• 제목/요약/키워드: dilute-and-shoot LC-MS/MS

검색결과 4건 처리시간 0.021초

A Dilute-and-Shoot LC-MS/MS Method for Screening of 43 Cardiovascular Drugs in Human Urine

  • Pham, Thuy-Vy;Lee, Gunhee;Mai, Xuan-Lan;Le, Thi-Anh-Tuyet;Nguyen, Thi Ngoc Van;Hong, Jongki;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • 제12권1호
    • /
    • pp.1-10
    • /
    • 2021
  • A simple, specific, and economical LC-MS/MS method was investigated for the screening of 43 prescribed antihypertensive and related drugs in human urine. The urine samples were simply prepared by diluting and mixing with internal standard before directly introduced to the LC-MS/MS system, which is fast, straightforward, and cost-effective. Fractional factorial, Box-Behnken, and I-optimal design were applied to screen and optimize the mass spectrometric and chromatographic factors. The analysis was carried out on a triple quadrupole mass spectrometer system utilizing multiple reaction monitoring with positive and negative electrospray ionization method. Chromatographic separation was performed on a Thermo Scientific Accucore RP-MS column (50 × 3.0 mm ID., 2.6 ㎛) using two separate gradient elution programs established with the same mobile phases. Chromatographic separation was performed within 12 min. The optimal method was validated based on FDA guideline. The results indicated that the assay was specific, reproducible, and sensitive with the limit of detection from 0.1 to 50.0 ㎍/L. The method was linear for all analytes with coefficient of determination ranging from 0.9870 to 0.9981. The intra-assay precision was from 1.44 to 19.87% and the inter-assay precision was between 2.69 and 18.54% with the recovery rate ranges from 84.54 to 119.78% for all drugs measured. All analytes in urine samples were stable for 24 h at 25℃, and for 2 weeks at -60℃. The developed method improves on currently existing methods by including larger number of cardiovascular medications and better sensitivity of 12 analytes.

시료 희석 직접 주입 LC-MS/MS를 이용한 법화학 수용액 시료 중 카페인 신속 분석 (Rapid Determination of Caffeine in Forensic Aqueous Sample by Dilute and Shoot LC-MS/MS)

  • 최윤정;김희승;인문교;김진영
    • 약학회지
    • /
    • 제60권3호
    • /
    • pp.112-117
    • /
    • 2016
  • A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of caffeine in forensic aqueous sample. The centrifuged sample ($100{\mu}l$) was diluted 50-fold with distilled water. The diluted sample ($400{\mu}l$) was then diluted further with $200{\mu}l$ of 0.1% formic acid solution and $400{\mu}l$ of acetonitrile containing 500 ng of caffeine-(3-methyl-$^{13}C_3$) prior to LC-MS/MS analysis. The mobile phase was composed of 0.1% formic acid in distilled water (A) and acetonitrile (B). Chromatographic separation was performed by using a Zorbax SB-C18 ($100mm{\times}2.1mm$ i.d., $3.5{\mu}m$) column and caffeine was eluted within 1.1 min. Linear least-squares regression with a 1/x weighting factor was used to generate a calibration curve with the coefficients of determination ($r^2=0.9983$). The lower limit of quantification was $25ng/ml$ for the analyte. The process efficiency was 98.6~100.1%. Intra- and inter-day precisions were not more than 2.1% and 1.7%, while intra- and inter-day accuracies were ranged from -6.8 to 4.5%, respectively. The suitability of the method was examined by analyzing unknown forensic aqueous samples.

Simultaneous Determination of Statins in Human Urine by Dilute-and-Shoot-Liquid Chromatography-Mass Spectrometry

  • Jang, Haejong;Mai, Xuan-Lan;Lee, Gunhee;Ahn, Jae Hyoung;Rhee, Jongsook;Truong, Quoc-Ky;Vinh, Dinh;Hong, Jongki;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • 제9권4호
    • /
    • pp.95-99
    • /
    • 2018
  • An innovative, simple, and rapid assay method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated for the simultaneous determination of eight statin drugs in human urine. A simple sample clean-up procedure using the "dilute and shoot" (DAS) approach enabled a fast and reliable analysis. The influence of the dilution factor was investigated to ensure detectability and reduce the matrix effect. Chromatographic separation was performed on a Phenomenex Kinetex C18 column ($50{\times}3.0mm$ i.d., $2.6{\mu}m$) using an elution gradient of mobile phase A composed of 0.1% acetic acid, and mobile phase B composed of acetonitrile, at a flow rate of 0.35 mL/min. Quantitation was performed on a triple quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode using electrospray ionization in positive ion mode. The total chromatographic run time was 15 min. The method was validated for selectivity, sensitivity, recovery, linearity, accuracy, precision, and stability. The present method was successfully applied to the analysis of Rosuvastatin in urine samples after oral administration to healthy human subjects.

시료 희석 주입 LC-MS/MS를 이용한 소변 중 메스암페타민, 4-하이드록시메스암페타민, 암페타민 및 4-하이드록시암페타민 동시 분석 (Determination of methamphetamine, 4-hydroxymethamphetamine, amphetamine and 4-hydroxyamphetamine in urine using dilute-and-shoot liquid chromatography-tandem mass spectrometry)

  • 허보름;권남희;김진영
    • 분석과학
    • /
    • 제31권4호
    • /
    • pp.161-170
    • /
    • 2018
  • 메스암페타민(methamphetamine, MA)과 암페타민(amphetamine, AP)은 전세계적으로 널리 퍼진합성 흥분제로 보건 및 사회 문제, 경제적 비용 발생 등의 다양한 문제를 일으킨다. 또한 이러한 마약은 중독 및 남용 가능성이 매우 높기 때문에 확산 방지를 위한 방안의 하나로 복용자의 생체시료에서 이들 마약을 검출하기 위한 분석법 개발이 필요하다. 따라서 본 연구에서는 액체크로마토그래피-질량분석법(liquid chromatography-tandem mass spectrometry, LC-MS/MS)를 이용하여 소변에서 MA와 4-하이드록시메스암페타민(4-hydroxymethamphetamine, 4HMA), AP, 4-하이드록시암페타민(4-hydroxyamphetamine, 4HA)을 동시에 분석할 수 있는 분석법을 개발하였고 유효성 평가를 수행하였다. 전처리 시간 단축을 위해 50000 g에서 3 min 동안 초고속원심분리 후 시료 희석 주입법을 이용하여 LC-MS/MS에 주입하였다. 분리관은 역상 C18 컬럼을 사용하였고, 정량분석을 위해 MRM (multiple reaction monitoring) 모드를 적용하였다. 가중계수 $1/x^2$에서 정량 범위는 MA는 10-2500 ng/mL, AP는 1.0-800 ng/mL, 4HA와 4HMA는 2.0-200 ng/mL로 설정하였고, 검량선의 직선성은 결정계수($r^2$)를 구하여 평가하였다. 초고속원심분리법의 효율성을 확인하기 위해 전처리 과정으로 시린지 필터(membrane-filtration)를 적용한 결과와 비교하였고, 그 결과 분석물질에 따라 6-15 % 성능이 우수한 것으로 나타났다. 일내(intra-day)와 일간(inter-day) 정밀도는 6.6 % 미만이었고, 정확도는 -14.9-11.3 % 였다. 최저정량한계(LLOQ)는 2.0 ng/mL (4HA 및 4HMA), 1.0 ng/mL (AP), 10 ng/mL (MA)로 확인되었다. 선택성, 검출한계, 희석무결성, 기질효과, 효율성, 안정성을 평가한 결과 만족스러운 측정값을 얻었다. 또한 개발된 분석법을 마약 복용자의 소변에 적용하여 분석법의 유용성을 확인하였다.