• 제목/요약/키워드: diamond

검색결과 2,368건 처리시간 0.03초

상아질과 Gutta-Percha에 대한 근관충전용 Sealer의 결합강도의 측정 (MEASUREMENT OF ADHESION OF ROOT CANAL SEALER TO DENTINE AND GUTTA-PERCHA)

  • 허미자;유미경;이세준;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제28권1호
    • /
    • pp.89-99
    • /
    • 2003
  • The purpose of this study was to investigate the bonding of resin- based root canal sealer, AH26 when the sealer was applied as a thin layer between dentine and gutta-percha surface. In this study forty non-caries extracted human molars and resin-based root canal sealer(AH 26, DeTrey/Dentsply, Germany) were used. Disks of gutta-percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for thermoplastic obturation were used and dentin surfaces were treated with 2% NaOCl(Group 1) or 2%NaOCl+17% EDTA(Group 3). Disks of gutta-Percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for conventional obturation were used and dentin surface were treated with 2% NaOCl(Group 2) or 2%NaOCl+17% EDTA(Group 4). Enamel was removed by a horizontal section 1mm below the deepest portion of the central occlusal groove by using a watercooled low speed diamond saw. A second horizontal section was done around cementoenamel junction. Exposed dentin surface was cut to approximately $8{\times}8{\;}mm$ rectangular shape and was ground against 320, 400, 600 grade silicon carbide abrasive paper serially. After grinding, the dentine surface were soaked in a solution of 2% NaOCl for 30 minutes and twenty of specimens were treated with 17% EDTA solution for 1 minute. The treated specimens were washed and dried, Root canal sealer, AH26 was prepared according to the manufacture's instructions The Gutta-percha and dentin surface were coated with a thin layer of the freshly mixed seal or. The specimens were left overnight at room temperature. After their initial set, they were transferred to an incubator at $37$^{\circ}C$ for 72 h. After 72 hours, resin blocks were made. The resin block was serially sectioned vertically into stick of $1{\cdot}1mm$. Twenty sticks were prepared from each group. After that, tensile bond strength f3r each stick was measured with Microtensile Tester Failure patterns of the specimens at the interface between gutta-percha and dentin were observed under the SEM(x1000) and Stereomicroscope (LEICA M42O, Meyer Inst., TX U.S.A) at 1.25 x25 magnification. The results were statistically analysed by using a One-way ANOVA and Tukey's test. The results were as follows; 1. Tensile bond strengths($mean{\pm}SD$) were expressed with ascending order as follows: Group 1, $3.09{\pm}$ 1.05Mpa : Group 2, $6.23{\pm}1.16MPa$ : Group 3, $7.12{\pm}1.07MPa$ : Group 4, $10.32{\pm}2.06MPa$. 2. Tensile bond strengths of the group 2 and 4 used disks of gutta-percha for conventional obturation were significantly higher than that of the group 1 and 3 used fir thermoplastic obturation. (p < 0.05). 3. Tensile bond strengths of the group 3 and 4 treated with 2% NaOC1+17% EDTA were significantly higher than that of the group 1 and 2 treated with 2% NaOCl. (p < 0.05). 4. In analysis of failure patterns at the interface between sealer and gutta-percha, there were observed 49 (61%)cases of adhesive failure patterns and 31 (39%) cases of mixed failures patterns.

Flowable 및 microfill 복합레진으로 충전된 제 5급와동에서 load cycling 전,후의 미세변연누출 비교 (MICROLEAKAGE OF MICROFILL AND FLOWABLE COMPOSITE RESINS IN CLASS V CAVITY AFTER LOAD CYCLING)

  • 강석호;김오영;오명환;조병훈;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.142-149
    • /
    • 2002
  • Low-viscosity composite resins may produce better sealed margins than stiffer compositions (KempScholte and Davidson, 1988: Crim, 1989). Plowable composites have been recommended for use in Class V cavities but it is also controversial because of its high rates of shrinkage. On the other hand, in the study comparing elastic moduli and leakage, the microfill had the least leakage (Rundle et at. 1997) Furthermore, in the 1996 survey of the Reality Editorial Team, microfills were the clear choice for abfraction lesions. The purpose of this study was to evaluate the microleakage of 6 compostite resins (2 hybrids, 2 microfills, and 2 flowable composites) with and without load cycling. Notch-shaped Class V cavities were prepared on buccal surface of 180 extracted human upper premolars on cementum margin. The teeth were randomly divided into non-load cycling group (group 1) and load cycling group (group 2) of 90 teeth each. The experimental teeth of each group were randomly divided into 6 subgroups of 15 samples. All preparations were etched, and Single bond was applied. Preparations were restored with the following materials (n=15) : hybrid composite resin [Z250(3M Dental Products Inc. St. Paul, USA), Denfil(Vericom, Ahnyang, Korea)], microfill [Heliomolar RO(Vivadent, Schaan, Liechtenstein), Micronew(Bisco Inc. Schaumburg, IL, USA)], and flowable composite[AeliteFlo(Bisco Inc. Schaumburg, IL, USA), Revolution(Kerr Corp. Orange, CA, USA)]. Teeth of group 2 were subjected to occlusal load (100N for 50,000 cycles) using chewing simulator(MTS 858 Mini Bionix II system, MTS Systems Corp. Minn. USA). All samples were coated with nail polish 1mm short of the restoration, placed in 2% methylene blue for 24 hours, and sectioned with a diamond wheel. Enamel and dentin/cementum margins were analyzed for microleakage on a sclale of 0 (no leakage) to 3 (3/3 of wall). Results were statistically analyzed by Kruscal-Wallis One way analysis, Mann-Whitney U-test, and Student-Newmann-Keuls method. (p = 0.05) Results : 1. There was significantly less microleage in enamel margins than dentinal margins of all groups (p<0.05) 2. There was no significant between six composite resin in enamel margin of group 1. 3. In dentin margin of group 1, flowable composite had more microleakage than others but not of significant differences. 4. there was no significant difference between six composite resin in enamel margin of group 2. 5. In dentin margin of group 2, the microleakage were R>A =H=M>D>Z. But there was no significant differences. 6. In enamel margins, load cycling did not affect the marginal microleakage in significant degree. 7. In enamel margins, load cycling did affect the marginal microleakage only in Revolution. (p<0.05).

제오급와동(第五級窩洞) 수복(修復)에 사용(使用)되는 수종(數種) 충전재(充塡材)의 변연누출(邊緣漏出) 비교(比較) (COMPARISON OF THE MARGINAL LEAKAGE OF SEVERAL FILLING MATERIALS ON CLASS V CAVITIES)

  • 김미옥;조규징
    • Restorative Dentistry and Endodontics
    • /
    • 제14권2호
    • /
    • pp.20-29
    • /
    • 1989
  • 발거된 소구치 80개의 협, 설면에 교합면쪽의 법량질변연과 치은쪽의 상아질변연을 부여한 제 5급와동을 형성한 후, 각 20개씩 4개의 군으로 나누었다. 각 군별로 초미세입자형 광중합 복합레진과 법랑질접착체인 Durafill$^{(R)}$-Durafill bond$^{(R)}$, Bisfil M$^{(R)}$-Resin bond$^{(R)}$, 초미세입자형 복합레진과 상아질 접착제인 Silux$^{(R)}$-Scotchbond$^{(R)}$ 그리고 글라스 아이오노머 시멘트인 Fuji ionomer$^{(R)}$로 충전하였다. 온도변화는 $40^{\circ}C$$60^{\circ}C$의 2% methylene blue 용액에 각각 30초간 침척을 반복시킨 후 $37^{\circ}C$ 동용액에 24시간 경과시켜 법랑질변연부와 상아질변연부에서의 색소침투를 관찰하므로써 변연누출의 정도률 비교한 바 다움과 같은 결과를 얻었다. 1. 법랑질변연부에서 Durafill$^{(R)}$-Durafill bond$^{(R)}$, Bisfil M$^{(R)}$-Resin bond$^{(R)}$ 및 Silux$^{(R)}$-Scotchbond$^{(R)}$군 상호간에는 대차가 없었으나(P>0.05), 3군 공히 Fuji ionomer$^{(R)}$군보다는 변연누출이 적었다(P<0.01). 2. 상아질변연부에서는 Silux$^{(R)}$-Scotchbond$^{(R)}$군과 Fuji ionomer$^{(R)}$군이 각각 Durafill$^{(R)}$-Durafill bond$^{(R)}$군 및 Bisfil M$^{(R)}$-Resin bond$^{(R)}$군에 비해 변연누출이 적었다(P<0.01). 3. 충전한 모든군의 5급 와동에서 법랑질변연부가 상아질변연부보다 변연누출이 적었다(P<0.01).

  • PDF

Flowable Composite Resin의 미세변연누출 및 전단결합강도 (MICROLEAKAGE AND SHEAR BOND STRENGTH OF FLOWABLE COMPOSITE RESIN)

  • 박성준;오명환;김오영;이광원;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제26권4호
    • /
    • pp.332-340
    • /
    • 2001
  • Flowable composite resin has lower filler content, increased flow, and lower modules of elasticity. It is suggested that flowable composite resin can be bonded to the tooth structure intimately and absorb or dissipate the stress. Therefore, it may be advantageous to use flowable composite resin for the base material of class II restoration and for the class V restoraton. The purpose of this study was to evaluate the microleakage and shear bond strength of four flowable composite resins (Aeliteflo, Flow-It, Revolution, Ultraseal XT Plus) compared to Z100 using Scotchbond Multi Purpose dentin bonding system. To evaluate the microleakage, notch-shaped class V cavities were prepared on buccal and lingual surfaces of 80 extracted human premolars and molars on cementum margin. The teeth were randomly divided into non-thermocycling group (group 1) and thermocycling group (group 2) of 40 teeth each. The experimental teeth of each group were randomly divided onto five subgroups of eight samples (sixteen surfaces). The Scotchbond Multi-Purpose and composite resin were applied for each group following the manufacturer's instructions. the teeth of group 2 were thermocycled five hundred times between 5$^{\circ}C$ and 55$^{\circ}C$. The teeth of group 2 were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, and sectioned longitudinally with a diamond saw. The dye penetration on each of the specimen were observed with a stereomicioscope at $\times$20 magnification. To evaluate the shear bond strength, 60 teeth were divided into five groups of twelve teeth each. The experimental teeth were ground horizontally below the dentinoenamel junction, so that no enamel remained. After applying Scotchbond Multi-Purpose on the dentin surface, composite resin was applied in the shape of cylinder. The cylinder was 4mm in diameter and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. After shear bond strength measurement, mode of failure was evaluated with a stereomicroscope at $\times$30 magnification. All data were statistically analyzed by One Way ANOVA and Student-Newman-Keuls method. The correlation between microleakage and shear bond strength was analyzed by linear regression. The results of this study were as follows ; 1. In non-thermocycling group, the leakage value of Z100 was significantly lower than those of flowable composite resins at the enamel and dentin margin, margin, except that Revolution showed the lower leakage value than that of Z100 at the dentin margin (p<0.05). 2. In thermocycling group, the leakage values of Z100 and Ultraseal XT Plus were lower than those of other subgroup at the enamel and dentin margin, except that Flow-It showed the lower leakage value than that of Ultraseal XT Plus at the dentin margin (p<0.05). 3. The leakage value of Z100 and Ultraseal XT Plus in thermocycling group were not higher than that in non-thermocycling group at the enamel margin. The leakage value of Z100 in thermocycling group was not higher than that in non-thermocycling group at the dentin margin (p<0.05). 4. As for the shear bond strength measurement, there were no statistically significant differences among groups (p<0.05). The shear bond strengths given in descending order were as follows: Z100(16.81$\pm$2.98 MPa), Flow-It(14.8$\pm$4.43 MPa), Aeliteflo(14.34$\pm$3.69 MPa), Revolution(13.46$\pm$4.23 MPa), Ultraseal XT Plus(12.83$\pm$3.16 MPa). 5. Failure modes of all specimens were adhesive failures. 6. There was no correlation between microleakage and shear bond strength.

  • PDF

접착제 도포후 오염된 표면의 처리방법에 따른 복합레진의 전단결합강도와 미세누출 (SHEAR BOND STRENGTH AND MICROLEAKAGE OF COMPOSITE RESIN ACCORDING TO TREATMENT METHODS OF CONTAMINATED SURFACE AFTER APPLYING A BONDING AGENT)

  • 박주식;이석종;문주훈;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.647-656
    • /
    • 1999
  • The purpose of this study was to investigate the shear bond strength and marginal microleakage of composite to enamel and dentin according to different treatment methods when the applied bonding agent was contaminated by artificial saliva. For the shear bond strength test, the buccal and occlusal surfaces of one hundred twenty molar teeth were ground to expose enamel(n=60) and dentin surfaces(n=60). The specimens were randomly assigned into control and 5 experimental groups with 10 samples in each group. In control group, a bonding system(Scotchbond$^{TM}$ Multi-Purpose plus) and a composite resin(Z-100$^{TM}$) was bonded on the specimens according to manufacture's directions. Experimental groups were subdivided into 5 groups. After polymerization of an adhesive, they were contaminated with at artificial saliva on enamel and dentin surfaces: Experimental group 1 ; artificial saliva was dried with compressed air. Experimental group 2 ; artificial saliva was rinsed with air-water spray and dried. Experimental group 3 ; artificial saliva was rinsed, dried and applied an adhesive. Experimental group 4 ; artificial saliva was rinsed, dried, and then etched using phosphoric acid followed by an adhesive. Experimental group 5, artificial saliva was rinsed, dried, and then etched with phosphoric acid followed by consecutive application of both a primer and an adhesive. Composite resin(Z-100$^{TM}$) was bonded on saliva-treated enamel and dentin surfaces. The shear bond strengths were measured by universal testing machine(AGS-1000 4D, Shimaduzu Co. Japan) with a crosshead speed of 5mm/minute under 50kg load cell. Failure modes of fracture sites were examined under stereomicroscope. The data were analyzed by one-way ANOVA and Tukey's test. For the marginal microleakage test, Class V cavities were prepared on the buccal surfaces of sixty molars. The specimens were divided into control and experimental groups. Cavities in experimental group were contaminated with artificial saliva and those surfaces in each experimental groups received the same treatments as for the shear test. Cavities were filled with Z-100. Specimens were immersed in 0.5% basic fuchsin dye for 24 hours and embedded in transparent acrylic resin and sectioned buccolingually with diamond wheel saw. Four sections were obtained from the one specimen. Marginal microleakages of enamel and dentin were scored under streomicroscope and averaged from four sections. The data were analyzed by Kruskal-Wallis test and Fisher's LSD. The results of this study were as follows. 1. The shear bond strength to enamel showed lower value in experimental group 1(13.20${\pm}$2.94MPa) and experimental group 2(13.20${\pm}$2.94MPa) than in control(20.03${\pm}$4.47MPa), experimental group 4(20.96${\pm}$4.25MPa) and experimental group 5(21.25${\pm}$4.48MPa) (p<0.05). 2. The shear bond strength to dentin showed lower value in experimental group 1(9.35${\pm}$4.11MPa) and experimental group 2(9.83${\pm}$4.11MPa) than in control group(17.86${\pm}$4.03MPa), experimental group 4(15.04${\pm}$3.22MPa) and experimental group 5(14.33${\pm}$3.00MPa) (p<0.05). 3. Both on enamel and dentin surfaces, experimental group 1 and 2 showed many adhesive failures, but control and experimental group 3, 4 and 5 showed mixed and cohesive failures. 4. Enamel marginal microleakage was the highest in experimental group 1 and there was a significant difference in comparison with other groups (p<0.05). 5. Dentin marginal microleakages of experimental group 1 and 2 were higher than those of other groups (p<0.05). This result suggests that treatment methods, re-etching with 35% phosphoric acid followed by re-application of adhesive or repeating all adhesive procedures, will produce good effect on both shear bond strength and microleakage of composite to enamel and dentin if the polymerized bonding agent was contaminated by saliva.

  • PDF

텅스텐 화학적-기계적 연마 공정에서 부식방지막이 증착된 금속 컨디셔너 표면의 전기화학적 특성평가 (Electrochemical Characterization of Anti-Corrosion Film Coated Metal Conditioner Surfaces for Tungsten CMP Applications)

  • 조병준;권태영;김혁민;;박문석;박진구
    • 마이크로전자및패키징학회지
    • /
    • 제19권1호
    • /
    • pp.61-66
    • /
    • 2012
  • 반도체 산업에서 회로의 고집적화와 다층구조를 형성하기 위해 화학적-기계적 연마(CMP: Chemical-Mechanical Planarization) 공정이 도입되었으며 반도체 패턴의 미세화와 다층화에 따라 화학적-기계적 연마 공정의 중요성은 더욱 강조되고 있다. 화학적-기계적 연마공정이란 화학적 반응과 기계적 힘을 동시에 이용하여 표면을 평탄화하는 공정으로, 화학적-기계적 연마 공정은 압력, 속도 등의 공정조건과, 화학적 반응을 유도하는 슬러리(Slurry), 기계적 힘을 위한 패드 등에 의해 복합적으로 영향을 받는다. 패드 컨디셔닝이란 컨디셔너가 화학적-기계적 연마 공정 중에 지속적으로 패드 표면을 연마하여 패드의 손상된 부분을 제거하고 새로운 표면을 노출시켜 패드의 상태를 일정하게 유지시키는 것을 말한다. 한편, 금속박막의 화학적-기계적 연마 공정에 사용되는 슬러리는 금속박막과 산화반응을 하기 위하여 산화제를 포함하는데, 산화제는 금속 컨디셔너 표면을 산화시켜 부식을 야기한다. 컨디셔너의 표면부식은 반도체 수율에 직접적인 영향을 줄 수 있는 스크래치(Scratch) 등을 발생시킬 뿐만 아니라, 컨디셔너의 수명도 저하시키게 되므로 이를 방지하기 위한 노력이 매우 중요하다. 본 연구에서는 컨디셔너 표면에 슬러리와 컨디셔너 표면 간에 일어나는 표면부식을 방지하기 위하여 유기박막을 표면에 증착하여 부식을 방지하고자 하였다. 컨디셔너 제작에 사용되는 금속인 니켈과 니켈 합금을 기판으로 하고, 증착된 유기박막으로는 자기조립단분자막(SAM: Self-Assembled Monolayer)과 불화탄소(FC: FluoroCarbon) 박막을 증착하였다. 자기조립단분자막은 2가지 전구체(Perfluoroctyltrichloro silane(FOTS), Dodecanethiol(DT))를 사용하여 기상 자기조립 단분자막 증착(Vapor SAM) 방법으로 증착하였고, 불화탄소막은 10 nm, 50 nm, 100 nm 두께로 PE-CVD(Plasma Enhanced-Chemical Vapor Deposition, SRN-504, Sorona, Korea) 방법으로 증착하여 표면의 부식특성을 평가하였다. 표면 부식 특성은 동전위분극법(Potentiodynamic Polarization)과 전기화학적 임피던스 측정법(Electrochemical Impedance Spectroscopy(EIS)) 등의 전기화학 분석법을 사용하여 평가되었다. 또한 측정된 임피던스 데이터를 전기적 등가회로(Electrical Equivalent Circuit) 모델에 적용하여 부식 방지 효율을 계산하였다. 동전위분극법과 EIS의 결과 분석으로부터 유기박막이 증착된 표면의 부식전류밀도가 감소하고, 임피던스가 증가하는 것을 확인하였다.

다양한 IPS Empress Esthetic$^{(R)}$ ingot으로 제작한 laminate veneer의 최종 색조에 대한 영향 (Influencing factors on the final color of laminate veneer restorations with various IPS Empress Esthetic$^{(R)}$ ingots)

  • 양미선;김석규
    • 대한치과보철학회지
    • /
    • 제49권4호
    • /
    • pp.308-315
    • /
    • 2011
  • 연구 목적: IPS Empress Esthetic$^{(R)}$ system의 ingot은 다양한 반투명도를 가지고 있지만, 실제 다양한 색조의 자연치를 배경으로 각각의 ingot을 laminate veneer로 제작했을 때 어느 정도의 차폐능력을 나타내는지 알 수 없다. 본 연구의 목적은 반투명도가 서로 다른 ingot으로 제작한 IPS Empress Esthetic$^{(R)}$ laminate veneer 수복 시 다른 색상의 지대치상에서 최종 색조의 차이(color difference, ${\Delta}E$)를측정, 분석해서 그 차폐효과를 평가하고, 최종 색조에 미치는 영향을 알아보고자 하였다. 연구 재료 및 방법: Laminate veneer 수복을 위해 삭제된 6가지 다른 색조(A1, A3, A4, B2, B3, C3)의 자연치아 위에 반투명도가 서로 다른 6가지 IPS Empress Esthetic$^{(R)}$ ingot (E 01, E 03, E OC1, E TC1, E TC2, E TC3)으로 제작된 총 두께 0.6 mm의 도재 시편들을 translucent shade의 시적용 합착제로 시적한 뒤 각 시편 조합의 색조를 색채계(colorimeter)를 이용하여 측정하였다. 서로 다른 색조의 지대치아 위에서 측정된 도재시편들의 색차를 비교, 분석하였다. 결과: 지대치 색조 및 coping의 반투명도에 따라서 laminate veneer 수복물의 최종 색조가 다르게 나타났다(P<.05). 모든 도재 시편에서 A3, B3, 그리고 C3 shade를 가진 지대치들 사이의 평균 색차값(${\Delta}E$)이 2.7 이하로 나타났고, 지대치들 간의 색조가 A3 와 A4, B3 와 A4, 그리고 C3 와 A4 인 경우 평균 색차값은 몇 가지 도재 시편에서 2.7 이하를 나타내어 laminate veneer 수복물에 의한 지대치 색조의 차폐효과를 보여 주었다. 반면, A1 과 B2 shade의 지대치는 다른 지대치들과 비교하여 높은 색조 차이를 보였으며, 특히A4와 B2, A3 와 B2, 그리고 A1 과 A4 색조의 지대치들 사이에는 그 색조 차이가 컸다. 결론: IPS Empress Esthetic$^{(R)}$ coping으로 제작된 laminate veneer의 최종 색조는 지대치 색조 및 coping의 반투명도에 의해 영향을 받았다. 서로 다른 $a^*$$b^*$ 값을 나타내는 지대치들의 색상 차이는 어느 정도 차폐 되는 효과를 보여주고 있으나, 명도($L^*$)의 차이가 많이 나타나는 지대치 색조들을 차폐하는 것은 한계가 있었다.

접착시스템의 소수성이 Low-shrinkage silorane resin과 상아질의 미세인장강도에 미치는 영향 (Effect of adhesive hydrophobicity on microtensile bond strength of low-shrinkage silorane resin to dentin)

  • 조소연;강현영;김경아;유미경;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제36권4호
    • /
    • pp.280-289
    • /
    • 2011
  • 연구목적: 본 연구의 목적은 다양한 소수성을 지닌 최신 상아질 접착시스템과 저수축 silorane 레진의 미세인장결합강도를 평가하는 것이다. 연구 재료 및 방법: 36개의 갓 발치된 제3대구치를 이용했다. Low-speed diamond saw를 사용하여 교합면에 평행하게 치관을 잘라 middle dentin을 노출시켰다. 치아를 무작위로 9 group으로 나눴다. Silorane self-etch adhesives (SS), SS + phosphoric acid etching (SS + pa), Adper Easy bond (AE), AE + Silorane system bonding (AE + SSb), Clearfil SE bond (CSE), CSE + SSb, All-Bond 2 (AB2), AB2 + SSb, All-Bond 3 (AB3). 접착제를 적용한 후에 Filtek LS (3M ESPE)를 2 mm씩 3회 적층충전하였다. 각 층은 40s씩 광중합하였다. 0.8 mm ${\times}$ 0.8 mm stick을 Micro Tensile Tester로 1 mm/min cross-head speed의 인장력을 가하였다. 파절양상를 관찰하기 위해 광학현미경을 이용하였다. 5가지 접착제의 소수성정도를 결정하기위해 water sorption test하였다. 결과: silorane 레진과 5가지 접착제의 ${\mu}TBS$: SS, 23.2 ${\pm}$ 6.9 MPa; CSE, 19.4 ${\pm}$ 4.4 MPa; AB3, 30.3 ${\pm}$ 4.0 MPa; AB2와 AE, no bond. Additional layering of SSb: CSE + SSb, 26.2 ${\pm}$ 10.3 MPa; AB2 + SSb, 33.9 ${\pm}$ 7.3 MPa; AE + SSb, no bond. 높은 ${\mu}TBS$는 cohesive failure와 관련있었다. SS는 낮은 가장 낮은 water sorption을 보였고 다음으로 AB3, AE, CSE, AB2 순서였다. AE는 가장 높은 용해도를 나타냈고 다음으로 CSE, AB2였다. 결론: 접착제의 소수성이 증가할수록, silorane 레진의 접착강도도 증가하였다. 비전용접착제 위에 silorane adhesive bonding을 layering하는 것은 AB2 + SSb 그룹에서만 결합강도를 유의하게 증가시켰다. AB3는 SS와 유사한 ${\mu}TBS$ & water sorption을 나타냈다. 따라서 AB3는 siloran resin을 접착시키는데 SS를 대체할만한 경쟁력있는 접착제이다.

설측 복합레진 색상이 치아 순측 색상에 미치는 영향 (INFLUENCE OF THE COLOR OF COMPOSITE RESINS APPLIED TO LINGUAL SURFACE ON THE LABIAL TOOTH COLOR)

  • 문승희;박수정;조현구;황윤찬;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제34권4호
    • /
    • pp.309-323
    • /
    • 2009
  • 본 연구는 순면 잔존 치질의 두께와 후방 복합레진의 색상이 최종 수복된 치아표면의 색상에 미치는 영향을 알아보고자 시행하였다. 배경판으로 사용될 복합레진은 Filtek Supreme (3M ESPE, St. Paul, U.S,A.)의 A1, A2, A6D, B1, B2, B3, C1, C2, C6D를 선택하였다. 배경판으로 사용될 복합레진 시편은 직경 10 mm, 두께 4.5 mm로 각 shade당 한 개씩 제작하였다. 순면 잔존 치질은 상악 중절치 치관의 순면을 제외한 나머지 부위를 아크릴릭 레진을 이용하여 매몰 후 저속의 Diamond Wheel Saw (Isomet ; Buehler Ltd, Lake Bluff, U.S.A.)를 이용하여 주수 하에 순면으로부터 2.5 mm 두께로 절단하였다. 절단된 상아질측 표면을 2000번 사포로 연마하여 2.2 mm 두께의 시편을 얻었다. 분광광도계 $Spectrolino^{(R)}$(Serial No. 3257-18522, GretagMacbeth, Regensdorf, Switzerland)를 이용하여 치아 시편을 9개의 복합레진 시편위에 접촉면에 수분이 있는 상태로 위치시켜 치아 순면색상을 측정하였다. 그 후, 치아시편의 상아질 측면을 1.0 mm까지 0.3 mm 간격으로 연마하면서 복합레진 시편위에 위치시켜 동일한 방법으로 색상을 측정하였다. 모든 시편에서 $L^{\ast}$값과 $b^{\ast}$값은 배경색에 무관하게 치아시편의 두께가 두꺼워질수록 증가하는 양상을 보였으나(p < 0.05), $a^{\ast}$값은 배경색에 무관하게 두께에 따른 유의한 차이를 보이지 않았다.

지역아동센터 교사의 칫솔질 지도여부에 따른 아동과 교사의 구강보건행태 (The Oral Health Behaviors for Children and Teachers by Teacher-Supervised Toothbrushing in Community Child Center)

  • 신선정;장정유;김창희
    • 치위생과학회지
    • /
    • 제12권6호
    • /
    • pp.572-582
    • /
    • 2012
  • 지역아동센터 아동의 구강건강증진을 위해 개인의 행동 변화, 물리적 환경의 변화와 더불어 교사의 역할과 책임을 고찰하고자 지역아동센터 내에서 양치시설이 설치되어 있는 센터와 그렇지 않는 센터와의 구강건강증진에 대한 견해를 비교한 결과는 다음과 같다. 1. 일상적으로 교사가 칫솔질을 지도하는 센터의 아동들이 급식 후 칫솔질 실천율이 높았고, 간식 후 칫솔질 칫솔질 또는 물양치를 실천하는 비율이 높았다(p<0.05). 또한 이를 교사가 지도하는 빈도는 일상적으로 칫솔질을 지도하는 센터의 경우 '항상 또는 자주 지도'하는 비율이 높았고, 더불어 치약의 사용량과 칫솔관리 및 보관 등 구체적인 구강건강관리 내용을 지도비율이 높았으며, 이는 일상적으로 칫솔질을 지도하지 않는 센터와 통계적으로 유의한 차이가 있었다(p<0.001). 2. 불량한 칫솔을 교체하지 못하는 아동의 비율이 40.0% 이상인 지역아동센터가 전체의 24.4% 수준이었고, 그 사유로는 대부분 부모의 관심부족으로 나타났으며, 이는 칫솔질 지도여부 간에는 통계적으로 유의한 차이가 없었다(p>0.05). 3. 지역아동센터 교사의 구강건강관련 보건행동은 칫솔질 지도여부와는 상관없이 일 평균 간식은 1회 정도 제공하며, 간식의 종류는 우식성 식품과 비우식성 식품을 반반 정도 제공하고 있었다. 또한 아동의 착한 행동에 대한 보상으로 일상적 또는 때때로 단것을 제공하는 비율이 각각 47.0%, 52.3%로 나타났다(p>0.05). 4. 지역아동센터 교사의 칫솔질을 지도여부와 상관없이 대부분의 교사들의 구강보건지식 수순은 높았고, 본인들의 칫솔질 실천도 일 평균 3회 정도로 높았으며, 회전법으로 칫솔질을 실천하고 있었다(p>0.05). 5. 지역아동센터 아동의 구강건강증진을 위한 환경 개선에 대한 견해는 칫솔질 지도여부와 상관없이 지역아동센터 아동의 건강증진 주체를 아동복지교사로 생각하고 있었으며(73.4%), 칫솔질 및 손씻기 용의 세면대 개선(77.2%)을 요구하였고, 대부분의 보건 프로그램을 건강증진 프로그램으로 생각하고 있으며, 그 중 양치와 손씻기 등 개인위생에 관한 내용의 요구도(100.0%)가 높았다. 뿐만 아니라 치과검진과 치과치료 연계(100.0%) 등 직접적인 치과의료 서비스제공의 요구도도 높았다. 이상의 결과로 지역아동센터 아동의 구강건강을 증진시키기 위해서는 아동의 올바른 구강건강관리 행동을 지속적으로 유지하기 위한 교사들의 적극적인 참여와 지도가 매우 중요하며, 이를 위해서 지역사회 내에서 교사를 위한 교육프로그램 마련뿐 아니라 사회적 지원이 함께 이루어져야 할 것으로 사료된다.