Chong Kun Cheon;Yong Beom Shin;Soo-Yeon Kim;Go Hun Seo;Hane Lee;Changwon Keum;Seung Hwan Oh
Journal of Genetic Medicine
/
v.19
no.2
/
pp.76-84
/
2022
Purpose: Whole-exome sequencing (WES) has been a useful tool for novel gene discovery of various disease categories, further increasing the diagnostic yield. This study aimed to investigate the clinical utility of WES prospectively in undiagnosed genetic diseases. Materials and Methods: WES tests were performed on 110 patients (age range, 0-28 years) with suspected rare genetic diseases. WES tests were performed at a single reference laboratory and the variants reported were reviewed by clinical geneticists, pediatricians, neurologists, and laboratory physicians. Results: The patients' symptoms varied with abnormalities in the head or neck, including facial dysmorphism, being the most common, identified in 85.4% of patients, followed by abnormalities in the nervous system (83.6%). The average number of systems manifesting phenotypic abnormalities per patient was 3.9±1.7. The age at presentation was 2.1±2.7 years old (range, 0-15 years), and the age at WES testing was 6.7±5.3 years (range, 0-28 years). In total, WES test reported 100 pathogenic/likely pathogenic variants or variants of uncertain significance for 79 out of 110 probands (71.8%). Of the 79 patients with positive or inconclusive calls, 55 (50.0%) patients were determined to have good genotype-phenotype correlations after careful review. Further clinical reassessment and family member testing determined 45 (40.9%) patients to have been identified with a molecular diagnosis. Conclusion: This study showed a 40.9% diagnostic yield for WES test for a heterogeneous patient cohort with suspected rare genetic diseases. WES could be the feasible genetic test modality to overcome the diversity and complexity of rare disease diagnostics.
Radiopharmaceuticals are drugs that contain radioisotopes and are used in the diagnosis, treatment, or investigation of diseases. Radiopharmaceuticals must be manufactured in compliance with good manufacturing practice regulations and subjected to quality control before they are administered to patients to ensure the safety of the drug. Radiopharmaceuticals for administration to humans need to be sterile and pyrogen-free. Hence, sterility tests and membrane filter integrity tests are carried out to confirm the asepticity of the finished drug product, and a bacterial endotoxin test conducted to assess contamination, if any, by pyrogens. The physical appearance and the absence of foreign insoluble substances should be confirmed by a visual inspection. The chemical purity, residual solvents, and pH should be evaluated because residual by-products and impurities in the finished product can be harmful to patients. The half-life, radiochemical purity, radionuclidic purity, and strength need to be assessed by analyzing the radiation emitted from radiopharmaceuticals to verify that the radioisotope contents are properly labeled on pharmaceuticals. Radiopharmaceuticals always carry the risk of radiation exposure. Therefore, the time taken for quality control tests should be minimized and care should be taken to prevent radiation exposure during handling. This review discusses the quality control procedures and acceptance criteria for a diagnostic radiopharmaceutical.
Purpose: The purpose of this study was to establish optimal imaging acquisition conditions for the GE $Advance^{TM}$ PET imaging system by performing the acceptance tests designed by National Electrical Manufacturers Association (NEMA) protocol and General Electric Medical Systems (GEMS) test procedures. Materials and Methods: Performance tests were carried out with $^{18}FDG$ radioactivity source and phantoms by using a standard acquisition mode. Transaxial resolution and scatter traction tests were performed with a line source and axial resolution with a point source, respectively. A cylindrical phantom made of polymethylmethacrylate (PMMA) was used to measure sensitivity, count rate losses and randoms, uniformity correction, and attenuation inserts were added to measure remaining tests. The test results were acquired in a diagnostic acquisition mode and analyzed mainly on high sensitivity mode. Results: Transaxial resolution and axial resolution were measured as average of 4.65 mm and 3.98 mm at 0 cm, and 6.02 mm and 6.71 mm at 20 cm on high sensitivity mode, respectively. Average scatter fraction was 9.87%, and sensitivity was $225.8kcps/{\mu}Ci/cc$ of trues. Activity at 50% deadtime was $4.6{\mu}Ci/cc$, and the error of count rate correction at that activity was from 1.49% to 3.83%. Average nonuniformity for total slice w3s 8.37%. The accuracy of scatter correction was -0.95%. The accuracies of attenuation correction were 5.68% for air, 0.04% for water and -6.51% for polytetrafluoroethylene (PTFE). Conclusion: The results satisfied most acceptance criteria, indicating that the GE $Advance^{TM}$ PET system can be optimally used for clinical applications.
Journal of The Korean Society of Clinical Toxicology
/
v.19
no.1
/
pp.24-30
/
2021
Purpose: In Korea, it is predicted that the proportion of drug abusers among patients visiting the emergency room will soon increase. Several emergency medical institutions in Korea are conducting field urine screening tests for poisoning. In this study, we investigated the characteristics and usefulness of urine toxicology screening tests. Methods: The medical records of patients with positive results for tetrahydrocannabinol and methamphetamine from urine toxicology screening tests at a tertiary university hospital from August 2016 to August 2019 were reviewed retrospectively. The subjects were classified into positive and false-positive groups, and their clinical characteristics were compared and analyzed. Results: Of the 2,026 patients surveyed, 823 patients (40.6%) tested positive for one or more drugs. Among them, 12 cases (0.6%) were positive for methamphetamine and 40 cases (2.0%) were positive for tetrahydrocannabinol. The positive and the false-positive rates for methamphetamine were 66.7% and 33.3%, respectively. The positive and the false-positive rates for tetrahydrocannabinol were 2.5% and 97.5%, respectively. Conclusion: Methamphetamine showed a relatively low false-positive rate in our study. Therefore, this test seemed to assist in diagnosing methamphetamine poisoning when considered together with the present illness and physical examination results. On the other hand, the high false-positive rate for tetrahydrocannabinol tests indicates that this test was unlikely to assist in diagnosing tetrahydrocannabinol poisoning. However, considering the growing trend of illegal drug abusers in Korea, it may still be useful as a diagnostic tool for identifying drug users.
Journal of Korea Entertainment Industry Association
/
v.15
no.1
/
pp.181-189
/
2021
The purpose of this study is to investigate the relationship between "Mental Status and Dementia Tests" and "predictive diagnosis of severity of dementia". This is a descriptive research, analyze the data collected from Alzheimer's patients and identify which "Mental Status and Dementia Tests" has the most impact to determine the severity of dementia. For this study, Alzheimer's patient's CDR, MMSE-K, SGDS, NPI-Q, BADL and IADL were collected and analyzed. This study will provide a predictive factor to determine the severity of dementia when "Mental Status and Dementia Testss" are being used and also to provide the right treatment. For this study, a total of 617 cases of data from Alzheimer's patients were collected and analyzed with SPSS Statistics. In addition, effective "Mental Status and Dementia Tests" for evaluating the severity of dementia were CDR, ADL, MMSE-K, and SGDS whereas NPI-Q and IADL. Based on the findings of the study, it was recommended to implement more efficient diagnostic method by utilizing a standardized "Mental Status and Dementia Tests".
Background : Transbronchial lung biopsy (TBLB) is a relatively simple and convenient procedure to obtain lung tissue from a patient with diffuse or localized lesion on chest radiographs, whose disease cannot be diagnosed through routine tests. The authors tried to evaluate the diagnostic value of TBLB, especially, the concordance between CT scan and TBLB with respect to the location of the lesion and diagnostic yield according to tumor-bronchus relationship. Method : We reviewed the medical records, plain chest films, and chest CT scans of 278 patients who underwent TBLB at Kyungpook National University Hospital between January 1996 and June 1998. Results : One hundred and sixteen (41.7 %) patients were diagnosed by TBLB. Diagnostic yield of TBLB of malignant tumors tended to be higher than that of benign diseases (64.7% versus 53.9%, p=0.09). Of primary lung cancers, TBLB was more diagnostic in adenocarcinoma and small-cell carcinoma than other cell types (p<0.01) and, of benign diseases, more diagnostic in tuberculosis than in non-tuberculous diseases (p<0.05). There was no significant difference in the diagnostic rate according to the location of the tumor. The diagnostic rate tended to increase with the size of tumor (p=0.06). The diagnootic rate of TBLB did not differ according to the pattern of lesion in benign diseases. However, in malignant diseases TBLB was more diagnostic in diffuse/multiple nodular lesions than in localized lesions(p<0.05). According to the tumor-bronchus relationship, TBLB was more diagnootic in type I/II groups than in other types. CT scan and TBLB showed a strong correlation with respect to the localization of the lesion (r=0.994, p<0.01). Conclusion : The above results show that TBLB is useful in the diagnosis of lung disease. CT scan and TBLB showed a strong correlation in determining the location of the lesion. Diagnostic yield of TBLB is higher in lesions with 'bronchus sign' (type I and II). TBLB and other diagnootic methods such as transthoracic needle aspiration are expected to complement one another in the diagnosis of lung diseases.
Pulmonary carcinosarcon!as are rare malignant tumors consisting of an admixture of epithelial and mas- enchymal elements of the type ordinarily seen in malignancies of adults. Compared with all pulmonary neoplasms it occurs with a frequency of 0.3% and has a strong association with smoking. Carcinosarcomas be divided into two clinicopathologic groups based on the locution of the lung: a solid parenchymal type and a central or endobronchial lesion Noninvasive diagnostic tests have a rather low yield in detecting carcinosarcoma. The most frequent metastatic sites are hilar and mediastinal Lymph nodes. Surgical resection is both diagnostic and the initial treatment. The prognosis is poor and average postoperative survival is 9 months. We report one case of pulmonary carcinosarcoma demonstrated by immunohlstochemical staining in a 61 year old male patient with a review of literatures.
Subacute Ankle Sprain patients, 3 tests have been acknowledge for diagnostic precision and thus most commonly used to test their soft tissues, muscles, and ligaments: ankle stress-valgus test, anterior-draw test, and MRI scan. Although not much different from the rest two in its diagnostic value, MRI costs patients some money and time. Also, we have reached the conclusion through an experiment with a group of patients in a certain hospital that the rest two methods is as efficient and useful as MRI in diagnosing ankle joint patients.
Food allergies affect 7~8% of infants and young children, and their prevalence appears to have increased in recent years. Food allergy refers to an abnormal immunological reaction to a specific food. These reactions can be recurrent each time the food is ingested. Food allergy manifests itself with a wide spectrum of clinical characteristics including IgE-mediated diseases as immediate reactions, non-IgE-mediated disorders as delayed reactions, and mixed hypersensitivities. As a consequence, the clinical picture of a food allergy is pleomorphic. A well-designed oral food challenge is the most reliable diagnostic test for infants and young children whose clinical history and physical examination point towards a specific food allergy. Food specific IgE antibody tests (RAST, MAST, skin prick test, Uni-CAP, etc) are an alternative tool to determine oral food challenge for IgE-mediated disorders, but not for non-IgE-mediated allergies. Moreover, parents often impose their children on unnecessary diets without adequate medical supervision. These inappropriate dietary restrictions may cause nutritional deficiencies. This review aims to introduce clinical perspectives of food allergy in infants and young children and to orient clinicians towards different strains of diagnostic approaches, dietary management, and follow-up assessment of tolerance development.
Journal of The Korean Society of Clinical Toxicology
/
v.2
no.2
/
pp.147-150
/
2004
Hydrogen sulfide is a colorless, and malodorous 'rotten eggs' gas that results from the decay of organic material. It is a byproduct of industry and agriculture. The mechanism of its toxicity is primarily related to inhibition of oxidative phosphorylation, which causes a decrease in available cellular energy. Because there is no rapid method of detection that is of clinical diagnostic use, management decisions must be made based on history, clinical presentation, and diagnostic tests that imply hydrogen sulfide's presence. Although there is some anecdotal evidence to suggest that the early use of hyperbaric oxygen is beneficial, supportive care remains the mainstay of therapy. We describe an occupational exposure to hydrogen sulfide gas in 51-year-old man. While cleaning the sewage of pigs. he became unconscious. When he arrived in the emergency department, he had irritability and confused mentality. The typical smell of rotten eggs on clothing and exhaled air were enough to be considered to be exposed to hydrogen sulfide. Hyperbaric oxygen therapy was performed. He had a recovery to normal function.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.