• Title/Summary/Keyword: devices of thermometers

Search Result 6, Processing Time 0.022 seconds

Research of Developing of Standards for Electronic Thermometers (전자식체온계 기준규격 개발 연구)

  • Kim, E.J.;Lee, M.J.;Lee, B.Y.;Park, K.G.;Kim, D.S.;Lee, I.S.;Park, H.D.;Jeong, H.K.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.123-128
    • /
    • 2010
  • The thermometers is widely used in diagnostic medical devices, and the safety and accurate performance of these devices are important in the diagnosis and monitoring of personal health. Especially, the accuracy of infra-red thermometer is highly emphasized. Here two typical thermometers are utilized for this purpose: the electronic thermometers measure body temperature by contacting to subject while infra-red thermometers measure by no contacting to subject. Therefore, the evaluating items of each thermometer are different, and the standard for each temperature is highly needed. But, there have been no international standards of each thermometer such as IEC. In this paper, we developed the standards of electronic and infra-red thermometer based on national standards such as KS, ASTM, EN, JIS and FDA guidance. The new standards focused on the safety and suitable performance for health care. This standards were applied to enact and revise the electronic medical device standards. So it can be applied to evaluate the safety and performance on technical file review. We predict that this standard will improve the quality of diagnostic medical devices (thermometers) and increase the international competitive power of domestic product.

Analysis of the Categorization of Wearable devices for Infants and Children by Function, Characteristics, and Improvements (영유아용 웨어러블 디바이스의 기능별 분류, 특성 및 개선점에 대한 분석)

  • Roh, Eui Kyung
    • Fashion & Textile Research Journal
    • /
    • v.23 no.5
    • /
    • pp.655-666
    • /
    • 2021
  • This study aims to classify wearable devices for infants and children according to their function, and to analyze the types and attachment methods of the devices by function, operating system, characteristics of materials, and types of batteries, and to identify the points for improvement. Forty-eight types of devices investigated through previous studies and keyword research online were analyzed. Wearable devices for infants and children were classified according to their functions into wearable monitors, wearable thermometers, GPS trackers, and smart watches. Devices had different shapes and attachment methods according to their functions, and were mainly clothes or accessory types. The accessory type devices were attached to the body using velcro, clips, bands, or adhesives. Wearable monitors and thermometers mainly used Bluetooth to transmit data wirelessly, and location trackers used various combinations of 4G(LTE), 5G networks, GPS, Wi-Fi, and Bluetooth. Smartwatches had different functions depending on whether smart phones were linked to them or not. Wearable monitors and thermometers mainly used by infants provided material information, but other devices did not. These devices used rechargeable, replaceable, non-rechargeable or non-replaceable batteries. Wearable devices need to be improved to reduce the discomfort experienced by infants and children due to the attachment position, malfunction, skin trouble caused by materials, short time of use of batteries, version conflict and complexity with the device when linking with a smart phone, and non-operation when using Bluetooth.

Studies on the Development of Easy-checking Thermometer to Detect the Diseased Domestic Animals with fever (가축 질병 이환상태의 확인을 위한 간이 체온계 개발에 관한 연구)

  • 김용준;한경호;이창민;홍유미
    • Journal of Veterinary Clinics
    • /
    • v.19 no.1
    • /
    • pp.28-36
    • /
    • 2002
  • These studies were carried out to develop some easy-checking thermometers instead of taking temperature of ectum for the farmers to detect easily a diseased animal with fever. Thermometers such as pincher-type, hood-type, raser-type, stick-type, and wrap-type were devised for the experiments. The experimental animals were cattle, horse, swine, aprine, and canine. Temperature-taking parts of the body were ear, shoulder, axilla, gluteal part, and coccygeal part according o the devised thermometer. Rectal temperature was taken at the same time for the comparison of temperature between rectum nd the certain part. The difference of temperature between rectum and shoulder part using eraser-type thermometer for the domestic animals were $3.37^{\circ}C$ for cattle, $1.94^{\circ}C$ for horses, $2.04^{\circ}C$ for swine, $1.27^{\circ}C$ for caprine, $0.9^{\circ}C$ for canine. The difference of temperature between rectum and gluteal part using eraser-type thermometer for domestic animals were $3.46^{\circ}C$ for cattle, $1.98^{\circ}C$ for horses, $2.22^{\circ}C$ for swine, and $1.1^{\circ}C$ for canine. The difference of intra-individual temperature taken by eraser-type thermometer of shoulder and gluteal part were 0.3 and $0.8^{\circ}C$ for cattle, 0.7 and $1.1^{\circ}C$ for horses, 0.6 and $0.7^{\circ}C$ for swine, 0.9 and $1.1^{\circ}C$ for canine. The difference of temperature between rectum and shoulder part taken by hood-type thermometer for cattle was $3.93^{\circ}C$ and the difference of intra-individual temperature was $0.8^{\circ}C$. The difference of temperature between rectum and gluteal part taken by stick-type thermometer for cattle was $3.7^{\circ}C$ and the difference of intra-individual temperature was $0.8^{\circ}C$. The other types of thermometers than the above three were not proved to be reliable to detect temperature of domestic animals. It was concluded that hood-type, stick-type and eraser-type thermometers are recommendable devices of thermometer to detect easily the status of body temperature and that the eraser-type was proved to be a practical one of the thermometers used in this study.

Axillary temperature measurements based on smart wearable thermometers in South Korean children: comparison with tympanic temperature measurements

  • Choi, Younglee;Ahn, Hye Young
    • Child Health Nursing Research
    • /
    • v.28 no.1
    • /
    • pp.62-69
    • /
    • 2022
  • Purpose: This study explored the validity of a new type of thermometer and parent satisfaction with the new device. This 24-hour continuous monitoring smart wearable wireless thermometer (TempTraq®) uses a very small semiconductor sensor with a thin patch-like shape. Methods: We obtained 397 sets of TempTraq® axillary temperatures and tympanic temperatures from 44 pediatric patients. Agreement between the axillary and tympanic measurements, as well as the validity of the TempTraq® axillary temperatures, were evaluated. Satisfaction surveys were completed by 41 caregivers after the measurements. Results: The TempTraq® axillary temperatures demonstrated a strong positive correlation with the tympanic temperatures. The Bland-Altman plot and analysis of TempTraq® axillary temperatures and tympanic temperatures showed that the mean difference was +0.45 ℃, the 95% limits of agreement were -0.57 to +1.46 ℃. Based on a tympanic temperature of 38 ℃, the results of validity of fever detection were sensitivity 0.85 and specificity 0.86. Satisfaction scores for TempTraq® temperature measurement were all > 4 points (satisfactory). Conclusion: TempTraq® smart axillary temperature measurement is an appropriate method for measuring children's temperatures since it was highly correlated to tympanic temperatures, had a reliable level of sensitivity and specificity, and could be used safely and conveniently.

Operation of microcomputer aided convective drying system (마이크로컴퓨터 제어 열풍건조장치의 제작운영)

  • Jeong, Sin-Gyo;Gang, Jun-Su;Choe, Jong-Uk
    • Food Science and Preservation
    • /
    • v.1 no.2
    • /
    • pp.99-105
    • /
    • 1994
  • To convert the analog signal from the drying process into the digital signal, the interface circuit was designed and built. To measure the weight and temperature during drying process, strain gauge type load cell and temperature transducer composed of pt 100 $\Omega$ thermometers and wheatstone bridge circuits were built and used. The temperature control device was composed of photocoupler and triac. Microcomputer aided experimental convective drying system was built with above cricuits and devices. Drying characteristics of onions can be estimated using this system.

  • PDF

ENVIROMENTAL CONDITION DURING AIR SHIPMENT OF HORTICULTURAL PRODUCTS FROM OKINAWA TO TOKYO

  • Akinaga, Takayoshi;Kohda, Yoshihiro
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.413-422
    • /
    • 1993
  • Air shipment affords the quickest possible delivery of horticultural products. The price of air shipped horticultural products are relatively high as most of these products are perishable. Usually the temperature in the cargo compartment is not controlled during flight. Thus, special attention should be paid to procooling prior to shipment. The environmental condition during transportation of horticultural products is an essential parameter for maintaining the quality of perishable products. Commonly horticultural products were loaded by ULD(Unit Load Devices) as a container or pallet in the aircraft (except for small aircraft) . Therefore, inside temperature of the container and cargo compartment came into question. Scarce literature on the relationship between environmental condition and quality changes of horticultural products during air shipment can be found. By the stand point of keeping fresh quality, investigations on the actual condition of air shipments were carried out to improve the technique during the distribution process of fresh horticultural products. Temperature, humidity, atmospheric pressure, carbon dioxide, ethylene, impacts, and changes in quality during the air shipment of snapbeans, okras and chrysanthemums were measured. Temperature was measured by recording thermometers, relative humidity by recording hygrometers, atmospheric pressure by a strain -guage type pressure sensor, carbon dioxide by testing tubes, ethylene by sampling bags and a gaschromatograph, impacts and vibrations by impact recorders and a 3D accelerometer. Relationships between environmental conditions and quality changes during air shipments were clarified. It was expected from investigations into actual shipments that the ventilation and insulation properties of air freight containers were related to the quality of agricultural products. Aircraft can no directly load and unload trucks into them. The transshipment is inclined to cause shocks and vibrations, and to invite damages within a short time.

  • PDF