• Title/Summary/Keyword: digital protection relay

Search Result 86, Processing Time 0.027 seconds

Development of compression method for fault data of digital protection relay using wavelet transforms (웨이블렛 변환을 이용한 디지털 보호계전기용 고장전류 데이터 압축기법 개발)

  • Choi, Ho-Woong;Kim, Yoon-Hoe;Kim, Byung-Jin;Kim, Bo-In;Kim, Jung-Han
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.283-285
    • /
    • 2005
  • Wavelet transforms provide basis functions for time-frequency analysis and have properties that are particularly useful for the compression of analogue point on wave transient and disturbance power system signals. This paper evaluates the compression properties of the discrete wavelet transform using actual power system data. The results presented in the paper indicate that reduction ratios up to 10:1 with acceptable distortion are achievable. This paper discussed the application of the reduction method for fault analysis and protection assessment.

  • PDF

Development of User-defined Components for Dynamic Test of Distance Relay Models Using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 거리계전기 동특성 시험에 관한 컴포넌트 모델 개발)

  • Lee, Hong-Hak;Lee, Tae-Young;Kim, Ho-Pyo;Nho, Jang-Hyun;Kang, Kun-Soo;Jang, Sung-Hoon;Lee, Jae-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.242-244
    • /
    • 2003
  • The functional test of protection relays is divided into two kind of test types; the steady-state test and dynamic test. Because the steady-state test is comparatively easy, this test is used to test the characteristics of the relaying elements, operating values, resetting values and etc. using equipment such as Doble. But the dynamic test has to be performed on the test environment with RTDS(real time digital simulator) because of the dynamic characteristics of real protection relays. Therefore, it is not usually easy to perform dynamic test of relays using power system simulation tool based on PC(personal computer) such as PSCAD/EMTDC. This paper discusses how to develop and implement a test model and user-defined components that can be performed dynamic test using PSCAD/EMTDC.

  • PDF

A study on the protection coordination by using the digital relay in distribution network (Digital 계전기를 이용한 배전선로 보호협조방안)

  • Lee, Sang-Ho;Seol, Leel-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.262-264
    • /
    • 2005
  • 최근 IT산업의 급격한 부상으로 전력산업에서도 운영시스템이나 설비들이 통합되거나 소형화 및 다양한 가능을 보유하는 둥 많은 변화가 진행되고 있다. 전국의 많은 154kV 배전변전소에는 기존의 유도원판형 보호계전기가 점차 철거되고 기계적인 동작시간차를 고려하지 않아도 되는 디지털보호계전기로 교체되어 있는 중이다. 따라서 배전선로 보호협조 운영기준은 유도원판형 보호계전기만을 고려하여 제정되어 있기 때문에 합리적인 배전계통운영을 위하여 보호협조 운영기준은 현실에 알맞도록 개선되어야 할 것이다. 이 논문에서는 배전 변전소에서 사용중인 디지털보호계전기를 소개하고, 도입에 따른 배전선로 보호협조 방안을 제시하고자 한다.

  • PDF

Digital Relaying Algorithm for Power Transformer Protection using Fuzzy Logic Approach

  • Park, Chul-Won;Shin, Myong-Chul
    • KIEE International Transactions on Power Engineering
    • /
    • v.2A no.4
    • /
    • pp.153-159
    • /
    • 2002
  • Power transformer protective relay should block the tripping during magnetizing inrush and rapidly operate the tripping during internal faults. Recently, the frequency environment of power system has been made more complicated and the quantity of 2nd frequency component in inrush state has been decreased because of the improvement of core steel. And then, traditional approaches will likely be maloperate in the case of magnetizing inrush with low second harmonic component and internal faults with high second harmonic component. This paper proposes a new relaying algorithm to enhance the fault detection sensitivities of conventional techniques by using a fuzzy logic approach. The proposed fuzzy based relaying algorithm consists of flux-differential current derivative curve, harmonic restraint, and percentage differential characteristic curve. The proposed relaying was tested with relaying signals obtained from EMTP simulation package and showed a fast and accurate trip operation.

A Development of the Digital Switchboard for the High Voltage Customer (고압전자식 배전반 개발)

  • Byun, Young-Bok;Joe, Ki-Youn;Jyung, Je-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.803-805
    • /
    • 1993
  • This paper describes the development of a digital multifunction controller for the protection, measurement and control of the high voltage customer switchboard. The magnitude of the fundamental component is estimated using a simple filter based on cross-correlation with a heptagonal wave. The characteristics of flexible relay functions such as adjustable pickup and time-dial settings, various time-magnitude curve and directional capability including measurement functions are presented. The controller implementation is carried out on two microprocessors for real time operation.

  • PDF

Advanced DC Offset Removal Filter of High-order Configuration (고차 구성의 개선된 직류 옵셋 제거 필터)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.1
    • /
    • pp.12-17
    • /
    • 2013
  • Fault currents are expressed as a combination of harmonic components and exponentially decaying DC offset components, during the occurrence of fault in power system. The DC offset components are included, when the voltage phase angle of fault inception is closer to $0^{\circ}$ or $180^{\circ}$. The digital protection relay should be detected quickly and accurately during the faults, despite of the distortions of relaying signal by these components. It is very important to implement the robust protection algorithm, that is not affected by DC offset and harmonic components, because most relaying algorithms extract the fundamental frequency component from distorted relaying signal. So, In order to high performance in relaying, advanced DC offset removal filter is required. In this paper, a new DC offset removal filter, which is no need to preset a time constant of power system and accurately estimate the DC offset components with one cycle of data, is proposed, and compared with the other filter. In order to verify performance of the filter, we used collecting the current signals after synchronous machine modeling by ATPDraw5.7p4 software. The results of simulation, the proposed DC offset removal filter do not need any prior information, the phase delay and gain error were not occurred.

Travelling Wave Technique for Close-Up Fault Protection (진행파를 이용한 근접사고 거리계전 방식)

  • Kim, Gon-Wook;Kang, Sang-Hee;Park, Jong-Keun;Kim, Il-Dong;Yun, Man-Cheol;Kwon, Wook-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.202-205
    • /
    • 1990
  • In this paper the development of new technique based on the travelling-wave information contained in the post fault voltage and current signals has been presented. To develop fault location methods which can cope with close-up fault and zero-inception angle problems, magnitude of the backward wave has been used. The technique developed can be incorporated in a generalized algorithm for application as a high speed distance scheme. In this way some of the problems and limitations associated with travelling wave schemes are avoided. Verification of the relay operating principles is presented through digital computer numerical simulation using an electromagnetic transient program(EMTP) in conjunction with simulation of the proposed algorithms.

  • PDF

Computer Based Simulation for Digital Differential Protection Relay of Power Transformer (컴퓨터기반의 변압기 디지털 비율차동계전기 시뮬레이션 알고리즘 개발)

  • Park, Jin-Soo;Cheon, Young-Sig;Park, Il-Ho;Park, Gwan-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.762-763
    • /
    • 2011
  • 19세기말에 차동보호계전방식이 이미 적용되었고 시스템 보호에 가장 먼저 사용되는 방식 중에 하나였다. 이 방식은 고장전력설비의 기기를 보호하기위해 전류의 입출력값을 비교함으로 고장을 검출하는 방법을 사용한다. 결과적으로 비율차동보호방식은 완벽하게 고장구간을 검출할 수 있으므로 전력설비의 중요기기의 주보호로 적합한 시스템이라고 볼 수 있다. 본 논문 변압기의 내/외부사고유형에 따른 전자기계식과 디지털 보호계전기의 동작특성을 컴퓨터기반의 해석 S/W를 이용하여 모델링과 동작특성에 대한 분석을 통해 보호계전기 동작특성의 신뢰성검증과 전력계통을 시뮬레이션하기 위해 구성하였다. 특히, 비율차동특성 보호 알고리즘을 계전기별로 모듈화하기 위한 기본 구조설계에 초점을 맞추었고 외부사고에 대해 각 보호계전기 동작특성을 비교함으로써 보호계전기 응답특성에 검증하는 기초 데이터를 생성하는 과정도 기술하였다.

  • PDF

VERIFICATION OF PLC PROGRAMS WRITTEN IN FBD WITH VIS

  • Yoo, Jun-Beom;Cha, Sung-Deok;Jee, Eun-Kyung
    • Nuclear Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.79-90
    • /
    • 2009
  • Verification of programmable logic controller (PLC) programs written in IEC 61131-3 function block diagram (FBD) is essential in the transition from the use of traditional relay-based analog systems to PLC-based digital systems. This paper describes effective use of the well-known verification tool VIS for automatic verification of behavioral equivalences between successive FBD revisions. We formally defined FBD semantics as a state-transition system, developed semantic-preserving translation rules from FBD to Verilog programs, implemented a software tool to support the process, and conducted a case study on a subset of FBDs for APR-1400 reactor protection system design.

Development of Rogowski-Coil Type CT for Application in 170kV GIS (170kV GIS용 Rogowski coil형 CT개발)

  • Chung, Y.H.;Kim, J.B.;Song, W.P.;Kim, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.479-481
    • /
    • 2001
  • Traditionally, instrument transformer of the ferromagnetic core type have been used for measuring current in GIS(Gas Insulated Switchgear). Recently, with the introduction of digital technology at the protection relay or measurement device level, the use of new current sensor can be foreseen. Current measurement by means of Rogowski coil is just one illustration of this. This paper describes the progress of development of Rogowski-coil type CT for application in 170kV GIS.

  • PDF