• Title/Summary/Keyword: different line widths

Search Result 47, Processing Time 0.028 seconds

A development of the simple camera calibration system using the grid type frame with different line widths (다른 선폭들로 구성된 격자형 교정판을 이용한 간단한 카메라 교정 시스템의 개발)

  • 정준익;최성구;노도환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.371-374
    • /
    • 1997
  • Recently, the development of computer achieves a system which is similar to the mechanics of human visual system. The 3-dimensional measurement using monocular vision system must be achieved a camera calibration. So far, the camera calibration technique required reference target in a scene. But, these methods are inefficient because they have many calculation procedures and difficulties in analysis. Therefore, this paper proposes a native method that without reference target in a scene. We use the grid type frame with different line widths. This method uses vanishing point concept that possess a rotation parameter of the camera and perspective ration that perspect each line widths into a image. We confirmed accuracy of calibration parameter estimation through experiment on the algorithm with a grid paper with different line widths.

  • PDF

A Study on the Camera Calibration Algorithm using the Grid Type Frame with Different Line Widths (다른 선폭들로 구성된 격자형 교정판을 이용한 카메라 교정 알고리즘에 관한 연구)

  • Jeong, Jun-Ik;Han, Young-Bae;Rho, Do-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2333-2335
    • /
    • 1998
  • Recently, the development of computer achieves a system which is similar to the mechanics of human visual system. The 3D measurement using monocular vision system must be achieved a camera calibration. So far, the camera calibration technique required reference target in a scene. But, these methods are inefficient because they have many calculation procedures and difficulties in analysis. Therefore, this paper proposes a native method that without reference target in a scene. We use the grid type frame with different line widths. This method uses vanishing point concept that possess a rotation parameter of the camera and perspective ration that perfect each line widths into a image. We confirmed accuracy of calibration parameter estimation through experiment on the algorithm with a grid paper with different line widths.

  • PDF

A Study for Princess Line according to Body Type II - Focused on Body Type of H & Y - (체형에 따른 프린세스 라인 연구 II - H 체형과 Y 체형을 중심으로 -)

  • 김숙정;서미아
    • The Research Journal of the Costume Culture
    • /
    • v.9 no.6
    • /
    • pp.893-907
    • /
    • 2001
  • The main purpose is to study the effects of princess lines on different body types and to disguise any imperfection by using diverse princess lines. We separated testers body shapes into specific body types, H, Y by applying both the direct and the indirect measurements. These designs were evaluated by using the point ranking system method, and then average scores were obtained from these evaluations. Following are the results of the study: 1 These are the resulting illusion effects when the shoulder width of the Princess line was fixed. When the Princess line originated from 1/3 point of the armhole, body types Y appeared to show narrow waist width. A-line silhouette appeared to display the narrowest shoulder width. When the Princess line originated from 2/3 point of the armhole, body types H and Y appeared to exhibit narrowest waist widths, and the A-line silhouette once again displayed the narrowest shoulder width. When the Princess line originated from 1/2 point of the armhole, body type H appeared to exhibit narrow width; and H-line silhouette displayed the narrowest shoulder width 2. When the Princess lines waist w'4th was fixed in order to study illusion effects of waist widths. In this experiment, locations of Princess lines and widths of the skirt were varied. When the waist width was fixed at 6.5 cm, For the H body type, the Princess line location of 1/3 point of the armhole in H-line silhouette design exhibited the narrowest waist width. For the Y body type in A-line silhouette design, the Princess line locations of 1/3 and 1/2 points of the armhole exhibited the narrowest waist width because it displayed the hourglass effect. When the waist width was fixed at 10 cm, H body type did not exhibit any significant differences between designs. For Y body type, A-line silhouette design with the Princess line origination point at 1/3 down the armhole exhibited the narrowest waist width. 3. The illusion effects of the hip were studied by fixating the width of the skirt and varying the locations of Princess line and waist widths. In H-line skirt silhouette designs, all two body types exhibited narrow hips when the Princess line origination points were at 1/3 and 1/2 way down the armhole. For A-line skirt silhouette, H body type exhibited narrow hips when narrow waist design with the Princess line originating from 1/2 point in the shoulder was shown. Y body type exhibited narrow hips when narrow waist design with the Princess line originating from 1/3 point of the armhole and 2/3 point of the shoulder. 4. With both waist and skirt widths fixed, all two body types exhibited taller and slender postures when the Princess line originated from the shoulder compare to the armhole.

  • PDF

A Study On the Safe Width and Alignment of the Navigational Channel (선박의 안전을 위한 최적 항로배치 및 항로폭 결정에 관한 연구)

  • 김환수
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.1 no.1
    • /
    • pp.9-25
    • /
    • 1995
  • Although the studies carried out in recent years have provied much new information about channel widths and alignment, they are not consistent in their results. In addition, as a result of variations in local condition and type of traffic accommodated, the dimensions of the channel widths vary over a wide range. Therefore, the recommendation made by the maritime engineering organizations over the world, do not offer detailed and decisive optimal design criteria and are all different. It, therefore, was attempted in this paper to draw a decisive guideline on the optimal widths and alignment of the navigational channels, which can be utilized by the port designers at the stage of the planning. The guideline was drawn through the comparison and analysis of the existing guidelines of the U.S.A, Japan and PIANC and simulation experiment. The simulation experiment was carried out using the "Off Line Port and Waterway Design Simulator" to find the optimal dimensions of the widths of the navigational channels. 90 different simulation runs were conducted at the 3 different secenario channels. New guidelines, the result of the study, is expected to be used usefully by the Korean port designers when designing the rapodly developing ports in Korea. in Korea.

  • PDF

Camera calibration parameters estimation using perspective variation ratio of grid type line widths (격자형 선폭들의 투영변화비를 이용한 카메라 교정 파라메터 추정)

  • Jeong, Jun-Ik;Choi, Seong-Gu;Rho, Do-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.30-32
    • /
    • 2004
  • With 3-D vision measuring, camera calibration is necessary to calculate parameters accurately. Camera calibration was developed widely in two categories. The first establishes reference points in space, and the second uses a grid type frame and statistical method. But, the former has difficulty to setup reference points and the latter has low accuracy. In this paper we present an algorithm for camera calibration using perspective ratio of the grid type frame with different line widths. It can easily estimate camera calibration parameters such as lens distortion, focal length, scale factor, pose, orientations, and distance. The advantage of this algorithm is that it can estimate the distance of the object. Also, the proposed camera calibration method is possible estimate distance in dynamic environment such as autonomous navigation. To validate proposed method, we set up the experiments with a frame on rotator at a distance of 1, 2, 3, 4[m] from camera and rotate the frame from -60 to 60 degrees. Both computer simulation and real data have been used to test the proposed method and very good results have been obtained. We have investigated the distance error affected by scale factor or different line widths and experimentally found an average scale factor that includes the least distance error with each image. The average scale factor tends to fluctuate with small variation and makes distance error decrease. Compared with classical methods that use stereo camera or two or three orthogonal planes, the proposed method is easy to use and flexible. It advances camera calibration one more step from static environments to real world such as autonomous land vehicle use.

  • PDF

COMPARISON OF LOS DOPPLER VELOCITIES AND NON-THERMAL LINE WIDTHS IN THE OFF-LIMB SOLAR CORONA MEASURED SIMULTANEOUSLY BY COMP AND HINODE/EIS

  • Lee, Jae-Ok;Lee, Kyoung-Sun;Seough, Jungjoon;Cho, Kyung-Suk
    • Journal of The Korean Astronomical Society
    • /
    • v.54 no.2
    • /
    • pp.49-60
    • /
    • 2021
  • Observations of line of sight (LOS) Doppler velocity and non-thermal line width in the off-limb solar corona are often used for investigating the Alfvén wave signatures in the corona. In this study, we compare LOS Doppler velocities and non-thermal line widths obtained simultaneously from two different instruments, Coronal Multichannel Polarimeter (CoMP) and Hinode/EUV Imaging Spectrometer (EIS), on various off-limb coronal regions: flaring and quiescent active regions, equatorial quiet region, and polar prominence and plume regions observed in 2012-2014. CoMP provides the polarization at the Fe xiii 10747 Å coronal forbidden lines which allows their spectral line intensity, LOS Doppler velocity, and line width to be measured with a low spectral resolution of 1.2 Å in 2-D off limb corona between 1.05 and 1.40 RSun, while Hinode/EIS gives us the EUV spectral information with a high spectral resolution (0.025 Å) in a limited field of view raster scan. In order to compare them, we make pseudo raster scan CoMP maps using information of each EIS scan slit time and position. We compare the CoMP and EIS spectroscopic maps by visual inspection, and examine their pixel to pixel correlations and percentages of pixel numbers satisfying the condition that the differences between CoMP and EIS spectroscopic quantities are within the EIS measurement accuracy: ±3 km s-1 for LOS Doppler velocity and ±9 km s-1 for non-thermal width. The main results are summarized as follows. By comparing CoMP and EIS Doppler velocity distributions, we find that they are consistent with each other overall in the active regions and equatorial quiet region (0.25 ≤ CC ≤ 0.7), while they are partially similar to each other in the overlying loops of prominences and near the bottom of the polar plume (0.02 ≤ CC ≤ 0.18). CoMP Doppler velocities are consistent with the EIS ones within the EIS measurement accuracy in most regions (≥ 87% of pixels) except for the polar region (45% of pixels). We find that CoMP and EIS non-thermal width distributions are similar overall in the active regions (0.06 ≤ CC ≤ 0.61), while they seem to be different in the others (-0.1 ≤ CC ≤ 0.00). CoMP non-thermal widths are similar to EIS ones within the EIS measurement accuracy in a quiescent active region (79% of pixels), while they do not match in the other regions (≤ 61% of pixels); the CoMP observations tend to underestimate the widths by about 20% to 40% compared to the EIS ones. Our results demonstrate that CoMP observations can provide reliable 2-D LOS Doppler velocity distributions on active regions and might provide their non-thermal width distributions.

The Camera Calibration Parameters Estimation using The Projection Variations of Line Widths (선폭들의 투영변화율을 이용한 카메라 교정 파라메터 추정)

  • Jeong, Jun-Ik;Moon, Sung-Young;Rho, Do-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2372-2374
    • /
    • 2003
  • With 3-D vision measuring, camera calibration is necessary to calculate parameters accurately. Camera calibration was developed widely in two categories. The first establishes reference points in space, and the second uses a grid type frame and statistical method. But, the former has difficulty to setup reference points and the latter has low accuracy. In this paper we present an algorithm for camera calibration using perspective ratio of the grid type frame with different line widths. It can easily estimate camera calibration parameters such as focal length, scale factor, pose, orientations, and distance. But, radial lens distortion is not modeled. The advantage of this algorithm is that it can estimate the distance of the object. Also, the proposed camera calibration method is possible estimate distance in dynamic environment such as autonomous navigation. To validate proposed method, we set up the experiments with a frame on rotator at a distance of 1,2,3,4[m] from camera and rotate the frame from -60 to 60 degrees. Both computer simulation and real data have been used to test the proposed method and very good results have been obtained. We have investigated the distance error affected by scale factor or different line widths and experimentally found an average scale factor that includes the least distance error with each image. It advances camera calibration one more step from static environments to real world such as autonomous land vehicle use.

  • PDF

Evaluation of the Nip Pressure Profile and Analysis of Heat Transfer in Soft Nip Calender (소프트닙 캘린더의 닙 압력 프로파일 평가와 닙 내 열전달 현상에 대한 해석)

  • 이사용;이학래;박선규
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.2
    • /
    • pp.26-34
    • /
    • 2000
  • Understanding the nip geometry and heat transfer phenomena of soft nip calenders, which has been used in the production of newsprint and coated papers for many years, is very important since improper setting of soft nip calendering conditions causes deterioration of paper quality and productivity. In this study theoretical analysis on nip pressure and heat transfer phenomena in the nip of soft nip calenders has been made. The variables examined were calendering pressure, surface temperature of the heating roll, nip residence time and ingoing sheet moisture, By measuring nip widths and maximum nip pressure with Prescale film at a normal temperature, accurate line load has been obtained. With this line load, nip pressures at different temperature and nip widths were calculated. Results showed that as temperature increased, nip widths increased and nip pressures decreased. Equations derived for the heat conduction phenomena in soft nip calender nip were derived based on the semi-infinite plate and finite difference method and were used for the analysis of heat transfer within the nip. Temperature profiles in z-direction of paper within the nip were obtained. Finite difference method allowed more accurate analysis of the heat transfer in the calender nip. In this study newsprint and coated paper were considered as a single plate and two-layer plate consisted of sheet and coating layers, respectively. Heat trans-fer to paper increased as heated roll surface temperature and nip residence time were increased.

  • PDF

A Study on the Camera Calibration Algorithm using Perspective Ratio of Difference Line Widths

  • Jeong, Jun-Ik;Song, Suck-Woo;Lee, Ho-Soon;Rho, Do-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.63.1-63
    • /
    • 2001
  • At 3-D vision measuring, the camera calibration is necessary to calculate parameters accurately. Camera calibration was developed widely in two categories. One is that establishes reference points in space, and the other is that uses the grid type frame and statistical method. But, the former has difficult to setup reference points and the latter has low accuracy. In this paper we present an algorithm for camera calibration using perspective ratio of the grid type frame with different line widths. The advantage of this algorithm is that it can estimate position, pose and distance between camera and object ...

  • PDF