• Title/Summary/Keyword: diagnostic tests

Search Result 807, Processing Time 0.025 seconds

Pathophysiology of orthostatic tremor: a multiple case study (길입성 진전의 병태생리: 다증 증례 연구)

  • Seo, Man-Wook;Lee, Kwang-Woo
    • Annals of Clinical Neurophysiology
    • /
    • v.4 no.1
    • /
    • pp.44-50
    • /
    • 2002
  • Introduction : Orthostatic tremor develops in the legs while standing up with no weakness, pain or imbalance in the leg and the tremor is characteristically not observed when walking. However there have been some confusions about orthostatic tremor in several aspects. For the past ten years, we have observed 4 patients with orthostatic tremor. In each case tests were performed to investigate the following three important areas of inquiry about orthostatic tremor. Firstly, whether this disorder is an independent diagnostic entity or a variant of essential tremor. Secondly, whether the progress of this disorder is specifically related with standing posture. Lastly, the nature of the pathophysiologic mechanism behind the appearance of the tremor when standing after the lapse of a certain latent period and its disappearance upon the commencement of walking. Methods : Our 4 cases of orthostatic tremor were studied clinically, electrophysiologically, and pharmacologically. Electrophysiological tests included tremor spectrum test and electromyography. Results : We observed the presence of this tremor in several other tonic postures, as well as its absence, in a vertically lifted position from all our cases. Our cases registered a variable tremor frequency between 5 and 12 Hz according to the tremor spectrum test and EMG. Furthermore all our 4 cases demonstrated patterns of both synchronous EMG activity and alternating EMG activity at various times in homologous muscles of both legs. Orthostatic tremor was improved significantly with propranolol as well as clonazepam. Conclusions : From the results of our study we drew the following conclusions. It is probable that orthostatic tremor is simply a variant of essential tremor rather than being an independent diagnostic entity and that in most cases its development is specifically related with muscle contraction rather than merely with the act of standing. Furthermore we discovered a clue in the previously described neural control mechanism that the nuclear bag fibers in the muscle spindle have lag time of several seconds in their response to muscle strength and that their baseline does not reset fully in rapidly moving muscle. This neural control mechanism could offer sufficient explanation for the phenomena of tremor appearance when standing and disappearance when walking in orthostatic tremor.

  • PDF

DIAGNOSTIC EFFICACY OF MENTAL NERVE SEP(SOMATOSENSORY EVOKED POTENTIALS) FOR THE INJURED INFERIOR ALVEOLAR NERVE (하치조신경 손상시 턱끝신경 체성감각유발전위검사의 진단적 유용성에 관한 연구)

  • Jeong, Hyeon-Ju;Kim, Myung-Rae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.250-257
    • /
    • 2001
  • Sensory dysfunction following the injury of the inferior alveolar nerve requires objective examination to get a reproducible data and to provide necessary treatment. This study was designed to evaluate if the SEP(somatosensory evoked potentials) of the mental nerve can be used as an objective method for the diagnosis of nerve injury and sensory disturbances. The subjects were nineteen patients ($37.4{\pm}11.3$ years old) who had been suffered from sensory disturbance of the unilateral lower lip and mental region for over 6 months after the inferior alveolar nerve injuries confirmed by the microsurgical explorations. The clinical neurosensory tests as SLTD(static light touch discrimination), MDD(moving direction discrimination), 2PD(two point discrimination), PPN(pin prick nociception) and accompanied pain were preceded to electro-physiologic examinations as SEP. The score of sensory dysfunction (sum score of all sensory tests) ranged from 0 to 8 were compared to the latency differences of the mental nerve SEPs. The correlation between clinical sensory scores and SEPs were tested by Spearman nonparametric rank correlation analysis, the differences in SEP latency by Kruskal-Wallis test and the latency differences according to PPN and accompanied pain by Mann-Whitney U test. This study resulted that the difference of the latencies between normal side and affected side was $2.22{\pm}2.46$ msec and correlated significantly with the neurosensory dysfunction scores (p=0.0001). Conclusively, the somatosensory evoked potentials of the mental nerve can be a useful diagnostic method to evaluate the inferior alveolar nerve injuries and the change of sensory dysfunction to be reproduced as an objective assessment.

  • PDF

Acceptance Test and Quality Control of Radiotherapy Treatment Simulator (의료용 모의치료기의 품질관리에 관한 연구)

  • 신동호;박성용;신동오;최진호;김유현;권수일
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.90-97
    • /
    • 2002
  • The simulator which has a identical geometry with radiotherapy equipments, is a essential equipment to accomplish optimized radiotherapy plan through simulation by using diagnostic low energy X-ray. A Radiotherapy simulator has a combined technology from the therapeutic and diagnostic radiology and needs a periodical test for mechanical and optical properties, X-ray generator, image intensifier of simulator to keep the proper maintenance and radiation safety. Hence, tests were done and classified as i) mechanical and optical parameter for the gantry, collimator, and couch ii) key performance of the X-ray generator such as a kVp, mAs, and timer iii) performance of the image intensifier such as a resolution and contrast for three kinds of simulator, common use in clinic. The above result of tests will be applied to the acceptance test and periodical quality assurance procedure.

  • PDF

Analysis of Insulation Quality in Large Generator Stator Windings

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho;Kim, Byong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.384-390
    • /
    • 2011
  • To evaluate the condition of stator winding insulation in generators that have been operated for a long period of time, diagnostic tests were performed on the stator bars of a 500 MW, 22 kV generator under accelerated thermal and electrical aging procedures. The tests included measurements of AC current (${\Delta}I$), dissipation factor ($tan{\delta}$), partial discharge (PD) magnitude, and capacitance (C). In addition, the AC current test was performed on the stator winding of a 350 MW, 24 kV generator under operation to confirm insulation deterioration. The values of ${\Delta}I$, ${\Delta}tan{\delta}$, and PD magnitude in one stator bar indicated serious insulation deterioration. In another stator bar, the ${\Delta}I$ measurements showed that the insulation was in good condition, whereas the values of ${\Delta}tan{\delta}$ and PD magnitude indicated an incipient stage of insulation deterioration. Measurements of ${\Delta}I$ and PD magnitude in all three phases (A, B, C) of the remaining generator stator windings showed that they were in good condition, although the ${\Delta}tan{\delta}$ measurements suggested that the condition of the insulation should be monitored carefully. Overall analysis of the results suggested that the generator stator windings were in good condition. The patterns of PD magnitude in all three phases (A, B, C) were attributed to internal discharge.

Evaluation of Rapid Diagnostics for Plasmodium falciparum and P. vivax in Mae Sot Malaria Endemic Area, Thailand

  • Chaijaroenkul, Wanna;Wongchai, Thanee;Ruangweerayut, Ronnatrai;Na-Bangchang, Kesara
    • Parasites, Hosts and Diseases
    • /
    • v.49 no.1
    • /
    • pp.33-38
    • /
    • 2011
  • Prompt and accurate diagnosis of malaria is the key to prevent disease morbidity and mortality. This study was carried out to evaluate diagnostic performance of 3 commercial rapid detection tests (RDTs), i.e., Malaria Antigen Pf/Pan$^{TM}$, Malaria Ag-Pf$^{TM}$, and Malaria Ag-Pv$^{TM}$ tests, in comparison with the microscopic and PCR methods. A total of 460 blood samples microscopically positive for Plasmodium falciparum (211 samples), P. vivax (218), mixed with P. falciparum and P. vivax (30), or P. ovale (1), and 124 samples of healthy subjects or patients with other fever-related infections, were collected. The sensitivities of Malaria Ag-Pf$^{TM}$ and Malaria Antigen Pf/Pan$^{TM}$ compared with the microscopic method for P. falciparum or P. vivax detection were 97.6% and 99.0%, or 98.6% and 99.0%, respectively. The specificities of Malaria Ag-Pf$^{TM}$, Malaria Ag-Pv$^{TM}$, and Malaria Antigen Pf/Pan$^{TM}$ were 93.3%,98.8%, and 94.4%, respectively. The sensitivities of Malaria Ag-Pf$^{TM}$, Malaria Antigen Pf/Pan$^{TM}$, and microscopic method, when PCR was used as a reference method for P. falciparum or P. vivax detection were 91.8%, 100%, and 96.7%, or 91.9%,92.6%, and 97.3%, respectively. The specificities of Malaria Ag-Pf$^{TM}$, Malaria Ag-Pv$^{TM}$, Malaria Antigen Pf/Pan$^{TM}$, and microscopic method were 66.2%, 92.7%, 73.9%, and 78.2%, respectively. Results indicated that the diagnostic performances of all the commercial RDTs are satisfactory for application to malaria diagnosis.

Design and Implementation of Mobile ]Respiration Detection Diagnostic System using Ultrasound Sensing Method fficient Multicasting Environment (초음파 센싱 방식을 이용한 이동형 호흡량 측정 진단기의 설계 및 구현)

  • 김동학;김영길
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.509-515
    • /
    • 2004
  • Pulmonary function tests are widely used to diagnose and determine patients' therapy in clinic. And it was also applied in the research of the physiology and dynamics for lung disease. Among the pulmonary function tests, spirometry is the most easy and economic test. Spirometers are medical instruments that measure the instantaneous rate of volume flow of respired Bas. The mechanical spirometer was mostly used in the past. Up to the present, the most popular method of spirometer is the differential pressure technique with which change in the volume of flow are transferred to change in pressure. This kind of instrument suffers from several limitations, pressure drop, difficulty in maintenance and short period of calibration. Therefore, this study has begun to implement ultrasound spirometer, which is free of pressure loss and has wide range, focusing on the flow measurement technique and diagnostic algorithm.

Awareness, Nursing Needs, and Nursing Satisfaction on Conscious Sedation as a Pretreatment for Diagnostic Tests in the Guardians of Hospitalized Children (진단검사 전 처치로 실시하는 의식하 진정요법에 대한 환아 보호자의 인식도와 간호요구도, 간호만족도)

  • Seo, Mi Hee;Park, Soonjoo
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.573-581
    • /
    • 2021
  • This study aims to investigate the awareness, nursing needs, and nursing satisfaction of conscious sedation, and their relationships in the guardians of hospitalized children receiving conscious sedation. Data were collected from 120 guardians of children who were admitted to the pediatric ward of University Hospital C in D city from July 6 to October 6, 2016 and received conscious sedation as a pretreatment for diagnostic tests. The result showed that the guardians' awareness was relatively low (2.49±0.83) and nursing needs (4.53±0.40) was found to be significantly higher than nursing satisfaction (3.81±0.56)(p<.001). Awareness showed a significant positive correlation with nursing satisfaction (r=.18, p=.048) and there was a significant positive correlation between nursing needs and satisfaction (r=.20, p=.033). This result suggested that in order to improve the nursing satisfaction of the guardians, it is necessary to understand the awareness and nursing needs of the guardians on conscious sedation. In addition, the development of customized nursing intervention should be carried out based on the awareness and nursing needs.

Assessment of DRL for Computed Tomography in Local Hospital (지역병원에서의 전산화단층촬영 검사에 대한 DRL 평가)

  • Choi, Seok-Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.619-625
    • /
    • 2022
  • In the field of imaging medicine, computed tomography is one of the most common test methods and one of the most frequently used test methods in hospitals. However, it is accompanied by a very high radiation exposure compared to other test methods. In order to reduce exposure, CT scans should be performed only when absolutely necessary, and even if the tests are performed because they are absolutely necessary, a protocol that serves the purpose of the test and allows the test to be performed in a small dose should be used. In this study, we wanted to learn about the most up-to-date radiation dose usage information used by the region's leading general hospitals and develop a diagnostic reference level (DRL). In the experimental results, the Head CT and Abdomen CT tests showed that DLP was higher than the NRPB (U.K) and Korean DRL. The DLP values used by Chest CT were low for all 3 types of CT devices. The hospital found that efforts to reduce exposure should be made during CT examinations, and in particular, Head CT and Abdomen CT determined that efforts to reduce exposure were necessary.

A Review on Advanced Methodologies to Identify the Breast Cancer Classification using the Deep Learning Techniques

  • Bandaru, Satish Babu;Babu, G. Rama Mohan
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.4
    • /
    • pp.420-426
    • /
    • 2022
  • Breast cancer is among the cancers that may be healed as the disease diagnosed at early times before it is distributed through all the areas of the body. The Automatic Analysis of Diagnostic Tests (AAT) is an automated assistance for physicians that can deliver reliable findings to analyze the critically endangered diseases. Deep learning, a family of machine learning methods, has grown at an astonishing pace in recent years. It is used to search and render diagnoses in fields from banking to medicine to machine learning. We attempt to create a deep learning algorithm that can reliably diagnose the breast cancer in the mammogram. We want the algorithm to identify it as cancer, or this image is not cancer, allowing use of a full testing dataset of either strong clinical annotations in training data or the cancer status only, in which a few images of either cancers or noncancer were annotated. Even with this technique, the photographs would be annotated with the condition; an optional portion of the annotated image will then act as the mark. The final stage of the suggested system doesn't need any based labels to be accessible during model training. Furthermore, the results of the review process suggest that deep learning approaches have surpassed the extent of the level of state-of-of-the-the-the-art in tumor identification, feature extraction, and classification. in these three ways, the paper explains why learning algorithms were applied: train the network from scratch, transplanting certain deep learning concepts and constraints into a network, and (another way) reducing the amount of parameters in the trained nets, are two functions that help expand the scope of the networks. Researchers in economically developing countries have applied deep learning imaging devices to cancer detection; on the other hand, cancer chances have gone through the roof in Africa. Convolutional Neural Network (CNN) is a sort of deep learning that can aid you with a variety of other activities, such as speech recognition, image recognition, and classification. To accomplish this goal in this article, we will use CNN to categorize and identify breast cancer photographs from the available databases from the US Centers for Disease Control and Prevention.

Prospective evaluation of the clinical utility of whole-exome sequencing using buccal swabbing for undiagnosed rare diseases

  • Chong Kun Cheon;Yong Beom Shin;Soo-Yeon Kim;Go Hun Seo;Hane Lee;Changwon Keum;Seung Hwan Oh
    • Journal of Genetic Medicine
    • /
    • v.19 no.2
    • /
    • pp.76-84
    • /
    • 2022
  • Purpose: Whole-exome sequencing (WES) has been a useful tool for novel gene discovery of various disease categories, further increasing the diagnostic yield. This study aimed to investigate the clinical utility of WES prospectively in undiagnosed genetic diseases. Materials and Methods: WES tests were performed on 110 patients (age range, 0-28 years) with suspected rare genetic diseases. WES tests were performed at a single reference laboratory and the variants reported were reviewed by clinical geneticists, pediatricians, neurologists, and laboratory physicians. Results: The patients' symptoms varied with abnormalities in the head or neck, including facial dysmorphism, being the most common, identified in 85.4% of patients, followed by abnormalities in the nervous system (83.6%). The average number of systems manifesting phenotypic abnormalities per patient was 3.9±1.7. The age at presentation was 2.1±2.7 years old (range, 0-15 years), and the age at WES testing was 6.7±5.3 years (range, 0-28 years). In total, WES test reported 100 pathogenic/likely pathogenic variants or variants of uncertain significance for 79 out of 110 probands (71.8%). Of the 79 patients with positive or inconclusive calls, 55 (50.0%) patients were determined to have good genotype-phenotype correlations after careful review. Further clinical reassessment and family member testing determined 45 (40.9%) patients to have been identified with a molecular diagnosis. Conclusion: This study showed a 40.9% diagnostic yield for WES test for a heterogeneous patient cohort with suspected rare genetic diseases. WES could be the feasible genetic test modality to overcome the diversity and complexity of rare disease diagnostics.