• 제목/요약/키워드: digital detector

검색결과 551건 처리시간 0.026초

Digital Tomosynthesis using a Flat-panel Detector based Micro-CT

  • Mandai, Koushik Kanti;Choi, Jeong-Min;Cho, Min-Hyoung;Lee, Soo-Yeol
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권5호
    • /
    • pp.364-370
    • /
    • 2008
  • Recent development in large area flat-panel x-ray detector technology enables clinical application of digital tomosyntesis. Unlike conventional motion tomography using x-ray films, flat-panel x-ray detectors provide projection images in digital formats so that tomographic images can be synthesized in a more flexible way. For the digital tomosynthesis, precise movements of the x-ray source and the x-ray detector with respect to a fulcrum point are necessary. In this study, we apply the digital tomosynthesis technique to the flat-panel detector based micro-CT in which the flat-panel detector and the x-ray source rotate together on a circular arc. The experimental results suggest that flat-panel detector based 3D CTs can be used for digital tomosynthesis in the clinical environment.

a-Se을 이용한 디지털 X-선 검출기의 Discharge Erasing Method에 관한 연구 (Study of Discharge Erasing Method of a-Se based Digital X-ray Detector)

  • 이동길;박지군;최장용;강상식;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.395-398
    • /
    • 2002
  • Many research group started study to develope x-ray detector using thin film transistor from 1970. But realization of TFT based x-ray detector development was caused by progress of thin film transistor liquid crystal display(TFTLCD) device technology in 1990. The main current of TFT technology is display device. Research results expend TFT technology field from display device to sensor manufacture technology. These days many research group in the world realize various digital x-ray detector. In this study, We compare discharge erasing method to visible light erasing method in a-Se based digital x-ray detector. Visible light erasing method is known reset process in direct conversion x-ray detector. Digital x-ray detector using visible light erasing method is not adaptive for conventional x-ray device, because of its thickness. And it is not avaliable for real-time imaging for digital fluoroscopy, because of its long reset time. In this study we overcome these limitations and show new idea for real-time imaging method.

  • PDF

배관 원둘레 이음 용접부의 디지털 방사선 투과 검사 적용을 위한 커브드 및 평면형 검출기의 영상 비교 (Image Comparison of Curved and Flat Panel Detectors for the Application of Digital Radiography Testing in Pipe Welds)

  • 양진욱;조갑호;남문호
    • 한국방사선학회논문지
    • /
    • 제16권5호
    • /
    • pp.585-594
    • /
    • 2022
  • 현재 주로 사용되고 있는 디지털 방사선 검사용 검출기는 평면형의 구조를 가진 검출기로 이루어져 있어 곡률을 가진 검사 대상물의 디지털 방사선 검사 시 완전한 밀착이 불가능 하였다. 본 연구는 산업현장에서 배관 용접부를 대상으로 한 디지털 방사선 투과 검사 시 디지털 영상의 상질 개선을 위하여 곡률에 밀착이 가능한 커브드 형태의 검출기를 제작하였고, 공칭 두께가 각기 다른 6" 배관을 대상으로 평면형 검출기와 커브드 검출기를 사용한 디지털 방사선 영상을 획득하였다. 실험 결과, 평면형 검출기는 배관과 완전한 밀착이 되지 않아 배관 외곽부와 검출기 사이의 틈이 생기게 되고, 이로 인해 불선명도 차이가 생기면서 디지털 영상의 확산이 발생하는 것을 확인하였다. 반면, 커브드형 검출기는 배관 외곽부와 검출기 사이의 틈을 최소화 하여 평면형 검출기에 비해 디지털 영상의 확산이 적은 것을 확인하였다. 영상의 확신이 클수록 상질의 저하 및 판독의 오류가 발생할 수 있기 때문에 검사 대상물과 밀착이 가능한 검출기의 사용시 기존 평면형 검출기 보다 양질의 영상을 획득 가능할 것으로 사료된다.

Array Type의 Single Photon Counting Digital X-ray Detector의 제작 및 특성 평가 (Fabrication and Characterization of Array Type of Single Photon Counting Digital X-ray Detector)

  • 서정호;임현우;박진구;허영;전성채;김봉회
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.32-32
    • /
    • 2008
  • X-ray detector는 의료용, 산업용 등 다양한 분야에서 사용되어지고 있으며 기존의 Analog X-ray 방식의 환경오염, 저장공간 부족, 실시간 분석의 어려움 등의 문제점들을 해결하기 위하여 Digital X-ray로의 전환과 연구가 활발하며 이에 따른 관심도 높아지고 있는 살점이다. Digital X-ray detector는 p-영역과 n-영역 사이에 아무런 불순물을 도핑하지 않은 진성반도체(intrinsic semiconductor) 층을 접합시킨 이종접합 PIN 구조의 photodiode 이다. 이 소자는 역바이어스를 가해주면 p영역과 n영역 사이에서 캐리어 (carrier)가 존재하지 않는 공핍 영역이 발생하게 된다. 이런 공핍 영역에서 광흡수가 일어나면, 전자-정공 쌍이 발생한다. 그리고, 발생한 전자-정공 쌍에 전압이 역방향으로 인가되는 경우, 전자는 양의 전극으로 이동하고, 정공은 음의 전극으로 이동한다. 이와 같이, 발생한 캐리어들을 검출하여 전기적인 신호로 변환 시킨다. 고해상도의 Digital X-ray detector를 만들기 위해서는 누설전류에 의한 noise 감소와 소자의 높은 안정성과 내구성을 위한 높은 breakdown voltage를 가져야 한다. 본 연구에서는 Digital X-ray detector의 leakage current 감소와 breakdown voltage를 높이기 위하여 guradring과 gettering technology를 사용하여 전기적 특성을 분석하였다. 기판으로는 $10k\Omega{\cdot}cm$ resistivity를 갖으며, n-type <111>인 1mm 두께의 4인치 Si wafer를 사용하였다. 그리고 pixel pitch는 $100{\mu}m$이며 active area는 $80{\mu}m{\times}80{\mu}m$$32\times32$ array를 형성하여 X-ray를 조사하여 소자의 특성을 평가 하였다.

  • PDF

SDR 시스템에서 GPU를 사용한 Lattice Reduction-aided 검출기 구현 (Implementation of Lattice Reduction-aided Detector using GPU on SDR System)

  • 김태현;이현석;최승원
    • 디지털산업정보학회논문지
    • /
    • 제7권3호
    • /
    • pp.55-61
    • /
    • 2011
  • This paper presents an implementation of Lattice Reduction (LR)-aided detector for Multiple-Input Multiple-Output (MIMO) system using Graphics Processing Unit (GPU). GPU is a parallel processor which has a number of Arithmetic Logic Units (ALUs), thus, it can minimize the operation time of LR algorithm through the parallelization using multiple threads in the GPU. Through the implemented LR-aided detector, we verify that the LR-aided detector operates a lot faster than Maximum Likelihood (ML) detector. The implemented LR-aided detector has been applied to WiMAX system to show the feasibility of its real-time processing. In addition, we demonstrate that the processing time can be reduced at the cost of 3dB SNR loss by limiting the repeating loop in Lenstra-Lenstra-Lovasz (LLL) algorithm which is frequently used in LR-aided detector.

경수로 제어봉구동장치제어계통의 영점위상탐지기 성능개선에 관한 연구 (Study for improvement of zero-cross detector of control element drive mechanism control system in PWR)

  • 김병문;이병주;한상준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.609-611
    • /
    • 1996
  • Zero-Cross Detector makes pilot signal to control the power to CEDM(Control Element Drive Mechanism). Existing Zero-Cross Detectors has had a problem which can cause unexpected reactor trip resulted from fluctuating frequency of input signal coming from M/G Set. The existing Zero-Cross Detector can't work properly when power frequency is varying because it was designed to work under stable M/G Set operation, and produces wrong pilot signal and output voltage. In this report the Zero-Cross Detector is improved to resolve voltage fluctuating problem by using new devices such as digital noise filtering circuit, variable cycle compensator and alarm circuit. And through the performance verification it shows that new circuit is better than old one. If suggested detector is applied to plant, it is possible to use it under House Load Operation because stable voltage can be generated by new Zero-Cross Detector.

  • PDF

비정질 평판형 측정기를 이용한 디지털 방사선 영상의 특징 (Imaging Characteristics of Digital Chest Radiography with an Amorphus Silicon Flat Panel Detectors)

  • 정회원;김정민;정만희;임은경
    • 대한디지털의료영상학회논문지
    • /
    • 제8권1호
    • /
    • pp.27-32
    • /
    • 2006
  • The rapid development in digital acquisition technology in radiography has not been accompanied by information regarding optimum radiolographic technique for use with an amorphus silicon flat panel detector. The purpose of our study was to compared imaging characteristics and image quality of an amorphus silicon flat panel detectors for digital chest radiography. All examinations were performed by using an amorphus silicon flat panel detector. Chest radiographs of an chest phantom were obtained with peak kilovoltage values of 60$\sim$150 kVp. Published data ell the effect of x-ray beam energy on imaging characteristics and image qualify when using an amorphus silicon flat panel detector. It is important that radiographers are aware of optimum kVp selection for an amorphus silicon flat panel detector system, particularly for the commonly performed chest examination.

  • PDF

Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구 (A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index)

  • 김재인;이양섭;장동수;정민철;배승호;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제13권3호
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF

비정질 셀레늄을 이용한 평판 Digital X선 검출기 개발 (Development of flat panel digital x-ray detectorusing a-Se)

  • 박지군;최장용;강상식;차병열;장기원;최준영;남상희
    • 대한디지털의료영상학회논문지
    • /
    • 제6권1호
    • /
    • pp.24-30
    • /
    • 2003
  • 평판 digital x-선 검출기는 차세대 x-ray system으로 최근 연구와 개발이 활발하게 진행되고 있는 system이다. 본 연구는 환자의 피폭 및 작업 종사자의 피폭을 최소화 할 수 있고 의료장비의 디지털화에 발맞추어 PACS 등에 사용 가능한 a-Se을 이용한 직접방식의 digital x-선 검출기 구현에 관한 것이다. Prototype digital x-선 검출기는 TFT층과 a-Se층으로 이루어져 있다. Digital x-선 검출기센서 증착과 정의 최적화 수행 결과를 참고문헌1)-4)과 비교했을 때 매우 유사함을 확인하였다. 제작된 검출기의 pixel pitch는 $139{\mu}m$였고, fill factor는 86%, 전체 검출기의 검출면적은 14"${\times}$8.5"였다. Digital 영상의 해상력을 고려하기 위해 손과 test 패턴영상을 얻었고, 58%, 3.0lp/mm의 높은 MTF를 얻을 수가 있었다. 이러한 결과로 a-Se 기반의 Digital X선 검출기가 구현되었으며 본 연구결과를 토대로 향후 digital X선 검출기 개발기술의 발전과 성능향상을 가져올 것으로 기대된다.

  • PDF

교통신호의 자동최적점제어를 위한 마이크로파 FM-CW 검지계통에 관한 연구 (A Study on Microwave-FM-CW Detection System for the Sutomatic Optimal Point Traffic Control)

  • 양흥석;김호윤
    • 전기의세계
    • /
    • 제22권1호
    • /
    • pp.35-41
    • /
    • 1973
  • An automatic point traffic control method is recommended for more idealistic traffic flow over coarse road netowrks. The automatic control apparatus recommended, consists of a transceiver, amplifier, digital-to-analog converter, signal light controller for emergency and steady state, and digital counter as monitor. The transmitter sends a signal to the target vy means of Microwave-FM-CW and a diode detector picks up the echo signal. Thus the operation of the entire system will be carried out through an open loop state. Some factors necessary for an ideal detector system are rapid response, longevity and stability. An analytical method of the Doppler effect substitutes the conventional frequency deviation into the amplitude of detector output. The changing rate of amplitude is proportional to the voltage of the detector output. Some induced formula from Maxwell's radiation field theory ensures this new method, and, new method, and proves the fact with an experimental data presentation. Stability depends upon Klystron as an oscillator and a diode as a detector. the transceiver installation affects on the response and sensitivity of the system. In accordance with the detector output, several targets are easily classified by amplitudes on the scope. The traffic flow, i.e., target movement which is analyzed by the amplitude method, is shown through the scope and indicates it on the digital counter. The best efficiency for the amplitude analysis can be attained through use of an antenna having the highest sensitivity.

  • PDF