• Title/Summary/Keyword: digital dentistry

Search Result 853, Processing Time 0.02 seconds

Skin entrance dose for digital and film radiography in Korean dental schools

  • Cho Eun-Sang;Choi Kun-Ho;Kim Min-Gyu;Lim Hoi-Jeong;Yoon Suk-Ja;Kang Byung-Cheol
    • Imaging Science in Dentistry
    • /
    • v.35 no.4
    • /
    • pp.203-205
    • /
    • 2005
  • Purpose: This study was aimed to compare skin entrance dose of digital radiography with that of film radiography and to show the dose reduction achievement with digital systems at 11 dental schools in Korea. Materials and Methods: Forty six intraoral radiographic systems in 11 dental schools were included in this study. Digital sensors were used in 33 systems and film was used in 13 systems. Researchers and the volunteer visited 11 dental schools in Korea. Researchers asked the radiologic technician (s) at each school to set the exposure parameters and aiming the x-ray tube for the periapical view of the mandibular molar of the volunteer. The skin entrance doses were measured at the same exposure parameters and distance by the technician for each system with a dosimeter (Multi-O-Meter : Unfors instruments, Billdal, Sweden). Results: The median dose was $491.2{\mu}Gy$ for digital radiography and $1,205.0{\mu}Gy$ for film radiography. The skin entrance dose in digital radiography was significantly lower than that of film radiography (p<0.05). Conclusion: Fifty-nine percent skin entrance dose reduction with digital periapical radiography was achieved over the film radiography in Korean dental schools.

  • PDF

Creating protective appliances for preventing dental injury during endotracheal intubation using intraoral scanning and 3D printing: a technical note

  • Cho, Jin-Hyung;Park, Wonse;Park, Kyeong-Mee;Kim, Seo-Yul;Kim, Kee-Deog
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.17 no.1
    • /
    • pp.55-59
    • /
    • 2017
  • Digital dentistry has influenced many dental procedures, such as three-dimensional (3D) diagnosis and treatment planning, surgical splints, and prosthetic treatments. Patient-specific protective appliances (PSPAs) prevent dental injury during endotracheal intubation. However, the required laboratory work takes time, and there is the possibility of tooth extraction while obtaining the dental impression. In this technical report, we utilized new digital technology for creating PSPAs, using direct intraoral scanners and 3D printers for dental cast fabrication.

Evaluation of functional suitable digital complete denture system based on 3D printing technology

  • Deng, Kehui;Chen, Hu;Wang, Yong;Zhou, Yongsheng;Sun, Yuchun
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.6
    • /
    • pp.361-372
    • /
    • 2021
  • PURPOSE. To improve the clinical effects of complete denture use and simplify its clinical application, a digital complete denture restoration workflow (Functional Suitable Digital Complete Denture System, FSD) was proposed and preliminary clinical evaluation was done. MATERIALS AND METHODS. Forty edentulous patients were enrolled, of which half were treated by a prosthodontic chief physician, and the others were treated by a postgraduate student. Based on the primary impression and jaw relation obtained at the first visit, diagnostic denture was designed and printed to create a definitive impression, jaw relation, and esthetic confirmation at the second visit. A redesigned complete denture was printed as a mold to fabricate final denture that was delivered at the third visit. To evaluate accuracy of impression made by diagnostic denture, the final denture was used as a tray to make impression, and 3D comparison was used to analyze their difference. To evaluate the clinical effect of FSD, visual analogue scores (VAS) were determined by both dentists and patients. RESULTS. Two visits were reduced before denture delivery. The RMS values of 3D comparison between the impression made via diagnostic dentures and the final dentures were 0.165 ± 0.033 mm in the upper jaw and 0.139 ± 0.031 mm in the lower jaw. VAS ratings were between 8.5 and 9.6 in the chief physician group, while 7.7 and 9.5 in the student group; there was no statistical difference between the two groups. CONCLUSION. FSD can simplify the complete denture restoration process and reduce the number of visits. The accuracy of impressions made by diagnostic dentures was acceptable in clinic. The VASs of both dentists and patients were satisfied.

Comparison of digital and conventional radiography for the detection of proximal surface caries

  • Park, Si-Seung;Cho, Young-Gon
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.592.1-592
    • /
    • 2001
  • Conventional intraoral radiography continues to be the most widely used for the diagnosis of dental caries. But conventional intraoral film has several shortcomings, including processing error, increased radiation dose, etc. Recently, various digital radiographs substitude for conventional radiography to overcome these disadvantages. The digital radiographies are numerous advantages, including elimination of processing errors, lower radiation dose, image quality enhancements such as contrast and density modulation.(omitted)

  • PDF

The effects of image acquisition control of digital X-ray system on radiodensity quantification

  • Seong, Wook-Jin;Kim, Hyeon-Cheol;Jeong, Soocheol;Heo, Youngcheul;Song, Woo-Bin;Ahmad, Mansur
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.3
    • /
    • pp.146-153
    • /
    • 2013
  • Objectives: Aluminum step wedge (ASW) equivalent radiodensity (eRD) has been used to quantify restorative material's radiodensity. The aim of this study was to evaluate the effects of image acquisition control (IAC) of a digital X-ray system on the radiodensity quantification under different exposure time settings. Materials and Methods: Three 1-mm thick restorative material samples with various opacities were prepared. Samples were radiographed alongside an ASW using one of three digital radiographic modes (linear mapping (L), nonlinear mapping (N), and nonlinear mapping and automatic exposure control activated (E)) under 3 exposure time settings (underexposure, normal-exposure, and overexposure). The ASW eRD of restorative materials, attenuation coefficients and contrasts of ASW, and the correlation coefficient of linear relationship between logarithms of gray-scale value and thicknesses of ASW were compared under 9 conditions. Results: The ASW eRD measurements of restorative materials by three digital radiographic modes were statistically different (p = 0.049) but clinically similar. The relationship between logarithms of background corrected grey scale value and thickness of ASW was highly linear but attenuation coefficients and contrasts varied significantly among 3 radiographic modes. Varying exposure times did not affect ASW eRD significantly. Conclusions: Even though different digital radiographic modes induced large variation on attenuation of coefficient and contrast of ASW, E mode improved diagnostic quality of the image significantly under the underexposure condition by improving contrasts, while maintaining ASW eRDs of restorative materials similar. Under the condition of this study, underexposure time may be acceptable clinically with digital X-ray system using automatic gain control that reduces radiation exposure for patient.

Suitable scanning procedures for various prosthodontic treatments and the utilization of intraoral scanner (임상가를 위한 특집 3 - 여러 보철 치료 술식에 따른 바른 스캐닝 과정과 구강스캐너의 활용)

  • Park, Ji-Manm;Park, Eun-Jin;Heo, Seong-Joo
    • The Journal of the Korean dental association
    • /
    • v.52 no.6
    • /
    • pp.354-362
    • /
    • 2014
  • With the development of digital dentistry, various intra-oral scanners which acquire intraoral image without conventional impression taking and stone pouring steps have been introduced. Fixed dental prostheses such as inlay, onlay, crown, and bridge fabricated by CAD/CAM technique combined with digital impressions is getting popular due to the recent rapid progress of digital impression taking system. In comparison with traditional prosthetic procedure, the advantages of intraoral image acquiring and CAD/CAM technique are as follows; the omission of conventional impression materials, reduced workflow step, and increased efficiency by online communication with clinic and laboratory. This review article covers some opinions about the suitable scanning procedures for the various prosthodontic treatments and the utilization of digital intraoral scanner and CAD/CAM system.

Assessment of apical root resorption using digital subtraction radiography (디지털공제방사선촬영술을 이용한 치근단 흡수의 평가)

  • Heo Min-Suk;Lee Sam-Sun;Lee Kyung-Hee;Choi Hang-Moon;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.31 no.1
    • /
    • pp.51-55
    • /
    • 2001
  • Purpose : This study was performed to compare the diagnostic ability of conventional intraoral radiographs with that of digital subtraction image and to assess the quantifying ability of digital subtraction image for simulated apical root resorption Materials and Methods : Conventional intraoral radiographs and digital images of ten sound maxillary central incisors and those with simulated apical root resorption were taken with varying horizontal and vertical angulations of the x-ray beam. The diagnostic accuracy to detect the lesion was evaluated on conventional intraoral radiographs and digital subtraction images by ROC analysis. The amount of simulated apical root resorption was also estimated on the reconstruction images by Emago/sup (R)/ and compared with actual amount of tooth loss using paired t-test. Results: The diagnostic accuracy of conventional intraoral radiographs to detect the apical root resorption was low (ROC area = 0.6446), and the sensitivity and the specificity of digital subtraction images were 100%, respectively. The calculated amounts of apical root resorption showed no statistically significant difference with the actual amounts of the lesion (p>0.05). Conclusion: Digital subtraction radiography is powerful tool to detect the small apical root resorption, and quantitative analysis of small amounts of the lesion can be evaluated by digital subtraction radiography.

  • PDF

Occlusion and articulation in digital dentistry: A review (디지털 치의학 시대의 교합)

  • Lee, Jae-Hyun
    • The Journal of the Korean dental association
    • /
    • v.58 no.8
    • /
    • pp.505-512
    • /
    • 2020
  • With the fourth industrial revolution, digitization is accelerating in all healthcare areas. In the field of dentistry, active discussions on digital dental technologies are ongoing, with increasing interest from clinicians daily. Thus far, accuracy and efficiency have primarily been emphasized in digital dentistry, and interest in occlusion has been relatively low. This is because digital dentistry has been predominantly used to restore small numbers of teeth rather than extensive prosthetic reconstruction. However, in the future, most dental treatments will undergo a digital transformation that will require the application of digital technology to more extensive prosthetic rehabilitation, for which discussion of occlusion is essential. In extensive prosthetic reconstruction, occlusion and articulation involve determining the position of the dental arch in relation to the reference plane of the skull or the long axis of the face and the position of the transverse horizontal axis. It also includes determining an occlusal surface with a shape that allows the mandible to move in an eccentric path and masticate most efficiently without any occlusal interference. To better understand how digitization will impact dentistry, this review article summarizes and discusses occlusion and articulation using digital dental technologies. This discussion is divided into several aspects, including facial scan, virtual articulation, augmented reality, and virtual reality.

  • PDF

Biometry of width between labial transitional line angles in anterior teeth: an observational study

  • Wen, Chao;Ye, Hongqiang;Chen, Hu;Zhou, Yongsheng;Huang, Mingming;Sun, Yuchun
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • PURPOSE. The maximum width between the mesial and distal labial transitional line angles, described as "esthetic width" herein, could significantly influence the visual perception of the teeth and smile. This study aimed to conduct biometric research on esthetic width and to explore whether regular distribution exists in the esthetic width of human teeth. MATERIALS AND METHODS. A total of 4,264 maxillary and mandibular anterior teeth were measured using the Geomagic studio software program. The proportions of maxillary to mandibular homonymous teeth and proportions between the adjacent teeth were calculated. Bilateral symmetry and the correlation between the esthetic and mesiodistal widths were both accounted for during the measurement procedures. RESULTS. The mean esthetic widths were 6.773 ± 0.518 mm and 4.329 ± 0.331 mm for maxillary and mandibular central incisors, respectively, 5.451 ± 0.487 mm and 5.008 ± 0.351 mm for maxillary and mandibular lateral incisors, respectively, and 3.340 ± 0.353 mm and 5.958 ± 0.415 mm for maxillary and mandibular canines, respectively. Except for the mandibular canines, no significant difference in esthetic width was found among homonymous teeth from the same jaw. A high linear correlation was found between the esthetic and mesiodistal widths of the same tooth, except for the maxillary canines. Esthetic width proportions among different tooth categories showed some regular patterns, which were similar to those of the mesiodistal width. CONCLUSION. Esthetic width is regularly distributed among the teeth in the Chinese population. This could provide an important reference for anterior dental restorations and dimension recovery in esthetic reconstruction of anterior teeth.

Conventional and digital impressions for complete-arch implant-supported fixed prostheses: time, implant quantity effect and patient satisfaction

  • Pereira, Ana Larisse Carneiro;Medeiros, Vitoria Ramos;Campos, Maria de Fatima Trindade Pinto;Medeiros, Annie Karoline Bezerra de;Yilmaz, Burak;Carreiro, Adriana da Fonte Porto
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.4
    • /
    • pp.212-222
    • /
    • 2022
  • PURPOSE. To evaluate and compare the effect of impression type (conventional vs digital) and the number of implants on the time from the impressions to the generation of working casts of mandibular implant-supported fixed completearch frameworks, as well as on patient satisfaction. MATERIALS AND METHODS. 17 participants, 3 or 4 implants, received 2 types of digital impression methods (DI) and conventional (CI). In DI, two techniques were performed: scanning with the scan bodies (SC) and scanning with a device attached to the scan bodies (SD) (BR 10 2019 026265 6). In CI, the making of a solid index (SI) and open-tray impression (OT) were used. The outcomes were used to evaluate the time and the participant satisfaction with conventional and digital impressions. The time was evaluated through the timing of the time obtained in the workflow in the conventional and digital impression. The effect of the number of implants on time was also assessed. Satisfaction was assessed through a questionnaire based on seven. The Wilcoxon test used to identify the statistical difference between the groups in terms of time. The Mann-Whitney test was used to analyze the relationship between the time and the number of implants. Fisher's test was used to assess the patient satisfaction (P<.05). RESULTS. The time with DI was shorter than with CI (DI, $\tilde{x}=02:58$; CI, $\tilde{x}=31:48$) (P<.0001). The arches rehabilitated with 3 implants required shorter digital impression time (3: $\tilde{x}=05:36$; 4: $\tilde{x}=09:16$) (P<.0001). Regarding satisfaction, the DI was more comfortable and pain-free than the CI (P<.005). CONCLUSION. Digital impressions required shorter chair time and had higher patient acceptance than conventional impressions.