• Title/Summary/Keyword: diagnostic sensitivity

Search Result 1,256, Processing Time 0.028 seconds

Usefulness of the Alcohol Use Disorders Identification Test-Korean Revised Version in Screening for Diagnostic and Statistical Manual of Mental Disorders 5th Edition Alcohol Use Disorder among College Students

  • Kim, Sun-Jin;Kim, Jong-Sung;Kim, Sung-Soo;Jung, Jin-Kyu;Yoon, Seok-Joon;Lee, Jung-Yoon;Kim, Ji-Han
    • Korean Journal of Family Medicine
    • /
    • v.39 no.6
    • /
    • pp.333-339
    • /
    • 2018
  • Background: There is a distinction in alcohol consumption behavior between adults and college students. This study aims to verify the usability and the optimal cutoff point of Alcohol Use Disorders Identification Test-Korean revised version (AUDIT-KR) for screening alcohol use disorder in college students when the diagnostic and statistical manual of mental disorders (DSM), 5th edition diagnostic criteria is applied. Methods: A total of 922 college students living in Daejeon were enrolled and divided into two groups based on how many items they corresponded to among DSM-5 alcohol use disorder diagnostic criteria: those who corresponded to ${\geq}2$ of the 11 items were classified into the patient group (107 males, 89 females) while the others into the control group (311 males, 415 females). The participants were evaluated using AUDIT-KR to find the optimal cutoff point for screening alcohol use disorder, sensitivity, and specificity. Results: The mean${\pm}$standard deviation scores in the AUDIT-KR were $12.76{\pm}7.27$, $10.72{\pm}4.62$ for males and females, respectively, in the patient group. In contrast, in the control group the scores were $6.26{\pm}5.23$ and $3.95{\pm}3.59$ in males and females, respectively. The area under the receiver operating characteristic curve (95% confidence interval) regarding alcohol use disorder screening by AUDIT-KR was 0.768 (0.715-0.821) and 0.883 (0.848-0.919) for males and females, respectively. The optimal cutoff point of alcohol use disorder for males was >9, sensitivity 64.49%, and specificity 76.85%. The optimal cutoff point for females was >6, sensitivity 82.02%, and specificity 80.48%. Conclusion: This study suggested that AUDIT-KR can be used as a screening tool for alcohol use disorder in groups of college students when DSM-5 diagnosis criteria are applied.

Development and Validation of a Simple Index Based on Non-Enhanced CT and Clinical Factors for Prediction of Non-Alcoholic Fatty Liver Disease

  • Yura Ahn;Sung-Cheol Yun;Seung Soo Lee;Jung Hee Son;Sora Jo;Jieun Byun;Yu Sub Sung;Ho Sung Kim;Eun Sil Yu
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.413-421
    • /
    • 2020
  • Objective: A widely applicable, non-invasive screening method for non-alcoholic fatty liver disease (NAFLD) is needed. We aimed to develop and validate an index combining computed tomography (CT) and routine clinical data for screening for NAFLD in a large cohort of adults with pathologically proven NAFLD. Materials and Methods: This retrospective study included 2218 living liver donors who had undergone liver biopsy and CT within a span of 3 days. Donors were randomized 2:1 into development and test cohorts. CTL-S was measured by subtracting splenic attenuation from hepatic attenuation on non-enhanced CT. Multivariable logistic regression analysis of the development cohort was utilized to develop a clinical-CT index predicting pathologically proven NAFLD. The diagnostic performance was evaluated by analyzing the areas under the receiver operating characteristic curve (AUC). The cutoffs for the clinical-CT index were determined for 90% sensitivity and 90% specificity in the development cohort, and their diagnostic performance was evaluated in the test cohort. Results: The clinical-CT index included CTL-S, body mass index, and aspartate transaminase and triglyceride concentrations. In the test cohort, the clinical-CT index (AUC, 0.81) outperformed CTL-S (0.74; p < 0.001) and clinical indices (0.73-0.75; p < 0.001) in diagnosing NAFLD. A cutoff of ≥ 46 had a sensitivity of 89% and a specificity of 41%, whereas a cutoff of ≥ 56.5 had a sensitivity of 57% and a specificity of 89%. Conclusion: The clinical-CT index is more accurate than CTL-S and clinical indices alone for the diagnosis of NAFLD and may be clinically useful in screening for NAFLD.

Diagnostic Efficacy of PET in Soft Tissue Tumors: Comparative Study with Conventional Methods (연부 조직 종양에서 PET의 유용성: 기존의 진단법과의 비교 연구)

  • Seo, Sung-Wook;Park, Sang-Min;Cho, Hwan-Seong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.1
    • /
    • pp.32-39
    • /
    • 2005
  • Introduction: Currently, F-18 fluorodeoxyglucose positron emission tomography scans (FDG-PET) has been investigated in soft tissue tumor especially for tumor detection and noninvasive grading. However, the validity and the efficacy of FDG-PET are still unclear in clinical evaluation. The purpose of this study is to determine the efficacy of FDG-PET in compared to conventional diagnostic imaging studies currently used in the soft tissue tumor. Methods: Between March 2001 and March 2002, 29 patients (sixteen males, thirteen females, mean age, 47 years; a range from 4 to 73) diagnosed with soft tissue tumor were evaluated by both conventional diagnostic imaging and FDG-PET. Valid reference test of the local lesion was the histopathologic diagnosis, which was measured in all patients. The suspecting metastasis in the imaging studies was validated by pathology or follow up imaging for at least 6 months. Each imaging diagnosis was made independently. The accuracy of each diagnostic method was evaluated. The incremental cost accuracy ratio was determined in each diagnostic method. Results: For detection of local lesion, sensitivity, specificity, and accuracy for MRI and FDGPET scans were 91%, 57%, 83% and 95%, 43%, 83% respectively. For detection of distant lesion, sensitivity, specificity, accuracy for conventional diagnostic methods and FDG-PET scans were 77%, 89%, 87% and 92%, 94%, 93% respectively. The incremental cost accuracy ratio (ICAR) of FDG-PET for detection of distant lesion was 145,000won/%. According to ICAR for each tumor grade, PET strategy is most cost-effective at high grade tumors. Conclusions: For detection of local lesion such as recurrence or remnant tumor, FDG-PET scan was not more accurate than MRI. However, It was more accurate for detection of metastatic lesion than conventional methods. For detection of high grade tumor, PET was most costeffective than for detection of lower grade tumor.

  • PDF

Comparison of Shear Wave Elastography and Pathologic Results Using BI - RADS Category for Breast Mass (유방종괴에 대한 BI-RADS범주를 이용한 횡탄성 초음파와 병리결과 비교분석)

  • An, Hyun;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.217-223
    • /
    • 2018
  • This study to search the diagnostic performance of shear wave elastography(SWE) in breast mass and to compare the biopsy result and stiffness obtained from shear wave elastography. Diagnostic breast ultrasonography and SWE were targeted for 157 patients who had breast ultrasonography was diagnosed mass from June 2017 to September 2017. Pathology results of 157 patients showed a benign 92 patients(Age, $44.54{\pm}11.84$) and a malignancy 65 patients(Age, $51.55{\pm}10.54$). Final evaluation, biopsy result, and quantitative SWE result were obtained and compared with each other according to Breast Imaging Reporting and Data System(BI-RADS) of diagnostic breast ultrasonography. Quantitative SWE value and pathologic result showed the highest diagnostic specificity of 83.70% in Emean and sensitivity of 89.23% in Emin. Quantitative SWE result and biopsy result is statistically significant.(p=0.000). The optimal cut-off value for malignant lesions was 66.3 kPa and 63.7 kPa, respectively, for the sensitivity, specificity, high maximum mean elasticity value(Emax) and mean elasticity value(Emean) and this showed the highest diagnostic area under the ROC curve(Az) value compared to other SWE measurement(p=0.000). The addition of SWE to conventional US in breast mass make a increase diagnostic specificity and reduce unnecessary biopsy. Therefore, it is expected that it will be helpful to analyze the breast mass using the above analysis and apparatus.

Diagnostic Accuracy of Cervicovaginal Cytology in the Detection of Squamous Epithelial Lesions of the Uterine Cervix; Cytologic/Histologic Correlation of 481 Cases (자궁경부 편평상피병변에서 자궁경부질도말 세포검사의 진단정확도 : 481예의 세포-조직 상관관계)

  • Jin, So-Young;Park, Sang-Mo;Kim, Mee-Sun;Jeen, Yoon-Mi;Kim, Dong-Won;Lee, Dong-Wha
    • The Korean Journal of Cytopathology
    • /
    • v.19 no.2
    • /
    • pp.111-118
    • /
    • 2008
  • Background : Cervicovaginal cytology is a screening test of uterine cervical cancer. The sensitivity of cervicovaginal cytology is less than 50%, but studies of cytologic/histologic correlation are limited. We analyzed the diagnostic accuracy of cervicovaginal cytology in the detection of the squamous epithelial lesions of the uterine cervix and investigate the cause of diagnostic discordance. Materials and Methods : We collected a total of 481 sets of cervicovaginal cytology and biopsies over 5 years. The cytologic diagnoses were categorized based on The Bethesda System and the histologic diagnoses were classified as negative, flat condyloma, cervical intraepithelial neoplasia (CIN) I, CIN II, CIN III, or squamous cell carcinoma. Cytohistologic discrepancies were reviewed. Results: The concordance rate between the cytological and the histological diagnosis was 79.0%. The sensitivity and specificity of cervicovaginal cytology were 80.6% and 92.6%, respectively. Its positive predictive value and negative predictive value were 93.7% and 77.7%, respectively. The false negative rate was 19.4%. Among 54 false negative cytology cases, they were confirmed by histology as 50 flat condylomas, 2 CIN I, 1 CIN III, and 1 squamous cell carcinoma. The causes of false negative cytology were sampling errors in 75.6% and interpretation errors in 24.4%. The false positive rate was 7.4%. Among 15 false positive cytology cases, they were confirmed by histology as 12 atypical squamous cells of undetermined significance (ASCUS) and 3 low grade squamous intraepithelial lesions (LSIL). The cause of error was interpretation error in all cases. The overall diagnostic accuracy of cervicovaginal cytology was 85.7%. Conclusions : Cervicovaginal cytology shows high overall diagnostic accuracy and is a useful primary screen of uterine cervical cancer.

Accuracy of Magnetic Resonance Imaging in Pretreatment Lymph Node Assessment for Gynecological Malignancies

  • Sufian, Saira Naz;Masroor, Imrana;Mirza, Waseem;Hussain, Zainab;Hafeez, Saima;Sajjad, Zafar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.11
    • /
    • pp.4705-4709
    • /
    • 2014
  • Objective: To determine the accuracy of magnetic resonance imaging (MRI) in detection of metastasis in pelvic and para-aortic lymph nodes from different gynecological malignancies. Materials and Methods: This retrospective cross sectional analytic study was conducted at the Department of Diagnostic Radiology, Aga Khan University Hospital Karachi Pakistan from January 2011 to December 2012. A sample of 48 women, age range between 20-79 years, fulfilling inclusion criteria were included. All patients had histopathologically proven gynecological malignancies in the cervix, endometrium or ovary and presented for a pretreatment MRI to our radiology department. Results: MRI was 100% sensitive and had a 100% positive predictive value to detect lymph node metastasis in lymph nodes with spiculated margins and 100% sensitive with a 75% positive predictive value to detect lymph node metastasis in a lymph node with lobulated margins. The sensitivity and positive predictive value of MRI to detect heterogeneous nodal enhancement were 100% and 75% respectively. Conclusions: Our study results reinforce that MRI should be used as a modality of choice in the pretreatment assessment of lymph nodes in proven gynaecological malignancies in order to determine the line of patientmanagement, distinguishing surgical from non-surgical cases.

Bacterial contaminants in extended boar semen and selection of effective antimicrobials (돼지 희석정액의 세균오염도 및 유효 항생제 선발)

  • Kim, Ha-Young;Byun, Jae-Won;Shin, Dong-Ho;Kim, Hyoung-Soon;Yoon, Hachung;Park, Choi-Kyu;Lee, O-Soo;Jung, Byeong Yeal
    • Korean Journal of Veterinary Research
    • /
    • v.50 no.2
    • /
    • pp.125-131
    • /
    • 2010
  • Bacterial contamination is an unavoidable finding of the semen collection process in boar and can lead in deleterious effects on semen quality and longevity if left uncontrolled. The purpose of this study is to identify the bacteria in extended boar semen and to select the effective antimicrobials to control of the contaminants. Of 116 extended boar semen samples submitted from eight AI centers in Korea, 39 (33.6%) samples were positive for bacterial contamination. Among 39 contaminated semen, most of them (84.6%) were contaminated with one or two bacterial species and there was no significant difference between two age groups $(\leq\;24\;and\;>\;24\;month\;old).$ Stenotrophomonas maltophilia (n = 18) was the most predominant bacterium followed by Elizabethkingia meningoseptica (n = 12), Sphingomonas paucimobilis (n = 12), Myroides spp. (n = 5), Ochrobactrum anthropi (n = 3), and so on. Enrofloxacin (72.9%), florfenicol (72.9%), bacitracin (49.2%) and tylosin (49.2%) showed higher sensitivity compared with penicillin (13.6%) or aminoglycosides (6.8%-18.6%). Brucella spp., Leptospira spp., Mycoplasma hyopneumoniae, Mycoplasma hyorhinis, Mycobacterium tuberculosis complex were not detected in semen by PCR.

The Role of Core Needle Biopsy for the Evaluation of Thyroid Nodules with Suspicious Ultrasound Features

  • Sae Rom Chung;Jung Hwan Baek;Young Jun Choi;Tae-Yon Sung;Dong Eun Song;Tae Yong Kim;Jeong Hyun Lee
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.158-165
    • /
    • 2019
  • Objective: Recent studies demonstrated that core needle biopsy (CNB) can effectively reduce the possibility of inconclusive results and prevent unnecessary diagnostic surgery. However, the effectiveness of CNB in patients with suspicious thyroid nodules has not been fully evaluated. This prospective study aimed to determine the potential of CNB to assess thyroid nodules with suspicious ultrasound (US) features. Materials and Methods: Patients undergoing CNB for thyroid nodules with suspicious features on US were enrolled between May and August 2016. Diagnostic performance and the incidence of non-diagnostic results, inconclusive results, conclusive results, malignancy, unnecessary surgery, and complications were analyzed. Subgroup analysis according to nodule size was performed. The risk factors associated with inconclusive results were evaluated using multivariate logistic regression analysis. Results: A total of 93 patients (102 thyroid nodules) were evaluated. All samples obtained from CNB were adequate for diagnosis. Inconclusive results were seen in 12.7% of cases. The diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value for diagnosis of malignancy were 93.8%, 100%, 100%, 78.9%, and 95%, respectively. None of the patients underwent unnecessary surgery. The diagnostic performance was not significantly different according to nodule size. On multivariate logistic regression analysis, larger nodule size and shorter needle length were independent risk factors associated with inconclusive results. Conclusion: Samples obtained by CNB were sufficient for diagnosis in all cases and resulted in high diagnostic values and conclusive results in the evaluation of suspicious thyroid nodules. These findings indicated that CNB is a promising diagnostic tool for suspicious thyroid nodules.

Diagnostic accuracy of Insight intraoral film on dental caries (Kodak Insight 구내필름의 치아우식증 진단능에 대한 연구)

  • Yoon Young Nam;Lee Sang-Rae;Lee Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.34 no.1
    • /
    • pp.19-23
    • /
    • 2004
  • Purpose: To compare the diagnostic accuracy of Kodak Insight film with other intra-oral films in the detection of dental caries. Materials and Methods : Periapical radiographs of 99 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were made on Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Kodak Insight films and automatically processed. Six dentists examined the presence of dental caries using a five-point confidence rating scale and compared the diagnostic accuracy by ROC (Receiver Operating Characteristic) analysis and ANOVA test. Results: The sensitivity of Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Insight film were 0.84, 0.77, 0.75 and 0.79 respectively. The specificity of Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Insight film were 0.97. 0.95. 0.96 and 0.94 respectively. The mean ROC areas (Az) of Kodak Ultra speed, Ektaspeed, Agfa Ektaspeed and Insight film were 0.917, 0.910, 0.894, 0.909 respectively. There was no significant differences between Az of Insight film and other films (p = 0.178). Conclusion: Theses results suggested that Kodak Insight film have the comparative diagnostic accuracy of dental caries with Ultraspeed and Ektaspeed films.

  • PDF

Sample size and statistical power consideration for diagnostic test research

  • Kim, Eu Tteum;Park, Choi Kyu;Pak, Son Il
    • Korean Journal of Veterinary Research
    • /
    • v.48 no.3
    • /
    • pp.357-361
    • /
    • 2008
  • Although power analysis is of important tool of research, investigators in veterinary medicine are unaware of the concepts of the statistical power. Two types of error occur in classical hypothesis testing and, those errors should be avoided, if possible. Since power is highly dependent on the sample size, whenever declaring non-statistically significant result they should consider the potential for committing a Type II error in their studies, which refers to the probability of falsely stating that two treatments are equivalent despite true difference between them. Also, sample size determination is one of the most important tasks facing the researcher when planning a diagnostic study, and provides valuable information on the characteristics of a test performance. This type of analysis forms the basis for proper interpretation of test results. The aim of this article was to re-evaluate some selected studies on diagnostic test reported in the domestic veterinary publications to determine the power and necessary sample size for inequality testing to ensure the desired power. Power calculations were illustrated using real-life examples of comparison of a new test and a reference test for detecting antibodies of various animal diseases. Factors affecting to the power were also discussed.