• Title/Summary/Keyword: diesel gas

Search Result 1,109, Processing Time 0.028 seconds

Numerical Study on the Impact of Power Plants on Primary PM10 Concentrations in South Korea

  • Park, Il-Soo;Song, Chang-Keun;Park, Moon-Soo;Kim, Byung-Gon;Jang, Yu-Woon;Ha, Sang-Sub;Jang, Su-Hwan;Chung, Kyung-Won;Lee, Hyo-Jung;Lee, Uh-Jeong;Kim, Sang-Kyun;Kim, Cheol-Hee
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.255-273
    • /
    • 2018
  • To develop effective emission abatement strategies for eighteen coal-fired power plants located throughout Korea, power plant emission data and TAPM (The Air Pollution Model) were used to quantify the impact of emission reductions on primary $PM_{10}$ concentrations. TAPM was validated for two separate time periods: a high $PM_{10}$ concentration period from April 7 to 12, 2016, and a low $PM_{10}$ concentration period from June 1 to June 6 2016. The validated model was then used to analyze the impacts of five applicable power plant shut-down scenarios. The results showed that shut-down of four power plants located within the Seoul metropolitan area (SMA) would result in up to 18.9% reduction in maximum $PM_{10}$ concentrations, depending on synoptic conditions. A scenario for the shutdown of a single low stack height with highest-emission power plant located nearest to Seoul showed a small impact on averaged $PM_{10}$ concentrations (~1%) and 4.4% ($0.54{\mu}g/m^3$) decrease in maximum concentration. The scenario for four shutdowns for power plants aged more than 30 years within SMA also showed a highest improvement of 6.4% ($0.26{\mu}g/m^3$ in April) in averaged $PM_{10}$ concentrations, and of 18.9% ($2.33{\mu}g/m^3$ in June) in maximum concentration, showing almost linear relationship in and around SMA. Reducing gaseous air pollutant emissions was also found to be significant in controlling high $PM_{10}$ concentrations, indicating the effectiveness of coreduction of power plant emissions together with diesel vehicle emissions in the SMA. In addition, this study is implying that secondary production process generating $PM_{10}$ pollution may be a significant process throughout most regions in Korea, and therefore concurrent abatement of both gas and particle emissions will result in more pronounced improvements in air quality over the urban cities in South Korea.

Empirical Analysis on Determinants of Air Pollution in China (중국의 대기오염 배출 결정요인에 대한 경험적 분석)

  • Li, Dmitriy D.;Wang, Wen;Bae, Jeong Hwan
    • Environmental and Resource Economics Review
    • /
    • v.29 no.1
    • /
    • pp.23-45
    • /
    • 2020
  • The rapid economic growth has brought tremendous pressure on the environment and caused severe air pollution in China. This study empirically examines causes of air pollution in China. Panel-corrected standard errors procedure (PCSE) was used to analyze major determinants of increasing or reducing emissions of sulfur dioxide (SO2) and nitrogen oxides (NOX) in 30 Chinese provinces. The estimation results show that SO2 emission is mitigated as per capita regional GDP increases, but the relation between emission of NOX and per capita regional GDP is found to have an inverse N-shaped curve, which implies that emission of NOX is ultimately expected to decline with economic growth. As for increasing factors of air pollutants, electricity consumption is a significant common source of SO2 and NOX emissions. Moreover, the results show that increment of coal consumption significantly affects emission of SO2 while increase of natural gas consumption reduce emission of SO2. On the other side, investment in energy industry, and investment on treatment of waste gases are determinants of mitigating emissions of SO2, but have no impact on NOX. Consumption of diesel, truck ratio and number of vehicles increase emission of NOX. Meanwhile, higher precipitation rate is a common determinant of mitigating emissions of SO2 and NOX. Policy implications are suggested in the conclusion.

New Technology Development for Production of Alternative Fuel Oil from Thermal Degradation of Plastic Waste (폐플라스틱의 열분해에 의한 대체 오일 생산의 신기술 개발)

  • Lee, Kyong-Hwan;Roh, Nam-Sun;Shin, Dae-Hyun
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2005.10a
    • /
    • pp.34-46
    • /
    • 2005
  • For treating a huge amount of plastic waste with the environment problem, pyrolysis of plastic waste into alternative fuel oil is one of important issue in recycling methods. This study was introduced over the trend of generation of plastic waste, pyrolysis technology in domestic and foreign countries, basic technology in pyrolysis process and new technology of pyrolysis developed in KIER (Korea Institute of Energy Research). The characteristics of process developed in KIER are the continuous loading treatment of mixed plastic waste with an automatic control system, the minimization of wax production by circulation pyrolysis system in non-catalytic reactor, the reuse of gas produced and the oil recovery from sludge generated in pyrolysis plant, which have greatly the advantage economically and environmetally. The experiment result data in 300 ton/yr pilot plant showed about 81 wt% liquid yield for 3 days continuous reaction time, and also the boiling point distribution of light oil (LO) and heavy oil (HO) produced in distillation tower was a little higher than that of commercial gasoline and diesel, respectively.

  • PDF

Characteristics Evaluation on Welding Metal Zones Welded with Inconel 625 Filler Metal to Cast Steel for Piston Crown Material

  • Jeong, Jae-Hyun;Moon, Kyung-Man;Lee, Sung-Yul;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.542-547
    • /
    • 2015
  • Since the oil price has been significantly jumped for several years, a heavy oil of low quality has been mainly used in the diesel engine of the merchant ship. Thus, a combustion chamber of the engine has been often exposed to severely corrosive environment more and more because temperature of the exhaust gas of the combustion chamber has been getting higher and higher with increasing of using the heavy oil of low quality. As a result, wear and corrosion of the engine parts such as exhaust valve, piston crown and cylinder head surrounded with combustion chamber are more serious compared to the other parts of the engine. Therefore, an optimum repair welding for these engine parts is very important to prolong their lifetime in a economical point of view. In this study, Inconel 625 filler metal were welded with GTAW method in the cast steel which would be generally used with piston crown material. And the corrosion properties of weld metal, heat affected and base metal zones were investigated using electrochemical methods such as measurement of corrosion potential, anodic polarization curves, cyclic voltammogram and impedance etc. in 35% $H_2SO_4$ solution. The weld metal and base metal zones exhibited the highest and lowest values of hardness respectively. Furthermore, the corrosion current density of the weld metal zone revealed the lowest value, having the highest value of hardness. The corrosive products with red color and local corrosion like as a pitting corrosion were considerably observed at the base metal zone, while these morphologies were not wholly observed in the weld metal zone. In particular, the polarization characteristics such as impedance, polarization curve and cyclic voltammogran associated with corrosion resistance property were well in good agreement with each other. Consequently, it is suggested that the mechanical and corrosion characteristics of the piston crown can be predominantly improved by repair welding method using the Inconel 625 electrode.

An Evaluation of Energy Quality for Distributed Powersystem (분산형 발전설비 병열운전 에너지 품질평가)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Yoon, Gi-Gab;Rhim, Sang-Kyu;Choi, In-Kyu
    • Journal of Energy Engineering
    • /
    • v.19 no.1
    • /
    • pp.8-15
    • /
    • 2010
  • As environmental friendly energy system, distributed micro gasturbine is focused on new energy source for overcoming brand new construction area of power generation. This distributed micro gasturbine system has the powerful characteristics as belows; 1) environmental friendly features NOx < 9 ppm, noise < 65 db 2) various fuel flexbility which is used such as natural gas, diesel, low calory new & renewable fuel, kerosene. 3) high specific output power based on small area and is avilable for very easy and compact installation. There are many new installation sites in USA and Japan from 1998. On the other hand the exhisting large power system was constructued by the sea side, this compact power system is now installed by enduser in downtown area and supplying combined heat & power, has the various apllication on-site power generation. In recently, there is the very important issue for new & reliablbe energy development and spreading out. This paper represent as belows for important system characteristics; 1) grid connection modeling 2) system operation characteristics 3) on-site operation result and evaluation output of power quality analysis.

Concentration of $NO_2$ and $SO_{2}$ of Bus Terminals in Seoul (서울시 버스터미널의 이산화질소 및 아황산가스 농도)

  • 손부순;장봉기;김영규
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.51-59
    • /
    • 1997
  • In this study, we researched the concentration of nitrogen dioxide($NO_{2}$) and sulfur dioxide($SO_{2}$) of indoor(waiting room) and outdoor(place of getting on the bus) at the bus terminals (Kang-Nam, Dong-Seoul and Nam-Bu) in Seoul to recognize the degree of pollution by exhaust gas of the diesel engine vehicles, and examine the factor that might affect air pollution of terminals. The concentration of $NO_{2}$ and $SO_{2}$ were measured in winter and summer, and the results of the analysis are as follows : The mean concentration of $NO_{2}$ was $57.49{\pm}21.86$ ppb and the concentration of outdoor with $64.10{\pm}27.69$ ppb was significantly higher than the indoor with $50.89{\pm}10.92$ ppb (p<0.05), and the highest with $73.54{\pm}25.54$ ppb at Kang-Nam terminal (p<0.01). The mean concentration of $NO_{2}$ was $62.80{\pm}24.74$ ppb in winter and $52.19{\pm}17.50$ ppb in summer, and had a not statistical difference. The mean concentration of $SO_{2}$ was $31.71{\pm}8.73$ ppb and the concentration of outdoor with $31.04{\pm}8.89$ ppb was similar to the indoor $32.29{\pm}8.70$ ppb, and the highest with $32.57{\pm}9.01$ ppb at Dong-Seoul terminal (p<0.05). The mean concentration of $SO_{2}$ in winter with $39.67{\pm}4.10$ ppb was significantly higher than in summer with $23.76{\pm}2.61$ ppb (p<0.01). The concentration of outdoor $NO_{2}$ at Kang-Nam terminal was 104, 84 ppb in winter and 81.20 ppb in summer, and had a statistical difference compared with the concentration of indoor $NO_{2}$ at Dong-Seoul and Nam-Bu terminals. The concentration of indoor $NO_{2}$ and $SO_{2}$ were higher than that of outdoor at Kang-Nam and Dong-Seoul terminals, but on the contrary, lower than that of outdoor at Nam-Bu terminal. The concentration of $NO_{2}$ and $SO_{2}$ at Nam-Bu terminal were lower than those at Kang-Nam and Dong-Seoul terminals. While the concentration of $SO_{2}$ show the large difference between winter and summer, that of $NO_{2}$ dose not.

  • PDF

Impact of the Exclusive Median Bus Lane System on Air Pollution Concentrations in Seoul, Korea (서울시 중앙버스전용차로 도입의 부가적인 대기오염 영향성 평가)

  • Baik, Yeon-Ju;Kim, Da-Wool;Kwon, Hye-Young;Kim, Youngkook;Kim, Sun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.4
    • /
    • pp.542-553
    • /
    • 2018
  • Since many previous studies reported the health effect of air pollution and indicated traffic as a major pollution source, significant policy efforts have been made to control traffic to reduce air pollution. However, there have been few studies that evaluated such policy implementation. In Seoul, Korea, the exclusive median bus lane system was implemented in 2004, and the metropolitan government applied air pollution reduction policies such as conversion of diesel buses to compressed natural gas buses and installation of emission control devices. This paper aimed to investigate the impact of the exclusive median bus lane system on air pollution reduction. Using hourly concentrations of particulate matter ($PM_{10}$) and nitrogen dioxide ($NO_2$) measured at 131 regulatory monitoring sites in Seoul and Gyeonggi-do for 2001-2014, we calculated annual and daily average concentrations at each site. We assessed the impact of the policy using differences-in-differences analysis by annual and daily average models after adjusting for geographic and/or meteorological variables. This method divides population into treatment and control groups with and without policy application, and compares the difference between the two time periods before and after the policy implementation in the treatment group with the difference in the control group. We classified all monitoring sites into treatment and control groups using two definitions: 1) Seoul vs. Gyeonggi-do; 2) within vs. outside 300 meters from the median bus lane. Pre- and post-policy periods were defined as 2001-2005 and 2006-2014, and 2004 and 2014 in the annual and daily models, respectively. The decrease in $PM_{10}$ concentrations between the two periods across monitoring sites in the treatment group was larger by $1.73-5.88{\mu}g/m^3$ than in the control group. $NO_2$ also showed the decrease without statistical significance. Our findings suggest that an efficient public transport policy combined with pollution abatement policies can contribute to reduction in air pollution.

The analysis of Change on Property and CO2 Emission Factor of Domestic Transportation Fuel from 2012 to 2015 (2012 ~ 2015년 국내 수송용 연료의 물성 및 CO2 배출계수의 변화추이 분석연구)

  • Kang, Hyungkyu;Doe, Jinwoo;Lim, Wanguy;Hwang, Inha;Ha, Jonghan;Na, Byungki
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.4
    • /
    • pp.855-863
    • /
    • 2016
  • Most greenhouse gases were arisen from the generation and use of energy, more than about 95 % of greenhouse gas from the traffic section was resulted by the transportation fuels. Also, when using the $CO_2$ emission factor suggested at IPCC G/L, there was the weakness which did not reflect the own property of fuel by country. And most industrialized countries have applied with the $CO_2$ emission factor of Tier 2 or Tier 3 to make the national greenhouse report to submit to UN according to the Kyoto Protocol. In this study, the transportation fuels using in domestic like unleaded gasoline, diesel, etc were analysed to identify the physical/chemical properties and these data were used to calculate the $CO_2$ emission factor of each fuels. And the study analysed the time series analysis to compare the property of fuels according to the change of time.

Evaluation of the corrosion property on the welded zone of forged steel piston crown with types of filler metals (용접재료별 단강 피스톤 크라운 용접부위의 부식특성에 대한 평가)

  • Moon, Kyung-Man;Won, Jong-Pil;Lee, Myeong-Hoon;Baek, Tae-Sil;Kim, Jin-Gyeong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.409-417
    • /
    • 2014
  • Since the oil price has been significantly jumped for recent some years, the diesel engine of the merchant ship has been mainly used the heavy oil of low quality. Thus, it has been often exposed to severely corrosive environment more and more because temperature of the exhaust gas in a combustion chamber is getting higher and higher with increasing of using the heavy oil of low quality. As a result, wear and corrosion of most parts surrounded with combustion chamber is more serious compared to the other parts of the engine. Therefore, an optimum weldment for these parts is very important to prolong their lifetime in a economical point of view. In this study, four types of filler metals such as Inconel 625, 718, 1.25Cr-0.5Mo and 0.5Mo were welded with SMAW and GTAW methods in the forged steel which would be generally used with piston crown material. And the corrosion properties of weld metal, heat affected zone and base metal were investigated using electrochemical methods such as measurement of corrosion potential, anodic polarization curves, cyclic voltammogram and impedance etc. in 35% H2SO4 solution. The weld metal and base metal exhibited the best and worst corrosion resistance in all cases of filler metals. In particular, the weld metal welded with filler metals of Inconel 718 revealed the best corrosion resistance among the filler metals, and Inconel 625 followed the Inconel 718. Hardness relatively indicated higher value in the weld metal compared to the base metal. Furthermore, Inconel 625 and 718 indicated higher values of hardness compared to 1.25cr-0.5Mo and 0,5Mo filler metals in the weld metal.

Study of NO Storage and Reduction on LNT by Micro Bench-Flow Reactor (마이크로 벤치-플로우 리액터를 이용한 LNT 촉매의 NO 흡장과 정화성능에 관한 연구)

  • Yoon, Joo-Wung;Hwang, Seung-Kwon;Hwang, In-Goo;Park, Sim-Soo;Lee, Jin-Ha;Yeo, Gwon-Koo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.789-798
    • /
    • 2011
  • We carry out an experimental investigation to analyze the basic performance of NO(nitric oxide) storage in a lean phase and also analyze the NO reduction achieved by the spraying of reducing agents in the rich phase of the exhaust gas in an LNT(Lean NOx Trap). This is an after-treatment system used to reduce the NOx emissions from a diesel engine. If the stored NO is reduced, we measure the outlet concentration downstream of the LNT. The test LNT material used in the experiments is commercial LNT. After being canned into stainless-steel(SUS304), it was built in a micro bench-flow reactor. Compositions of feed gases, three heated and three no heated gases were sprayed upstream of the LNT to analyze the characteristics. We use various temperatures and space velocities as response variables.