• Title/Summary/Keyword: digital $(k_{0},\

Search Result 3,232, Processing Time 0.029 seconds

Analysis of Digital Literacy Level of Reserve Officers' Training Corps in K-University (K-대학교 학군사관 후보생의 디지털 리터러시 수준분석)

  • Choi, Chul-Jae;Kang, Dong-Soo;Choi, Jin-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.113-118
    • /
    • 2018
  • In this research, we conducted a questionnaire using the existing developed digital literacy checklist for analyzing the digital literacy level of Reserve Officers' Training Corps in K-University. In order to verify the validity and reliability of the measurement results collected on the basis of the response results, factor analysis of the question was carried out using the statistical analysis program SPSS 21.0, for each research group, the ability level by each factor was analyzed. Based on the results of analysis using frequency analysis, T-test and One-way ANOVA, we suggested measures to improve digital literacy level of school district officer candidates.

IMAGE FUSION ACCURACY FOR THE INTEGRATION OF DIGITAL DENTAL MODEL AND 3D CT IMAGES BY THE POINT-BASED SURFACE BEST FIT ALGORITHM (Point-based surface best fit 알고리즘을 이용한 디지털 치아 모형과 3차원 CT 영상의 중첩 정확도)

  • Kim, Bong-Chul;Lee, Chae-Eun;Park, Won-Se;Kang, Jeong-Wan;Yi, Choong-Kook;Lee, Sang-Hwy
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.5
    • /
    • pp.555-561
    • /
    • 2008
  • Purpose: The goal of this study was to develop a technique for creating a computerized composite maxillofacial-dental model, based on point-based surface best fit algorithm and to test its accuracy. The computerized composite maxillofacial-dental model was made by the three dimensional combination of a 3-dimensional (3D) computed tomography (CT) bone model with digital dental model. Materials and Methods: This integration procedure mainly consists of following steps : 1) a reconstruction of a virtual skull and digital dental model from CT and laser scanned dental model ; 2) an incorporation of dental model into virtual maxillofacial-dental model by point-based surface best fit algorithm; 3) an assessment of the accuracy of incorporation. To test this system, CTs and dental models from 3 volunteers with cranio-maxillofacial deformities were obtained. And the registration accuracy was determined by the root mean squared distance between the corresponding reference points in a set of 2 images. Results and Conclusions: Fusion error for the maxillofacial 3D CT model with the digital dental model ranged between 0.1 and 0.3 mm with mean of 0.2 mm. The range of errors were similar to those reported elsewhere with the fiducial markers. So this study confirmed the feasibility and accuracy of combining digital dental model and 3D CT maxillofacial model. And this technique seemed to be easier for us that its clinical applicability can good in the field of digital cranio-maxillofacial surgery.

Significance and Application of Digital Breast Tomosynthesis for the BI-RADS Classification of Breast Cancer

  • Cai, Si-Qing;Yan, Jian-Xiang;Chen, Qing-Shi;Huang, Mei-Ling;Cai, Dong-Lu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.4109-4114
    • /
    • 2015
  • Background: Full-field digital mammography (FFDM) with dense breasts has a high rate of missed diagnosis, and digital breast tomosynthesis (DBT) could reduce organization overlapping and provide more reliable images for BI-RADS classification. This study aims to explore application of COMBO (FFDM+DBT) for effect and significance of BI-RADS classification of breast cancer. Materials and Methods: In this study, we selected 832 patients who had been treated from May 2013 to November 2013. Classify FFDM and COMBO examination according to BI-RADS separately and compare the differences for glands in the image of the same patient in judgment, mass characteristics display and indirect signs. Employ Paired Wilcoxon rank sum test was used in 79 breast cancer patients to find differences between two examine methods. Results: The results indicated that COMBO pattern is able to observe more details in distribution of glands when estimating content. Paired Wilcoxon rank sum test showed that overall classification level of COMBO is higher significantly compared to FFDM to BI-RADS diagnosis and classification of breast (P<0.05). The area under FFDM ROC curve is 0.805, while that is 0.941 in COMBO pattern. COMBO shows relation of mass with the surrounding tissues, the calcification in the mass, and multiple foci clearly in breast cancer tissues. The optimal sensitivity of cut-off value in COMBO pattern is 82.9%, which is higher than that in FFDM (60%). They share the same specificity which is both 93.2%. Conclusions: Digital Breast Tomosynthesis (DBT) could be used for the BI-RADS classification in breast cancer in clinical.

Study on Factors Affecting Turnover Intention of Digital evidence analyst : Focus on Job stress, Job satisfaction, Organizational commitment (디지털증거분석관의 이직 의도에 영향을 주는 요인에 관한 연구 - 직무스트레스, 직무만족, 조직몰입을 중심으로)

  • Kim, Kyu-Rim;Kwak, Na-Yeon;Lee, Choong C.
    • Journal of Digital Convergence
    • /
    • v.16 no.8
    • /
    • pp.1-10
    • /
    • 2018
  • With advances in digital technologies digital crimes also rapidly have been increased. For this reason, the digital forensics has an important role in investigating digital crimes. In particular digital evidence analysts have been responsible for more workloads as much increased as it reflects an importance of their task. However previous researches have more focused on technology, not much on their work circumstance and behaviors. This study is to draw out factors affecting job stress and its effects on their turnover rate as it considers Job satisfaction, organization commitment. In this study, survey have been conducted targeting 124 personnel in National Police Agency and then the collected data were analyzed by using Smart PLS 3.0. This study have proved that causal relationship between job stress, satisfaction, commitment and job turnover respectively which is borrowed from organizational concepts. There will be theoretical and practical contribution to improve work circumstance and secure digital forensic talents as well.

Digital Dimmer for AC LED (AC LED 용 Digital Dimmer)

  • Kim, Sang-Il;Park, In-Gi;Ha, Seok-Jin;Kim, Jong-Hyun;Yoo, Dong-Wook;Kim, In-Dong
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.280-282
    • /
    • 2009
  • 본 논문은 AC LED에 적합한 Digital Dimmer에 관한 연구이다. PWM 방식을 이용하여 조광 범위를 0~100% 되게 하였을 뿐만 아니라 AC LED를 상용 전원에 연결하여 사용 시 발생하는 플리커 문제를 플리커 개선 알고리즘을 추가하여 해결하였다.

  • PDF

A Convergence Study on Evaluation of Usefulness of Copper Additional Filter in the Digital Radiography System (디지털 방사선장치에서 구리 부가필터의 유용성 평가에 관한 융복합 연구)

  • Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.13 no.9
    • /
    • pp.351-359
    • /
    • 2015
  • This convergence study analyzed the effectiveness of digital radiography system of copper(Cu) filter in the added filtration for the removal of lower energy radiation through dose and image evaluation. We were analyzed from April to June 2015 result of the examination. Cu filter was applied to each non, 0.1, 0.2, 0.3 mm according to change of kV and mAs and doses were evaluated. Image quality was evaluated by PSNR, MAE, MSE, CNR, SNR and qualitative analysis was performed by seven items for resolution and contrast from chest x-ray criteria of national cancer checkup. The absorbed doses with Cu were lowered by 16-88 % than non-filter but the gaps decreased as kV increased. PSNR were over 30 dB and all significant and CNR and SNR were superior with non-filter but in the qualitative analysis, there were different statistical significant according to each item. The score of 0.1 mm filter was high at pulmonary blood vessel observation and in the 0.3 mm Cu, there were no statistical signigicant except high density and full of air portion. Cu filter can improve image quality with lower radiation dose using better radiation quality and correction power at digital radiography system.

A 1.8 V 40-MS/sec 10-bit 0.18-㎛ CMOS Pipelined ADC using a Bootstrapped Switch with Constant Resistance

  • Eo, Ji-Hun;Kim, Sang-Hun;Kim, Mun-Gyu;Jang, Young-Chan
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.1
    • /
    • pp.85-90
    • /
    • 2012
  • A 40-MS/sec 10-bit pipelined analog to digital converter (ADC) with a 1.2 Vpp differential input signal is proposed. The implemented pipelined ADC consists of eight stages of 1.5 bit/stage, one stage of 2 bit/stage, a digital error correction block, band-gap reference circuit & reference driver, and clock generator. The 1.5 bit/stage consists of a sub-ADC, digital to analog (DAC), and gain stage, and the 2.0 bit/stage consists of only a 2-bit sub-ADC. A bootstrapped switch with a constant resistance is proposed to improve the linearity of the input switch. It reduces the maximum VGS variation of the conventional bootstrapped switch by 67%. The proposed bootstrapped switch is used in the first 1.5 bit/stage instead of a sample-hold amplifier (SHA). This results in the reduction of the hardware and power consumption. It also increases the input bandwidth and dynamic performance. A reference voltage for the ADC is driven by using an on-chip reference driver without an external reference. A digital error correction with a redundancy is also used to compensate for analog noise such as an input offset voltage of a comparator and a gain error of a gain stage. The proposed pipelined ADC is implemented by using a 0.18-${\mu}m$ 1- poly 5-metal CMOS process with a 1.8 V supply. The total area including a power decoupling capacitor and the power consumption are 0.95 $mm^2$ and 51.5 mW, respectively. The signal-to-noise and distortion ratio (SNDR) is 56.15 dB at the Nyquist frequency, resulting in an effective number of bits (ENOB) of 9.03 bits.

Comparison of Sphygmomanometer, Fully Automatic Electronic Blood Pressure Meters with Standard Digital Blood Pressure Monitor : Pilot Study (표준전자식 혈압계와 수은혈압계, 전자혈압계의 비교 선행연구)

  • Yahng, J.S.;Lim, H.K.;Cho, D.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.155-162
    • /
    • 2012
  • Devices to measure the blood pressure of patients are being used without any calibration in a hospital. It is an important to show consistent values when any medical devices measure the same patients regardless they are sphygmomanometer or fully automatic electronic blood pressure meter. We compared sphygmomanometer and fully automatic electronic blood pressure meters with standard digital blood pressure monitor (SDBPM) to evaluate the consistency of the small healthy subjects. We measured the blood pressure from six healthy subjects (three of 20~40 years and three of 40~60 years old). Two sphygmomanometer and two fully automatic electronic blood pressure meters were used and compared with the SDBPM. Blood pressures measured from right and left arms each and were compared. All six healthy subjects showed normal blood pressure values. In general, left blood pressure values showed higher values than right side. Comparing SDBPM, with the other monitors, the systolic pressure showed ${\pm}$ 34.8% difference and ${\pm}$ 33.3% for the diastolic pressure. Correlation between SDBPM and Sphygmomanometer was 0.59~0.71, and 0.50~0.70 for fully automated digital BP monitors. It fell in grade-D when we apply the BHS(British hypertension society). AAMI(American association for the advancement of medical instrumentation) also showed unsatisfactory results for the mean value (${\leq}$ 5 mmHg) and standard deviation (${\leq}$ 8 mmHg). We tested sphygmomanometer and fully automatic electronic blood pressure meters and compared with a standard digital blood pressure monitor. All devices showed inconsistent blood pressures. A reliable calibration system is highly needed for all devices in all hospitals.

Evaluation of the Filling Sodium States Inside the Fuel rod of Sodium-Cooled Fast Reactor by Optimized Spatial Resolution in Medical Digital Radiographic Images (의료용 디지털방사선영상의 공간분해능 최적화에 의한 소듐냉각고속로 연료봉 내부의 소듐 충전상태 평가)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.117-124
    • /
    • 2016
  • The purpose of this study was tried to evaluate the filling sodium states inside the fuel rod of sodium-cooled fast reactor by digital medical X-ray. We used the diagnostic X-ray generators in digital radiography (DR). This study have found the optimal conditions by changing the effective focal spot size of X-ray tube and post-processing of the DR method with a tungsten edge plate in order to ensure excellent sharpness At this time, the sharpness and resolution were evaluated using the MTF (modulation transfer function). As a result, this study obtained a spatial resolution of 3.871 lp/mm (0.1 MTF), 3.290 lp/mm (0.5 MTF) when implemented the contrast strengthen post-processing in small focal spot. In this research, the result is able to evaluate the level of sodium inside the fuel rod by using the diagnostic X-ray generators in medical digital radiographic images.

A Design of Vernier Coarse-Fine Time-to-Digital Converter using Single Time Amplifier

  • Lee, Jongsuk;Moon, Yong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.4
    • /
    • pp.411-417
    • /
    • 2012
  • A Coarse-Fine Time-to-Digital Converter (TDC) using the single time amplifier is proposed. A vernier delay line is used to overcome process dependency and the 2-stage time amplifier is designed to have high resolution by increasing the gain of the time amplifier. Single time amplifier architecture reduces the silicon area of the TDC and alleviates mismatch effect between time amplifiers. The proposed TDC is implemented in $0.18{\mu}m$ CMOS process with the supply voltage of 1.8 V. The measured results show that the resolution of the TDC is 0.73 ps with 10-bit digital output, although highend process is not applied. The single time amplifier architecture reduces 13% of chip area compared to previous work. By reducing the supply voltage, the linearity of the TDC is enhanced and the resolution is decreased to 1.45 ps.