• Title/Summary/Keyword: diagnostic

Search Result 11,716, Processing Time 0.036 seconds

Determination of Consistency according to the Status of Supplementary Education for Radiation Safety Management Managers (방사선안전관리책임자 보수교육의 현황에 따른 정합성 판단)

  • Seung-Chul Kim
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.7-12
    • /
    • 2024
  • Medical institutions wishing to install and operate diagnostic radiation generators must complete appointment training within one year of appointment based on the 「Medical Act」 and the 「Rules on Safety Management of Diagnostic Radiation Generator Devices」 which will come into effect on January 1, 2024. Additionally, You must receive supplementary education every three years from the date you received it. The strengthening of safety management for diagnostic radiation generators used in medical institutions means that although the radiation exposure that may occur when using diagnostic radiation generators is low, the risk of carcinogenesis may be higher than previously evaluated. In addition, safety management of diagnostic radiation generators can be said to be an essential requirement because it has been reported that the incidence of leukemia and other diseases is increasing in diagnostic radiation tests. However, the safety management training targets and programs for radiation exposure management operated by other organizations other than diagnostic radiation generators are significantly different. In addition, since the public institutions that are responsible for radiation safety management are divided, there is a risk of duplicative, excessive, and under-administrative application to medical institutions and educational institutions that install and operate diagnostic radiation generators. Therefore, we would like to determine their consistency by comparing domestic and foreign related cases and the provisions of the 「Medical Act」 and the 「Nuclear Safety Act」.

Trends in Diagnostic Technology for Respiratory Infectious Disease (호흡기 감염병 진단 기술 동향)

  • J.W. Park;H.-S. Seo;C. Huh;S.J. Park
    • Electronics and Telecommunications Trends
    • /
    • v.39 no.4
    • /
    • pp.54-62
    • /
    • 2024
  • The emergence and resurgence of novel respiratory infectious diseases since the turn of the millennium, including SARS, H1N1 flu, MERS, and COVID-19, have posed a significant global health threat. Efforts to combat these threats have involved various approaches, however, continued research and development are crucial to prepare for the possibility of emerging viruses and viral variants. Direct detection methods for viral pathogens include molecular diagnostic techniques and immunodiagnostic methods, while indirect diagnostic methods involve detecting changes in the condition of infected patients through imaging diagnostics, gas analysis, and biosignal measurement. Molecular diagnostic techniques, utilizing advanced technologies such as gene editing, are being developed to enable faster detection than traditional PCR methods, and research is underway to improve the efficiency of diagnostic devices. Diagnostic technologies for infectious diseases continue to evolve, and several key trends are expected to emerge in the future. Automation will facilitate widespread adoption of rapid and accurate diagnostics, portable diagnostic devices will enable immediate on-site diagnosis by healthcare professionals, and advancements in AI-based deep learning diagnostic models will enhance diagnostic accuracy.

Activation of JNKs is essential for BMP9-induced osteogenic differentiation of mesenchymal stem cells

  • Zhao, Yan-Fang;Xu, Jing;Wang, Wen-Juan;Wang, Jin;He, Juan-Wen;Li, Li;Dong, Qian;Xiao, Yan;Duan, Xing-Lian;Yang, Xue;Liang, Yi-Wen;Song, Tao;Tang, Min;Zhao, Dan;Luo, Jin-Yong
    • BMB Reports
    • /
    • v.46 no.8
    • /
    • pp.422-427
    • /
    • 2013
  • Although BMP9 is highly capable of promoting osteogenic differentiation of mesenchymal stem cell (MSCs), the molecular mechanism involved remains to be fully elucidated. Here, we explore the possible involvement and detail role of JNKs (c-Jun N-terminal kinases) in BMP9-induced osteogenic differentiation of MSCs. It was found that BMP9 stimulated the activation of JNKs in MSCs. BMP9-induced osteogenic differentiation of MSCs was dramatically inhibited by JNKs inhibitor SP600125. Moreover, BMP9-activated Smads signaling was decreased by SP600125 treatment in MSCs. The effects of inhibitor are reproduced with adenoviruses expressing siRNA targeted JNKs. Taken together, our results revealed that JNKs was activated in BMP9-induced osteogenic differentiation of MSCs. What is most noteworthy, however, is that inhibition of JNKs activity resulted in reduction of BMP9-induced osteogenic differentiation of MSCs, implying that activation of JNKs is essential for BMP9 osteoinductive activity.

Radiofrequency Facet Joint Denervation in the Treatment of Low Back Pain: Relationship with the Diagnostic Block (요부 후지낵측지 고주파 열응고술: 진단적 차단과의 연관성)

  • Shim, Jae-Chol;Seung, Ik-Sang
    • The Korean Journal of Pain
    • /
    • v.14 no.2
    • /
    • pp.218-224
    • /
    • 2001
  • Background: Response to diagnostic blocks does not consistently predict the outcome of interventional facet denervation. We investigated the relationship between pain relief by the percutaneous radiofrequency denervation of the lumbar zygapophysial joints with the result of facet joint diagnostic local anesthetic injection in patients with back pain originating from the lumbar zygapophysial joint. Methods: There were 35 patients enrolled, with ranging in age from 25 to 76 years ($52.6{\pm}12.7$ years, mean ${\pm}$ SD). We studied 7 men (20%) and 28 women (80%). All patients underwent double diagnostic block of $L_{3/4}$, $L_{4/5}$ and $L_5-S_1$ facet joint with 0.5% bupivacaine. The 35 patients fell into the following group. (1) Group A (n = 16): those who felt clear relief (pain free with Likert scale) from the double diagnostic block (2) Group B (n = 19): 11 patients who were always equivocal in their response to the double diagnostic block and 8 patients who were either pain free or equivocal in their response to the double diagnostic block. All 11 patients were done the facet joint denervation. The effect on the pain was evaluated with 4 point Likert scale 1, 6 and 12 weeks after the procedure. We evaluated the relationship between the pain response to diagnostic block and the pain relief with facet joint denervation. Results: Significant correlation was observed between the response to diagnostic block and pain relief with facet denervation (P < 0.05). We found no correlation between the categories of spinal operation and pain response to facet denervation (P value > 0.05). Conclusions: A satisfactory result of lumbar facet joint denervation can be obtained in many patients, especillay in patients whose pain were relieved by the diagnostic double facet joint block. It may be said that facet joint denervation for mechanical low back pain using radiofrequency thermocoagulation is a safe, easy, and repeatable technique.

  • PDF

Inter-observer reliability in cone-beam computed tomography assessment of the retromolar canal: A practical plan to improve diagnostic imaging

  • Igarashi, Chinami;Theramballi, Yeshoda Ganesh;Kobayashi, Kaoru
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.181-186
    • /
    • 2022
  • Purpose: This study aimed to investigate inter-observer reliability among observers with different levels of proficiency and the diagnostic imaging reliability of cone-beam computed tomography (CBCT) images of the retromolar canal. Materials and Methods: CBCT images of 307 patients were assessed for the presence of retromolar canals(RMCs) by 3 observers independently. Diagnoses were made twice by each observer at intervals of more than 3 weeks. Interobserver reliability was assessed using the kappa coefficient. One observer had no experience in diagnosis using CBCT images. Therefore, a specialist in diagnostic imaging explained the CBCT images for interpretation and practiced diagnostic imaging together with this observer, while the other observer interpreted the images independently. Thereafter, the observers re-evaluated the images. Results: The interobserver kappa coefficients (including bilateral RMCs) calculated at the first reading were low, ranging from 0.21 to 0.61. Their values ranged from 0.95 (right side) to 1.00 (left side) after one-on-one practice with a diagnostic imaging specialist, while the values ranged from 0.65 (right side) to 0.66 (left side) without one-on-one practice. Conclusion: Diagnostic accuracy was improved through diagnostic imaging practice. To improve the anatomical interpretation of images, it is important to practice diagnostic imaging with a specialist in diagnostic imaging. One-on-one instruction about diagnostic imaging was an effective method of training.

Automotive Diagnostic Gateway using Diagnostic over Internet Protocol

  • Lee, Young Seo;Kim, Jin Ho;Jeon, Jae Wook
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.5
    • /
    • pp.313-318
    • /
    • 2014
  • Recently, Ethernet-based Diagnostic Over Internet Protocol (DoIP) was applied to automotive systems, and in-vehicle gateways have been introduced to integrate Ethernet with traditional in-vehicle networks, such as the local interconnect network (LIN), controller area network (CAN) and FlexRay. The introduction of in-vehicle gateways and of Ethernet based diagnostic protocols not only decreases the complexity of the networks, but also reduces the update time for ECU software reprogramming while enabling the use of a range of services, including remote diagnostics. In this paper, a diagnostic gateway was implement for an automotive system, and the performance measurements are presented. In addition, a range of applications provided by the diagnostic gateway are proposed.

Inspection On Sensors of Online Preventive diagnostic system Sensors for Power Transformer (변압기 온라인 예방진단 센서의 점검현황)

  • Koo, Kyo-Sun;Kweon, Dong-Jin;Chin, Sang-Bum;Kwak, Joo-Sik;Kang, Yeon-Woog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.455-460
    • /
    • 2005
  • Preventive diagnostic system for power transformer prevents the sudden power failure through monitoring of abnormal symptoms. KEPCO has adopted the preventive diagnostic system at nine 345kV substations since 1997. Application techniques of the diagnostic sensors were settled, but diagnostic algorithm and practical use of accumulated data are not yet established. To build up the diagnostic algorithm and effective use of the preventive diagnostic system, the reliability of the data accumulated in a server computer is very important. Therefore, this paper describes problem when apply system to substation and solution way to improve reliability of the system

  • PDF

Development of a Diagnostic System for Motor-Operated Valves (모터구동밸브 진단장비 개발)

  • Kang, Seong-Ki;Choi, Hyun-Woo;Park, Sung-Keun;Kang, Shin-Chul;Chai, Jang-Bom
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.420-424
    • /
    • 2008
  • The new MOV(motor-operated valve) diagnostic system MOVIDS(MOV intelligent diagnostic system) was developed. Its remote diagnostic methods with high accuracy have improved the applicability. This enables the diagnostic tests and the evaluations of many MOVs not only at the valves but also in remote places like MCCs(motor control centers). The remote diagnostic ability of the new system reduces the cost and the man power for diagnosing MOVs and eliminates the danger of the toxic or radioactive environments to which workers might be exposed.

  • PDF

Development of the Diagnostic System for the Performance of Air-Operated Valves (공기구동밸브 성능 진단 장비 개발)

  • Kim, Yun-Chul;Kang, Seong-Ki;Park, Sung-Keun;Kim, Dae-Woong;Chai, Jang-Bom
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.416-419
    • /
    • 2008
  • In order to ensure the safety, the performance evaluation of the safety-related components in a nuclear power plant such as air-operated valves. In this paper, the diagnostic system(MOVIDS $A^+$) for the performance of air-operated valves was developed. For this purpose, the characteristics of their operation and the methods of the diagnostic tests were reviewed. The setup and diagnostic functions of the system were mentioned. Its applicability was validated through the diagnostic tests of air-operated valves in nuclear power plants. This diagnostic system is now applied in nuclear power plants for performance tests.

  • PDF