• Title/Summary/Keyword: device-free system

Search Result 231, Processing Time 0.025 seconds

Design of the u-Service System for Silver Towns (실버타운을 위한 u-서비스 시스템의 설계)

  • Choi, Yeon-Suk;Park, Byoung-Tae;Choi, Yong-Ju
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.04a
    • /
    • pp.127-135
    • /
    • 2010
  • In this paper, the u-Service system that is based on location-aware technology is designed for a silver town. It provides services such as emergency call, intelligent elevator operation, and hands-free door access based on the location of the residents with personal device as called smart tag. It can also be applied to other service areas such as the location-aware u-Service for Hospital, high-rising complex building, APT, etc.

  • PDF

Automatic Automobile Control System with Multi-Sensor (다중센서를 이용한 무인자동차 제어시스템)

  • Han, Chang-Woo;Choi, Won-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.4 no.3
    • /
    • pp.339-347
    • /
    • 2001
  • Automatic automobile has been studied as the alternative energy system and the production flow automation device recently. But this is dependent on the import production, and its position cannot be controlled free from the fixed path. It is difficult to control the automobile position because of the eccentricity of inertia monent, slip and roughness between wheel and road surface. This problems is solved for the controller to be feedbacked the data of the multi-sensor system consisting of the rotary encoder and electronic compass. The proportional Integrated controller in the modified Ziegler-Nichols method is made up with Hitachi 7034 microprocessor. To the real time control the mechanical, electrical and electronic hardware and software device is produced by myself. The RF data of automobile speed and position is supplied to the remote PC to be displayed the automobile condition. By the experinent of the forward, spin, point path planning, it is known for autombile.

  • PDF

Electromagnetic Resonant Tunneling System: Double-Magnetic Barriers

  • Kim, Nammee
    • Applied Science and Convergence Technology
    • /
    • v.23 no.3
    • /
    • pp.128-133
    • /
    • 2014
  • We study the ballistic spin transport properties in a two-dimensional electron gas system in the presence of magnetic barriers using a transfer matrix method. We concentrate on the size-effect of the magnetic barriers parallel to a two-dimensional electron gas plane. We calculate the transmission probability of the ballistic spin transport in the magnetic barrier structure while varying the width of the magnetic barriers. It is shown that resonant tunneling oscillation is affected by the width and height of the magnetic barriers sensitively as well as by the inter-spacing of the barriers. We also consider the effect of additional electrostatic modulation on the top of the magnetic barriers, which could enhance the current spin polarization. Because all-semiconductor-based devices are free from the resistance mismatch problem, a resonant tunneling structure using the two-dimensional electron gas system with electric-magnetic modulation would play an important role in future spintronics applications. From the results here, we provide information on the physical parameters of a device to produce well-defined spin-polarized current.

A Study on the Free Surface Vortex in the Pipe System (배관내 자유수면에서 와류현상에 대한 연구)

  • Kim, Sang-Nyung;Jang, Wan-Ho
    • Nuclear Engineering and Technology
    • /
    • v.24 no.3
    • /
    • pp.311-318
    • /
    • 1992
  • During mid-loop operation of Nuclear Power Plant, to prevent the Decay Heat Removal System (DHRS) from failure due to air entrainment of free surface vortex in the piping system, a set of simulating experiments was performed. Through these experiments, a relation between the non-dimensionalized numbers, such as H/d, Froude number, Reynolds number, was found. It was also found that the perturbation of the system by the disturbance such as pump start, valve operation, etc., has a strong effect on the free surface vortex. Furthermore, from viewpoint of reactor safety, a modified inlet device which is reducer type is strongly recommended for the prevention of air entrainment into DHRS.

  • PDF

Development of a Breath Control Training System for Breath-Hold Techniques and Respiratory-Gated Radiation Therapy

  • Hyung Jin Choun;Jung-in Kim;Jong Min Park;Jaeman Son
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.136-141
    • /
    • 2022
  • Purpose: This study aimed to develop a breath control training system for breath-hold technique and respiratory-gated radiation therapy wherein the patients can learn breath-hold techniques in their convenient environment. Methods: The breath control training system comprises a sensor device and software. The sensor device uses a loadcell sensor and an adjustable strap around the chest to acquire respiratory signals. The device connects via Bluetooth to a computer where the software is installed. The software visualizes the respiratory signal in near real-time with a graph. The developed system can signal patients through visual (software), auditory (buzzer), and tactile (vibrator) stimulation when breath-holding starts. A motion phantom was used to test the basic functions of the developed breath control training system. The relative standard deviation of the maxima of the emulated free breathing data was calculated. Moreover, a relative standard deviation of a breath-holding region was calculated for the simulated breath-holding data. Results: The average force of the maxima was 487.71 N, and the relative standard deviation was 4.8%, while the average force of the breath hold region was 398.5 N, and the relative standard deviation was 1.8%. The data acquired through the sensor was consistent with the motion created by the motion phantom. Conclusions: We have developed a breath control training system comprising a sensor device and software that allow patients to learn breath-hold techniques in their convenient environment.

User Experience Evaluation of Augmented Reality based Guidance Systems for Solving Rubik's Cube using HMD (HMD를 이용한 증강현실 큐브 맞추기 안내 시스템의 사용자 경험 평가)

  • Park, Jaebum;Park, Changhoon
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.7
    • /
    • pp.935-944
    • /
    • 2017
  • As augmented reality technology has developed, various augmented reality contents can be seen in real life, and the performance of mobile device is improved, so augmented reality technology can be used even without special device. As a result, a training system, guidance system and a museum art guide system based on augmented reality technology are emerging, and interest in augmented reality is also increasing. However, the existing guidance systems using a single mobile device have limitations in terms of the user experience (UX) because the camera of the device limits the field of view or the two hands are not free and the user input is difficult. In this paper, we compare augmented reality based guidance systems for Rubik's Cube using tablet and HMD to improve the constraint of user experience of such a single mobile device, and find elements that positively improve user experience. After that, we evaluate whether the user experience is actually improved through the user experience comparison test and the questionnaire.

Vascular Remodeling with a Microvascular Anastomotic Coupler System: A Case Report

  • Hong, Changbae;Yeo, Hyeonjung;Son, Daegu
    • Archives of Reconstructive Microsurgery
    • /
    • v.24 no.1
    • /
    • pp.20-23
    • /
    • 2015
  • Despite increased utilization of microvascular anastomotic coupler (MAC) devices, the consequences have yet to be fully explored in terms of vascular regeneration. Removal of an exposed venous coupler is described herein, documenting normal circulatory flow through the remodeled site of application. A 25-year-old man who underwent open reduction and rigid fixation elsewhere for traumatic calcaneal fracture ultimately presented with a necrotic postoperative wound. The debrided defect was treated by free thigh perforator flap, incorporating a MAC device. Three months later, the flap remained viable, but the MAC itself was exposed. Structural integrity of the vessel and blood flow were sustained as the device was carefully removed, confirming true vascular remodeling in this example of MAC usage.

Development of Automatic Hole Position Measurement System using the CCD-camera (CCD-카메라를 이용한 홀 변위 자동측정시스템 개발)

  • 김병규;최재영;강희준;노영식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.127-130
    • /
    • 2004
  • For the quality control of the industrial products, an automatic hole measuring system has been developed. The measurement device allows X-Y movement due to contact forces between a hole and its own circular cone and the device is attached to an industrial robot. Its measurement accuracy is about 0.04mm. This movement of the plate is measured by two LVDT sensor system. But this system using the LVDT sensors is restricted by high cost and precision of measurement and correspondence of environment so particularly, a vision system with CCD-Camera is discussed in this paper for the above mentioned purpose. The device consists of two of two links jointed with hinge pins basically and, they guarantee free movement of the touch prove attached on the second link in the same plane. These links are returned to home position by the spring plungers automatically after each process for the next one. On the surface of the touch prove, it has a circular white mark for camera recognition. The system detect and notify the center coordinate of capture mark image through the image processing. Its measuring accuracy has been proved to be about $\pm$0.01mm through the repeated implementation over 200 times. This technique will shows the advantage of touch-indirect image capture idea using cone-shaped touch prove in various symmetrical shaped holes particulary, like tapped holes, chamfered holes, etc As a result, we attained our object in a view of the accuracy, economical efficiency, and functionality

  • PDF

A Study on the Design of the Free-Piston Stirling Engine/Alternator (자유 피스톤 스털링엔진/발전기의 설계 인자 연구)

  • Park, Seongje;Hong, Yongju;Ko, Junseok;Kim, Hyobong;Yeom, Hankil;In, Sehwan;Kang, Insu;Lee, Cheongsu
    • Journal of Hydrogen and New Energy
    • /
    • v.25 no.6
    • /
    • pp.648-655
    • /
    • 2014
  • This paper describes the continuing effort to develope a single acting free-piston Stirling engine/alternator combination for use of the household cogeneration. Free piston Stirling engines(FPSE) use variations of working gas pressure to drive mechanically unconstrained reciprocating elements. Stirling cycle free-piston engines are driven by the Stirling thermodynamic cycle which is characterized by an externally heated device containing working gas that is continuously re-used in a regenerative, reversible cycle. The ideal cycle is described by two isothermal process connected by two constant volume processes. Heat removed during the constant volume cooling process is internally transferred to the constant volume heating process by mutual use of a thermal storage medium called the regenerator. Since the ideal cycle is reversible, the ideal efficiency is that of Carnot. Free-piston Stirling engine is have no crank and rotating parts to generate lateral forces and require lubrication. The FPSE is typically comprised of two oscillating pistons contained in a common cylinder. The temperature difference across the displacer maintains the oscillations, and the FPSE operate at natural frequency of the mass-spring system. The power is generated from a linear alternator. The purpose of this paper is to describe the design process of the single acting free-piston Stirling engine/alternator. Electrical output of the single acting free-piston Stirling engine/alternator is about 0.95 kW.

A Study of the design method for Interactive squat exercise Instrument (인터렉티브 스쿼트운동기구의 설계방법에 관한 연구)

  • Jeong, Byeong-Ho;Park, Ju-Hoon;Kim, Ji-won
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.2
    • /
    • pp.303-311
    • /
    • 2018
  • Squat exercise is one of the free weight exercises that are recognized as important from a bio-mechanical point of view. It is an important exercise to train lower extremity muscles in daily activities or sports activities and to strengthen trunk and lower body strength. It is effective and accurate to use a variety of assistive devices to calibrate athletic posture with squat exercise supported interactive device. The issues of the structural analysis for design a foot plate for squat exercise is to model the behavior by simplifying the dynamic behavior. In this paper, the authors proposed a exercise system design method for the vertical load distribution and bio-mechanical signal process used for the squat exercise mechanism analysis, and based on these results, designed device can make the more safe and reliable free weight exercise. It is applied to system design through design method with kinematic dynamic, VR device and estimation model of exercise.