고압전력케이블 현장진단시험용 종합 직류시험설비의 검토 (Design of a composite diagnostic DC test apparatus for high voltage power cable)

  • 류희석;강동식;심종태;이호진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2326-2328
    • /
    • 1999
  • Developments of effective and economic diagnostic apparatus for industrial plastic insulated high voltage power cables are in discontented condition still. Some report told that DC high voltage was damaged plastic insulation of a partially aged power cable to lead breakdown easily. But now, we have no alternative tools of DC diagnostic apparatus, and we try to reduce a possibility of hazard DC diagnosis. DC diagnostic apparatus still have many advantages to field cable engineer like low price, portability easy applications and sufficient data. Main hazard of DC diagnosis is excessive hight of applied voltage Recent developments for DC diagnosis use considerably low voltage. But new test methods need special measuring device and manipulator, like high input impedance voltmeter, low leakage current high voltage switches, etc. So that reason, new DC diagnostic devices are normally very expensive and have low efficiency, economically. We try to design a composite test device for 3$\sim$4 newly developed method, have economical benefit th industrial engineer.

  • PDF

고압전동기 고정자 권선의 절연열화 분석 (Analysis of Insulation Aging in High Voltage Motor Stator Windings)

  • 김희동;공태식;이영준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.200-203
    • /
    • 2006
  • Prior to destructive testing, diagnostic tests were performed in eight high voltage motors. Diagnostic tests included polarization index, ac current, dissipation factor($tan{\delta}$) and partial discharge magnitude. The rewind of motor stator insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. No. 1 motor failed near rated voltage of 12.96 kV. The breakdown voltage of No. 4 motor was 6.99 kV which is lower that expected for good quality coils in 6.6 kV class motors. The failure was located in a line-end coil at the exit from the core slot. These two motors began operation in 1994. While testing No. 7 motor, flashover occurred between the stator winding and the stator frame at 15 kV. The relationship between the diagnostic test and the drop in insulation breakdown voltage was analyzed.

  • PDF

소수력발전기 절연특성분석 (Analysis of Insulation Characteristic for Small Hydro Generator)

  • 오봉근;장정호;이광호;강동식
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.142-145
    • /
    • 2008
  • Electrical insulation of small hydro generator stator winding is one of the most important parts in generator facilities. Some stator winding insulation problems can be identified through analysis of insulation diagnostic test. So, Diagnosis of stator winding insulation is an important measure of ensuring the safe operation and extending the remaining life of small hydro generator. This paper presents case studies of insulation failure in generator stator windings and the results of insulation diagnostic test for small hydro generator stator windings. Especially, Conducting the insulation diagnostic test before the generator installed in site is very important process to keep the good insulation condition in service.

  • PDF

순환수 펌프용 고압전동기 고정자 권선의 절연내력 평가 (Estimation of Dielectric Strength in High Voltage Motor Stator Windings for Circulating Water Pump)

  • 김희동;공태식;박태성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1191-1192
    • /
    • 2015
  • To assess the deterioration condition of stator insulation, diagnostic and overpotential tests were performed on two high voltage(HV) motors for circulating water pump (CWP). Following the long term rewinding program, the diagnostic test was performed on two motors during the planning maintenance period. After completing the diagnostic test, overpotential test was done on the stator windings of HV motors. During the overpotential test, the No. 1 and No. 2 of HV motors failed at 8.8 kV and 7.9 kV, respectively. Stator windings of two HV motors had deteriorated significantly.

  • PDF

진단법의 임상시험연구와 진단정확도 (Clinical Trials and Accuracy of Diagnostic Tests)

  • 이유경;이상무
    • Journal of Genetic Medicine
    • /
    • 제8권1호
    • /
    • pp.28-34
    • /
    • 2011
  • 대부분의 의사들은 임상시험을 치료약제개발 후 의료현장에서 사용하기 위해 진행되는 과정으로 생각할 것이다. 실험실에서 개발된 기술이 진단검사로써 도입되기 위해서는 치료약제의 경우와 유사한 임상시험 과정을 거쳐 그 안정성과 유효성에 대한 검증을 필요로 한다. 치료약제의 효과검증에서 가장 우수한 근거를 얻을 수 있는 연구방법은 무작위대조연구 방법이지만, 이를 검체진단검사에 그대로 적용하기는 어렵다. 검체진단검사의 경우 비교연구가 진단정확도의 검증을 위해 현실적으로 사용할 수 있는 연구방법이지만 대상군의 모집 방법과 구분 방법, 질환대상자의 질환 심각도, 참고표준의 선택과 적용, 눈가림 여부 등 여러 요인들이 진단정확도 지표에 직접적인 영향을 주기 때문에, 좋은 근거수준의 연구결과를 얻기 위해서는 이러한 요소들을 고려한 잘 고안된 연구디자인이 중요하다. 또한 검체진단검사는 치료약제의 경우와 달리 결과를 얻기 위한 검사과정이 사용자인 일선 검사실에 의해 계속 생산되어야 하고, 검사의 개발과 발전의 속도가 빠르며, 일선검사실이 최종사용자이자 개발자인 경우가 흔하다는 특성이 있다. 저자들은 이러한 검사의 특성을 고려하여 검사법 자체의 수행능력에 대한 검증으로부터 검사법 성능평가를 위한 질환확진군과 정상군에 대한 비교연구, 일련의 질환의심자 대상의 진단정확도 평가와 임상 효과성 평가, 도입 후 일상감시로 이어지는 임상시험의 진행단계를 제안하고자 한다.

인터넷 중독자의 신체적 이상 증상에 대한진단도구 개발에 관한 연구 (A study on the Diagnostic Test for the Somatic Signs of the Internet Addiction Syndrome)

  • 박지환
    • 대한정형도수물리치료학회지
    • /
    • 제7권2호
    • /
    • pp.51-56
    • /
    • 2001
  • The purpose of this study is to make a new diagnostic test model for the physical disturbance signs for the overuser or addiction persons in internet. Variations of Somato-diagnostic testR for Internet Addiction Syndrome(Park V1.0) are follows ; 1. Are you hurt in your elbow or shoulder? 2. Do you feel stiffness in your neck? 3. Do you feel numbness of wrist on drive? 4. Are you hurt in your fingers on touch a keyboard or mouse? 5. Are you hurt in your back? 6. I feel taut on my legs sometimes. 7. I feel dim or bloodshot in my eyes. 8. I feel dry in my eyeball. 9. I feel heavy and ache on my head. 10. I can't sleep very well. 11. I have a digestive upset often. 12. My hand's full with sweat on computing. 13. I feel tremble or heavy in my heart. 14. I'm tired easily. 15. I'm not concerned about a sex impulse at all.

  • PDF

Clinical evaluation of a rapid diagnostic test kit for detection of canine coronavirus

  • Yoon, Seung-Jae;Seo, Kyoung-Won;Song, Kun-Ho
    • 대한수의학회지
    • /
    • 제58권1호
    • /
    • pp.27-31
    • /
    • 2018
  • Canine coronavirus is a single-stranded RNA virus that causes enteritis in dogs of any age. Coronaviral enteritis is seldom definitively diagnosed, since it is usually much less severe than many other types of enteritis and is self-limiting. Conventional diagnostics for the canine coronaviral enteritis such as polymerase chain reaction (PCR), virus isolation, and electron microscopic examination are inappropriate for small animal clinics due to the complicated experimental processes involved. Therefore, a commercially available lateral flow test kit based on chromatographic immunoassay techniques was tested to evaluate its performance as a first-line diagnostic test kit that could be used in clinics. The coronavirus antigen test kit detected canine coronavirus-infected dogs with 93.1% sensitivity and 97.5% specificity. The detection limit of the test kit was between $1.97{\times}10^4/mL$ and $9.85{\times}10^3/mL$ for samples with a 2-fold serial dilution from $1.25{\times}10^6\;TCID_{50}$ ($TCID_{50}$, 50% tissue culture infectious dose). Additionally, the test kit had no cross-reactivity with canine parvovirus, distemper virus, or Escherichia coli. Overall, the commercially available test kit showed good diagnostic performance in a clinical setting, with results similar to those from PCR, confirming their potential for convenient and accurate use in small animal clinics.

고압전동기 절연진단 해석 (II) (Analysis of Insulation Diagnostic Test for High Voltage motor (II))

  • 이영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2107-2109
    • /
    • 1999
  • The insulation diagnostic tests was performed at local thermal power plants high voltage motor. The insulation diagnostic tests include measurements of insulation resistance, polarization index, AC current, $tan{\delta}$, partial discharges. This paper describes Insulation characteristics for high voltage motor which located by inside and outside.

  • PDF

Agreement of two ELISAs for Mycobacterium avium subspecies paratuberculosis in cattle in Korea

  • Lee, Kyung Woo;Jung, Byeong Yeal;Hwang, In Yeong;Lee, Su Hwa;Kim, Ji Yeon;Kim, Young Hoan;Lee, Seong Hyo;Moon, Oun Kyoung;Lee, O Soo
    • 대한수의학회지
    • /
    • 제49권2호
    • /
    • pp.121-125
    • /
    • 2009
  • Paratuberculosis caused by Mycobacterium avium subspecies paratuberculosis (Mpt) is a chronic infectious enteric disease with deleterious impact on the performance in ruminants. In Korea, ELISA has been introduced to detect antibodies to Mpt in individual cattle. However, comparison study with ELISA has not been studied until now. In total, a panel of 899 serum samples obtained from dairy cattle was analyzed with two commercial ELISAs for Mpt to assess the performance. Two ELISAs employed in this study were both licensed worldwide. Two ELISAs applied onto same serum samples showed the moderate agreement (kappa value = 0.60). There was non-significant McNemar test (p = 0.0614) between two ELISA results indicating that each proportion detected by two kits did not differ. In addition, the percent agreement between two ELISA results was turned out to be 96.8% which interpreted excellent reproducibility. It was shown from this study that two ELISAs revealed moderate kappa agreement performance. The implication raised is that when ELISAs as diagnostics are used to detect Mpt in individual cattle, positive reaction by either ELISA should be interpreted as serologically Mpt positive due to presumed low sensitivity of ELISAs and their test agreement being less than 100%.

물리보다 수학을 잘 해야 물리를 잘 한다: 입학 전 수학진단점수의 일반물리학 성취도 예측타당성 검증 (Mathematical Preparedness Predicts College Grades in Physics Better than Physics Preparedness: the Predictive Validity of the Mathematical Diagnostic Test on the Freshmen's Physics Grades)

  • 신윤경;박규열;이아름;정종원
    • 공학교육연구
    • /
    • 제22권4호
    • /
    • pp.22-31
    • /
    • 2019
  • This study aims to elucidate the relationship between physics and mathematics to predict achievement for the college level of engineering courses. For the last 4 years, more than 3,000 engineering college freshmen of this study took the diagnostic tests on three subjects, which were physics, mathematics, and chemistry before enrollment. We studied how strongly these diagnostic scores can predict each general college course grades. The correlation between the physics diagnostic scores and the course grades in physics was .264, which was significantly lower than the correlation between the mathematics scores and the physics grades, .311. This stronger prediction of the mathematical diagnostic scores for the general course grades was not found when predicting the grades in chemistry. We therefore conclude that mathematical preparation can unexpectedly predict future achievement in physics better than physics preparation due to the academic interrelationships between mathematics and physics.