• Title/Summary/Keyword: dimensional deviation

Search Result 370, Processing Time 0.028 seconds

A comparative study of the deviation of the menton on posteroanterior cephalograms and three-dimensional computed tomography

  • Lee, Hee Jin;Lee, Sungeun;Lee, Eun Joo;Song, In Ja;Kang, Byung-Cheol;Lee, Jae-Seo;Lim, Hoi-Jeong;Yoon, Suk-Ja
    • Imaging Science in Dentistry
    • /
    • v.46 no.1
    • /
    • pp.33-38
    • /
    • 2016
  • Purpose: Facial asymmetry has been measured by the severity of deviation of the menton (Me) on posteroanterior (PA) cephalograms and three-dimensional (3D) computed tomography (CT). This study aimed to compare PA cephalograms and 3D CT regarding the severity of Me deviation and the direction of the Me. Materials and Methods: PA cephalograms and 3D CT images of 35 patients who underwent orthognathic surgery (19 males and 16 females, with an average age of $22.1{\pm}3.3years$) were retrospectively reviewed in this study. By measuring the distance and direction of the Me from the midfacial reference line and the midsagittal plane in the cephalograms and 3D CT, respectively, the x-coordinates ($x_1$ and $x_2$) of the Me were obtained in each image. The difference between the x-coordinates was calculated and statistical analysis was performed to compare the severity of Me deviation and the direction of the Me in the two imaging modalities. Results: A statistically significant difference in the severity of Me deviation was found between the two imaging modalities (${\Delta}x=2.45{\pm}2.03mm$, p<0.05) using the one-sample t-test. Statistically significant agreement was observed in the presence of deviation (k=0.64, p<0.05) and in the severity of Me deviation (k=0.27, p<0.05). A difference in the direction of the Me was detected in three patients (8.6%). The severity of the Me deviation was found to vary according to the imaging modality in 16 patients (45.7%). Conclusion: The measurement of Me deviation may be different between PA cephalograms and 3D CT in some patients.

Hardness Distribution and Dimensional Change after Partial- Hardened Hot Stamping of Automotive Body Part (국부 연화 핫스탬핑 차체 부품의 경도 분포 및 열 변형 거동)

  • Jeong, Woo Chang
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.2
    • /
    • pp.66-73
    • /
    • 2022
  • Partial-hardened hot stamping has been well known to be very effective to absorb more energy in automotive lateral crash. Hardness distribution and dimensional change after partial-hardened hot stamping have been studied to find out effect of thermal deformation of the heated hot stamping die on dimensional accuracy of automotive center pillar. Soft zone of commercial center pillar showed 275~345 in Vickers hardness, indicating bigger non-uniformity which resulted from thermal deformation of heated die. Dimensional changes in soft zone of the commercial center pillar measured by three dimensional scanner were much bigger than that in hard zone. It has been found that hot stamping die compensation considering thermal deformation in soft zone causes a significant decrease in hardness deviation in the soft zone, corresponding to 20 percent of commercial center pillar and subsequently leads to much higher dimensional accuracy.

Multiclass Support Vector Machines with SCAD

  • Jung, Kang-Mo
    • Communications for Statistical Applications and Methods
    • /
    • v.19 no.5
    • /
    • pp.655-662
    • /
    • 2012
  • Classification is an important research field in pattern recognition with high-dimensional predictors. The support vector machine(SVM) is a penalized feature selector and classifier. It is based on the hinge loss function, the non-convex penalty function, and the smoothly clipped absolute deviation(SCAD) suggested by Fan and Li (2001). We developed the algorithm for the multiclass SVM with the SCAD penalty function using the local quadratic approximation. For multiclass problems we compared the performance of the SVM with the $L_1$, $L_2$ penalty functions and the developed method.

THREE-DIMENSIONAL VERIFICATION OF INTRACRANIAL TARGET POINT DEVIATION USING MRI-BASED POLYMER-GEL DOSIMETRY FOR CONVENTIONAL AND FRACTIONATED STEREOTACTIC RADIOSURGERY

  • Lee, Kyung-Nam;Lee, Dong-Joon;Suh, Tae-Suk
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.3
    • /
    • pp.107-118
    • /
    • 2011
  • Conventional (SRS) and fractionated (FSRS) stereotactic radiosurgery necessarily require stringent overall target point accuracy and precision. We determine three-dimensional intracranial target point deviations (TPDs) in a whole treatment procedure using magnetic resonance image (MRI)-based polymer-gel dosimetry, and suggest a technique for overall system tests. TPDs were measured using a custom-made head phantom and gel dosimetry. We calculated TPDs using a treatment planning system. Then, we compared TPDs using mid bi-plane and three-dimensional volume methods with spherical and elliptical targets to determine their inherent analysis errors; finally, we analyzed regional TPDs using the latter method. Average and maximum additive errors for ellipses were 0.62 and 0.69 mm, respectively. Total displacements were 0.92 ${\pm}$ 0.25 and 0.77 ${\pm}$ 0.15 mm for virtual SRS and FSRS, respectively. Average TPDtotal at peripheral regions was greater than that at central regions for both. Overall system accuracy was similar to that reported previously. Our technique could be used as an overall system accuracy test that considers the real radiation field shape.

The Vectra M3 3-dimensional digital stereophotogrammetry system: A reliable technique for detecting chin asymmetry

  • Hansson, Stina;Ostlund, Emil;Bazargani, Farhan
    • Imaging Science in Dentistry
    • /
    • v.52 no.1
    • /
    • pp.43-51
    • /
    • 2022
  • Purpose: The aim of this study was to evaluate the reliability of the Vectra M3 (3D Imaging System; Canfield Scientific, Parsippany, NJ, USA) in detecting chin asymmetry, and to assess whether the automatic markerless tracking function is reliable compared to manually plotting landmarks. Materials and Methods: Twenty subjects (18 females and 2 males) with a mean age of 42.5±10.5 years were included. Three-dimensional image acquisition was carried out on all subjects with simulated chin deviation in 4 stages (1-4 mm). The images were analyzed by 2 independent observers through manually plotting landmarks and by Vectra software auto-tracking mode. Repeated-measures analysis of variance and the Tukey post-hoc test were performed to evaluate the differences in mean measurements between the 2 operators and the software for measuring chin deviation in 4 stages. The intraclass correlation coefficient (ICC) was calculated to estimate the intra- and inter-examiner reliability. Results: No significant difference was found between the accuracy of manually plotting landmarks between observers 1 and 2 and the auto-tracking mode (P=0.783 and P=0.999, respectively). The mean difference in detecting the degree of deviation according to the stage was <0.5 mm for all landmarks. Conclusion: The auto-tracking mode could be considered as reliable as manually plotted landmarks in detecting small chin deviations with the Vectra® M3. The effect on the soft tissue when constructing a known dental movement yielded a small overestimation of the soft tissue movement compared to the dental movement (mean value<0.5 mm), which can be considered clinically non-significant.

Prediction of Thermal Load Distribution and Temperature of the Superheater in a Tangentially Fired Boiler (접선 연소식 보일러의 최종 과열기 열부하 분포 및 튜브 온도 예측에 관한 연구)

  • Park, Ho-Young;Sea, Sang-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.7
    • /
    • pp.478-485
    • /
    • 2008
  • The extreme steam temperature deviation experienced in the superheater of a tangentially fired boiler can seriously affect its economic and safe operation. This temperature deviation is one of the main causes of boiler tube failures. The steam temperature deviation is mainly due to the thermal load deviation in the lateral direction of the superheater. The thermal load deviation consists of several causes. One of the causes is the non-uniform heat flow distribution of burnt gas on the superheater tube system. This distribution is very difficult to measure in situ using direct experimental techniques. So, we need thermal load model to estimate the tube temperature. In this paper, we propose a thermal load distribution model by using CFD analysis and plant data. We successfully predict the tube temperature and the steam flow rate in a final superheater system from the thermal load model and one dimensional heat-flow system analysis. The proposed model and analysis method would be valuable in preventing the frequent tube failure of the final superheater tubes.

Deviation of landmarks in accordance with methods of establishing reference planes in three-dimensional facial CT evaluation

  • Yoon, Kaeng Won;Yoon, Suk-Ja;Kang, Byung-Cheol;Kim, Young-Hee;Kook, Min Suk;Lee, Jae-Seo;Palomo, Juan Martin
    • Imaging Science in Dentistry
    • /
    • v.44 no.3
    • /
    • pp.207-212
    • /
    • 2014
  • Purpose: This study aimed to investigate the deviation of landmarks from horizontal or midsagittal reference planes according to the methods of establishing reference planes. Materials and Methods: Computed tomography (CT) scans of 18 patients who received orthodontic and orthognathic surgical treatment were reviewed. Each CT scan was reconstructed by three methods for establishing three orthogonal reference planes (namely, the horizontal, midsagittal, and coronal reference planes). The horizontal (bilateral porions and bilateral orbitales) and midsagittal (crista galli, nasion, prechiasmatic point, opisthion, and anterior nasal spine) landmarks were identified on each CT scan. Vertical deviation of the horizontal landmarks and horizontal deviation of the midsagittal landmarks were measured. Results: The porion and orbitale, which were not involved in establishing the horizontal reference plane, were found to deviate vertically from the horizontal reference plane in the three methods. The midsagittal landmarks, which were not used for the midsagittal reference plane, deviated horizontally from the midsagittal reference plane in the three methods. Conclusion: In a three-dimensional facial analysis, the vertical and horizontal deviations of the landmarks from the horizontal and midsagittal reference planes could vary depending on the methods of establishing reference planes.

A Study on the Scour Depth Equation in Bight River (하천 만곡부에서의 세굴심 산정식에 관한 연구)

  • Choi, Han-Kuy;Park, Je-Wan;Park, Soo-Jin
    • Journal of Industrial Technology
    • /
    • v.32 no.A
    • /
    • pp.47-55
    • /
    • 2012
  • Currently, we only estimate the average flood water level by the cross-sections of the river using one-dimensional numerical analysis when establishing the basic plans. However, the reliability decreases when it comes to the river bend. In river bend, the difference of water-level between the inside and the outside of the river arises by centrifugal force. And it is estimated less than what it could be estimated when establishing the plan with average estimate of flood level. It is apprehended that the exterior of the river will be under-constructed when establishing the scour depth only with the mean depth. In the case of local scour of the abutment, it is difficult to estimate its depth precisely, and it tends to be over-estimated in the case of the empirical formulas. Therefore, the modification considering the deviation of the water depth of the exterior of the river bend is needed. In observing the deviation of each formula in river bend, it is found: Andru's formula for 58%, followed by the Laursen's for 26%, and the C.S.U's for 17% in pier, while it is 44% for Froehlich's formula in abutment. Under the 500CMS of the flood discharge, the deviation of the scour depth between pier and abutment was about 10 %. However, in further flood discharge, it shows 24~58% the biggest in deviation of piers. It is concluded that the scour depth estimate should be done with 2-dimensional numerical analysis.

  • PDF

Analysis of Facial Asymmetry with Three-Dimensional Morphometry (3차원 영상에 의한 안면 비대칭의 분석)

  • Cho, Hong-Kyu
    • Journal of Technologic Dentistry
    • /
    • v.27 no.1
    • /
    • pp.27-39
    • /
    • 2005
  • This study is to show the qualitative analytic methods of facial asymmetry with three-dimensional morphometry and find out asymmetry change resulted from enlarging three local regions. Steel balls (1.2mm in diameter) were attached in twenty seven landmarks of a symmetrical artificial human skull. This artificial human skull was used as experimental materials. Twelve different asymmetrical artificial human skulls were formed by gradually enlarging the mandibular body length, gonial angle, and ramus height of the left hemiface. From the three-dimensional morphometry of each skull type, nine local area measurements and three total sum area measurements(representing the mandibular area, maxillary area, and lower facial area) were acquired and made into the surface area asymmetry degree. Menton deviation itself was used as the surface area asymmetry degree while right-left percentages were used in the other measurements. These surface area asymmetry degrees were compared with each other to find out asymmetry change according to the degree of actual facial asymmetry. Through the statistical analysis, following results were obtained. The results were as follows: 1. Left maxillary area of artificial human skull was 7.13$\pm$0.26% larger while mandibular area was 4.14$\pm$0.12% smaller than each those of right hemiface. After all, left lower facial area was 1.44$\pm$0.07% larger than those of right hemiface.(n=7). 2. Among the reduce rates of surface area asymmetry degree resulted from enlarging three local regions, ramus height was similar to mandibular body length while it was bigger than those of gonial angle. 3. Among the increase rates of menton deviation resulted from enlarging the local regions, ramus height was the biggest, mandibular body length was the second and gonial angle was the smallest. These results suggest that three-dimensional morphometry can be used to qualitatively analyse facial asymmetry and the asymmetry degree is more influenced by enlarging the ramus height, mandibular body length than those of gonial angle.

  • PDF

Three-dimensional analysis of the outcome of different scanning strategies in virtual interocclusal registration

  • Jiansong, Mei;Liya, Ma;Jiarui, Chao;Fei, Liu;Jiefei, Shen
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.369-378
    • /
    • 2022
  • PURPOSE. The purpose of this in vitro study was to assess whether scanning strategies of virtual interocclusal record (VIR) affect the accuracy of VIR during intraoral scanning. MATERIALS AND METHODS. Five pairs of reference cubes were added to the digital upper and lower dentitions of a volunteer, which were printed into resin casts. Subsequently, the resin casts were articulated in the maximal intercuspal position in a mechanical articulator and scanned with an industrial computed tomography system, of which the VIR was served as a reference VIR. The investigated VIR of the upper and lower jaws of the resin master cast were recorded with an intraoral scanner according to 9 designed scanning strategies. Then, the deviation between the investigated VIRs and reference VIR were analyzed, which were measured by the deviation of the distances of six selected reference points on the upper reference cubes in each digital cast to the XY-plane between the investigated VIRs and reference VIR. RESULTS. For the deviation in the right posterior dentitions, RP group (only scanning of right posterior dentitions) showed the smallest deviation. Besides, BP group (scanning of bilateral posterior dentitions) showed the smallest deviation in the left posterior dentitions. Moreover, LP group (scanning of left posterior dentitions) showed the smallest deviation in the anterior dentitions. For the deviation of full dental arches, BP group showed the smallest deviation. CONCLUSION. Different scanning strategies of VIR can influence the accuracy of alignment of virtual dental casts. Appropriate scanning strategies of VIR should be selected for different regions of interest and edentulous situations.