룰 베이스를 이용한 공조기의 고장검출 및 진단 (Fault Detection and Diagnosis of an Air Handling Unit Based on Rule Bases)

  • 한도영;주명재
    • 설비공학논문집
    • /
    • 제14권7호
    • /
    • pp.552-559
    • /
    • 2002
  • The fault detection and diagnosis (FDD) technology may be applied in order to decrease the energy consumption and the maintenance cost of the air conditioning system. In this study, rule bases and curve fitting models were used to detect faults in an air handling unit. Gradually progressed faults, such as the fan speed degradation, the coil water leakage, the humidifier nozzle clogging, the sensor degradation and the damper stoppage, were applied to the developed FBD system. Simulation results show good detections and diagnoses of these faults. Therefore, this method may be effectively used for the fault detection and diagnosis of the air handling unit.

Advanced Indentation Studies on the Effects of Hydrogen Attack on Tensile Property Degradation of Heat-Resistant Steel Heat-Affected Zones

  • Choi, Yeol;Jang, Jae-il;Lee, Yun-Hee;Kwon, Dongil;Kim, Jeong-Tae
    • Corrosion Science and Technology
    • /
    • 제2권6호
    • /
    • pp.266-271
    • /
    • 2003
  • Safety diagnosis of various structural components and facilities is indispensable for preventing catastrophic failure of material by time-dependent and environment accelerating degradation. Also, this diagnosis of operating components should be done periodically for safe maintenance and economical repair. However, conventional standard methods for mechanical properties have the problems of bulky specimen, destructive procedure and complex procedure of specimen sampling. So, a non-destructive and simple mechanical testing method using small specimen is needed. Therefore, an advanced indentation technique was developed as a potential method for non-destructive testing of in-field structures. This technique measures indentation load-depth curve during indentation and analyzes the mechanical properties related to deformation such as yield strength, tensile strength and work-hardening index. In this paper, we characterized the tensile properties including yield and tensile strengths of the V-modified Cr-Mo steels in petro-chemical and thermo-electrical plants. And also, the effects of hydrogen-assisted degradation of the V-modified Cr-Mo steels were analyzed in terms of work-hardening index and yield ratio.

태양광모듈의 성능저하율을 고려한 폐기진단 알고리즘에 관한 연구 (A Study on Disposal Diagnosis Algorithm of PV Modules Considering Performance Degradation Rate)

  • 박지현;이후동;태동현;페레이라 마리토;노대석
    • 한국산학기술학회논문지
    • /
    • 제20권10호
    • /
    • pp.493-502
    • /
    • 2019
  • 최근, 기후변화 및 에너지고갈 등의 문제를 대응하기 위하여, 정부에서 추진하는 재생에너지 3020 정책을 기반으로 태양광전원을 포함한 신재생에너지의 설치가 큰 폭으로 증가되고 있다. 하지만, 설치된 태양광모듈은 주변 환경요인에 따라 다양한 열화현상이 발생하여, 전기적 성능과 수명이 크게 감소될 수 있다. 이러한 문제를 해결하기 위하여, 태양광모듈 판매사업자가 제시한 기대 수명 이전에 새로운 모듈로 교체되는 경우가 증가하고 있다. 따라서, 본 논문에서는 태양광모듈의 성능저하율을 고려하여, 폐기 또는 새로운 모듈로 교체하는 시기를 평가할 수 있는 폐기진단 알고리즘을 제안한다. 또한, 비용요소와 편익요소로 구성된 경제성평가 모델링을 제시하고, 제안한 알고리즘을 바탕으로 태양광모듈의 성능저하율에 따른 경제성을 평가한 결과, 교체하기 전의 태양광모듈의 성능저하율은 3[%]이고, 교체한 경우의 성능저하율은 1[%]인 경우, 설치 후 10년째에 태양광모듈을 교체하는 것이 가장 큰 값(1.347)의 B/C ratio을 가지므로 최적의 경제적인 교체연도임을 알 수 있다. 따라서, 폐기 또는 교체 판별 여부와 어느 시기에 교체하는 것이 가장 경제적인가를 판단할 수 있어, 본 논문에서 제시한 알고리즘의 유용성을 확인하였다.

22.9[kV] 지중배전용 전력케이블의 전기적 특성과 파괴수명 고찰 (The Consideration of Electrical Characteristics and Breakdown Lifetime in 22.9[kV] Underground Distribution Power Cables)

  • 김충배;홍경진;임장섭;정우성;김상준;김태성
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권9호
    • /
    • pp.628-633
    • /
    • 1999
  • Degradation diagnosis of XLPE insulated URD cables was accomplished through out new method, which was to be analyzed by non-electrical experiments and synthesized by degradation points. To supplement this method, It was also carried out using several electrical analyses. Tan$\delta$ had commonly a different tendency by means oftemperature and frequency and also appeared higher at the outer part rather than innerpart of insulator. PD-q increased generally in proportion to the applied voltage andshowed regular patterns in relation to the thickness of insulator. Breakdown voltageswere measured and breakdown lifetimes were predicted appling for Weibull distribution function. As a result, breakdown lifetime in failure cables was shorter up to$\fraction one-third$ times than that in general cables. It was very available to estimate cable degradation using above method, but it needs further study on XLPE insulated URD cables in order to improve reliability.

  • PDF

3d-PD의 통계적 고찰과 신경망 응용기술 (The Application Technique on AI and Statistical Analysis of 3d-PD)

  • 임장섭;박용식;최병하;한석균
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 센서 박막재료
    • /
    • pp.66-70
    • /
    • 2001
  • The partial discharge testing is widely used in diagnostic measuring technology because it gives low stress to power equipment which is undertaken tests. Therefore it is very useful method compare to previous destructive methods and effective diagnosis method in power system that requires on-line/on-site diagnosis. But partial discharges have very complex characteristics of discharge pattern, so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated system is manufactured and HFPD occurred from those simulator is measured with broad-band antenna in real time, the degradation grade of system is analyzed through produced patterns in simulated target according to the AI/statistics processing.

  • PDF

ZnO 바리스터의 등가회로 분석을 통한 DC 열화특성의 향상과 진단 (The Improvement and Diagnosis of DC Degradation Properties with The Equivalent-Circuit Analysis of ZnO Varistors)

  • 소순진;김덕규;김영진;소병문;박춘배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.978-980
    • /
    • 1999
  • In this paper, DC degradation of ZnO varistor sintered in the atmospheres of nitrogen and oxygen was investigated. The content of $SiO_2$ containing 0.0, 0.2, 0.5 mol% respectively was addicted for the improvement of degradation property. ZnO varistor was fabricated in the special electrical furnace which had the vacuum system. The temperature and the voltage for the DC degradation test were $115{\pm}2^{\circ}C$, $0.85V_{1mA/cm^2}$. The time conditions for this test were 0, 2, 4, 8 hours and Current-voltage analysis is used to determine nonlinear coefficients($\alpha$). Frequency analysis are accomplished for the understanding of electrical properties as DC degradation test. In this experiment, We concluded that nonlinear coefficient decreased as the amount of $SiO_2$ addition increased, but degradation rate coefficient increased as the amount of $SiO_2$ addition increased. Also, degradation test with the analysis of equivalent circuit showed that the degradation phenomenon of ZnO varistor wasn't linearity.

  • PDF

적외선방사카메라를 이용한 변압기 온도분포 모니터링 (Temperature Distribution Monitoring of Transformer Using IRR-Camera)

  • 이우선;정찬문;서용진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.459-462
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of Power transformer is measured with partial temperature distribution in real time.

  • PDF

변압기 온도 변화특성 모니터링 (Temperature Distribution Monitoring of Transformer)

  • 이우선;정찬문;손동민;서용진;임장섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of power transformer is measured with partial temperature distribution in real time.

  • PDF

적외선 모니터링 관측의 와이블 분포해석 (The Analysis of Weibull Distribution on the Monitoring of IRR Camera)

  • 임장섭;김진국;이학현;이진;이우선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.264-267
    • /
    • 2004
  • The conventional testing as IEC-60587 is widely used in surface aging measurement of outside insulator those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of out side HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method, But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR Camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis.

  • PDF