Purpose This study aimed to investigate the diagnostic performance of features suggestive of nodal metastasis on preoperative MRI in patients with invasive breast cancer. Materials and Methods We retrospectively reviewed the preoperative breast MRI of 192 consecutive patients with surgically proven invasive breast cancer. We analyzed MRI findings of axillary lymph nodes with regard to the size, long/short ratio, cortical thickness, shape and margin of the cortex, loss of hilum, asymmetry, signal intensity (SI) on T2-weighted images (T2WI), degree of enhancement in the early phase, and enhancement kinetics. Receiver operating characteristic (ROC) analysis, chi-square test, t test, and McNemar's test were used for statistical analysis. Results Increased shorter diameter, uneven cortical shape, increased cortical thickness, loss of hilum, asymmetry, irregular cortical margin, and low SI on T2WI were significantly suggestive of metastasis. ROC analysis revealed the cutoff value for the shorter diameter and cortical thickness as 8.05 mm and 2.75 mm, respectively. Increased cortical thickness (> 2.75 mm) and uneven cortical shape showed significantly higher sensitivity than other findings in McNemar's test. Irregular cortical margins showed the highest specificity (100%). Conclusion Cortical thickness > 2.75 mm and uneven cortical shape are more sensitive parameters than other findings, and an irregular cortical margin is the most specific parameter for predicting axillary metastasis in patients with invasive breast cancer.
Eun Joo Park;Seung Ho Kim;Sang Joon Park;Tae Wook Baek
Journal of the Korean Society of Radiology
/
v.82
no.1
/
pp.116-127
/
2021
Purpose To evaluate the feasibility of texture analysis of gray-scale ultrasound (US) images for staging of hepatic fibrosis. Materials and Methods Altogether, 167 patients who had undergone routine US and laboratory tests for a fibrosis-4 (FIB-4) index were included. Texture parameters were measured using a dedicated in-house software. Regions of interest were placed in five different segments (3, 5, 6, 7, 8) for each patient. The FIB-4 index was used as the reference standard for hepatic fibrosis grade. Comparisons of the texture parameters between different fibrosis groups were performed with the Student's t-test or Mann-Whitney U-test. Diagnostic performance was evaluated by receiver operating curve analysis. Results The study population comprised of patients with no fibrosis (FIB-4 < 1.45, n = 50), mild fibrosis (1.45 ≤ FIB-4 ≤ 2.35, n = 37), moderate fibrosis (2.35 < FIB-4 ≤ 3.25, n = 27), and severe fibrosis (FIB-4 > 3.25, n = 53). Skewness in hepatic segment 5 showed a difference between patients with no fibrosis and mild fibrosis (0.2392 ± 0.3361, 0.4134 ± 0.3004, respectively, p = 0.0109). The area under the curve of skewness for discriminating patients with no fibrosis from those with mild fibrosis was 0.660 (95% confidence interval, 0.551-0.758), with an estimated accuracy, sensitivity, specificity of 64%, 87%, 48%, respectively. Conclusion A significant difference was observed regarding skewness in segment 5 between patients with no fibrosis and patients with mild fibrosis.
Koung Mi Kang;Kyung Min Kim;In Seong Kim;Joo Hyun Kim;Ho Kang;So Young Ji;Yun-Sik Dho;Hyongmin Oh;Hee-Pyoung Park;Han Gil Seo;Sung-Min Kim;Seung Hong Choi;Chul-Kee Park
Korean Journal of Radiology
/
v.24
no.6
/
pp.553-563
/
2023
Objective: Functional magnetic resonance imaging (fMRI) and diffusion tensor imaging-derived tractography (DTI-t) contribute to the localization of language areas, but their accuracy remains controversial. This study aimed to investigate the diagnostic performance of preoperative fMRI and DTI-t obtained with a simultaneous multi-slice technique using intraoperative direct cortical stimulation (DCS) or corticocortical evoked potential (CCEP) as reference standards. Materials and Methods: This prospective study included 26 patients (23-74 years; male:female, 13:13) with tumors in the vicinity of Broca's area who underwent preoperative fMRI and DTI-t. A site-by-site comparison between preoperative (fMRI and DTI-t) and intraoperative language mapping (DCS or CCEP) was performed for 226 cortical sites to calculate the sensitivity and specificity of fMRI and DTI-t for mapping Broca's areas. For sites with positive signals on fMRI or DTI-t, the true-positive rate (TPR) was calculated based on the concordance and discordance between fMRI and DTI-t. Results: Among 226 cortical sites, DCS was performed in 100 sites and CCEP was performed in 166 sites. The specificities of fMRI and DTI-t ranged from 72.4% (63/87) to 96.8% (122/126), respectively. The sensitivities of fMRI (except for verb generation) and DTI-t were 69.2% (9/13) to 92.3% (12/13) with DCS as the reference standard, and 40.0% (16/40) or lower with CCEP as the reference standard. For sites with preoperative fMRI or DTI-t positivity (n = 82), the TPR was high when fMRI and DTI-t were concordant (81.2% and 100% using DCS and CCEP, respectively, as the reference standards) and low when fMRI and DTI-t were discordant (≤ 24.2%). Conclusion: fMRI and DTI-t are sensitive and specific for mapping Broca's area compared with DCS and specific but insensitive compared with CCEP. A site with a positive signal on both fMRI and DTI-t represents a high probability of being an essential language area.
Younjung Choi;Sun Mi Kim;Mijung Jang;Bo La Yun;Eunyoung Kang;Eun-Kyu Kim;So Yeon Park;Bohyoung Kim;Nariya Cho;Woo Kyung Moon
Korean Journal of Radiology
/
v.23
no.9
/
pp.866-877
/
2022
Objective: The optimal imaging approach for evaluating pathological nipple discharge remains unclear. We investigated the value of adding ductography to ultrasound (US) for evaluating pathologic nipple discharge in patients with negative mammography findings. Materials and Methods: From July 2003 to December 2018, 101 women (mean age, 46.3 ± 12.2 years; range, 23-75 years) with pathologic nipple discharge were evaluated using pre-ductography (initial) US, ductography, and post-ductography US. The imaging findings were reviewed retrospectively. The standard reference was surgery (70 patients) or > 2 years of follow-up with US (31 patients). The diagnostic performances of initial US, ductography, and post-ductography US for detecting malignancy were compared using the McNemar's test or a generalized estimating equation. Results: In total, 47 papillomas, 30 other benign lesions, seven high-risk lesions, and 17 malignant lesions were identified as underlying causes of pathologic nipple discharge. Only eight of the 17 malignancies were detected on the initial US, while the remaining nine malignancies were detected by ductography. Among the nine malignancies detected by ductography, eight were detected on post-ductography US and could be localized for US-guided intervention. The sensitivities of ductography (94.1% [16/17]) and post-ductography US (94.1% [16/17]) were significantly higher than those of initial US (47.1% [8/17]; p = 0.027 and 0.013, respectively). The negative predictive value of post-ductography US (96.9% [31/32]) was significantly higher than that of the initial US (83.3% [45/54]; p = 0.006). Specificity was significantly higher for initial US than for ductography and post-ductography US (p = 0.001 for all). Conclusion: The combined use of ductography and US has a high sensitivity for detecting malignancy in patients with pathologic nipple discharge and negative mammography. Ductography findings enable lesion localization on second-look post-ductography US, thus facilitating the selection of optimal treatment plans.
Hyunsuk Yoo;Eun Young Kim;Hyungjin Kim;Ye Ra Choi;Moon Young Kim;Sung Ho Hwang;Young Joong Kim;Young Jun Cho;Kwang Nam Jin
Korean Journal of Radiology
/
v.23
no.10
/
pp.1009-1018
/
2022
Objective: This study aimed to investigate the feasibility of using artificial intelligence (AI) to identify normal chest radiography (CXR) from the worklist of radiologists in a health-screening environment. Materials and Methods: This retrospective simulation study was conducted using the CXRs of 5887 adults (mean age ± standard deviation, 55.4 ± 11.8 years; male, 4329) from three health screening centers in South Korea using a commercial AI (Lunit INSIGHT CXR3, version 3.5.8.8). Three board-certified thoracic radiologists reviewed CXR images for referable thoracic abnormalities and grouped the images into those with visible referable abnormalities (identified as abnormal by at least one reader) and those with clearly visible referable abnormalities (identified as abnormal by at least two readers). With AI-based simulated exclusion of normal CXR images, the percentages of normal images sorted and abnormal images erroneously removed were analyzed. Additionally, in a random subsample of 480 patients, the ability to identify visible referable abnormalities was compared among AI-unassisted reading (i.e., all images read by human readers without AI), AI-assisted reading (i.e., all images read by human readers with AI assistance as concurrent readers), and reading with AI triage (i.e., human reading of only those rendered abnormal by AI). Results: Of 5887 CXR images, 405 (6.9%) and 227 (3.9%) contained visible and clearly visible abnormalities, respectively. With AI-based triage, 42.9% (2354/5482) of normal CXR images were removed at the cost of erroneous removal of 3.5% (14/405) and 1.8% (4/227) of CXR images with visible and clearly visible abnormalities, respectively. In the diagnostic performance study, AI triage removed 41.6% (188/452) of normal images from the worklist without missing visible abnormalities and increased the specificity for some readers without decreasing sensitivity. Conclusion: This study suggests the feasibility of sorting and removing normal CXRs using AI with a tailored cut-off to increase efficiency and reduce the workload of radiologists.
You Na Kim;Jin Wook Choi;Yong Cheol Lim;Jihye Song;Ji Hyun Park;Woo Sang Jung
Korean Journal of Radiology
/
v.23
no.2
/
pp.246-255
/
2022
Objective: To determine the usefulness of Silent MR angiography (MRA) for evaluating intracranial aneurysms treated with stent-assisted coil embolization. Materials and Methods: Ninety-nine patients (101 aneurysms) treated with stent-assisted coil embolization (Neuroform atlas, 71 cases; Enterprise, 17; LVIS Jr, 9; and Solitaire AB, 4 cases) underwent time-of-flight (TOF) MRA and Silent MRA in the same session using a 3T MRI system within 24 hours of embolization. Two radiologists independently interpreted both MRA images retrospectively and rated the image quality using a 5-point Likert scale. The image quality and diagnostic accuracy of the two modalities in the detection of aneurysm occlusion were further compared based on the stent design and the site of aneurysm. Results: The average image quality scores of the Silent MRA and TOF MRA were 4.38 ± 0.83 and 2.78 ± 1.04, respectively (p < 0.001), with an almost perfect interobserver agreement. Silent MRA had a significantly higher image quality score than TOF MRA at the distal internal carotid artery (n = 57, 4.25 ± 0.91 vs. 3.05 ± 1.16, p < 0.001), middle cerebral artery (n = 21, 4.57 ± 0.75 vs. 2.19 ± 0.68, p < 0.001), anterior cerebral artery (n = 13, 4.54 ± 0.66 vs. 2.46 ± 0.66, p < 0.001), and posterior circulation artery (n = 10, 4.50 ± 0.71 vs. 2.90 ± 0.74, p = 0.013). Silent MRA had superior image quality score to TOF MRA in the stented arteries when using Neuroform atlas (4.66 ± 0.53 vs. 3.21 ± 0.84, p < 0.001), Enterprise (3.29 ± 1.59 vs. 1.59 ± 0.51, p = 0.003), LVIS Jr (4.33 ± 1.89 vs. 1.89 ± 0.78, p = 0.033), and Solitaire AB stents (4.00 ± 2.25 vs. 2.25 ± 0.96, p = 0.356). The interpretation of the status of aneurysm occlusion exhibited significantly higher sensitivity with Silent MRA than with TOF MRA when using the Neuroform Atlas stent (96.4% vs. 14.3%, respectively, p < 0.001) and LVIS Jr stent (100% vs. 20%, respectively, p = 0.046). Conclusion: Silent MRA can be useful to evaluate aneurysms treated with stent-assisted coil embolization, regardless of the aneurysm location and type of stent used.
Seo Young Kang;Ji Young Yun;Yeon-Koo Kang;Byung Seok Moon;Hai-Jeon Yoon;Min Young Yoo;Bom Sahn Kim
Korean Journal of Radiology
/
v.24
no.7
/
pp.690-697
/
2023
Objective: 18F-FP-CIT positron emission tomography (PET) is known for its high sensitivity and specificity for evaluating striatal dopamine transporter (DAT) binding. Recently, for the early diagnose of Parkinson's disease, many researchers focused on the diagnosis of synucleinopathy in organs involved in non-motor symptoms of Parkinson's disease. We investigated the feasibility of salivary gland uptake on 18F-FP-CIT PET as a new biomarker in patients with parkinsonism. Materials and Methods: A total of 219 participants with confirmed or presumed parkinsonism, including 54 clinically diagnosed idiopathic Parkinson's disease (IPD), 59 suspected and yet undiagnosed, and 106 with secondary parkinsonism, were enrolled. The standardized uptake value ratio (SUVR) of the salivary glands was measured on both early and delayed 18F-FP-CIT PET scans using the cerebellum as the reference region. Additionally, the delayed-to-early ratio (DE_ratio) of salivary gland was obtained. The results were compared between patients with different PET patterns. Results: The SUVR in early 18F-FP-CIT PET scan was significantly higher in patients with IPD pattern compared that in the non-dopaminergic degradation group (0.5 ± 0.19 vs. 0.6 ± 0.21, P < 0.001). Compared with the non-dopaminergic degradation group, the DE_ratio was significantly lower in patients with IPD (5.05 ± 1.7 vs. 4.0 ± 1.31, P < 0.001) or atypical parkinsonism patterns (5.05 ± 1.7 vs. 3.76 ± 0.96, P < 0.05). The DE_ratio was moderately and positively correlated with striatal DAT availability in both the whole striatum (r = 0.37, P < 0.001) and posterior putamen (r = 0.36, P < 0.001). Conclusion: Parkinsonism patients with an IPD pattern exhibited a significant increase in uptake on early 18F-FP-CIT PET and a decrease in the DE_ratio in the salivary gland. Our findings suggest that salivary gland uptake of dual-phase 18F-FP-CIT PET can provide diagnostic information on DAT availability in patients with Parkinson's disease.
Young Hun Jeon;Ji Ye Lee;Roh-Eul Yoo;Jung Hyo Rhim;Kyung Hoon Lee;Kyu Sung Choi;Inpyeong Hwang;Koung Mi Kang;Ji-hoon Kim
Korean Journal of Radiology
/
v.24
no.9
/
pp.912-923
/
2023
Objective: This study aimed to validate the risk stratification system (RSS) and biopsy criteria for cervical lymph nodes (LNs) proposed by the Korean Society of Thyroid Radiology (KSThR). Materials and Methods: This retrospective study included a consecutive series of preoperative patients with thyroid cancer who underwent LN biopsy, ultrasound (US), and computed tomography (CT) between December 2006 and June 2015. LNs were categorized as probably benign, indeterminate, or suspicious according to the current US- and CT-based RSS and the size thresholds for cervical LN biopsy as suggested by the KSThR. The diagnostic performance and unnecessary biopsy rates were calculated. Results: A total of 277 LNs (53.1% metastatic) in 228 patients (mean age ± standard deviation, 47.4 years ± 14) were analyzed. In US, the malignancy risks were significantly different among the three categories (all P < 0.001); however, CT-detected probably benign and indeterminate LNs showed similarly low malignancy risks (P = 0.468). The combined US + CT criteria stratified the malignancy risks among the three categories (all P < 0.001) and reduced the proportion of indeterminate LNs (from 20.6% to 14.4%) and the malignancy risk in the indeterminate LNs (from 31.6% to 12.5%) compared with US alone. In all image-based classifications, nodal size did not affect the malignancy risks (short diameter [SD] ≤ 5 mm LNs vs. SD > 5 mm LNs, P ≥ 0.177). The criteria covering only suspicious LNs showed higher specificity and lower unnecessary biopsy rates than the current criteria, while maintaining sensitivity in all imaging modalities. Conclusion: Integrative evaluation of US and CT helps in reducing the proportion of indeterminate LNs and the malignancy risk among them. Nodal size did not affect the malignancy risk of LNs, and the addition of indeterminate LNs to biopsy candidates did not have an advantage in detecting LN metastases in all imaging modalities.
Sae Rom Chung;Jung Hwan Baek;Yun Hwa Rho;Young Jun Choi;Tae-Yon Sung;Dong Eun Song;Tae Yong Kim;Jeong Hyun Lee
Korean Journal of Radiology
/
v.23
no.11
/
pp.1102-1111
/
2022
Objective: To evaluate the ultrasonography (US) features for diagnosing metastasis in cervical lymph nodes (LNs) in patients with thyroid cancer and compare the US classification of risk of LN metastasis between European and Korean guidelines. Materials and Methods: From January 2014 to December 2018, US-guided fine-needle aspiration was performed on 836 LNs from 714 patients for the preoperative nodal staging of thyroid cancer. The US features of LNs were retrospectively reviewed for the following features: size, presence of hilum, margin, orientation, cystic change, punctate echogenic foci (PEF), large echogenic foci, eccentric cortical thickening, abnormal vascularity, and cortical hyperechogenicity. A multiple logistic regression analysis was performed to identify the independent US features for the diagnosis of metastatic LNs. The diagnostic performance of independent US features was subsequently evaluated. LNs were categorized according to the Korean Thyroid Imaging Reporting and Data System (K-TIRADS) and European Thyroid Association (ETA) guidelines, and the correlation between the two sets of classifications was assessed. Results: Absence of the hilum, presence of cystic changes, PEF, abnormal vascularity, and cortical hyperechogenicity were independent US features of metastatic LNs. Cystic changes, PEF, abnormal vascularity, and cortical hyperechogenicity showed high specificity (86.8%-99.6%). The absence of the hilum had the highest sensitivity yet low specificity (66.4%). When LNs were classified according to the ETA guidelines and K-TIRADS, they yielded similar categorizations of malignancy risks and were strongly correlated (Spearman coefficient, 0.9766 [95% confidence interval, 0.973-0.979]). According to the ETA guidelines, 9.8% (82/836) of LNs were classified as "not specified." Conclusion: Absence of hilum, cystic changes, PEF, abnormal vascularity, and cortical hyperechogenicity were independent US features suggestive of metastatic LNs in thyroid cancer. Both K-TIRADS and the ETA guidelines provided similar risk stratification for metastatic LNs with a high correlation; however, the ETA guidelines failed to classify 9.8% of LNs into a specific risk stratum. These results may provide a basis for revising LN classification in future guidelines.
Li Kaike;Riel Castro-Zunti;Seok-Beom Ko;Gong Yong Jin
Journal of the Korean Society of Radiology
/
v.85
no.4
/
pp.769-779
/
2024
Purpose To determine the pros and cons of an artificial intelligence (AI) model developed to diagnose acute rib fractures in chest CT images of patients with chest trauma. Materials and Methods A total of 1209 chest CT images (acute rib fracture [n = 1159], normal [n = 50]) were selected among patients with chest trauma. Among 1159 acute rib fracture CT images, 9 were randomly selected for AI model training. 150 acute rib fracture CT images and 50 normal ones were tested, and the remaining 1000 acute rib fracture CT images was internally verified. We investigated the diagnostic accuracy and errors of AI model for the presence and location of acute rib fractures. Results Sensitivity, specificity, positive and negative predictive values, and accuracy for diagnosing acute rib fractures in chest CT images were 93.3%, 94%, 97.9%, 82.5%, and 95.6% respectively. However, the accuracy of the location of acute rib fractures was low at 76% (760/1000). The cause of error in the diagnosis of acute rib fracture seemed to be a result of considering the scapula or clavicle that were in the same position (66%) or some ribs that were not recognized (34%). Conclusion The AI model for diagnosing acute rib fractures showed high accuracy in detecting the presence of acute rib fractures, but diagnosis of the exact location of rib fractures was limited.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.