• Title/Summary/Keyword: diagnostic test

Search Result 1,930, Processing Time 0.03 seconds

The Diagnostic Assessment of Hand Elevation Test in Carpal Tunnel Syndrome

  • Ma, HyunJin;Kim, Insoo
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.5
    • /
    • pp.472-475
    • /
    • 2012
  • Objective : The aim of this study is to establish the value of hand elevation test as a reproducible provocative test for the diagnosis of carpal tunnel syndrome (CTS). Methods : We had a prospective study of 45 hands of 38 patients diagnosed with CTS between April 2005 and February 2009. The diagnosis of CTS was based on the American Academy of Neurology clinical diagnostic criteria. Experimental and control group patients underwent Tinel's test, Phalen's test, carpal compression test and hand elevation test as provocative tests for CTS. Results : We used chi-square analysis to compare Tinel's test and Phalen's test, carpal compression test with hand elevation test. The sensitivity and specificity of the hand elevation test is 86.7% and 88.9% each. Tinel's test had 82.2% sensitivity and 88.9% specificity. Phalen's test had 84.4% sensitivity and 86.7% specificity. Carpal compression test had 84.4% sensitivity 82.2% specificity. Comparisons of sensitivity and specificity between hand elevation test and Tinel's test, Phalen's test, and carpal compression test had no statistically significant differences. To compare the diagnostic accuracies of four tests, the area under the non-parametric receiver operating character curve was applied. Conclusion : The hand elevation test has higher sensitivity and specificity than Tinel's test, Phalen's test, and carpal compression test. Chi-square statistical analysis confirms the hand elevation test is not ineffective campared with Tinel's test, Phalen's test, and carpal compression test.

Development of the Software to test Pattern Diagnosis Ability in Oriental Medicine (변증 능력 평가 소프트웨어의 구현)

  • Kim, Ki-Wang;Chang, Jae-Soon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.14 no.1
    • /
    • pp.70-78
    • /
    • 2010
  • Objectives : To qualify or enhance the diagnostic ability of students in Oriental Medicine, so called standardized patients are ideal modality, but because it's a man-based method, more convenient tools are required. Computer-based diagnostic ability test program gives effective way for the very purpose. So we made a pilot software evaluating Pattern Identification ability in Oriental Medicine. Methods and Materials : The pilot software was coded with Microsoft's EXCEL VBA. 87 names of Zheng (Symptom Pattern) and 674 names of symptom (including some signs) are adopted from the former standardization works conducted by Korean Institute of Oriental Medicine (KIOM) in 1996. Results : Compared with some manned modalities to test Pattern Identification ability, the test by this software shows superiority in convenience and objectivity. Conclusion : This software is world's first program to perform computer-based evaluation of Pattern Identification in Oriental Medicine, and it gives effective way to complement both written test and manned clinical performance test (CPX).

Characteristics of Insulation Diagnostic in Traction Motor Stator Windings (견인전동기 고정자 권선의 절연진단 특성)

  • Kim, Hee-Dong;Kim, Chung-Hyo;Park, Young;Park, Hyun-June
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.336-338
    • /
    • 2006
  • Diagnostic tests are used to evaluate the insulation condition of stator windings in traction motor. These tests included ac current, tan delta and maximum partial discharge. The insulation condition of stator windings was assessed by three test items. The stator windings of traction motor were m good condition. After completing the diagnostic tests, the stator windings of traction motors were subjected to gradually increasing ac voltage, until the insulation punctured. No.5 stator windings failed near rated voltage of 18.9 kV. The breakdown voltage of No.1 stator windings was 13.0. The failure was located m a line-end coil at the exit from the core slot.

  • PDF

Development of diagnostic scale for life planning in late Adolescence (청년기 생활설계 진단척도 개발)

  • Choi, Bo-A
    • Journal of Families and Better Life
    • /
    • v.28 no.5
    • /
    • pp.101-111
    • /
    • 2010
  • The purpose of this study was to develop a standardized scale to diagnostic life planning in late adolescence. A preliminary 32 item scale was developed through a literature review & a survey. 896 people responded to an online survey using the preliminary scale. A series of test, such as test-retest, item-to-total correlation, factor analysis and Cronbach' ${\alpha}$ reliability were conducted using the survey data and a scale comprising 31 items was constructed finally. The diagnostic scale for life planning in late Adolescence consisted of seven factors : (1) complete growth minds (2) life- plan (3) variety experiences (4) close relationships (5) management of healthy body (6) practical finance-plans (7) active preparation of future job. The scale is useful as a guideline for managing life of the late Adolescence. And it is helpful to them to make plan for the better life.

A Study on Utility of Magnetic Resonance Imaging for Female Pelvic Cavity using Enteral MRI Contrast Media (Enteral MRI contrast media를 이용한 여성골반 자기공명영상의 유용성)

  • Kim, Ham-Gyum
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.29-34
    • /
    • 1997
  • For radiological test in soft tissue or neighboring part with same signal intensity, proper test method and equipment shall be selected as needed. In case of female pelvic cavity, ultrasonography or computed tomography alternatively used, but MRI can be more usefully applied to design treatment method or operation plan by improving the diagnostic accuracy and careful observation of lesion characteristics. Magnetic Resonance Imaging using recently developed Enteral MRI contrast media can acquire more diagnostic information than using only intravenous contrast media. Thus this study attempted to examine the utility of anatomic structure and diagnostic acquisition by imaging the female pelvic cavity using Enteral MRI contrast media. As a result of analyzing magnetic resonance Imaging after administering Enteral MRI contrast media to pelvic cavity suspect patients, more diagnostic information media could be acquired than only using Intravenous contrast. Expecially, in the diagnosis of lesion position, shape, distinction from neighboring tissues it is thought that external Enteral MRI contrast media should be used.

  • PDF

Electric power characteristic test of diagnostic X-ray high voltage transformer by input power condition (고전압트랜스포머의 진공이 방사선출력 노이즈에 미치는 영향)

  • Kim, Young-Pyo;Cheon, Min-Woo;Park, Young-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.499-499
    • /
    • 2008
  • High voltage transformer of Diagnostic X-ray system has been contributed to wiping out disease to get a good quality images from patients. High voltage transformer of diagnostic X-ray system has been usefully used for diagnostic purpose but if high voltage transformer performances are deteriorated, low quality image will be archived. In this case, operator has to exposure to get a more good quality images. In this case, unexpected radiation could be exposed to patient and it is very harmful to the patient. And I would like to design and make equipment to checkable high voltage transformer performance after that I wish to test and study what it is most influences in radiation output quality.

  • PDF

How accurate are rapid diagnostic tests for covid-19? (코로나19 신속진단검사는 얼마나 정확한가?)

  • Yeo, In-Kwon
    • The Korean Journal of Applied Statistics
    • /
    • v.35 no.3
    • /
    • pp.435-443
    • /
    • 2022
  • In this paper, using Covid-19 diagnostic data provided by the Korea Disease Control and Prevention Agency (KDCA), we examine the probability of confirmed cases and the probability of actually being confirmed when the rapid test is negative according to the sensitivity and specificity of the rapid diagnostic kit. When we know the conditional probability of confirmation given a positive test, we induce the relationship between sensitivity and specificity, and compute the actual sensitivity of the rapid diagnosis kit based on the data of KDCA.

Contrast-Enhanced Magnetic Resonance Angiography: Dose the Test Dose Bolus Represent the Main Dose Bolus Accurately?

  • Jongmin J. Lee;Yongmin Chang;Duk-Sik Kang
    • Korean Journal of Radiology
    • /
    • v.1 no.2
    • /
    • pp.91-97
    • /
    • 2000
  • Objective: To determine whether the time-intensity curves acquired by test and main dose contrast injections for MR angiography are similar. Materials and Methods: In 11 patients, repeated contrast-enhanced 2D-turbo-FLASH scans with 1-sec interval were obtained. Both test and main dose timeintensity curves were acquired from the abdominal aorta, and the parameters of time-intensity curves for the test and main boluses were compared. The parameters used were arterial and venous enhancement times, arterial peak enhancement time, arteriovenous circulation time, enhancement duration and enhancement expansion ratio. Results: Between the main and test boluses, arterial and venous enhancement times and arteriovenous circulation time showed statistically significant correlation (p < 0.01), with correlation coefficients of 0.95, 0.92 and 0.98 respectively. Although the enhancement duration was definitely greater than infusion time, reasonable measurement of the end enhancement point in the main bolus was impossible. Conclusion: Only arterial and venous enhancement times and arteriovenous circulation time of the main bolus could be predicted from the test-bolus results. The use of these reliable parameters would lead to improvements in the scan timing method for MR angiography.

  • PDF

A Study of Pre-service Chemistry Teacher's Understanding on Entropy

  • Seo, Young-Jin;Hong, Hun-Gi
    • Journal of The Korean Association For Science Education
    • /
    • v.32 no.3
    • /
    • pp.415-427
    • /
    • 2012
  • In this study, we conducted preliminary survey, diagnostic test and in-depth interview in order to study Korean pre-service chemistry teachers' understanding on entropy and investigate how Korean pre-service chemistry teachers deal with the natural phenomenon which is related to entropy conceptions. Firstly, as a result of the preliminary survey, it was found that pre-service chemistry teachers strongly recognized entropy as the degree of disorder. Secondly, the diagnostic test showed pre-service chemistry teachers were mostly confused about whether the entropy of the universe increases during a spontaneous change, and they had a tendency to interpret the natural phenomenon related to entropy change as the change of disorder. Finally, during in-depth interview, after we explained entropy change in all diagnostic test questions with the concept of microstate, pre-service chemistry teachers revealed a better understanding about entropy. Through this research, pre-service chemistry teachers had an opportunity to reflect on their deficiencies of entropy conceptions, which will ultimately help students to approach the concept of entropy more correctly.

Diagnostic Test of XLPE Ultra High Voltage Electric Power Cable (XLPE 특고압 전력케이블의 절연 진단)

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.122-126
    • /
    • 2002
  • A diagnostic test of 15.4kV cross-linked polyethylene(XLPE) ultra high voltage power cables from generator in the Soyanggang hydro electric power plant was conducted over 3 months, beginning April 2001. According to the results, in the case of the power cables from generator 1, there was little possibility of proceeding rapid1y to failure or defect because the data from diagnosis doesn't indicate any failure, deterioration or partial discharge. However, in the case of the power cables from generator 2, the. polarization index show a slight abnormal condition of the insulator that is not severe, and the deterioration was also identified as not severe. However, the partial discharge had an abnormal condition which was severe.

  • PDF