• Title/Summary/Keyword: dimensional deviation

Search Result 370, Processing Time 0.031 seconds

Positional symmetry of porion and external auditory meatus in facial asymmetry

  • Choi, Ji Wook;Jung, Seo Yeon;Kim, Hak-Jin;Lee, Sang-Hwy
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.33.1-33.9
    • /
    • 2015
  • Background: The porion (Po) is used to construct the Frankfort horizontal (FH) plane for cephalometrics, and the external auditory meatus (EAM) is to transfer and mount the dental model with facebow. The classical assumption is that EAM represents Po by the parallel positioning. However, we are sometimes questioning about the possible positional disparity between Po and EAM, when the occlusal cant or facial midline is different from our clinical understandings. The purpose of this study was to evaluate the positional parallelism of Po and EAM in facial asymmetries, and also to investigate their relationship with the maxillary occlusal cant. Methods: The 67 subjects were classified into three groups. Group I had normal subjects with facial symmetry ($1.05{\pm}0.52mm$ of average chin deviation) with minimal occlusal cant (<1.5 mm). Asymmetry group II-A had no maxillary occlusal cant (average $0.60{\pm}0.36$), while asymmetry group II-B had occlusal cant (average $3.72{\pm}1.47$). The distances of bilateral Po, EAM, and mesiobuccal cusp tips of the maxillary first molars (Mx) from the horizontal orbital plane (Orb) and the coronal plane were measured on the three-dimensional computed tomographic images. Their right and left side distance discrepancies were calculated and statistically compared. Results: EAM was located 10.3 mm below and 2.3 mm anterior to Po in group I. The vertical distances from Po to EAM of both sides were significantly different in group II-B (p=0.001), while other groups were not. Interside discrepancy of the vertical distances from EAM to Mx in group II-B also showed the significant differences, as compared with those from Po to Mx and from Orb to Mx. Conclusions: The subjects with facial asymmetry and prominent maxillary occlusal cant tend to have the symmetric position of Po but asymmetric EAM. Some caution or other measures will be helpful for them to be used during the clinical procedures.

ABNORMAL GROWTH PATTERN OF HUMAN FETAL MAXILLA WITH CLEFT LIP AND PALATE (구순구개열 태아의 비정상적인 상악골 성장형태에 대한 연구)

  • Kim, Soung-Min;Kim, Jung-Hwan;Kim, Ji-Hyuck;Park, Young-Wook;Lee, Jong-Ho;Lee, Suk-Keun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.3
    • /
    • pp.238-246
    • /
    • 2007
  • This study is aimed to elucidate the abnormal growth pattern of human fetal maxilla with cleft lip and palate (CLP). Total 71 fetal maxillae with CLP were obtained from aborted human fetuses. They were examined radiologically for the dimensional changes of maxillary trapezoid (MT) formed by maxillary primary growth centers (MxPGC)(Lee et al., 1992). In palatal radiogram of the CLP maxilla, the MT was traced by the anterior and posterior MxPGCs, and the dimensions of anterior and posterior maxillary widths, maxillary length, and MT length (MTL), and MT area were measured for evaluation of the basic growth pattern of the developing maxilla. The growth of anterior and posterior MxPGCs was severely retarded in the prenatal maxillae with CLPs, showing abnormal shape of MT. Cleft lip subjects without cleft palate also showed arrested growth of MT. Unilateral cleft lipalveolar cleft or cleft palate (UCL-AC/CP) and bilateral cleft lip-alveolar cleft or cleft palate (BCL-AC/CP) showed enhanced abnormal MT pattern. The abnormality of MT was most marked in BCL-AC/CP. It was also observed that the craniofacial malformations other than CLPs produced abnormal MT. In conclusion, the MT growth of prenatal CLP maxilla was severely arrested and resulting in abnormal MT shape on the palatal radiogram. BCL-AC/CP showed more protruded nasal septum than other types of CLPs, while UCL-AC/CP showed severe deviation of the protruded nasal septum towards the non-cleft side. Cleft lip only subjects also showed the abnormal growth of MT. These data suggest that the MT is primarily involved in CLPs, and MT shape could be utilized as a sensitive indicator for the analysis of maxillary malformation in different types of CLPs.

Effective Method for Analysis of Heterogeneous Porous Media (비균질 다공성 매질의 효율적 해석 방법)

  • Park, Chang-Geun
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.4
    • /
    • pp.459-467
    • /
    • 1998
  • The existing methods to analyze the heterogeneous porous media based on the similar media concept are the microscopic Miller similitude(MiS), the macroscopic Miller similitude(MaS) and the Warrick similitude(WS). The inter-relationship is found such that MiS ⊂ MaS ⊂ (⊂:subset). The proposed method is based ont eh assumption that the scale variables $\alpha$=w and the moisture content is dimensionless by introducing the effective degree of saturation instead of the degree of saturation into WS. The method, without the loss of generality in view of the inspectional analysis, can explain the heterogeneity of the media by using the scale variable $\alpha$ only. The media of $\alpha$=1 (average of $\alpha$) means the equivalent media corresponding to the heterogeneous media, while the standard deviation of $\alpha$ may explain the degree of the heterogeneity of the media under consideration. The hydraulic conductivity of the media with $\alpha$>1 is greater than that of the equivalent media, and the effective moisture content of the media with $\alpha$>1 is also greater. Based on these properties of the scale variable $\alpha$, the ideal vertical one-dimensional heterogeneous porous media is generated by using the technique of random number generation.

  • PDF

Evaluation of Real-time Target Positioning Accuracy in Spinal Radiosurgery (척추방사선수술시 실시간 추적검사에 의한 병소목표점 위치변이 평가)

  • Lee, Dong Joon
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.290-294
    • /
    • 2013
  • Stereotactic Radiosurgery require high accuracy and precision of patient positioning and target localization. We evaluate the real time positioning accuracy of isocenter using optic guided patient positioning system, ExacTrac (BrainLab, Germany), during spinal radiosurgery procedure. The system is based on real time detect multiple body markers attached on the selected patient skin landmarks. And a custom designed patient positioning verification tool (PPVT) was used to check the patient alignment and correct the patient repositioning before radiosurgery. In this study, We investigate the selected 8 metastatic spinal tumor cases. All type of tumors commonly closed to thoracic spinal code. To evaluate the isocenter positioning, real time patient alignment and positioning monitoring was carried out for comparing the current 3-dimensional position of markers with those of an initial reference positions. For a selected patient case, we have check the isocenter positioning per every 20 millisecond for 45 seconds during spinal radiosurgery. In this study, real time average isocenter positioning translation were $0.07{\pm}0.17$ mm, $0.11{\pm}0.18$ mm, $0.13{\pm}0.26$ mm, and $0.20{\pm}0.37$ mm in the x (lateral), y (longitudinal), z (vertical) directions and mean spatial error, respectively. And body rotations were $0.14{\pm}0.07^{\circ}$, $0.11{\pm}0.07^{\circ}$, $0.03{\pm}0.04^{\circ}$ in longitudinal, lateral, table directions and mean body rotation $0.20{\pm}0.11^{\circ}$, respectively. In this study, the maximum mean deviation of real time isocenter positioning translation during spinal radiosurgery was acceptable accuracy clinically.

Positional change in mandibular condyle in facial asymmetric patients after orthognathic surgery: cone-beam computed tomography study

  • Choi, Byung-Joon;Kim, Byung-Soo;Lim, Ji-Min;Jung, Junho;Lee, Jung-Woo;Ohe, Joo-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.13.1-13.8
    • /
    • 2018
  • Background: We evaluated change in the mandibular condyle after orthognathic surgery using cone-beam computed tomography (CBCT) in patients with facial asymmetry. Methods: Thirty patients with skeletal class III malocclusion and mandibular prognathism or facial asymmetry were classified into two groups according to the amount of menton deviation (MD) from the facial midline on anteroposterior (AP) cephalogram: group A (asymmetry, MD ≥ 4 mm; n = 15) and group B (symmetry, MD < 4 mm; n = 15). Position and angle of condylar heads on the axial, sagittal, and coronal views were measured within 1 month preoperatively (T0) and postoperatively (T1) and 6 months (T2) postoperatively. Results: On axial view, both groups showed inward rotation of condylar heads at T1, but at T2, the change was gradually removed and the condylar head returned to its original position. At T1, both groups showed no AP condylar head changes on sagittal view, although downward movement of the condylar heads occurred. Then, at T2, the condylar heads tended to return to their original position. The change in distance between the two condylar heads showed that they had moved outward in both groups, causing an increase in the width between the two heads postoperatively. Analysis of all three-dimensional changes of the condylar head positions demonstrated statistically significant changes in the three different CBCT views in group B and no statistically significant changes in group A. Conclusions: There was no significant difference between the two groups in condylar head position. Because sagittal split ramus osteotomy can be performed without significant change in symmetrical and asymmetrical cases, it can be regarded as an effective method to stabilize the condylar head position in patients with skeletal class III malocclusion and mandibular prognathism or facial asymmetry.

Experimental Study of Collapse Delay Effect of Riprap on Dam Slope (사력댐 사석 보호공의 붕괴 지연 효과에 대한 실험 연구)

  • Jeong, Seokil;Kim, Seung Wook;Kim, Hong Taek;Lee, Seung Oh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.11 no.1
    • /
    • pp.31-38
    • /
    • 2018
  • The 99.1% of small dam and most of the levees in Korea are soil dam which can be constructed with lower cost and less effort compared with ones made of concrete. However, they are so vulnerable to overflow. Sudden collapses of these strucrues lead to increase flow rate rapidly, which may cause catastrophic problems in downstream regions. In this study, the experimental study on the collapse delay effect of riprap that was laid on slope of soil levee was carried out. A prismatic rectangular open channel was used and three different sizes of the riprap were installed on slope of a scaled earth dam. A new formula for the collapse time of the levee with the installation of riprap was presented, using the previous researches and the dimensional analysis. In this process, an unsteady flow condition was considered to derive the deviation time of the riprap. And additional experiments were conducted to understand the effect of reinforcement of riprap, and it was found that the reinforcement of riprap was more effective than twice sizing of intial riprap. If the collapse time is delayed, EAP (Emergency Action Plan) and forecasting can greatly reduce the degree of flood damage. Also, it will be meaningful that the results of this study are used for river design.

Kinematic Characteristics Based on Proficiency In Geoduepyeopchagi in Taekwondo Poomsae Koryo

  • So, Jae Moo;Kang, Sung-Sun;Hong, AhReum;Jung, Jong Min;Kim, Jai Jeong
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.4
    • /
    • pp.343-351
    • /
    • 2016
  • Objective: The purpose of this study was to help improve game performance and provide preliminary data to enhance the efficiency of the kick and stability of the support foot by comparing the kinematic characteristics of the repeated side kick (geodeupyeopchagi) in poomsaeKoryo between expert and non-expert groups. Method: The subjects were divided into 2 groups according to proficiency in Taekwondo, an expert group and a non-expert group (n = 7 in each group), to observe the repeated side-kick technique. Four video cameras were set at a speed of 60 frames/sec and exposure time of 1/500 sec to measure the kinematic factors of the 2 groups. The Kwon3D XPprogramas used to collect and analyze three-dimensional spatial coordinates. Ground reaction force data were obtained through a force plate with a 1.200-Hz frequency. An independent samplesttest was performed, and statistical significance was defined as .05. The SPSS 18.0 software was used to calculate the mean and standard deviation of the kinematic factors and to identify the difference between the experts and non-experts. Results: The angular displacement of the hip joint in both the expert and non-expert groups showed statistical significance on E1 and E4 of the left support foot and E5 of the right foot (p<.05). The angle displacement of the knee joint in both groups showed statistical significance on E4 of the left support foot, and E1 and E2 of the right foot (p<.05). The angular velocity of the lower leg in both groups showed no statistical significance on the left support foot but showed statistical significance on E2 and E6 of the right foot (p<.05). The angular velocity of the foot in both groups showed no statistical significance on the left support foot but showed statistical significance on E2 of the right foot (p<.05). The vertical ground reaction force in both groups showed statistical significance on E2 (p<.05). The center of pressure in all directions in both groups showed statistical significance (p<.5). Conclusion: While performing the repeated side kick (geodeupyeopchagi), the experts maintainedconsistency and stability of the angle of the support leg while the kick foot moved high and fast. On the other hand, the angle of the support foot of non-experts appeared inconsistent, and the kick foot was raised, relying on the support leg, resulting in unstable and inaccurate movement.

Predicting Water Movement in the Soil Profile of Corn Fields with a Computer-Based STELLA Program to Simulate Soil Water Balance (토양수분 수지계산에 의한 옥수수 포장에서의 토양수분 이동 예측)

  • Kim, Won-Il;Jung, Goo-Bok;Lee, Jong-Sik;Kim, Jin-Ho;Shin, Joung-Du;Kim, Gun-Yeob;Huck, M.G.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.38 no.4
    • /
    • pp.222-229
    • /
    • 2005
  • A simplified one-dimensional model STELLA was used to predict soil water movement in lllinois corn fields using soil water balance sheets. It offered the potential to increase understanding of soil nitrate and agrochemical leaching process. The model accounted for aU possible annual inputs and outputs of water from a closed ecosystem as represented by corn fields. Water inputs included precipitation, while outputs included runoff, transpiration, evaporation and drainage. To run the model required daily inputs of two climatic data measurements such as daily precipitation and pan evaporation. Vertical water flow through the soil profile was calculated with first order equation including the difference in hydraulic conductivity and matric potential at the various soil types. The output results included daily changes of water content in the soil layers and daily amount of water losses including run-off, percolation, transpiration. This model was verified using Illinois corn field data for the soil water content measured by neutron scattering methods through 1992 to 1994 growing seasons. Approximately 22 to 78% of simulated water contents agreed with the measured values and their standard deviation, depending on soil types, whereas 30 to 70% of simulated water values agreed with the measured values and their standard deviations depending on soil layers.

Construction of Precise Mine Geospatial Information and Ore Modeling for Smart Mining (스마트마이닝을 위한 정밀 광산공간정보 구축 및 광체 모델링)

  • Park, Joon Kyu;Jung, Kap Yong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.725-731
    • /
    • 2020
  • In mineral resource development, resource exploration is a task to find economical minerals on the surface and underground, and the success rate is low compared to the development and production stages, and it is necessary to collect a lot of data through exploration and accurately analyze the collected information. In this study, mine spatial information was constructed using a 3D (Three-dimensional) laser scanner, and accuracy evaluation was performed to obtain a maximum deviation of 0.140 m and an average of 0.095 m in the X, Y and Z directions, and the possibility of utilizing the construction of mine geospatial information through a 3D laser scanner could be presented. In addition, the ore body modeling was performed by applying the interpolation method of the ore body section using the resource exploration results. The ore body modeling result was superimposed with the modeling result of the mine geospatial information built through the 3D laser scanner to construct the ore body modeling result based on the precise mine geospatial information. The results of ore body modeling based on mine geospatial information built through research can increase the ease of data interpretation and the accuracy of the calculated data, which will greatly increase the efficiency of work related to mineral resource development and mine damage prevention in the future.

Reproducibility evaluation of the use of pressure conserving abdominal compressor in lung and liver volumetric modulated arc therapy (흉복부 방사선 치료 시 압력 기반 복부압박장치 적용에 따른 치료 간 재현성 평가)

  • Park, ga yeon;Kim, joo ho;Shin, hyun kyung;Kim, min soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.71-78
    • /
    • 2021
  • Purpose: To evaluate the inter-fractional position and respiratory reproducibility of lung and liver tumors using pressure conserving type(P-type) abdominal compressor in volumetric modulated arc therapy(VMAT). Materials and methods: Six lung cancer patients and three liver cancer patients who underwent VMAT using a P-type abdominal compressor were included in this study. Cone-beam computed tomography(CBCT) images were acquired before each treatment and compared with planning CT images to evaluate the inter-fractional position reproducibility. The position variation was defined as the difference of position shift values between target matching and bone matching. 4-dimensional cone-beam computed tomography(4D CBCT) images were acquired weekly before treatment and compared with planning 4DCT images to evaluate the inter-fractional respiratory reproducibility. The respiratory variation was calculated by the magnitude of excursions by breathing. Results: The mean ± standard deviation(SD) of overall position variation values, 3D vector in the three translational directions were 1.1 ± 1.4 mm and 4.5 ± 2.8 mm for the lung and liver, respectively. The mean ± SD of respiratory variation values were 0.7 ± 3.4 mm (p = 0.195) in the lung and 3.6 ± 2.6 mm (p < 0.05) in the liver. Conclusion: The use of P-type compressor in lung and liver VMAT was effective for stable control of inter-fractional position and respiratory variation by reproduction of abdominal compression. Appropriate PTV margin must be considered in treatment planning, and image guidance before each treatment are required in order to obtain more stable reproducibility