• Title/Summary/Keyword: deviation correction

Search Result 274, Processing Time 0.022 seconds

Correction of the deviated tip and columella in crooked nose

  • Suh, Man-Koon
    • Archives of Plastic Surgery
    • /
    • v.47 no.6
    • /
    • pp.495-504
    • /
    • 2020
  • The primary procedural components of deviated nose correction are as follows: osteotomy to correct bony deviation, septal deviation correction, manipulation of the dorsal septum to correct upper lateral cartilage deviation, and correction of functional problems (manipulation for correction of internal valve collapse and hypertrophy of the inferior turbinate). The correction of tip and nostril asymmetry cannot be overemphasized, because if tip and nostril asymmetry is not corrected, patients are unlikely to provide favorable evaluations from an aesthetic standpoint. Tip asymmetry, deviated columella, and resulting nostril asymmetry are primarily caused by lower lateral cartilage problems, which include deviation of the medial crura, discrepancy in the height of the medial crura, and asymmetry or deformity of the lateral crura. However, caudal and dorsal septal deviation, which is a more important etiology, should also be corrected. A columellar strut graft, correction of any discrepancy in the height of the medial crura, or lateral crural correction is needed to correct lower lateral cartilage deformation depending on the type. In order to correct caudal septal deviation, caudal septal shortening, repositioning, or the cut-and-suture technique are used. Surgery to correct dorsal septal deviation is performed by combining a scoring and splinting graft, a spreader graft, and/or the clocking suture technique. Moreover, when correcting a deviated nose, correction of asymmetry of the alar rim and alar base should not be overlooked to achieve tip and nostril symmetry.

Development of Ship's Digital Compass Based on High Accuracy Flux-gate Sensor (고정밀 프럭스-게이트 센서를 이용한 선박용 디지털 컴퍼스 개발)

  • Yim Jeong-Bin;Saha Rampadha
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.77-85
    • /
    • 2006
  • The last target of this study is to develop ship's Digital Compass that can be substitute with conventional ship's Magnetic Compass. At first, new Digital Compass system was developed with three-axis high accuracy Flux-gate sensors and small sized step motor. Then after, new deviation correction theory without ship's swinging procedures was proposed to provide automatic deviation analysis, correction and renewal. Throughout the performance evaluation tests on the training ship 'SAE-NU-RI', the effectiveness of developed Digital Compass and proposed deviation correction theory are verified.

  • PDF

A Case of Seismic Crosshole Tomography Applying Borehole Deviation Correction (시추공 편차 보정을 적용한 탄성파시추공토모그래피 사례)

  • Kang, Jong-Seok;Cha, Young-Ho;Jo, Churl-Hyun;Choi, Jong-Ho;Shim, Weon-Hum;Park, Yong-Sung
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.221-224
    • /
    • 2006
  • seismic crosshole tomography works applying borehole deviation correction were performed at a test site to detect a small cavity. Two correction methods were applied. The one is the constant distance correction which adds constant distance to surface borehole distance and the other is the constant angle correction which considers an angle between surface borehole location and bottom borehole location. After applying the corrections, the distortions of the image diminished while its resolution improved. Though the constant angle correction is the most appropriate correction method, the constant distance correction can delineate the small cavity sufficiently.

  • PDF

NASA Model Deviation Correction for Accuracy Improvement of Land Surface Temperature Extraction in Broad Region (NASA 모델의 편차보정에 의한 광역지역의 지표온도산출 정확도 향상)

  • Um Dae-Yong;Park Joon-Kyu;Kim Min-Kyu;Kang Joon-Mook
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.281-286
    • /
    • 2006
  • In this study, acquired time series Landsat TM/ETM+ image to extract land surface temperature for wide-area region and executed geometric correction and radiometric correction. And extracted land surface temperature using NASA Model, and I achieved the first correction by perform land coverage category for study region and applies characteristic emission rate. Land surface temperature that acquire by the first correction analyzed correlation with Meteorological Administration's temperature data by regression analysis, and established correction formula. And I wished to improve accuracy of land surface temperature extraction using satellite image by second correcting deviations between two datas using establishing correction formula. As a result, land surface temperature that acquire by 1,2th correction could correct in mean deviation of about ${\pm}3.0^{\circ}C$ with Meteorological Administration data. Also, could acquire land surface temperature about study region by relative high accuracy by applying to other Landsat image for re-verification of study result.

  • PDF

Effect of Bong Chuna Manual Treatment Combined with Oriental Medical Treatment on Posterior Inferior Ilium Deviation ; 3 Cases Report (봉추나요법과 한방치료를 병행한 후하방장골 변위 교정 3예)

  • Oh, Won-Kyo;Shin, Byung-Cheul
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.1
    • /
    • pp.173-185
    • /
    • 2008
  • Objectives : The purpose of this study was to observe the effect of Bong (a type of stick which is called bong) Chuna manual therapy (CMT) on the correction of posterior inferior (PI) ilium deviation, and evaluate changes of pain intensity and Oswestry Disability Index (ODI) for the treatment of low back pain. Methods : We measured leg length inequality (LLI), as an indicator of correction of PI ilium, before and after the Bong CMT twice immediately, and also checked the change of LLI in the course of 10 times of treatment. Ten times of Bong CMT with oriental medical treatment, such as acupuncture and bee venom pharmacopuncture, were performed not only to correct the PI ilium deviation but also to alleviate pain. Visual Analog Scale (VAS) and Oswetry Low-back Pain Disability Index (ODI) score were scored to evaluate the pain and function of low back. Results : In this study, LLI was decreased in general while we performed correction of PI ilium deviation immediately, also effectively decreased comparing between before and after 10 times of Bong CMT, Bong CMT with oriental medical treatment improved pain and function of low back. Conclusions : These results suggest that Bong CMT may be an effective method for the correction of PI ilium deviation. However more rigorous study should be followed because of small cases report.

Method of Decreasing the Deviation of Corrected Engine Torque using Knock Correction Rate in Gasoline Engine Performance Test on Dynamometer (가솔린엔진 대상 성능시험시의 노킹보정률을 사용한 엔진 수정토크의 편차개선)

  • Cho, Yoon-Ho;Kim, Woo-Tai;Bae, Choong-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.4
    • /
    • pp.1-7
    • /
    • 2008
  • Recent trends of development in small size gasoline engines are both to have higher compression ratio for the purpose of improved fuel consumption and to advance spark timing up to DBL in a low to mid engine speed region for a good acceleration performance of vehicles. However, there occurs the deviation of corrected engine torque results during engine performance test on dynamometer because test conditions influence the onset of knock. Therefore, this research shows the test deviation of corrected engine torque decreases when knock correction rate is used.

An Arc Sensor and Its Interface System for Welding Robots (용접로봇용 아크센서 및 인터페이스 시스템)

  • 오승준;김재웅
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.1
    • /
    • pp.76-82
    • /
    • 2000
  • An arc sensor system to compensate positional errors was developed on the foundation of sensor interface system to make use of the on-line shift function of industrial welding robot. Investigating the on-line shift function, we examine the quantitative relationship between the deviation from programmed path and the correction data transferred from personal computer to robot controller. The number of input parameters for weld seam tracking can be reduced by making the relationship between the deviation and the correction data during half weaving be the function of only cross time. With the results of weld seam tracking for the butt joint with V-groove and fillet joint of sheet metal, good performance was implemented. By developing the sensor interface system to compensate the positional errors, industrial welding robot can be expected to contribute to the promotion of welding automation.

  • PDF

Ranging the Distance Between Wireless Sensor Nodes Using the Deviation Correction Method of Received Signal Strength (수신신호세기의 편차 보정법을 이용한 무선센서노드 간의 거리 추정)

  • Lee, Jin-Young;Kim, Jung-Gyu
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.7 no.2
    • /
    • pp.71-78
    • /
    • 2012
  • Based on the Zigbee-based wireless sensor network, I suggest the way to reduce errors between the short distance, improving the accuracy of the presumed distance by revising the deviation of RSSI(Received Signal Strength Indication) values is to estimate the distance using only the RF signal power without the additional hardware. In general, the graph measured by RSSI values shows the proximity values which are ideally reduced in proportion to the distance under the free outdoor space in which LOS(Line-Of-Sight) is guaranteed. However, if the result of the received RSSI values are each substituted to the formula, it can produce a larger margin of error and less accurate measurement since it is based upon the premise that this free space is not affected by reflected waves or obstacles caused by the ground and electronic jamming engendered by the environment. Therefore, the purpose of this study is to reduce the margin of errors between the distances and to measure the proximity values with the ideal type of graph by suggesting the way to revise the received RSSI values in the light of these reflected waves or obstacles and the electronic jamming. In conclusion, this study proves that errors are reduced by comparing the proposed deviation correction method to the revised RSSI value.

Development of Ship's Digital Compass Using Flux-gate Sensors with High Accuracy (고정밀 프럭스-게이트 센서를 이용한 선박용 디지털 컴퍼스 개발)

  • Yim Jeong- Bin
    • Journal of Navigation and Port Research
    • /
    • v.30 no.5 s.111
    • /
    • pp.321-329
    • /
    • 2006
  • The ultimate target cf this study is to develop ship's Digital Compass that can substitute for conventional ship's Magnetic Compass. At first, a new Digital Compass system consisting of three-axis Flux-gate sensors and small sized step motor was developed Then, new deviation adjustment theory incorporating with Kalman filter method was proposed through which automatic deviation analysis and correction are obtainable without ship's swinging procedures. The effectiveness of developed Digital Compass and proposed deviation adjustment theory are verified throughout the performance evaluation tests on the training ship 'SAE-NU-RI'.

Development of the Electronic compass for Automatic Correction do Deviation (自動自差修正이 가능한 電子컴퍼스의 개발에 관한 연구)

  • Ahn, Young-Wha;Shin, Hyeong-Il;Shirai, Yasuyuki
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.4
    • /
    • pp.319-327
    • /
    • 2004
  • The Electronic compass made as a pilot model in this research is comprised of a three axis magnetic sensor, an accustar clinometer, and a fiber optic gyro sensor. The results confirming the output character, performance, and the accuracy of the deviation corrects of each sensor are as follows: 1) As for the output character of the three axis magnetic sensor, the magnetic field showed a cosine curve on the X axis, a - sine curve on the Y axis, and constant figures on the Z sensor. The horizontal component H and the vertical component V of the terrestrial magnetism calculated from the output voltage were 33.2${\mu}$T and 23.95${\mu}$T respectively. 2) When the fiber optic gyro sensor is fixed on the electromotive rotation transformation and has made a clockwise rotation with the speed of 10/sec, 20/sec, and 30/sec, the relationship between the output and the rotation angle of the fiber optic gyro sensor showed proportionally constant values. 3) When the magnetic field was induced with a magnet, the deviation before the correction was significant at a high of 25. However, the deviation after the correction using Poisson correction was in the 2 range, significantly lower than before the correction. It was confirmed that automatic deviation corrects are possible with the electronic compass made as a pilot model in this research.