• Title/Summary/Keyword: diagnostic technique

Search Result 828, Processing Time 0.032 seconds

Simulation of High-Frequency Induction-Heating Application Power Supply at 2700kW Power (2700kW급 고주파 유도가열장치의 전원시스템 시뮬레이션)

  • Lee, K.S.;Koh, H.S.;Lee, Y.H.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.189-191
    • /
    • 1998
  • The development of the high- frequency induction-heating for 2700kW power range intend to make localization at forging and rolling mill part by technical innovation. And, the development makes to increase our's competitive power at technique, quality and cost. This paper describes the heart of high-frequency induction-heating technique, switching technique, a few problem in common using as an unsatisfied technique, load adjustment technique, system control, diagnostic system and auto-interface etc.

  • PDF

Self-Diagnostic Signal Monitoring System of KWP2000 Vehicle ECU using Bluetooth

  • Choi, Kwang-Hun;Lee, Hyun-Ho;Lee, Young-Choon;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.132-137
    • /
    • 2004
  • On-Board Diagnostic(OBD) systems are in most cars and light trucks on the load today. During the 1970's and early 1980's manufacturers started using electronic means to control engine functions and diagnose engine problems. The CARB's diagnostic requirements to meet EPA emission standards have been designated as OBD with a goal of monitoring all of the emissions-related components, as well as the chassis, body, accessory devices and the diagnostic control network of the vehicle for proper operation. In this paper, we present a remote measurement system for the wireless monitoring of diagnosis signal and sensors output signals of ECU adopted KWP2000, united the OBD communication protocol, on OBD-compliant vehicle using the wirless communication technique of Bluetooth. In order to measure the ECU signals, the interface circuit is designed to communicate ECU and designed terminal wirelessly according to the ISO, SAE regulation of communication protocol standard. A microprocessor S3C3410X is used for communicating ECU signals. The embedded system's software is programmed to measure the ECU signals using the ARM compiler and ANCI C based on MicroC/OS kernel to communicate between bluetooth modules using bluetooth stack. The diagnostic system is developed using Visual C++ MFC and protocol stack of bluetooth for Windows environment. The self-diagnosis and sensor output signals of ECU is able to monitor using PC with bluetooth board connected in serial port of PC. The algorithms for measuring the ECU sensor output and self-diagnostic signals are verified to monitor ECU state. At the same time, the information to fix the vehicle's problem can be shown on the developed monitoring software. The possibility for remote measurement of self-diagnosis and sensor signals of ECU adopted KWP2000 in embedded system verified through the developed systems and algorithms.

  • PDF

Antibiotic Resistance Profiles of Staphylococcus pseudintermedius Isolates from Canine Patients in Korea

  • Yoon, Jang-Won;Lee, Ki-Jong;Lee, So-Young;Chae, Min-Joo;Park, Jae-Keun;Yoo, Jong-Hyun;Park, Hee-Myung
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.12
    • /
    • pp.1764-1768
    • /
    • 2010
  • In this study, the prevalence of antibiotic resistance was examined among 74 Staphylococcus pseudintermedius strains recently isolated from clinical cases of canine pyoderma and otitis externa at the veterinary teaching hospital at Konkuk University, Korea. Bacterial resistance to the nine commonly used antibiotics was evaluated by a standard disk diffusion technique based on the guidelines of the Clinical and Laboratory Standards Institute. The results demonstrated that most S. pseudintermedius isolates were resistant to penicillin (95.9%) or tetracycline (91.9%), but highly susceptible to amoxicillin/clavulanic acid (90.5%). Among the 74 isolates, 13 mecA-positive and methicillin-resistant S. pseudintermedius (MRSP) strains were identified, displaying a high level of resistance (84.6-100%) to each of the individual antibiotics evaluated, with the exception of amoxicillin/clavulanic acid (46.2% resistance). Notably, all of the MRSP isolates exhibited simultaneous resistance to four or more different antibiotics, indicating that they are multiple drug resistant (MDR) strains. Taken together, these results imply that more careful selection or prescription of antibiotics for canine pyoderma and otitis externa should be required for reducing the emergence and/or spread of MDR strains, especially MDR-MRSP isolates, in veterinary pet clinics in Korea.

Diagnostic methods for assessing maxillary skeletal and dental transverse deficiencies: A systematic review

  • Sawchuk, Dena;Currie, Kris;Vich, Manuel Lagravere;Palomo, Juan Martin;Flores-Mir, Carlos
    • The korean journal of orthodontics
    • /
    • v.46 no.5
    • /
    • pp.331-342
    • /
    • 2016
  • Objective: To evaluate the accuracy and reliability of the diagnostic tools available for assessing maxillary transverse deficiencies. Methods: An electronic search of three databases was performed from their date of establishment to April 2015, with manual searching of reference lists of relevant articles. Articles were considered for inclusion if they reported the accuracy or reliability of a diagnostic method or evaluation technique for maxillary transverse dimensions in mixed or permanent dentitions. Risk of bias was assessed in the included articles, using the Quality Assessment of Diagnostic Accuracy Studies tool-2. Results: Nine articles were selected. The studies were heterogeneous, with moderate to low methodological quality, and all had a high risk of bias. Four suggested that the use of arch width prediction indices with dental cast measurements is unreliable for use in diagnosis. Frontal cephalograms derived from cone-beam computed tomography (CBCT) images were reportedly more reliable for assessing intermaxillary transverse discrepancies than posteroanterior cephalograms. Two studies proposed new three-dimensional transverse analyses with CBCT images that were reportedly reliable, but have not been validated for clinical sensitivity or specificity. No studies reported sensitivity, specificity, positive or negative predictive values or likelihood ratios, or ROC curves of the methods for the diagnosis of transverse deficiencies. Conclusions: Current evidence does not enable solid conclusions to be drawn, owing to a lack of reliable high quality diagnostic studies evaluating maxillary transverse deficiencies. CBCT images are reportedly more reliable for diagnosis, but further validation is required to confirm CBCT's accuracy and diagnostic superiority.

Exercise Radionuclide Ventriculography in Patients with Mitral Stenosis (승모판 협착증 환자에서 운동부하 심장풀스캔을 이용한 좌심실기능의 평가)

  • Lee, Do-Yun;Shim, Won-Heum;Kim, Han-Soo;Park, Seung-Jung;Cho, Seung-Yun;Kim, Sung-Soon;Lee, Woong-Ku;Kim, Myeong-Jin;Choe, Kyu-Ok;Park, Chang-Yun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.58-64
    • /
    • 1992
  • We performed exercise radionuclide ventriculography to evaluate left ventricular (LV) function in 35 patients with pure mitral stenosis (MS). There were 6 males and 29 females ranging from 21 to 63 years of age (mean $37{\pm}10$ years). We also studied 8 healthy men as control group (mean age $27{\pm}5$ years). Each patients was evaluated at rest and during maximal exercise on an isokinetic bicycle ergometer. Peak filling rate (PFR), peak ejection rate (PER), ejection fracion (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and cardiac output (CO) were determined by the radionuclide technique. The results were summarized as follows: 1) LV systolic dysfunction and reduced PFR were noted in patients with MS. 2) EDV as well as SV decreased with exercise in patients with MS. 3) No significant increase in EF during exercise compared to rest value was observed because it was caused by reduced EDV and SV during exercise in patients with MS. 4) CO increased with exercise was significantly lower than normal in patients with MS. 5) Patients with MS were divided into two groups according to whether SF increased more than 5% druing exercise compared to resting state or decreased. Significant difference were found between these two groups. Patients with a fall in EF with exercise were older, had larger left atrial size, and had lesser decreased in ESV during exercise.

  • PDF

Evaluation of the Usefulness for Air Gap Technique in Digital Magnification Mammography (디지털 유방확대촬영술에서 Air gap technique의 유용성 평가)

  • Kim, Mi-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.101-107
    • /
    • 2014
  • The purpose of this study was investigated optimal exposure condition in digital magnification mammography to decrease radiation dose and increase image quality of the examinee. Auto mode, the average glandular dose is higher than the manual mode. Average glandular dose and image quality were many differences on between grid and air gap technique in auto mode. However, Average glandular dose and signal-to-noise ratio were not different on between grid and air gap technique in manual mode. The signal-to-noise ratio was increased when using the air-gap technique in both mode. According to result, air gap technique may reduce average glandular dose and increase signal-to-noise ratio in digital magnification mammography.

Functional MR Imaging Using BOLD Technique in Patients with Brain Tumors (뇌종양 환자에서 BOLD 기법을 이용한 기능적 자기공명영상)

  • Kim Jeong;Yim Nam-Yeol;Shin Sang-Soo;Lim Hyo-Soon;Yoon Woong;Chung Tae-Woong;Jeong Yong-Yeon;Jeong Gwang-Woo;Park Jin-Gyoon;Kang Heoung-Keun;Jung Shin;Kang Sam-Suk;Seo Jeong-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.124-131
    • /
    • 2003
  • Purpose : To reveal clinical usefulness of functional MRI (fMRI) using sensorymotor and language stimuli for demonstrating anatomic relationship between sensorimotor or language cortices and lesions in the planning of brain tumor surgery. Materials and Methods : This study included 12 right-handed patients with brain tumors in or around sensorimotor or language cortices. Eleven patients were evaluated with primary motor and sensory stimuli. Of these patients, six patients were also evaluated with language stimuli. One patient was evaluated with language stimuli only. For fMR imaging, a 1.5T scanner was used and the EPI BOLD technique was employed. For postprocessing image, the SPM99 program and a program made by our department was utilized. We evaluated whether sensorimotor and language stimuli activate sensorimotor and language cortices. And also, clinical efficacy of revealing anatomic relationship between cerebral cortices and lesions for planning neurosurgical operation were evaluated. Finally, we compared post-operative neurologic function with pre-operative neurologic function in same patients. Results : The fMRI examination was successful in identifying the functional cortices and depicting anatomic relationship between functional cortices and lesions in all patients. In nine patients of 11 patients with identified sensorimotor cortices, postoperative grade of manual motor test was not changed, compared with preoperative grade. Whereas postoperative improved than preoperative grade in one patient of remaining two patients, postoperative aggravated than preoperative grade in the other. This result was due to atherosclerotic lacunar infarction, regardless of tumor resection. Postoperative deficit of language function was not found in seven patients with identified language cortices. Conclusion : fMRI could be a helpful method for determining the best approach to neurosurgical treatment in patients with brain tumors in or around sensorimotor or language cortices.

  • PDF