개념에 맞추어 기조음, 신호음, 표식음으로 구분하여 분석하고 사운드맵으로 기록하였으며, 교동도의 지역특성과 비전을 반영하여 사운드스케이프 작곡의 방식으로 재구성하는 스튜디오 작업을 진행하였다. 최종결과물은 '화합과 평화에 대한 희망과 염원'이라는 전체 주제를 바탕으로 '교동도와의 만남', '전쟁과 긴장', '교동도의 일상', '화합과 평화를 찾아서'로 세부 주제를 구성하였고, 전시와 YouTube를 통해 공유하였다. 이를 통해 교동도의 역사 및 지역정체성을 보존하고, 새로운 미래비전을 제시하는 매체로서 사운드스케이프의 가능성을 확인하였다. 본 연구결과물을 교동도에서 역사적, 문화적으로 의미가 있는 기존 장소들을 활용하여 전시함으로써 공간활용을 제고하고, 지역 역사와 문화를 담은 관광자원뿐만 아니라, 교육자원으로 활용할 수 있다는 의의를 가진다.

폴리프로필렌사(絲)칩과 배향사(配向絲)를 결체(結締)한 톱밥보드의 물리적(物理的) 및 기계적(機械的) 성질(性質)에 관(關)한 연구(硏究) (A Study on Physical and Mechanical Properties of Sawdustboards combined with Polypropylene Chip and Oriented Thread)

  • 서진석;이필우
    • Journal of the Korean Wood Science and Technology
    • /
    • 제16권2호
    • /
    • pp.1-41
    • /
    • 1988
  • 톱밥을 보드에 활용(活用)하기 위한 방안(方案)으로서, 톱밥자체의 약(弱)한 결집력(結集力)과 치수불량성(不良性)을 개선(改善)하기 위하여 비(非) 목질계(木質系) 재료(材料)인 폴리프로필렌 사(絲)칩과 배향사(配向絲)를 혼합(混合) 결체(結締)함에 다른 보드의 기초성질(基礎性質)로서 물리적(物理的) 기계적(機械的) 성질(性質)을 고찰(考察)하였는 바, 현재(現在) 제재용(製材用)으로 많이 이용(利用)되고 있는 나왕재(羅王材)(white meranti)의 톱밥에 개질재료(改質材料)로서 비(非) 목질(木質) 계(系) 플라스틱 물질(物質)인 폴리프로필렌 사(絲)를 칩상(狀) 또는 배향사(配向絲)의 형태(形態)로 조제(調製)하여 일반(一般) 성형법(成型法)을 적용(適用)함으로써 톱밥과 결체(結締) 구성(構成)한 톱밥보드를 제조(製造)하였다. 12 및 15%로 하여 구성(構成)하였다. 배향사(配向絲)는 보드폭방향(幅方向)으로 0.5, 1.0 및 1.5cm의 일정(一定)한 간격(間隔)으로 배열(配列)하였다. 위의 조건(條件)에 의(依)해 단(單) 2 3층(層)으로 각기(各己) 구분(區分)제조된 사(絲)칩 또는 배향사(配向絲) 구성(構成) 톱밥보드의 물리적(物理的) 및 기계적(機械的) 성질(性質)을 구명(究明)하였는 바, 그 주요(主要)한 결론(結論)을 요약(要約)하면 다음과 같다. 1. 사(絲)칩 혼합(混合) 단층구성(單層構成)보드의 두께 팽창율(膨脹率)은 톱잡대조(對照)보드의 팽창율보다 모두 낮았다. 사(絲)칩 함량(含量)을 증가(增加) 시킴에 따라서 두께 팽창율은 점차(漸次) 감소(減少)하는 경향이 뚜렷하였다. 한편, 2층구성(層構成)보드는 단층(單層) 구성(構成)보드보다 높은 팽창율을 나타냈으나 대부분이 톱밥대조(對照)보드 보다 팽창율이 낮았다. 3층(層)으로 사(絲)칩구성(構成)한 보드는 톱밥대조(對照)보드보다도 모두 낮은 두께 팽창율을 나타냈다. 2. 사(絲)칩 배향사(配向絲) 구성(構成)보드의 두께 팽창율은 0.5cm 배향간격에서 사(絲)칩함량(含量) 12%와 15%의 길이 1.0cm와 1.5cm로 구성함으로써 단층(單層) 및 3층구성(層構成)보드의 최저치(最低値)보다 더 낮았다. 3. 단층구성(單層構成)보드의 휨강도는 비중(比重) 0.51 구성(構成)보드의 경우 사(絲)칩함량(含量) 3%에서 톱밥대조)對照)보드보다 높은 강도를 나타냈으나, KS F 3104 의 파티클보드 100타입 기준(基準) 값인 80 kgf/$cm^2$에 훨씬 못 미쳤다. 그러나 비중(比重) 0.63 구성(構成)보드에서 함량(含量) 6%의 길이 1.5cm 사(絲)칩 구성과 함량(含量)3% 의 모든 사(絲)칩 길이로 구성한 보드, 그리고 비중(比重) 0.72의 모든 사(絲)칩 구성보드는 KS F 기준값을 훨씬 상회(上廻) 하였다. 2층구성(層構成)보드의 휨강도는 톱밥대조(對照)보드보다도 사(絲)칩구성의 경우 모두 낮았으며 단층구성(單層構成)보드의 휨강도보다도 낮은 값을 나타냈다. 3층구성(層構成)보드의 휨강도는 사(絲)칩 함량(含量) 9% 이하(以下)의 길이 1.5cm 구성보드는 모두 톱밥대조(對照)보드보다 높은 값을 나타냈으며 KSF 기준값을 훨씬 상회(上廻) 하였다. 4. 배향사구성(配向絲構成) 톱밥보드의 경우(境遇), 배향간격(配向間隔)이 좁은 0.5cm에서 가장 높은 휨강도를 나타냈으며, 배향간격이 보다 넓은 1.0cm 와 1.5cm 구성(構成)에서는 휨 강도가 0.5cm 간격 보다 낮았다. 그러나 배향사구성(配向絲構成) 톱밥보드는 모두 톱밥대조(對照)보드 보다 높은 휨강도를 나타냈다. 5. 사(絲칩) 배향사(配向絲) 구성 보드의 휨강도는 거의 대부분(大部分)의 구성보드에서 톱밥대조(對照)보드보다 높은 값을 나타냈으며 KSF 기준값을 훨씬 상회(上廻) 하였다. 특(特)히 배향간격이 좁고, 길이가 긴 사(絲)칩으로 구성한 보드의 휨강도가 높은 값을 나타냈다. 그리고 사(絲)칩을 배향사(配向絲)와 혼합(混合) 구성(構成)할 때 배향사의 간격이 넓어짐에 따라 톱밥과 배향사(配向絲)만으로 구성한 보드보다도 휨 강도가 높아지는 현상(現象)이 나타났다. 6. 단층(單層), 2층(層) 및 3층(層) 구성(構成) 보드의 탄성계수는 대부분(大部分) 톱밥대조(對照)보드 보다 낮은 값을 나타냈다. 그러나 배향사(配向絲) 구성(構成) 톱밥보드에 있어서는, 배향 간격이 0.5, 1.0, 1.5crn로 됨에 따라서 톱밥대조(對照)보드보다도 각각(各各) 20%, 18%, 10% 탄성계수가 증가(增加)되었다. 7. 사(絲)칩 배향사(配向絲) 구성(構成) 보드의 탄성계수(彈性係數)는 배향간격 0.5crn, 1.0cm 및 1.5crn에서 거의 모두 톱밥대조(對照)보드보드보다도 훨씬 높은 값을 나타냈다. 그리고 함량(含量)9% 이하(以下)에서 사(絲)칩길이를 0.5cm이상(以上)으로 구성하였을 때 배향사(配向絲)만을 구성한 톱밥보드보다도 탄성계수가 높아지는 현상(現象)이 나타났는데, 배향(配向)간격이 좁은 경우 사(絲)칩결체(結締)에 의(依)한 탄성계수(彈性係數) 증가효과(增加效果)가 컸다. 8. 사(絲)칩 혼합(混合) 단층구성(單層構成) 보드의 박리저항(剝離抵抗)은 톱밥대조(對照)보드 보다 모두 낮았다. 그러나 비중(比重) 0.63의 사(絲)칩 구성보드는 KS F 3104의 100타입 기준 값인 1.5kgf/$cm^2$를 모두 상회(上廻) 하였고, 비중(比重) 0.72의 사(絲)칩 구성보드는 200타입의 기준값 3kgf/$cm^2$를 상회(上廻)하는 박리저항(剝離抵抗)을 나타냈다. 2층(層), 3층(層) 및 배향구성(配向構成)도 거의 모두 200타입의 기준값 3kgf/$cm^2$를 상회(上廻) 하였다. 9. 단층구성(單層構成)보드의 나사못유지력(維持力)은 사(絲)칩을 혼합 구성한 경우, 대체(大體)로 톱밥대조(對照)보드보다도 낮은 값을 나타냈다. 그러나, 2층(層) 및 3층구성(層構成)보드에서는 사(絲)칩 구성(構成)에 따른 감소경향(減少傾向)이 나타나지 않고 대체로 고른 나사못 유지력을 나타냈다. 또한, 사(絲)칩 배향사(配向絲) 구성(構成)보드에서는 사(絲)칩함량(含量) 9% 이하(以下)에서 거의 모두 톱밥대조(對照)보드 보다도 높은 나사못 유지력을 나타냈다.

  • PDF