• 제목/요약/키워드: diameter of hole

검색결과 759건 처리시간 0.029초

Simulation of the effect of inclusions length and angle on the failure behavior of concrete structure under 3D compressive test: Experimental test and numerical simulation

  • Mohammad Saeed, Amini;Vahab, Sarfarazi;Kaveh, Asgari;Xiao, Wang;Mojtaba Moheb, Hoori
    • Steel and Composite Structures
    • /
    • 제46권1호
    • /
    • pp.53-73
    • /
    • 2023
  • Man-made structure materials like concrete usually contain inclusions. These inclusions affect the mechanical properties of concrete. In this investigation, the influence of inclusion length and inclination angle on three-dimensional failure mechanism of concrete under uniaxial compression were performed using experimental test and numerical simulation. Approach of acoustic emission were jointly used to analyze the damage and fracture process. Besides, by combining the stress-strain behavior, quantitative determination of the thresholds of crack stress were done. concrete specimens with dimensions of 120 mm × 150 mm × 100 mm were provided. One and two holes filled by gypsum are incorporated in concrete samples. To build the inclusion, firstly cylinder steel tube was pre-inserting into the concrete and removing them after the initial hardening of the specimen. Secondly, the gypsum was poured into the holes. Tensile strengths of concrete and gypsum were 2.45 MPa and 1.5 MPa, respectively. The angle bertween inclusions and axial loadind ary from 0 to 90 with increases of 30. The length of inclusion vary from 25 mm to 100 mm with increases of 25 mm. Diameter of the hole was 20 mm. Entirely 20 various models were examined under uniaxial test. Simultaneous with experimental tests, numerical simulation (Particle flow code in two dimension) were carried out on the numerical models containing the inclusions. The numerical model were calibrated firstly by experimental outputs and then failure behavior of models containing inclusions have been investigated. The angle bertween inclusions and axial loadind vary from 0 to 90 with increases of 15. The length of inclusion vary from 25 mm to 100 mm with increases of 25 mm. Entirely 32 various models were examined under uniaxial test. Loading rate was 0.05 mm/sec. The results indicated that when inclusion has occupied 100% of sample thickness, two tensile cracks originated from boundaries of sample and spread parallel to the loading direction until being integrated together. When inclusion has occupied 75% of sample thickness, four tensile cracks originated from boundaries of sample and spread parallel to the loading direction until being integrated together. When inclusions have occupied 50% and 25% of sample thickness, four tensile cracks originated from boundaries of sample and spread parallel to the loading direction until being integrated together. Also the inclusion was failed by one tensile crack. The compressive strength of samples decease with the decreases of the inclusions length, and inclusion angle had some effects on that. Failure of concrete is mostly due to the tensile crack. The behavior of crack, was affected by the inclusion length and inclusion number.

Differential Diagnosis of Chemical-induced Hepatobiliary Toxicities Using a New Hepatobiliary Imaging Agent in Mice

  • Ryu, Chong-Kun;Pie, Jae-Eun;Choe, Jae-Gol;Cheon, Joon;Sohn, Jeong-Won;Jurgen Seidel;David S. Paik;Michael V. Green;Chang H. Paik;Kim, Meyoung-Kon
    • 한국환경성돌연변이발암원학회지
    • /
    • 제21권1호
    • /
    • pp.1-8
    • /
    • 2001
  • We have synthesized $^{99m}$Tc-mercaptoacetyltriglycine (MAG3)-biocytin as a new imaging agent for hepatobiliary scintigraphy. The aim of this study was to evaluate the usefulness of $^{99m}$Tc-MAG3-biocytin scintigraphy in differentiating carbon tetrachloride ( $CCl_4$)-induced hepatotoxicity from $\alpha$-naphthylisothiocyanate (ANIT)-induced cholestasis in mice, which reflecting the differential diagnosis of neonatal jaundice caused by neonatal hepatitis from congenital biliary atresia in humans. Methods: Balb/c mice (female, 20 g, n=4-6) were pretreated with $CCl_4$(0.5 or $1.0m\ell$/kg) and ANIT ($150 or 300 m\ell$/kg) 18 h before scintigraphy. Biochemical and histopathological examinations showed a pattern of typical acute hepatitis (increase of transaminases and hepatocellular necnsis) in $CCl_4$-treated mice and cholestasis (increase of alkaline phosphatase and ${\gamma}$-glutamyltransferase, and biliary hyperplasia) in ANIT-treated mice, respectively, Mice were fasted at least 4 hr prior to the intravenous injection of $^{99m}$Tc-MAG3-biocytin (18.5 MBq/20$\mu\textrm{g}$) in 2% human serum albumin in saline. Scintigraphy was performed with a ${\gamma}$-camera equipped with a 1-mm diameter pin-hole collimator for 30 min and images were acquired every 15 s. We compared the values of physical parameters, such as peak liver/heart ratio ($${\gamma}$_{max}$) and peak ratio time ($t_{max}$) far $^{99m}$Tc-MAG3-biocytin scintigraphy. Results: Scintigraphic parameters of the $CCl_4$-pretreated (0.5 $m\ell$/kg) group showed a 81.9% decrease of r$_{max}$, and 42.2% decrease of $t_{max}$, whereas the ANIT-pretreated ( $150m\ell$/kg) group showed a 53% decrease of $r_{max}$, and 2.36-fold increase of $t_{max}$, (P<0.05). These results demonstrate that the decrease of $r_{max}$ and the shortening of $t_{max}$ are characteristic features for hepatotoxicity, in contrast to the increase of $t_{max}$ and decrease of $r_{max}$ for biliary hyperplasia. Conclusion: $^{99m}$Tc-MAG3-biocytin hepatobiliary scintigraphy can distinguish hepatitis from cholestasis in mice model and may be similarly useful in humans which differentiating the cause of neonatal jaundice in clinical study.cal study.cal study.cal study.

  • PDF

임플란트 고정체의 platform의 크기에 따른 유한요소법적 응력분석 (FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO PLATFORM WIDTH OF FIXTURE)

  • 정경민;정재헌;정승미
    • 대한치과보철학회지
    • /
    • 제41권5호
    • /
    • pp.674-688
    • /
    • 2003
  • Statement of Problem : With increasing demand of the implant-supported prosthesis, it is advantageous to use the different platform width of the fixture according to bone quantity and quality of the patients. Purpose : The purpose of this study was to assess the loading distributing characteristics of two implant designs according to each platform width of fixture, under vertical and inclined loading using finite element analysis. Material and method : The two kinds of finite element models were designed according to each platform width of future (4.1mm restorative component x 11.5mm length, 5.0mm wide-diameter restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction, 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction and 200N at the buccal cusp in a 300 transverse direction individually Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. Results : The stresses were concentrated mainly at the cortex in both vertical and oblique load ing but the stresses in the cancellous bone were low in both vertical and oblique loading. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading. Increasing the platform width of the implant fixture decreased the stress in the supporting bone, future and abutment screw. Increased the platform width of fixture decreased the stress in the crown and platform. Conclusion : Conclusively, this investigation provides evidence that the platform width of the implant fixture directly affects periimplant stress. By increasing the platform width of the implant fixture, it showed tendency to decreased the supporting bone, future and screw. But, further clinical studies are necessary to determine the ideal protocol for the successful placement of wide platform implants.

Adaptability Test on Low Organic Soil and Selection of Varieties of Soybean Cultivars

  • Sung-Hyun Yun;Ju-young Choi;Young-Hwan Ju;Min-Young Park;Soo-Jeong Kwon ;Probir Kumar Mittra;Sang-Do Lee ;Tae-Young Hwang ;Sun-Hee Woo
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2022년도 추계학술대회
    • /
    • pp.78-78
    • /
    • 2022
  • Food productivity in North Korea is about 50% lower than in South Korea. In order to increase the productivity of major crops, it is necessary to develop early maturing, disease resistance, and high-yielding varieties and apply them early. Since the late 1990s, North Korea has been actively developing potatoes, rice and com as major food crops, and soybeans are considered important as a protein-supplying crop. Domestic cultivated varieties, which are expected to be most adaptable eco-climatologically, are mainly selected from soil with high nutrient soil. It is necessary to test separately for adaptability in low organic soil. So it is very necessary to apply technology to improve soil improvement through rotational crop selection in the middle and long-term. Therefore, this study was conducted to test the adaptability to low organic soils of domestic cultivars and to select varieties. In 2021 there are twenty two (22) varieties of soybeans were grown in low organic soil at the field of Chungbuk National University. This year twenty two (22) varieties of soybeans were also grown in low organic soil at the field of Chungbuk National University. Sowing was done on June 10, the planting distance was 70cm × 15cm, after opening the cotyledons fully, the soybeans were thinned and leaving two plants per hole. In addition, various types of growth characteristics and quantitative components were investigated to evaluate the adaptability to low organic soil of domestic varieties. This study was conducted to investigate the growth characteristics and quantitative components of soybean varieties grown in low organic soil. The flowering period of 22 varieties of soybeans was about 14 days from July 22 to August 4. The flowers of the beans were white, purple, light purple and the pubescence color was gray and brown where most of them were gray. The highest plant height was up to 130.4 cm and lowest was 20.3 cm, highest stem length was up to 119.5 cm and lowest was 15.3 cm. Highest first pod height (FPH) was up to 34.0 cm and lowest was 3.0 cm. Highest stem diameter was up to 15.76mm and lowest was 1.76 mm. Number of main stem nodes was up to 19 and at least 1. Number of branch was up to 10 and at least 0. The number of pod per plant was up to 121. Bacterial pustule has been spread in soybean field.

  • PDF

악정형력 적용을 위한 골내 고정원으로서 미니플레이트 형상의 영향: 3차원 유한요소법적 연구 (INFLUENCE OF MINIPLATE SHAPES AS SKELETAL ANCHORAGE FOR APPLICATION OF ORTHOPEDIC FORCE: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS)

  • 이남기;백승학;최동순;박영욱;김지혁;차봉근
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권4호
    • /
    • pp.345-352
    • /
    • 2008
  • Purpose: This study was performed to evaluate the stress distribution in the bone and the displacement distribution of the miniscrew under orthopedic force with two different types of miniplate design as skeletal anchorage for orthopedic treatment. Materials and methods: Finite element models were made for 6-hole miniplate (0.8mm in thickness), which were designed in two different shapes-one is curvilinear shaped (C plate, Jeil Medical Co., Korea) and another, Y shaped (Y plate), fixed with 3 pieces of miniscrew 2mm-diameter and 6mm-long respectively. A traction force of 4 N was applied in $0^{\circ}$, $30^{\circ}$ and $60^{\circ}$ to imaginary axis connecting two unfixed distalmost holes of the miniplate. Results: The maximum von Mises stress in the bone was much greater in the cortical portion rather than in the cancellous portion. C plate showed greater maximum von Mises stress in the cortical bone than Y plate. The maximum displacement of the miniscrew was greater in C plate than Y plate. The more increased the angle of the applied orthopedic force, the greater maximum von Mises stress in the bone and maximum displacement of the miniscrew. It was observed that in C plate, the von Mises stress in the bone and displacement of the miniscrew were distributed around the distalmost screw-fixed area. Conclusions: The results suggest that Y plate should have the advantage over C plate and in the placement of the miniplate, its imaginary axis should be placed as parallel as possible to the direction of orthopedic force to obtain its primary stability.

황철석으로 조성된 성토구조체의 중화제 주입을 위한 최적 방안 제안 (Optimal Method for Injection of Neutralizer into Embankment Structure Composed of Pyrite Rocks)

  • 송영석;윤중만
    • 한국지반신소재학회논문집
    • /
    • 제22권4호
    • /
    • pp.73-82
    • /
    • 2023
  • 본 연구에서는 황철석 암버럭으로 시공된 성토체를 대상으로 산성배수 발생을 억제하기 위하여 중화제를 주입할 경우 최적의 주입방안을 제시하고자 한다. 성토체 내에 중화제 주입으로 인한 침투효과를 수치해석으로 검토하기 위하여 유한요소해석을 수행하였다. 수치해석을 위하여 중화제 주입관의 직경을 50mm로 선정하고 주입관의 간격을 1-4m, 주입압을 100-220kPa로 변화시키면서 침투해석을 수행하였다. 해석결과에 따르면 중화제의 주입관 간격 1.0m 및 주입압 130kPa인 경우와 주입관 간격 2.0m 및 주입압 160kPa인 경우가 상대적으로 낮은 주입압에서 성토체 전체의 포화 도달시간이 빠른 것으로 나타났다. 그리고, 성토체 전체의 포화를 위한 중화제 주입관의 간격은 3m인 경우 130kPa에서 190kPa까지 다양한 주입압을 적용할 수 있으며, 성토체의 포화 도달시간은 주입압에 상관없이 유사한 것으로 나타났다. 따라서 경제성을 고려한 최적의 중화제 주입조건으로 주입관의 간격은 3.0m, 주입압은 130kPa로 선정하였다.

수산화칼슐과 글라스아이오노머 시맨트가 치수내 leukotriene B4와 C4의 농도에 미치는 영향에 관한 연구 (EFFECT OF CALCIUM HYDROXIDE AND GLASS IONOMER CEMENT ON LEUKOTRIENE B4 AND C4 LEVELS IN EXPERIMENTALLY INFLAMED RAT DENTAL PULP)

  • 박계양;임성삼
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.451-469
    • /
    • 1996
  • The purpose of this study was to investigate the effect of calcium hydroxide and glass ionomer cement fillings on the levels of $LTB_4$ and $LTC_4$ in experimentally inflamed rat dental pulp. The dental pulp in the mandibular incisor of wistar rat was irritated by cutting a 5mm deep hole in the dentin with a twist drill bur of 0.5mm diameter, without cooling. The cavities were filled with calcium hydroxide(light-cured) and glass ionomer cement(light cured). The untreated pulp served as control tissue specimen. After cavity preparations, the rat with or without various treatment were sacrificed in various time by decapitation. The dental pulp tissue were carefully removed and the concentrations of $LTB_4$ and $LTC_4$ were determined by radioimmunoassay. And pulps were examined histologically to observe inflammatory feature. The result were obtained as follows : 1. The inflammatory features of pulps were observed microscopically in all experimental groups. And degree of inflammation was decreased with time. 2. The concentrations of $LTB_4$ and $LTC_4$ for all experimental groups were significantly higher than those for control group 6 hours after cavity preparation(p<0.05). 3. The group filled with calcium hydroxide was the lowest, and the group filled with glass ionomer cement, the group of irritation in that order showed increased concentrations of $LTB_4$ and $LTC_4$ 6 hours after cavity preparation. In the concentrations of $LTB_4$, significant differences among 3 groups were noted(p<0.05). 4. The group filled with calcium hydroxide was the lowest, and the group filled with glass ionomer cement, the group of irritation in that order showed increased concentrations of $LTB_4$ and $LTC_4$ 24 hours after cavity preparation. And there were statistically significant difference in concentrations of $LTB_4$ between the group of irritation and the group filled with calcium hydroxide(p<0.05). 5. The group filled with calcium hydroxide was the lowest, and the group filled with glass ionomer cement, the group of irritation in that order showed increased concentrations of $LTB_4$ and $LTC_4$ 48 hours after cavity preparation. But no statistically difference was found (p>0.05). 6. The concentrations of $LTB_4$ and $LTC_4$ in all experimental groups were highest level at 6 hour after experiment and decreased as time progresses(correlation coefficient>0.8).

  • PDF

개에서 치아 임플란트 식립후 치조골의 신티그라피 평가 (Scintigraphic Evaluation of Alveolar Bone Following Dental Implantation in Dogs)

  • 김중현;이재영;김명환;이원국;강성수;최석화
    • 대한수의학회지
    • /
    • 제43권2호
    • /
    • pp.289-294
    • /
    • 2003
  • This study aimed to determine of osseointegration following dental implantation in the dog mandible using bone scintigraphy. Five mongrel dogs, weighing approximately 8.5 kg and averaging 1.8 years of age, without active periodontal disease were used. During the entire study period, all dogs were fed a soft commercial diet and water ad libitum to minimize functional loading of the implant. Titanium alloy implant systems 10 mm in length and 4 mm in diameter were chosen for insertion. Twelve weeks prior to implantation, the second and third left mandibular premolars in each dog were extracted for the dental implant insertion. Before the dental implantation procedures and 0, 4, 8, and 12 weeks after the insertions, clinical observation, radiography and bone scintigraphy were conducted. The scintigraphy was obtained using a large field of view gamma camera equipped with a paralled-hole, low-energy collimator about 3 hours after intravenous injection of Tc-99m-MDP (8 mCi/dog) to the dogs. There were not inflammation sign after insertion of dental implants on the mandible in dogs. Implants were slightly movable at the first and fourth weeks, and there was no mobility after 8 weeks. Twelve weeks after dental implantation, the bone uptake scintigraphy of peri-implant bone was similar to that of normal alveolar bone, indicating that peri-implant bone was completely regenerated by new bone. In conclusion, we recommend stable implant fixation with alveolar bone for the accurate and safe repair of teeth loot due to decacy, trauma or peridontal disease. Titanium alloy implants were optimal due to their biocompatibility.

Electrical Characterization of Ultrathin Film Electrolytes for Micro-SOFCs

  • Shin, Eui-Chol;Ahn, Pyung-An;Jo, Jung-Mo;Noh, Ho-Sung;Hwang, Jaeyeon;Lee, Jong-Ho;Son, Ji-Won;Lee, Jong-Sook
    • 한국세라믹학회지
    • /
    • 제49권5호
    • /
    • pp.404-411
    • /
    • 2012
  • The reliability of solid oxide fuel cells (SOFCs) particularly depends on the high quality of solid oxide electrolytes. The application of thinner electrolytes and multi electrolyte layers requires a more reliable characterization method. Most of the investigations on thin film solid electrolytes have been made for the parallel transport along the interface, which is not however directly related to the fuel cell performance of those electrolytes. In this work an array of ion-blocking metallic Ti/Au microelectrodes with about a $160{\mu}m$ diameter was applied on top of an ultrathin ($1{\mu}m$) yttria-stabilized-zirconia/gadolinium-doped-ceria (YSZ/GDC) heterolayer solid electrolyte in a micro-SOFC prepared by PLD as well as an 8-${\mu}m$ thick YSZ layer by screen printing, to study the transport characteristics in the perpendicular direction relevant for fuel cell operation. While the capacitance variation in the electrode area supported the working principle of the measurement technique, other local variations could be related to the quality of the electrolyte layers and deposited electrode points. While the small electrode size and low temperature measurements increaseed the electrolyte resistances enough for the reliable estimation, the impedance spectra appeared to consist of only a large electrode polarization. Modulus representation distinguished two high frequency responses with resistance magnitude differing by orders of magnitude, which can be ascribed to the gadolinium-doped ceria buffer electrolyte layer with a 200 nm thickness and yttria-stabilized zirconia layer of about $1{\mu}m$. The major impedance response was attributed to the resistance due to electron hole conduction in GDC due to the ion-blocking top electrodes with activation energy of 0.7 eV. The respective conductivity values were obtained by model analysis using empirical Havriliak-Negami elements and by temperature adjustments with respect to the conductivity of the YSZ layers.

IV형의 골질로 재생된 골내에 식립된 원통형 임플란트의 유한요소법적 연구 (FINITE ELEMENT ANALYSIS OF CYLINDER TYPE IMPLANT PLACED INTO REGENERATED BONE WITH TYPE IV BONE QUALITY)

  • 김병옥;홍국선;김수관
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권4호
    • /
    • pp.331-338
    • /
    • 2004
  • Stress transfer to the surrounding tissues is one of the factors involved in the design of dental implants. Unfortunately, insufficient data are available for stress transfer within the regenerated bone surrounding dental implants. The purpose of this study was to investigate the concentration of stresses within the regenerated bone surrounding the implant using three-dimensional finite element stress analysis method. Stress magnitude and contours within the regenerated bone were calculated. The $3.75{\times}10-mm$ implant (3i, USA) was used for this study and was assumed to be 100% osseointegrated, and was placed in mandibular bone and restored with a cast gold crown. Using ANSYS software revision 6.0, a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The present study used a fine grid model incorporating elements between 165,148 and 253,604 and nodal points between 31,616 and 48,877. This study was simulated loads of 200N at the central fossa (A), at the outside point of the central fossa with resin filling into screw hole (B), and at the buccal cusp (C), in a vertical and $30^{\circ}$ lateral loading, respectively. The results were as follows; 1. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were increased from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, concentrated on the top of the cylindrical collar loading point B and C in vertical loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were increase from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in vertical loading. 2. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were decreased from loading point A to C in lateral loading. Stresses according to the depth of regenerated bone were concentrated on the top of the cylindrical collar in loading point A and B, distributed along the implant evenly in loading point C in lateral loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were decreased from loading point A to C in lateral loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in lateral loading. In summary, these data indicate that both bone quality surrounding the regenerated bone adjacent to implant fixture and load direction applied on the prosthesis could influence concentration of stress within the regenerated bone surrounding the cylindrical type implant fixture.