• 제목/요약/키워드: device attachment

검색결과 112건 처리시간 0.033초

접촉식 변위센서를 이용한 홀 변위 측정 로봇시스템 개발 (Development of a Robotic System for Measuring Hole Displacement Using Contact-Type Displacement Sensors)

  • 강희준;권민호;서영수;노영식
    • 한국정밀공학회지
    • /
    • 제25권1호
    • /
    • pp.79-84
    • /
    • 2008
  • For the precision measurement of industrial products, the location of holes inside the products, if they exist, are often selected as feature points. The measurement of hole location would be performed by vision and laser-vision sensor. However, the usage of those sensors is limited in case of big change of light intensity and reflective shiny surface of the products. In order to overcome the difficulties, we have developed a hole displacement measuring device using contact-type displacement sensors (LVDTs). The developed measurement device attached to a robot measures small displacement of a hole by allowing its X-Y movement due to the contact forces between the hole and its own circular cone. The developed device consists of three plates which are connected in series for its own function. The first plate is used for the attachment to an industrial robot with ball-bush joints and springs. The second and third plates allow X-Y direction as LM guides. The bottom of the third plate is designed that various circular cones can be easily attached according to the shape of the hole. The developed system was implemented for its effectiveness that its measurement accuracy is less than 0.05mm.

성인성 치주질환에서 미노클린 국소송달제 효과에 대한 연구 (The Clinical and Microbiological Study of the Effect of Minocycline Strip Locally Administrated on Adult Periodontitis)

  • 최성호;현석주;구현서;서종진;조규성;채중규;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제28권2호
    • /
    • pp.193-203
    • /
    • 1998
  • 20 Subjects with clinical diagnosis of adult periodontitis with sites having average pocket depth of 4mm were selected for the study. After scaling and root planing of those sites, 30% minocycline-HCI contained in biodegradable device were inserted in one group, scaling and root planing was carried out in another group and the last group was without any periodontal treatment. the difference between the group was detemined by pocket dept, bleeding on prbing, attachment level, distribution of subgingval plaque bacteria. Conclusion was made for the comparisons between baseline and 4 week and the groups. 1. In analysis of pocket depth, there was significant sifference in scaling and root planing group only. 2. Both the scaling and root planing group and minocycline group showed significant decrease in bleeding on probing. 3. There was significant increase in the attachment level in scaling and root planing group, but no difference was foundbetween the groups. 4. There was significant decrease in the total number of subgingival bacteria in all groups and the number of motile bacteria decreased significantly in the minocycline group. These result indicate that insertion of Minocycline-HCI at the base of periodntal pocket was useful as an additional aid of mechanical trarment at the point of periodontal pocket, bleeding on probing, attachment level, microbial distribution.

  • PDF

특정 대상에 대한 개인 수준의 문화적 성향이 사용자 경험에 미치는 조절효과에 대한 실증적 연구: 미국, 독일, 러시아의 4개 디지털 기기 사용자를 대상으로 (An Empirical Study on How the Moderating Effects of Individual Cultural Characteristics towards a Specific Target Affects User Experience: Based on the Survey Results of Four Types of Digital Device Users in the US, Germany, and Russia)

  • 이인성;최지웅;김소령;이기호;김진우
    • Asia pacific journal of information systems
    • /
    • 제19권1호
    • /
    • pp.113-145
    • /
    • 2009
  • Recently, due to the globalization of the IT(Information Technology) market, devices and systems designed in one country are used in other countries as well. This phenomenon is becoming the key factor for increased interest on cross-cultural, or cross-national, research within the IT area. However, as the IT market is becoming bigger and more globalized, a great number of IT practitioners are having difficulty in designing and developing devices or systems which can provide optimal experience. This is because not only tangible factors such as language and a country's economic or industrial power affect the user experience of a certain device or system but also invisible and intangible factors as well. Among such invisible and intangible factors, the cultural characteristics of users from different countries may affect the user experience of certain devices or systems because cultural characteristics affect how they understand and interpret the devices or systems. In other words, when users evaluate the quality of overall user experience, the cultural characteristics of each user act as a perceptual lens that leads the user to focus on a certain elements of experience. Therefore, there is a need within the IT field to consider cultural characteristics when designing or developing certain devices or systems and plan a strategy for localization. In such an environment, existing IS studies identify the culture with the country, emphasize the importance of culture in a national level perspective, and hypothesize that users within the same country have same cultural characteristics. Under such assumptions, these studies focus on the moderating effects of cultural characteristics on a national level within a certain theoretical framework. This has already been suggested by cross-cultural studies conducted by scholars such as Hofstede(1980) in providing numerical research results and measurement items for cultural characteristics and using such results or items as they increase the efficiency of studies. However, such national level culture has its limitations in forecasting and explaining individual-level behaviors such as voluntary device or system usage. This is because individual cultural characteristics are the outcome of not only the national culture but also the culture of a race, company, local area, family, and other groups that are formulated through interaction within the group. Therefore, national or nationally dominant cultural characteristics may have its limitations in forecasting and explaining the cultural characteristics of an individual. Moreover, past studies in psychology suggest a possibility that there exist different cultural characteristics within a single individual depending on the subject being measured or its context. For example, in relation to individual vs. collective characteristics, which is one of the major cultural characteristics, an individual may show collectivistic characteristics when he or she is with family or friends but show individualistic characteristics in his or her workplace. Therefore, this study acknowledged such limitations of past studies and conducted a research within the framework of 'theoretically integrated model of user satisfaction and emotional attachment', which was developed through a former study, on how the effects of different experience elements on emotional attachment or user satisfaction are differentiated depending on the individual cultural characteristics related to a system or device usage. In order to do this, this study hypothesized the moderating effects of four cultural dimensions (uncertainty avoidance, individualism vs, collectivism, masculinity vs. femininity, and power distance) as suggested by Hofstede(1980) within the theoretically integrated model of emotional attachment and user satisfaction. Statistical tests were then implemented on these moderating effects through conducting surveys with users of four digital devices (mobile phone, MP3 player, LCD TV, and refrigerator) in three countries (US, Germany, and Russia). In order to explain and forecast the behavior of personal device or system users, individual cultural characteristics must be measured, and depending on the target device or system, measurements must be measured independently. Through this suggestion, this study hopes to provide new and useful perspectives for future IS research.

Ergonomic Design of Necklace Type Wearable Device

  • Lee, Jinsil;Ban, Kimin;Choe, Jaeho;Jung, Eui S.
    • 대한인간공학회지
    • /
    • 제36권4호
    • /
    • pp.281-292
    • /
    • 2017
  • Objective: This study aims to identify important physical design variables in designing a necklace type wearable device, and to present design guidelines to maximize comfort that a user feels upon wearing the device. Background: Interests in fitness culture and personal health are on the rise recently. In such a situation, demand for necklace type wearable devices is projected to increase a lot, as the devices enable users to use their hands freely and to enjoy various contents through connection with mobile devices. However, the necklace type wearable device's comfort was assessed to have the lowest comfort in a running situation, where human body moves up and down and left and right more than other devices wearable on other human body parts. Therefore, the usability of a necklace type wearable device was low. In this regard, studies on identification of the variables affecting user comfort upon wearing a necklace type wearable device and on physical design direction maximizing comfort and usability are needed. Method: A pretest and a main test were carried out to draw the direction of necklace type wearable device design. In the pretest, wearing evaluation on the diverse types of devices released in the market was conducted to draw physical design variables of the devices affecting comfort. Furthermore, variables significantly affecting the comfort of a device were selected through an analysis of variance (ANOVA). In the main test, anthropometry was performed, and information on anthropometric items corresponding to the design variables selected in the pretest was acquired. Based on the pretest results and the anthropometric information in the main test, the present study produced design guidelines maximizing the comfort of a necklace type wearable device with regard to major design variables upon dynamic tasks. Results: According to the pretest results, the variables having effects on comfort were the angle of side points, width, and height. Due to interactions between variables, those need to be simultaneously considered upon designing a device. Upon dynamic tasks, the angle of side points and width of a device was designed to be smaller than mean angle of the trapezius muscle and neck width, and thus attachment to human body was high. As height was designed to be larger than mean neck front and rear point width, comfort was higher due to feeling of stability. Conclusion: Because user sensitivity to comfort was high at human body's inflection points, a device needs to be designed for users not to feel high pressure on specific body parts with the device fitting human body shape well. A design considering user's situation is also required in further studies.

의복형 초소형 발광모듈을 이용한 신경근육 자극 시스템 개발 및 임상적 효과 검증 (Development of Neuromuscular Stimulus System using Wearable Ultra-miniature Lighting Modules and its Verification of Clinical Effectiveness)

  • 박세형;이종실;김인영;김선일
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권1호
    • /
    • pp.23-33
    • /
    • 2009
  • It can be used easily to reduce rehabilitation and treatment time if diagnostic and therapeutic devices are attached to cloth or body. Therefore we developed neuromuscular wearable ultra-miniature lighting modules which can improve the neuromuscular function and verified its clinical effectiveness. The system is based on the ultra-miniature lighting treatment module and there are two types of systems. One of them is designed as an attached type and the other type is combined with clothing. The wearable ultra-miniature lighting module is composed of controller (battery, MCU, bidirectional transmitter and receiver), cable, treatment medium generating device and other peripheral devices. To verify the clinical effectiveness of this device, we observed the difference of the strength of a muscle before and after 650nm and 25mW laser irradiation on the reflex point for 1 to 4 seconds. Among 48 patients having the degenerative osteoarthritis, the muscle strength before and after irradiation of laser was $21.8{\pm}7.99$ and $27.3{\pm}8.43$. According to the result, the muscle strength after treatment was significantly increased (p<0.01). To whom having difficulty in visiting to OPD(Out-Patient Department), doctors medically examine the patients and find the therapeutic point, attachment of this wearable ultra-miniature lighting module can function as self treatment (treating instrument) and treatment assist at home. If doctor can remotely control the patient and take part in treatment, the therapeutic device could contribute to prevention and care device.

패치형 웨어러블 심전도 측정 시스템을 위한 접착성 폴리우레탄 기반의 용량성 전극 (Adhesive Polyurethane-based Capacitive Electrode for Patch-type Wearable Electrocardiogram Measurement System)

  • 이정수;이원규;임용규;박광석
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권6호
    • /
    • pp.203-210
    • /
    • 2014
  • Wearable medical device has been a resurgence of interest thanks to the development of technology and propagation of smart phone in recent years. Various types of wearable devices have been introduced and available in market. Capacitive coupled electrode which measures electrocardiogram over cloth is able to be applied wearable device. In previous approaches of capacitive electrode, they need proper pressure for stable contact of the electrode to body surface. However, wearable device that gives pressure on body surface is not suitable for long-term monitoring. In this study, we proposed adhesive polyurethane-based capacitive electrode for patch-type wearable electrocardiogram (ECG) monitoring device. Self-adhesive polyurethane make the electrode and whole system be adhered to the surface of skin without any pressure. The patch-type system is consisted of analog filter, analog-to-digital converter and wireless transmission module and designed to be attached on the body as a patch. To validate the feasibility of the developed system, we measured ECG signal in stable and active state and extracted heart rate. Therefore, we observed skin response after long-term attachment for biocompatibility of the adhesive polyurethane and adhesive strength of it. The result shows the possibility of applying the developed system for ECG monitoring in real-life.

깡충거미 표면 접착장치의 미세구조 분석 (Fine Structural Analysis of the Attachment Devices in the Jumping Spider Plexippus setipes)

  • 문명진;박종구
    • Applied Microscopy
    • /
    • 제39권2호
    • /
    • pp.149-156
    • /
    • 2009
  • 거미의 외골격은 그 특성상 소수성이며 접착성이 없는 구조를 지니고 있지만, 일부 배회성 거미들은 부드럽고 건조한 표면을 따라 보행할 수 있는 독특한 접착장치를 지니고 있다. 본 연구는 거미류 접착보행 장치의 미세구조적 특성을 규명하기 위하여 깡충거미과의 세발깡충거미 (Plexippus setipes)를 실험재료로 하여 4쌍의 보행지에 형성된 접착장치를 고배율의 주사전자현미경으로 관찰하였다. 그 결과, 각각의 보행지에서 2개의 발톱(claw)과 강모다발 (scopula)이 관찰되었는데, 건조한 표면에 대한 부착력은 강모다발의 특이한 구조로부터 발생됨이 확인되었다. 각 보행지마다 약 160개의 강모 (seta)가 관찰되었는데, 표면과 접촉을 이루는 방향에 따라 두 집단의 강모다발로 구분되었다. 강모의 배면을 따라 형성된 무수한 감각모로 인해 인접 강모들과의 접착이 차단되어 있었고, 강모의 복면에서는 고밀도로 밀집된 미세강모 (setule)들이 관찰되었다. 미세강모의 첨단부는 역삼각형의 주걱모양으로 펼쳐져 충분한 접촉면을 확보하고 있었으며, 미세강모의 유연성과 그 표면에 형성된 큐티클 함몰부의 미세구조 등이 깡충거미류 부착장치의 특성임을 확인할 수 있었다.

돈사 적용용 DC전압을 이용한 오존발생장치 개발에 관한 연구 (Development of Ozone Generator with using DC Voltage for Swinery)

  • 문승일;채재우;이대엽;장기현;정태균
    • 한국대기환경학회지
    • /
    • 제19권1호
    • /
    • pp.77-84
    • /
    • 2003
  • HS, Ammonia, CH$_4$, VOCs, Microorganism, Bacteria etc produced from swineries or henhouses are known to prevent the growth of livestock. Moreover, they give an unpleasant feeling to the workers. In this study, a methodology to remove odors and toxic gases by oxidation of ozone was thus accomplished. However, most ozone generators which use the atmospheric surrounding air have problems of contamination of electrode for discharge. Therefore in this work, a wire-cylinder type plasma reactor with DC voltage has been used both in a laboratory scale test and in the real swinery to solve the existing problems. About 6 cm of electrode gap could decrease the attachment of dusts, humid aerosols and other polymers, which are contained in the air. This compact designed device could produce ozone to oxidize and remove the air pollutants. But the amount of ozone was not large enough to be harmful to human Health. Also, the concentration of ozone was able to be varied by the input voltage. which makes it available for the proposed system to be installed in various kinds of pig houses. With this device, at maximum 43 mg/㎥ (20 ppm) of ozone could be produced at 40 ㎸ input voltage (consumed energy was 0.1 Wh/㎥). A program was also made in this work to calculate the optimum parameters for design of a plasma reactor in wide range of conditions.

아연 이온화 장치에 의한 상수배관 내 스케일 및 녹 생성 억제효과 실증 연구 (Empirical study on inhibition effect of scale and rust in tap-water line by zinc ionization device)

  • 염경택;최정욱;양성봉;심학섭;유미선
    • 상하수도학회지
    • /
    • 제35권6호
    • /
    • pp.465-476
    • /
    • 2021
  • Scale and rust generation in water pipes is a common phenomenon when cast iron water pipes have been used for a long time. A physical water treatment device is known among various means for suppressing rust in a water pipe, and a zinc ionization device for putting zinc metal into a pipe and emitting the zinc cation into water is one of such devices. This research measured the amount of zinc ion generated, which is known to exhibit an effect of inhibiting rust and scale generation in a pipe, and examined the scale and rust inhibition effect of the ionization device installed for ground or building water supply. In the case of distilled water, the concentration of zinc ion increased by circulating water in the ionization device several times, and it was verified to be hundreds of ㎍/L, and in the case of discharging ground or tap water, it was verified to be tens of ㎍/L. In addition, a verification pipe was installed to confirm the change inside the pipe before and after installation of the zinc ionization device, and the internal condition of the pipe was observed 3 months to several years after installation. It was confirmed that the corrosion area of the surface of the pipe was no longer increased by installing a corrosion inhibitor, and if the pipe was already filled with corrosion products, the amount of corrosion products gradually decreased every year after installation. The phenomenon of fewer corrosion products could be interpreted as expanding the space in the pipe due to the corrosion product as Fe2O3 adhered to the inner surface of the pipe and turned into a smaller black Fe3O4. In addition, we found that scale such as CaCO3 together in the corrosion by-products gradually decreased with the attachment of the ionization device.

Stability-Enhanced Liquid Crystal Mode for Flexible Display Applications

  • Jung, Jong-Wook;Jang, Se-Jin;Lee, You-Jin;Kim, Hak-Rin;Jin, Min-Young;Kim, Jae-Hoon
    • Journal of Information Display
    • /
    • 제6권2호
    • /
    • pp.1-6
    • /
    • 2005
  • We demonstrated stability-enhanced liquid crystal (LC) displays using pixel-isolated LC mode in which LC molecules are isolated in pixel by horizontal polymer layer and vertical polymer wall. The device shows good electro-optic properties against external point or bending pressure due to the polymer structures. The polymer wall acts as supporting structure from mechanical pressure and prevents the cell gap from bending. Moreover, the polymer layer acts as an adhesive to ensure a tight attachment of the two substrates. We present herein various methods for producing polymer structures by using an anisotropic phase separation from LC and polymer composites or patterned micro-structures for stable flexible liquid crystal displays.