• Title/Summary/Keyword: deviation ratio

Search Result 925, Processing Time 0.028 seconds

Utility of intraoral scanner imaging for dental plaque detection

  • Chihiro Yoshiga;Kazuya Doi;Hiroshi Oue;Reiko Kobatake;Maiko Kawagoe;Hanako Umehara;Kazuhiro Tsuga
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.43-48
    • /
    • 2024
  • Purpose: Oral hygiene, maintained through plaque control, helps prevent periodontal disease and dental caries. This study was conducted to examine the accuracy of plaque detection with an intraoral scanner(IOS) compared to images captured with an optical camera. Materials and Methods: To examine the effect of color tone, artificial tooth resin samples were stained red, blue, and green, after which images were acquired with a digital single-lens reflex (DSLR) camera and an IOS device. Stained surface ratios were then determined and compared. Additionally, the deviation rate of the IOS relative to the DSLR camera was computed for each color. In the clinical study, following plaque staining with red disclosing solution, the staining was captured by the DSLR and IOS devices, and the stained area on each image was measured. Results: The stained surface ratios did not differ significantly between DSLR and IOS images for any color group. Additionally, the deviation rate did not vary significantly across colors. In the clinical test, the stained plaque appeared slightly lighter in color, and the delineation of the stained areas less distinct, on the IOS compared to the DSLR images. However, the stained surface ratio was significantly higher in the IOS than in the DSLR group. Conclusion: When employing IOS with dental plaque staining, the impact of color was minimal, suggesting that the traditional red stain remains suitable for plaque detection. IOS images appeared relatively blurred and enlarged relative to the true state of the teeth, due to inferior sharpness compared to camera images.

Evaluation of Setup Uncertainty on the CTV Dose and Setup Margin Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 셋업오차가 임상표적체적에 전달되는 선량과 셋업마진에 대하여 미치는 영향 평가)

  • Cho, Il-Sung;Kwark, Jung-Won;Cho, Byung-Chul;Kim, Jong-Hoon;Ahn, Seung-Do;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.81-90
    • /
    • 2012
  • The effect of setup uncertainties on CTV dose and the correlation between setup uncertainties and setup margin were evaluated by Monte Carlo based numerical simulation. Patient specific information of IMRT treatment plan for rectal cancer designed on the VARIAN Eclipse planning system was utilized for the Monte Carlo simulation program including the planned dose distribution and tumor volume information of a rectal cancer patient. The simulation program was developed for the purpose of the study on Linux environment using open source packages, GNU C++ and ROOT data analysis framework. All misalignments of patient setup were assumed to follow the central limit theorem. Thus systematic and random errors were generated according to the gaussian statistics with a given standard deviation as simulation input parameter. After the setup error simulations, the change of dose in CTV volume was analyzed with the simulation result. In order to verify the conventional margin recipe, the correlation between setup error and setup margin was compared with the margin formula developed on three dimensional conformal radiation therapy. The simulation was performed total 2,000 times for each simulation input of systematic and random errors independently. The size of standard deviation for generating patient setup errors was changed from 1 mm to 10 mm with 1 mm step. In case for the systematic error the minimum dose on CTV $D_{min}^{stat{\cdot}}$ was decreased from 100.4 to 72.50% and the mean dose $\bar{D}_{syst{\cdot}}$ was decreased from 100.45% to 97.88%. However the standard deviation of dose distribution in CTV volume was increased from 0.02% to 3.33%. The effect of random error gave the same result of a reduction of mean and minimum dose to CTV volume. It was found that the minimum dose on CTV volume $D_{min}^{rand{\cdot}}$ was reduced from 100.45% to 94.80% and the mean dose to CTV $\bar{D}_{rand{\cdot}}$ was decreased from 100.46% to 97.87%. Like systematic error, the standard deviation of CTV dose ${\Delta}D_{rand}$ was increased from 0.01% to 0.63%. After calculating a size of margin for each systematic and random error the "population ratio" was introduced and applied to verify margin recipe. It was found that the conventional margin formula satisfy margin object on IMRT treatment for rectal cancer. It is considered that the developed Monte-carlo based simulation program might be useful to study for patient setup error and dose coverage in CTV volume due to variations of margin size and setup error.

Study on the Difference in Intake Rate by Kidney in Accordance with whether the Bladder is Shielded and Injection method in 99mTc-DMSA Renal Scan for Infants (소아 99mTc-DMSA renal scan에서 방광차폐유무와 방사성동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구)

  • Park, Jeong Kyun;Cha, Jae Hoon;Kim, Kwang Hyun;An, Jong Ki;Hong, Da Young;Seong, Hyo Jin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.27-31
    • /
    • 2016
  • Purpose $^{99m}Tc-DMSA$ renal scan is a test for the comparison of the function by imaging the parenchyma of the kidneys by the cortex of a kidney and by computing the intake ratio of radiation by the left and right kidney. Since the distance between the kidneys and the bladder is not far given the bodily structure of an infant, the bladder is included in the examination domain. Research was carried out with the presumption that counts of bladder would impart an influence on the kidneys at the time of this renal scan. In consideration of the special feature that only a trace amount of a RI is injected in a pediatric examination, research on the method of injection was also carried out concurrently. Materials and Methods With 34 infants aged between 1 month to 12 months for whom a $^{99m}Tc-DMSA$ renal scan was implemented on the subjects, a Post IMAGE was acquired in accordance with the test time after having injected the same quantity of DMSA of 0.5mCi. Then, after having acquired an additional image by shielding the bladder by using a circular lead plate for comparison purposes, a comparison was made by illustrating the percentile of (Lt. Kidney counts + Rt. Kidney counts)/ Total counts, by drawing the same sized ROI (length of 55.2mm X width of 70.0mm). In addition, in the format of a 3-way stopcock, a Heparin cap and direct injection into the patient were performed in accordance with RI injection methods. The differences in the count changes in accordance with each of the methods were compared by injecting an additional 2cc of saline into the 3-way stopcock and Heparin cap. Results The image prior to shielding of the bladder displayed a kidney intake rate with a deviation of $70.9{\pm}3.18%$ while the image after the shielding of the bladder displayed a kidney intake rate with a deviation of $79.4{\pm}5.19%$, thereby showing approximately 6.5~8.5% of difference. In terms of the injection method, the method that used the 3-way form, a deviation of $68.9{\pm}2.80%$ prior to the shielding and a deviation of $78.1{\pm}5.14%$ after the shielding were displayed. In the method of using a Heparin cap, a deviation of $71.3{\pm}5.14%$ prior to the shielding and a deviation of $79.8{\pm}3.26%$ after the shielding were displayed. Lastly, in the method of direct injection into the patient, a deviation of $75.1{\pm}4.30%$ prior to the shielding and a deviation of $82.1{\pm}2.35%$ after the shielding were displayed, thereby illustrating differences in the kidney intake rates in the order of direct injection, a Heparin cap and the 3-way methods. Conclusion Since a substantially minute quantity of radiopharmaceuticals is injected for infants in comparison to adults, the cases of having shielded the bladder by removing radiation of the bladder displayed kidney intake rates that are improved from those of the cases of not having shielded the bladder. Although there are difficulties in securing blood vessels, it is deemed that the method of direct injection would be more helpful in acquisition of better images since it displays improved kidney intake rate in comparison to other methods.

  • PDF

A Distribution of Waist-hip Ratio Associated with the Blood Pressure in Middle-aged Men (중년 남성에서 혈압과 관련한 허리-엉덩이 둘레비 산출)

  • Kim, Dae-Sung;Kim, Jai-Yong;Ahn, Yoon-Ok;Bae, Jong-Myon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.3
    • /
    • pp.395-399
    • /
    • 1999
  • Backgroud: Excess abdominal fat, expressed as an increased ratio of waist to hip circumferences (WHR), is independently associated with higher levels of blood pressure. Although a WHR greater than 1.0 in men has been shown to predict complications from obesity, the WHR has not been evaluated in all ethnic groups. Methods: In order to ascertain the association between WHR and classification of blood pressure and to investigate the critical value of WHR as a predictive factor of hypertension in Korean middle-aged men, we compared the mean of WHRs according to the classification of blood pressure in Seoul Cohort participants. Results: Through a surrey of direct measurement of waist and hip girth, 452 subjects were recruited from the cohort. The mean of WHR was 0.88 and its standard deviation was 0.04. The mean of WHRs was higher in the systolic blood pressure group (above 140 mmHg), diastolic blood pressure group (above 90 mmHg), and hypertension group than in the systolic blood pressure group (below 140 mmHg), diastolic blood pressure group (below 90 mmHg), and normotensive group, respectively. And WHR of above 0.89 was associated with hypertension (z-value =6.66). Conclusion: It is necessary for Korean males with WHR greater than 0.89 to recommend the primary prevention and early defection of hypertension.

  • PDF

Hybrid Filter Based on Neural Networks for Removing Quantum Noise in Low-Dose Medical X-ray CT Images

  • Park, Keunho;Lee, Hee-Shin;Lee, Joonwhoan
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.15 no.2
    • /
    • pp.102-110
    • /
    • 2015
  • The main source of noise in computed tomography (CT) images is a quantum noise, which results from statistical fluctuations of X-ray quanta reaching the detector. This paper proposes a neural network (NN) based hybrid filter for removing quantum noise. The proposed filter consists of bilateral filters (BFs), a single or multiple neural edge enhancer(s) (NEE), and a neural filter (NF) to combine them. The BFs take into account the difference in value from the neighbors, to preserve edges while smoothing. The NEE is used to clearly enhance the desired edges from noisy images. The NF acts like a fusion operator, and attempts to construct an enhanced output image. Several measurements are used to evaluate the image quality, like the root mean square error (RMSE), the improvement in signal to noise ratio (ISNR), the standard deviation ratio (MSR), and the contrast to noise ratio (CNR). Also, the modulation transfer function (MTF) is used as a means of determining how well the edge structure is preserved. In terms of all those measurements and means, the proposed filter shows better performance than the guided filter, and the nonlocal means (NLM) filter. In addition, there is no severe restriction to select the number of inputs for the fusion operator differently from the neuro-fuzzy system. Therefore, without concerning too much about the filter selection for fusion, one could apply the proposed hybrid filter to various images with different modalities, once the corresponding noise characteristics are explored.

Analysis of Genre-specific Competition Patterns in Korean Online Game Market using Market Dominance Assessment of Major Game Contents (주요 게임 콘텐츠의 시장 지배력 평가를 통한 한국 온라인 게임 시장의 장르별 경쟁 유형 분석)

  • Ryu, Sung-Il;Park, Sun-Ju
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.145-151
    • /
    • 2011
  • This study assumed the competitive structure based on genre classification for Korean online game contents market, and carried out the analysis on the degree and characteristics of the competition that appear differently in each sub market classified according to the genre. First, to analyze the market power of the rank 1 and 2 game contents in each genre, using the play time share ratio and standard deviation statistics values in the genre, ANOVA analysis and Cluster analysis were carried out for each genre. According to ANOVA analysis result, in the rank 1 game share ratio in each genre, there was a relationship of 'FPS/Racing > RST/Sports > Poker > Go-stop > RPG > Arcade > Board', and in the play time total share ratio of rank 1 and 2 games, the relationship of 'RTS > FPS/Racing > Sports > RPG > Go-stop > Poker > Arcade > Board' was verified. And in Cluster analysis, the groups of the genres with the degree of market power tendency and the variability at similar level were classified and stated.

Dietary Molar Ratios of Phytate : Zn and Phytate $\times$ Ca : Zn for Zn Nutrition Assessment in Koreans

  • Kwun, In-Sook;Kwon, Chong-Suk
    • Nutritional Sciences
    • /
    • v.2 no.2
    • /
    • pp.82-87
    • /
    • 1999
  • Zinc nutriture in South Koreans was evaluated by estimating Zn, Ca, and phytate intake, and the molar ratios of phytate : Zn and the millimolar ratios of phytate $\times$ Ca Zn. food consumption data from the 95 National Nutrition Survey was used. For the present study, data from the nationwide, large city and urban area level were used. No standard deviation measures were provided in the 95 National Nutrition Survey : only mean values were reported. Nationwide daily intake of Zn and Ca were 10.1 mg/day and 426.5 mg/day, respectively. The estimated daily phytate intake was 1676.6 mg/day nationwide. The molar ratio of phvtate : Zn, the millimolar ratio of phytate $\times$ Ca : Zn and the phytate $\times$ Ca Zn mmol per 4.2 MJ (1000 kcal) were 15.9, 168.9 and 91.8 in nationwide, respectively. The major food groups for zinc intake were meat, poultry products (43%), and cereals and grain products (18%). Sixty two percent of Zinc was from animal food sources. Cereal and grain products supplied most of the phytate intake (46%), followed by seasonings, fruits, and legume products. The major food source of phytate was rice (39%) . The results of the present study suggest that Zn status of Koreans maybe influenced by high dietary intake of phytate and high molar ratios of phytate : Zn and phytate $\times$ Ca : Zn. These results raise concerns about Zn status of Koreans, who consume a diet higher in phytate than Western diets. further research is necessary to confirm whether such poorly available dietary Zn has any impact on the health of Koreans.

  • PDF

Influence of Blankholding Force and Blank Diameter on the Drawability and Quality of Very Small Cylindrical Cups (극소형 원통컵의 드로잉성과 품질에 미치는 블랭크 홀딩력과 블랭크 직경의 영향)

  • Lee, K.S.;Kim, J.B.;Jung, W.J.;Kim, J.H.
    • Transactions of Materials Processing
    • /
    • v.23 no.8
    • /
    • pp.489-494
    • /
    • 2014
  • Micro forming is an appropriate process to manufacture very small metal parts which can be employed in the field of electronic devices or electrically controlled mechanical systems. The purpose of the current study was to investigate the influences of both blankholding force and blank diameter for the deep drawing of very small cups. It is essential to control the blankholding force because improper force can result in defects such as wrinkles in the flange or cracks in the corner of the drawn cups. In the current study blankholding force was controlled by springs connected to the blankholder of a press die. Exchangeable bushing dies with various die-corner radii were also used. To obtain the limit drawing ratio for each working condition several sizes of circular specimens were prepared using blanking tools. Beryllium copper(C1720) alloy sheet of $50{\mu}m$ thickness was chosen for the experiments. The maximum limit drawing ratio of 2.1 was achieved experimentally for the conditions of the blankholder force(BHF)=5.3kgf and Rd=0.3mm. Both thickness and hardness along the central section of drawn cups were measured and compared for different drawing conditions. It was found that the deviation of measured data in the thickness and hardness distribution increases with increasing blankholder force and blank diameter.

The Analysis of Kinematic Difference in Glide and Delivery Phase for the High School Male Shot Putter's Records classified by Year (남자 고등부 포환던지기 선수들의 연도 별 기록에 따른 글라이드와 딜리버리 국면의 운동학적 차이)

  • Park, Jae-Myoung;Chang, Jae-Kwan;Kim, Tae-Sam
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.4
    • /
    • pp.295-306
    • /
    • 2013
  • The purpose of this study was to provide high school male shot putters training methods of gliding and delivery motion through comparative analysis of kinematic characteristics. To accomplish this purpose, three dimensional motion analysis was performed for the subjects(PKC, KKH, YDL) who participated in high school male shot putter competition on 92nd (2011), 93rd (2013) National Sports Festival. The subjects were filmed by four Sony HXR-MC2000 video cameras with 60 fields/s. The three-dimensional kinematic data of the glide, conversion and delivery phase were obtained by Kwon3d 3.1 version. The data of the shoulder rotational angles and projection angles were calculated with Matlab R2009a. The following conclusions had been made. With the analysis of the gliding and stance length ratio, the gliding length was shorter at the TG than the SG with short-long technique but the gliding and stance length ratio was 46.8:53.2% respectively. The deviation of the shots trajectory from APSS(Athlete-plus-shot-system) revealed that the PKC showed similar to "n-a-b-c-I" of skilled S-shape type, KKH and YDL showed "n-a-d-f-I'" of unskilled type. Furthermore, they showed smaller radial distance from the central axis of the APSS and the shots were away from the linear trajectory. From this characteristics, The PKC who performed more TG than SG had shorter glide with S-shape of APSS(skilled type) showed the better record than others with technical skill. But KKH and YDL had bigger glide ratio with "n-a-d-f-I'" of unskilled type and improved their records with technical factor. The projection factor had an effect on the record directly. Because PKC maintained more lower glide and transition posture with momentum transfer through COG's rapid horizontal velocity respectively the subject possessed the characteristics of high horizontal and vertical velocity with large turning radius from shot putter to APSS.

Effects of Thoracic Flexibility Exercise Program on Pain, Heart Rate Variability, and Depression in Patients with Chronic Low Back Pain (흉추 가동성 운동프로그램이 만성 요통 환자의 통증과 심박 변이도 및 우울증에 미치는 영향)

  • Park, Donghwan;Lee, Eunhyuk;Lee, Kangseong
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.4
    • /
    • pp.161-170
    • /
    • 2019
  • Purpose : This study aimed to investigate the effects of a thoracic flexibility exercise program on pain, heart rate variability (HRV), and depression in patients with chronic low back pain. Methods : Fifty patients with chronic low back pain participated in this study. Each participant performed a pre-test and post-test. The outcome measures evaluated were a visual analog scale, HRV test results (automatic activity, standard deviation normal to normal [SDNN], low frequency [LF], high frequency [HF], and LF/HF ratio), and the Beck Depression Inventory. Patients underwent conventional physiotherapy for 35 minutes per session. In addition, a thoracic flexibility exercise program (trunk rotation exercise, McKenzie exercise, and supine thoracic extension exercise) were performed 3 times per week for 4 weeks. Results : After the training period, the visual analog scale results showed a significant decrease in the post-test compared to the pre-test. Automatic activity, SDNN, LF, HF, and LF/HF ratio significantly increased in the post-test compared to the pre-test. The Beck depression inventory results significantly decreased in the post-test compared to the pre-test. Conclusion : This study demonstrated that a thoracic flexibility exercise program improves a visual analog scale, HRV (automatic activity, SDNN, LF, HF, and LF/HF ratio), and the Beck Depression Inventory in patients with chronic low back pain.