• Title/Summary/Keyword: difference of air pressure

Search Result 551, Processing Time 0.034 seconds

Seasonal Variations of Direct Solar Irradiance with Ground and Air Atmospheric Data Fusion for Peninsular Type Coastal Area (지상 및 고도별 대기측정 자료 융합을 이용한 반도형 해안지역의 직달일사량 계절 변화 연구)

  • Choi, Ji Nyeong;Lee, Sanghee;Seong, Sehyun;Ahn, Ki-Beom;Kim, Sug-Whan;Kim, Jinho;Park, Sanghyun;Jang, Sukwon
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.3
    • /
    • pp.411-423
    • /
    • 2020
  • Localized solar irradiance is normally derived from atmospheric transmission influenced by atmospheric composition and conditions of the target area. Specially, for the area with complex coastal lines such as Taean gun, the accurate estimation of solar irradiance requires for in depth analysis of atmospheric transmission characteristics based on the localized vertical profiles of the key atmospheric parameters. Using MODTRAN (MODerate resolution atmospheric TRANsmission) 6, we report a computational study on clear day atmospheric transmission and direct solar irradiance estimation of Taean gun using the data collected from 3 ground stations and radiosonde measurement over 93 clear days in 2018. The MODTRAN estimated direct solar irradiance is compared with the measurement. The results show that the normalized residual mean (NRM) is 0.28 for the temperature based MODTRAN atmospheric model and 0.32 for the pressure based MODTRAN atmospheric model. These values are larger than 0.1~0.2 of the other study and we understand that such difference represents the local atmospheric characteristics of Taean gun. The results also show that NRM tends to increase noticeably in summer as the temperature increases. Such findings from this study can be very useful for estimation and prediction of the atmospheric condition of the local area with complex coastal lines.

Physicochemical quality characteristics of hot water extracts of processed ginseng based on different heat treatments (열처리 방법에 따른 가공 인삼 열수추출물의 이화학적 품질 특성)

  • Kang, Yoon-Han;Zhou, Rui;Kim, Hyo Jin;Kim, Ji Eun;Shin, Il Shik
    • Food Science and Preservation
    • /
    • v.25 no.1
    • /
    • pp.155-163
    • /
    • 2018
  • The present study was carried out to investigate the physicochemical properties of hot water extracts of red ginseng powder prepared by two-stage hot air drying method using steamed ginseng and steaming liquid for 2.5 h under high-temperature and high-pressure autoclave condition. The total polyphenols, total flavonoids, total sugar, acid polysaccharides and crude saponin in hot water extracts from red ginseng powder were analyzed and determined, and the flavor components of ginseng were measured using color difference meter and an electronic tongue. The total polyphenol, total flavonoid, total polysaccharide, and acid polysaccharide of the red ginseng hot water extract obtained by autoclaving (ARG) were 9.06 mg GAE/g, 3.38 mg NE/g, 35.22 g/100 g, and 10.90 g/100 g, respectively. The final contents of the total polyphenols, total flavonoids, crude saponin were higher than those determined using other red ginseng methods; the time required for steamed red ginseng production reduced. The total ginsenoside content of ginseng including Rb1 was 10.69 mg/g, which is the lowest ARG. The processing conditions affected the conversion to ginsenosides unique to red ginseng. Red ginseng and steaming liquid obtained from the autoclave are expected to be in need for non-food materials and products as well as foods by improving the flavor components through conversion of red ginseng components into low molecular weight.

Gas Permeation Properties of Polymeric Membranes for Biosensor Prepared from Poly(vinyl chloride) Derivatives (Poly(vinyl chloride) 유도체로부터 제조된 바이오센서용 고분자막의 기체 투과특성)

  • Lim, Chun-Won;Kim, Wan-Young;Lee, Youn-Sik;Yoon, Jeong-Won;Jeong, Yong-Seob
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.362-366
    • /
    • 1999
  • Membranes for biosensor were prepared from poly(vinyl chloride) (PVC)l derivatives using the solution casting method, and their gas permeabilities were studied. The polymer membranes dried slowly in air showed higher permeability coefficients than those dried in vacuum. The permeabilily coefficients of carboxylated poly(vinyl chloride) (CPVC) membranes for $O_2$ and $CO_2$ decreased as the pressure of the feed gas increased. The addition of dioctylphthalate (DOP) enhanced the permeation rates for $O_2$ and $CO_2$. For example, the permeability coefficients of CPVC membranes containing 30 wt. % DOP for $O_2$ and $CO_2$ at 100 psig were 2.03 and 0.96 Barrer, respectively, which were about 4~5 times higher than those of the membranes without DOP. Poly(vinyl chloride-co-vinyl acetate-co-vinyl alcohol) (Syn-PVCAcAl) obtained by hydrolysis of poly(vinyl chloride-co-vinyl acetate (PVCA) showed a higher permeability coefficient for $CO_2$ in the presence of DOP than that for commercial PVCAcAl, but did not show any significant difference in permeability for $O_2$.

  • PDF

A study on characteristics of combustion and exhaust emissions on bio-diesel fuel in marine diesel generator engine (Low load centering) (선박용 디젤발전기에서 바이오연료의 연소 및 배기배출물 특성에 관한 연구 (저부하 영역 중심으로))

  • Cho, Sang-Gon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.7
    • /
    • pp.716-721
    • /
    • 2015
  • As the severity of environmental pollution has increased, restrictions on air pollution have been strengthened. Stringent regulations have been imposed, not only on marine diesel engines but also on automotive and industrial power plants. Thus, biofuels have been directly applied in practical engines and used in training ships for basic research. Even though a high biofuel percentage cannot be used in a training ship engine for safety reasons, because this type of engine is larger than those used in institutional laboratories, the results will provide important basic information that will allow organizations to determine the status of a large output. Biodiesel fuel was studied to determine how it would affect the combustion characteristics and exhaust emissions of a marine diesel generator engine. The main results can be summarized as follows. Because the physical and chemical compositions of biofuels are similar to those of diesel fuel, it was found that their practical use was possible in a training ship. The specific fuel consumption and NOx increased, whereas a tendency was found for carbon monoxide and soot to decrease. In addition, no significant pressure change difference was found between the diesel fuel and biofuels.

Development and Animal Tests of Prototype Oxygen Concentrator (국산 산소 농축기의 개발 및 동물실험)

  • 변정욱;성숙환;이태수
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.643-649
    • /
    • 1998
  • Background: For the patient with chronic obstructive pulmonary disease requiring long-term oxygen therapy, oxygen concentrator machines are already widely available for use in home. In this study, we used mongrel dogs as test subjects to compare the functional efficiency and safety of the oxygen concentrator developed by our own research team with those of the imported FORLIFE(TM) machine made by AIRSEP Corp. Method and method: To test mechanical reliability, the concentrations of oxygen delivered were measured after 4 hours of continuous operation. Sixteen mongrel dogs were divided into two equal groups. Mongrel dogs in group A were given oxygen using the imported oxygen concentrator, and those in group B using the machine developed. 5 l/min of oxygen were given, after which vital signs were analyzed, arterial blood gases measured, and blood chemistry tests carried out. Results: After 4 hours of continuous operation, the imported model performed better, giving 98${\pm}$3% oxygen, compared to our model, which gave 91${\pm}$1%. In the animal experiments, oxygen concentrations were measured at the inlet of face mask 1, 2, 3, and 4 hours after continuous administration, and there was no statistically significant difference(repeated measures of analysis of variance p=0.70) between the values of 70.6${\pm}$2.5%, 67.1${\pm}$2.9%, 68.2${\pm}$2.6%, and 64.9${\pm}$3.9% that were measured from group A, and the values of 65.1${\pm}$4.8%, 65.2${\pm}$3.6%, 68.7${\pm}$4.3%, and 66.0${\pm}$5.0% measured from group B. Before oxygen administration, and at 1, 2, 3, and 4 hours after oxygen administration, arterial blood partial pressure of oxygen 87.2${\pm}$2.5 mmHg, 347.4${\pm}$29.3 mmHg, 353.4${\pm}$21.2 mmHg, 343.0${\pm}$28.8 mmHg, and 321.6${\pm}$24.4 mmHg, respectively, were read from group A, which were not statistically different (p=0.24) to the values of 102.5${\pm}$9.6 mmHg, 300.3${\pm}$17.1 mmHg, 321.6${\pm}$23.7 mmHg, 303.4${\pm}$27.4 mmHg, and 273.5${\pm}$25.9 mmHg read from group B. Nonetheless, the arterial blood partial pressure of oxygen values appear to be somewhat higher in dogs that were given oxygen using the imported oxygen concentrator. Conclusions: From these results the prototype oxygen concentrator developed appears to function relatively satisfactorily compared to the imported, established model, but may be criticized for the excessive noise generated and poor long-term endurance or consistency, which need improvement.

  • PDF

Carboxyhemoglobin Dissociation at the Various Partial Pressures of Oxygen -Comparison between Adult and Fetal Bloods- (산소분압(酸素分壓)에 따른 Carboxyhemoglobin의 해리양상(解離樣相) -성인혈(成人血)과 태아혈(胎兒血)의 비교(比較)-)

  • Park, Byung-Joo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.15 no.1
    • /
    • pp.145-151
    • /
    • 1982
  • Breslau's report on the two stillbirths induced by illuminating gas poisoning made many investigators explore the hazards. of carbon monoxide(CO) poisoning to pregnancy. The pregnant woman, her fetus, and the newborn infant have been identified to be particularly vulnerable to CO even in low concentration. Several factors, such as placental barrier, membrane resistance of maternal and fetal red blood cells etc., were considered to be related to the delayed elimination of CO from fetus. Slower elimination of CO from fetus than from mother was confirmed in several in vivo studies. But there are few studies which have confirmed the difference of carboxyhemoglobin (HbCO) dissociation in adult and fetal bloods. Author investigated the effects of hemoglobin itself on the elimination of CO from mother and fetus. By observing the difference of CO dissociation from adult and fetal hemoglobin at the various partial pressures of oxygen, the author tries to suggest the base of the proper treatment measure for the CO poisoning of pregnant woman and newborn infant. The results were as follows: 1. The total hemoglobin amounts of adults and fetal bloods were $16.1{\pm}0.50gm%\;and\;15.7{\pm}0.32gm%$, respectively. The fetal hemoglobin proportions in adult and fetal bloods were $1.2{\pm}0.15%\;and\;72.7{\pm}3.01%$, respectively. 2. Adult and fetal bloods saturated by CO to 100% HbCO were exposed to ambient air$(21%\;O_2),\;100%\;O_2\;and\;3\;ATAO_2$. After 30 minutes exposure, the HbCO saturations of adult blood were 96.7%, 70.9%, and 52.8%, respectively, and those of fetal blood were 98.5%, 76.1%, and 62.2%, respectively. HbCO dissociation was proportional to the partial pressure of oxygen and the most marked dissociation was shown under 3 ATA $O_2$, HbCO dissociation of fetal blood was slower than that of adult blood in all conditions. According to the above results, it is possible that CO poisoning make more serious damage to the fetus and newborn infant than to the adult due to the delayed dissociation of HbCO. Thus in the treatment of CO poisoning of pregnant woman and newborn infant, hyperbaric oxygen therapy seems to be the most eflective treatment measure, but the duration of hyperbaric oxygenation should be lengthened accordingly.

  • PDF

On Using Near-surface Remote Sensing Observation for Evaluation Gross Primary Productivity and Net Ecosystem CO2 Partitioning (근거리 원격탐사 기법을 이용한 총일차생산량 추정 및 순생태계 CO2 교환량 배분의 정확도 평가에 관하여)

  • Park, Juhan;Kang, Minseok;Cho, Sungsik;Sohn, Seungwon;Kim, Jongho;Kim, Su-Jin;Lim, Jong-Hwan;Kang, Mingu;Shim, Kyo-Moon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.23 no.4
    • /
    • pp.251-267
    • /
    • 2021
  • Remotely sensed vegetation indices (VIs) are empirically related with gross primary productivity (GPP) in various spatio-temporal scales. The uncertainties in GPP-VI relationship increase with temporal resolution. Uncertainty also exists in the eddy covariance (EC)-based estimation of GPP, arising from the partitioning of the measured net ecosystem CO2 exchange (NEE) into GPP and ecosystem respiration (RE). For two forests and two agricultural sites, we correlated the EC-derived GPP in various time scales with three different near-surface remotely sensed VIs: (1) normalized difference vegetation index (NDVI), (2) enhanced vegetation index (EVI), and (3) near infrared reflectance from vegetation (NIRv) along with NIRvP (i.e., NIRv multiplied by photosynthetically active radiation, PAR). Among the compared VIs, NIRvP showed highest correlation with half-hourly and monthly GPP at all sites. The NIRvP was used to test the reliability of GPP derived by two different NEE partitioning methods: (1) original KoFlux methods (GPPOri) and (2) machine-learning based method (GPPANN). GPPANN showed higher correlation with NIRvP at half-hourly time scale, but there was no difference at daily time scale. The NIRvP-GPP correlation was lower under clear sky conditions due to co-limitation of GPP by other environmental conditions such as air temperature, vapor pressure deficit and soil moisture. However, under cloudy conditions when photosynthesis is mainly limited by radiation, the use of NIRvP was more promising to test the credibility of NEE partitioning methods. Despite the necessity of further analyses, the results suggest that NIRvP can be used as the proxy of GPP at high temporal-scale. However, for the VIs-based GPP estimation with high temporal resolution to be meaningful, complex systems-based analysis methods (related to systems thinking and self-organization that goes beyond the empirical VIs-GPP relationship) should be developed.

Studies on the Processing and Management Forms of Filatures (우리나라 제사공장의 공정 관리실태에 관한 조사연구)

  • 송기언;이인전
    • Journal of Sericultural and Entomological Science
    • /
    • no.12
    • /
    • pp.37-45
    • /
    • 1970
  • The processing management forms of our country's filature factories in 1969 are summarized as follows. (1) About 80% of total cocoon collection is made within 5 days involving peak day, and 10% of cocoon collection is finished until 3 days before and after the peak day, (2) About 92% of alive cocoons transported on unpaved road, and about 40% of the cocoons purchased by all factories are loaded on trucks from common selling station which is far beyond 40km, therefore a new packing system of alive cocoons to drop the damage of cocoon qualities, should be taken. (3) 22% of all factories in our. country have only low-temperature cocoon drying machine. Therefore the installment of hot-air cocoon drying machine is required urgently. (4) In view of cocoon qualities in our country, the grouping method of cocoon for reeling. taken by about 50% of the factories at percent, which classify cocoons for reeling as high group (1,2,3,4 grades) and low group(5,6 grades), will have to be replaced by the method tat classify them high group (1,2 grades) middle group (3,4 grades), low group (5,6 grades). (5) The .ratio of cocoon assorting stood about 10% in multi-ends reeling, about 15% in automatic reeling, conclusively, the ratio of cocoon assorting for automatic reeling was higher tan that for multi-ends reeling. One person's ability for a day in cocoon assorting reaches to about 80-100kg. (6) Cocoon cooking condition requires the increase of the cooking time, the pressure and temperature used to be prolonged as much as the qualities of cocoons are material cocoon ior automatic and double cocoon machines are treated uncompletely. (7) Automatic silk reeling is being performed at 1-2$^{\circ}C$ lower in reeling water temperature and operated at about twice velocity. (8) The temperature and humidity of rereeling room stood at 25$^{\circ}C$, 67.2% R.H and 32.3$^{\circ}C$, 51.9% R.H of rereeling machine are showed, Average rereeling velocity is 233m/min and large reefs charged for one person are 7.5 reels and form of skein used in all factories is double skein. (9) About 73% of water sources for filature used under-earth water. About 48% of all filature factories in our country have not yet water purifying equipments. Installation of the equipment for these factories seems to be urgent, (10) Denier .balance, sizing reel, seriplane, are being used in most factories as self-inspection apparatus. (11) More than 90% of the factories use the vacum tank in rereeling process and about 20% of them use it in cocoon cooing process (12) Only 21% of the factories use chemicals in filature process. About all them use "Seracol 100" in cocoon cooking process and "Seracol 500" in rereeling process, (13) Above survey results explain each all factories show large difference in the processing management. Therefore, it is believed that intercommunication through seminar or technical exchange will contribute to the production evaluation of cocoon in our filature industry.

  • PDF

Elevated C-reactive Protein Levels are a Sign of Pulmonary Arterial Hypertension in AECOPD (만성 폐쇄성 폐질환 급성 악화 시 C-반응단백과 폐동맥 고혈압의 관계)

  • Kim, So Ri;Choe, Yeong Hun;Lee, Ka Young;Min, Kyung Hoon;Park, Seoung Ju;Lee, Heung Bum;Lee, Yong Chul;Rhee, Yang Keun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.2
    • /
    • pp.125-132
    • /
    • 2008
  • Background: In chronic obstructive pulmonary disease (COPD) patients, the serum levels of C-reactive protein (CRP) are elevated and an increase of CRP is more exaggerated in the acute exacerbation form of COPD (AECOPD) than in stable COPD. Pulmonary arterial hypertension is a common complication of COPD. An increased level of CRP is known to be associated with the risk of systemic cardio-vascular disorders. However, few findings are available on the potential role of CRP in pulmonary arterial hypertension due to COPD. Methods: This study was performed prospectively and the study population was composed of 72 patients that were hospitalized due to AECOPD. After receiving acute management for AECOPD, serum CRP levels were evaluated, arterial oxygen pressure ($PaO_2$), was measured, and the existence of pulmonary arterial hypertension under room air inhalation was determined in the patients. Results: The number of patients with pulmonary arterial hypertension was 47 (65.3%)., There was an increased prevalence of pulmonary arterial hypertension and an increase of serum CRP levels in patients with the higher stages of COPD (e.g., patients with stage 3 and stage 4 disease; P<0.05). The mean serum CRP levels of patients with pulmonary arterial hypertension and without pulmonary arterial hypertension were $37.6{\pm}7.4mg/L$ and $19.9{\pm}6.6mg/L$, respectively (P<0.05). However, there was no significant difference of the mean values of $PaO_2$ between patients with pulmonary arterial hypertension and without pulmonary arterial hypertension statistically ($77.8{\pm}3.6mmHg$ versus $87.2{\pm}6.0mmHg). Conclusion: We conclude that higher serum levels of CRP can be a sign for pulmonary arterial hypertension in AECOPD patients.

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF