• 제목/요약/키워드: dielectric experiments

검색결과 205건 처리시간 0.023초

Dielectric packed-bed 플라즈마 반응기를 사용한 NOx 제거 특성 (NOx removal characteristics by the dielectric packed-bed plasma reactor)

  • 김응복;김동욱;정영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1087-1089
    • /
    • 1999
  • This paper presents the removal characteristics of nitrogen oxides (NOx) by the dielectric ($Al_{2}O_{3}$) packed-bed plasma reactor. Reactor packed with 5-mm diameter $Al_{2}O_{3}$ beads, and was designed to remove NOx at atmospheric pressures from the moving pollution source such as diesel automobile. The experiments were conducted for applied voltages from 5 to 10kV, flue gas rate from 2 to 5L/min, and frequency from 0.5 to 2kHz. The NOx removal efficiency significantly increased with increasing applied voltage. Especially removal rate significantly increased with increasing frequency. However, in this experiment discharge power was relatively high.

  • PDF

비유전율을 이용한 공기감지장치에 관한 연구 (A study on the air detector using relative dielectric constant)

  • 이혁수;김청월
    • 센서학회지
    • /
    • 제16권5호
    • /
    • pp.384-388
    • /
    • 2007
  • Air embolism can be a lethal complication of surgical procedures during which venous pressure at the site of surgery is sub-atmospheric or air is forced under pressure into a body cavity. To solve the problem, we developed the air detector using relative dielectric constant change, which is expected to be used broadly in industrial circles. We designed a detection circuit of sensing scheme. In experiments with a mock system, the proposed system showed a signal difference depending on the amount of air in the tygon tube of the mock system.

Dielectric packed-bed 플라스마 반응기를 사용한 NOx 제거 특성에 관한 연구 (NOx Removal Characteristics by the Dielectric Packed-bed Plasma Reactor)

  • 김응복;김동욱;정영식;최충석;김용하
    • 한국안전학회지
    • /
    • 제16권3호
    • /
    • pp.41-44
    • /
    • 2001
  • The removal characteristics of nitrogen oxides (NOx) by the dielectric ($Al_2O_3$) packed-bed plasma reactor are experimentally investigated Reactor is packed with 5[mm] diameter $Al_2O_3$ beads, and was desisted to remove NOx at atmospheric pressures from the moving pollution source such as diesel automobile. The experiments were conducted for applied voltages from 5 to 10[kV], flue gas rate from 2 to 5[l/min] and frequency from 0.5 to 2[kHz]. The NOx removal efficiency significantly increasing with increasing applied voltage. Especially removal rate significantly increased with increasing frequency. However, in this experiment discharged poler n relatively high.

  • PDF

Electrical/Microstructural Characterization of Dielectric Thin Films Prepared on Transparent Substrates

  • You, Iyl-Hwan;Hwang, Jin-Ha
    • 반도체디스플레이기술학회지
    • /
    • 제7권1호
    • /
    • pp.53-57
    • /
    • 2008
  • $Pb(ZrTi)O_3$ thin films were prepared on transparent conducting oxides, through sol-gel processing. The processing variables such as spin velocity, spin time and annealing temperature were investigated using a statistical design of experiments. Dielectric properties were determined through capacitance-voltage measurements and electrical characterizations evaluated using current-voltage characteristics. The leakage currents is determined mainly by annealing. The capacitance and breakdown voltage is found to be independent of the processing variables. The sophisticatedly controlled PZT thin films have been confirmed through microscopic images.

  • PDF

고분자유전체를 이용한 동적 점자출력기 (Dynamic Braille Display Using Dielectric Elastomer)

  • 최혁렬;이상원;정광목;이성일;최후곤;전재욱;남재도
    • 제어로봇시스템학회논문지
    • /
    • 제9권8호
    • /
    • pp.592-599
    • /
    • 2003
  • As one of the Principal modalities of human sensation, tactile feel is prerequisite for building wide variety of applications such as telemanipulation, virtual reality and medical engineering. A dynamic Braille display device based on a polymer actuator is presented. The actuator, often called artificial muscle actuator has advantageous features over the existing methods in terms of intrinsic softness, ease of fabrication, cost-effectiveness and miniaturization. The principles of actuation with dielectric elastomer is introduced, and necessary considerations on the design of a tactile display device are discussed. The design of the device is described in detail including the fabrication process and driving electronics. Also, preliminary results of experiments are given to evaluate its performance.

접지된 유전체판 위에 위치한 스트립 격자에 TM편파된 평면파가 입사되는 경우에서의 Bragg 및 Off-Bragg blazing 현상-실험 (Experiments of bragg and off-bragg blazing phenomena by strip grating over a grounded dielectric slab for TM polarization Case)

  • 백운석;조웅희;이종익;이철훈;홍재표;조영기;손현
    • 한국통신학회논문지
    • /
    • 제22권4호
    • /
    • pp.605-610
    • /
    • 1997
  • An analysis method for the electromagnetic scattering of a Tm polarized plane wave from a periodic strip grating over a grounded dielectric slab is considered from the viewpoint of reflection grating problem. The parameters of strip gratings showing Bargg and Off-Bragg blazing phenomena at the frequency of 10GHz are derived teoretically. The strip grating structure is implemented using Aluminum plate(groung conductor), paraffin(dielectric material.epsilon.$_{r}$=2.24), and copper(strip conductor0.08m thickness). The experimental results(reflection power) of Bragg as well as Off-Bragg blazing phenomenon for TM polarized plane wave have been compared with the theoretical results and fairly good agreements between theory and experiment have been observed.d.

  • PDF

수중 방전을 이용한 유해 세균 검출 분석 연구 (A study on Harmful Bacillus Detection used discharge in water)

  • 조국희;김영배;조문수;박보현;신광철;이동훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.285-289
    • /
    • 2004
  • In this research, we used discharge tube without dielectric bead or with dielectric beads$(SiO_2,\;Al_2O_3,\;or\;ZrO_2)$ for removal of Escherichia coli. At the result of experiments, the removal characteristics of Escherichia coli appeared relation ratio to input voltage. Because, the electric field of discharge tube is increased when input voltage is increased. And, discharge tube used dielectric $bead(ZrO_2)$, the removal characteristics of Escherichia coli was better than cases of else.

  • PDF

자켓 컴팍운드용 절연재의 수증기투과 및 절연파괴 특성 (Characterization of Water Vapor Transmission & Dielectric Breakdown in Insulation Materials for Jacket Compound)

  • 송재주;한재홍;송일근;한용희;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.52-56
    • /
    • 2001
  • Experiments of 2 type on insulating compounds accomplished to change PVC using in URD(Underground) power cable jacketing. one was DB(Dielectric Breakdown) test on the pure base resins and the others were WVT(Water Vapor Transmission) test on the compounds which contained C/B(Carbon Black), anti-oxidant to base resin. a kind of specimens made by pressing to resin of pellet or lump form was HDPE(High Density Polyethylene), MDPE(Medium Density Polyehylene), LDPE(Low Density Polyethylene), LLDPE(Linear Low Density Polyethylene), PVC(Polyvinyl Chloride). As a results of AC DB and WVT test, we saw that strength of Insulation was HDPE> LLDPE = MDP E> LDPE and WVT ratio was HDPE

  • PDF

유해 세균 제거 분석 연구 (A study on Harmful Bacillus Removal Analysis)

  • 조국희;김영배;조문수;박보현;신광철;이동훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.38-42
    • /
    • 2004
  • In this research, we used discharge tube without dielectric bead or with dielectric beads($SiO_2$, $Al_2O_3$, or $ZrO_2$), and discharge in water for removal of Escherichia coli. At the result of experiments, the removal characteristics of Escherichia coli appeared relation ratio to input voltage. Because, the electric field of discharge tube is increased when input voltage is increased. And, discharge tube used dielectric bead($ZrO_2$), the removal characteristics of Escherichia coli was better than cases of else.

  • PDF

전극 간격에 따른 공기의 절연파괴 특성에 관한 연구 (A Study on the Electrical Breakdown Characteristics of Air according to Electrode Gap)

  • 강종오;이온유;김준일;방승민;이홍석;이종득;강형구
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.301-306
    • /
    • 2014
  • Recently in accordance with the rapid development of the industrial society, the accidents caused by dielectric breakdown have been increasing in power grid. It is important to prevent the dielectric breakdown of a high voltage apparatus to reduce the damage from electrical hazards. To establish an electrically reliable database of insulation design criteria for high voltage apparatus, a study on dielectric characteristics test is indispensable. In this study, dielectric characteristics according to field utilization factors (${\xi}$) which are represented as the ratio of mean electric field to maximum electric field are investigated. the dielectric breakdown experiments by using several kinds of electrode systems made with stainless steel are performed by AC breakdown voltage under air-insulation. Also, the experimental results are analyzed by the Weibull distribution. As a result, it is found that the dielectric characteristics of air-insulation are determined by ${\xi}$ as well as arrangement of electrode systems. It is considered that the results of this study would be applicable to designing the air-insulated high voltage apparatuses.