• 제목/요약/키워드: deviation angle

검색결과 508건 처리시간 0.026초

선체 주변에서의 전자자기 컴퍼스의 선수방위 자차변화 (The Varies of Deviation on the Ship's Head up bearing of the electromagnetic Compass around Ship)

  • 조현정;신형일
    • 수산해양기술연구
    • /
    • 제35권1호
    • /
    • pp.11-18
    • /
    • 1999
  • In order to secure accuracy and effectiveness of the electromagnetic compass as information sensor for ship's head up bearing with gyro compass, magnetic compass and electromagnetic compass on the sea and on the dock in land.The results obtained were as follows;1. Between the Northeast and the southsouthwest the deviation on ship's head up bearing on electromagnetic compass got easterly deviation with max. $53^{\cire}$on the East and between the Southwest and the Northnortheast westerly deviation with max. $34^{\cire}$ on the Northwest, of which values were not able to be corrected due to the angle excess of deviation adjustment.2. The varies of deviation seemed to have a tendency to increase easterly deviation on the Northeast and the East, easterly deviation after westerly deviation between the South and the Northwest, small one on the North and the Southeast.3. The varies of deviation of ship were larger than the one of around the dock, were extreme on the bow of forecastle deck and were stable on the ship's center line of compass deck at the dock in land.

  • PDF

혼합 치열기 아동의 연조직 측모에 관한 두부방사선 계측학적 연구

  • 서정훈
    • 대한치과의사협회지
    • /
    • 제24권2호통권201호
    • /
    • pp.143-152
    • /
    • 1986
  • The soft tissue profiles of 56 normal children were studied on their cephalograms and follow ing conclusions were made. 1. Upper facial height, Lower facial height, lower lip length were longer in female. 2. Facial convexity including the nose was convex in female. 3. Nasolabial angle, columella facial angle were larger in female. 4. Standard deviation wiggle grams were made.

  • PDF

문서입력 작업 시 컴퓨터 키보드 유형이 손목관절의 운동학적 특성에 미치는 영향 (The Effect of Standard Keyboard and Fixed-Split Keyboard on Wrist Posture During Word Processing)

  • 권혁철;정동훈;공진용
    • 한국전문물리치료학회지
    • /
    • 제11권1호
    • /
    • pp.35-43
    • /
    • 2004
  • There were two purposes of this study. The first was to research the effects of standard and fixed-split keyboards on wrist posture and movements during word processing. The second was to select optimal computer input devices in order to prevent cummulative trauma disorder in the wrist region. The group of subjects consisted of thirteen healthy men and women who all agreed to participate in this study. Kinematic data was measured from both wrist flexion and extension, and wrist radial and ulnar deviation during a 20 minute period of word processing work. The measuring tool was an electrical goniometer, and was produced by Biometrics Cooperation. The results were as follows: 1. The wrist flexion and extension at resting starting position were not significantly different (p>.05), however the angle of radial and ulnar deviation were significantly different in standard and split keyboard use during word processing (p<.05). 2. In the initial 10 minutes, the dynamic angle of wrist flexion and extension were not significantly different (p>.05), however the dynamic angle of radial and ulnar deviation was significantly different in standard and split keyboard use during word processing (p<.05). These results suggest that the split keyboard is more optimal than the standard keyboard, because it prevented excessive ulnar deviation during word processing.

  • PDF

Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions

  • Ozcan Akkal;Ismail Hakki Korkmaz;Funda Bayindir
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권4호
    • /
    • pp.179-188
    • /
    • 2023
  • PURPOSE. This in vitro study aimed to evaluate the performance of digital intraoral scanners in a completely edentulous patient with angled and parallel implants. MATERIALS AND METHODS. A total of 6 implants were placed at angulations of 0°, 5°, 0°, 0°, 15°, and 0° in regions #36, #34, #32, #42, #44, and #46, respectively, in a completely edentulous mandibular polyurethane model. Then, the study model created by connecting a scan body on the implants was scanned using a model scanner, and a 3D reference model was obtained. Three different intraoral scanners were used for digital impressions (PS group, TR group, and CS group, n = 10 in each group). The distances and angles between the scan bodies in these measurement groups were measured. RESULTS. While the Primescan (PS) impression group had the highest accuracy with 38 ㎛, the values of 104 ㎛ and 171 ㎛ were obtained with Trios 4 IOSs (TR) and Carestream 3600 (CS), respectively (P = .001). The CS scanner constituted the impression group with the highest deviation in terms of accuracy. In terms of dimensional differences in the angle parameter, a statistically significant difference was revealed among the mean deviation angle values according to the scanners (P < .001). While the lowest angular deviation was obtained with the PS impression group with 0.185°, the values of 0.499° and 1.250° were obtained with TR and CS, respectively. No statistically significant difference was detected among the impression groups in terms of precision values (P > .05). CONCLUSION. A statistically significant difference was found among the three digital impression groups upon comparing the impression accuracy. Implant angulation affected the impression accuracy of the digital impression groups. The most accurate impressions in terms of both distance and angle deviation were obtained with the PS impression group.

상수리나무 심재(心材)와 변재판재(邊材板材)의 두께와 연륜각도(年輪角度)가 열판건조(熱板乾燥)에 미치는 영향(影響) (Effect of Board Thickness and Ring Angle on Press - drying for Heartwood and Sapwood of Quercus acutissima C.)

  • 이남호;정희석
    • Journal of the Korean Wood Science and Technology
    • /
    • 제15권2호
    • /
    • pp.67-78
    • /
    • 1987
  • This study was designed to investigate the effect of board thickness and ring angle on the characteristics including internal check. ring failure, surface check, end check, collapse, thickness shrinkage and width shrinkage of press-drying. The exprimental materials of 6mm-. 9mm- and 12mm-thick board were taken from heartwood and sapwood of oak (Quercus acutissima Carr.) respectively. And boards were numbered according to position in the log(No. 1 to No. 4 for heartwood :md No. 9 for sapwood). Press-drying was at $145^{\circ}C$ platen temperature and 3.5kg/$Cm^2$ platen pressure. The results of this study were summarized as follows. 1. Drying rates for sapwood materials were greater than those for heartwood materials. And drying rates for thinner materials were greater than those for thicker materials. 2. The thinner boards were. the severer surface checking developed in the heartwood materials, and surface checking for heartwood materials had no tendency in board position for the same thickness. Sapwood materials were completely free from surface checking. 3. End checking for heartwood materials had no tendency in board position. The greater deviation of ring angle from perfectly edge-grained was, the severer and checking developed in the sapwood materials. But end checking did not occur in 6mm-thick sapwood materials. 4. The greater deviation of ring angle from perfectly edge-grained was, the severer end checking developed for heartwood and sapwood materials. As board thickness increased, maternal checking developed more severely for heartwood and sapweed materials. 5. For heartwood materials, ring failure, reduced with increasing deviation of ring angle from perfectly edge-grained except 12mm-thick material and showed no significant difference attributable to board thickness. Sapwood materials were completely free from ring failure. 6. For heartwood and sapwood materials, collapse was slight and showed no significant differences attributable to both board thickness and board position. 7. As deviation of ring angle from perfectly edge-grained increased, shrinkage of board thickness decreased for heartwood and sapwood materials. 8. Shrinkage of board width showed no significant differences attributable to both board thickness and board position for heartwood and sapweed materials.

  • PDF

Cone-beam CT를 이용한 안면비대칭자에서 이부편위에 따른 치성보상의 양상분석 (Correlation between menton deviation and dental compensation in facial asymmetry using cone-beam CT)

  • 박수병;박정희;정연화;조봉혜;김용일
    • 대한치과교정학회지
    • /
    • 제39권5호
    • /
    • pp.300-309
    • /
    • 2009
  • 본 연구는 Cone-beam CT의 MPR이미지상에서 하악골 평면에 대한 하악 제1대구치와 견치의 편위측과 비편위측의 높이와 각도차이 그리고 FH 평면에 대한 상악 제1대구치와 견치의 편위측과 비편위측의 높이와 각도차이를 계측함으로써 안면비대칭자에서 이부편위에 따른 편위측과 비편위측의 제1대구치와 견치의 높이와 협설측 경사도를 CBCT를 이용하여 분석하고 그 관련성을 알아보는 데 있다. 연구대상은 하악골의 이부편위를 동반한 안면비대칭 환자 50명(여자 29명, 남자 21명, 평균나이 24세 4개월)으로 하였다. 대조군으로 평균나이 25세 7개월인 20명(남자 11명, 여자 9명)을 분석하였다. 결과는 이부편위에 대해 FH 평면에 대한 상악 제1대구치의 편위측과 비편위측의 길이 및 각도 차이(편위측 - 비편위측)는 대조군에 대해 통계적으로 유의한 차이가 존재하였다 (p < 0.01). 비대칭군에서 상악 제1대구치 각도는 편위측이 비편위측보다 평균 $8.62\;{\pm}\;5.95^{\circ}$ 컸다 (p < 0.01). 상악 견치의 경우에도 편위측과 비편위측의 각도차이가 평균 $4.48\;{\pm}\;5.05^{\circ}$로 통계적으로 유의한 차이가 존재하였다 (p < 0.01). 하악골 평면에 대한 하악 제1대구치의 수직 길이와 각도는 편위측과 비편위측에서 통계적으로 유의할 만한 차이가 존재하였다 (p < 0.01). 각도의 차이는 평균 $-11.92\;{\pm}\;5.79^{\circ}$로 나타났다. 이부편위에 대한 상하악 제1대구치와 견치의 수직거리 및 각도의 Pearson 상관분석 및 회귀분석 결과, FH 평면에 대한 상악 제1대구치의 편위측과 비편위측의 각도차이(${\Delta\angle}UM6$-FH plane (dev.-ndev.))는 통계적으로 유의한 양의 상관관계를 나타내었고, 하악골 평면에 대한 하악 제1대구치의 편위측과 비편위측의 각도차이(${\Delta\angle}LM6$-Mn plane (dev.-ndev.))는 통계적으로 유의한 음의 상관관계를 나타내었다. 이상의 결과에서 이부편위를 동반한 하악골 비대칭이 존재하는 경우, 이부가 편위되는 방향으로 상하악 제1대구치의 치아장축의 각도가 변화되는 것으로 나타났다.

평면 LED 램프에서의 초음파 센서의 반사특성을 고려한 위치측정 기법 (Location Measurement method Depending on Reflection Characteristics of Ultrasonic Sensors for The Flat LED Lamp)

  • 허영록;윤장희;염정덕
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.38-43
    • /
    • 2013
  • In this paper, the location measurement method for the reliable location data using ultrasonic sensors is proposed for the dimming control of the LED flat lamp. The measurement errors depending on the reflection angle of the object have to be considered to obtain the reliable location data in the ultrasonic sensors. In the experiment, the cause of the measurement errors depending on reflection angle is analyzed and velocity change of ultrasonic wave depending on reflection angle is measured. And the location measurement method depending on velocity change of ultrasonic wave is proposed. From the results, the average absolute deviation of the x-coordinates was 1.47cm when the location measurement method was considered, and it was closer to the true values than the average absolute deviation of the x-coordinates which was 5.89cm without regard to the reflection angle.

Lateral Body Shapes of Males in Their 20s for the Development of Educational Dress Forms (Part 2)

  • Yoo, Hyun;Shim, Boo-Ja
    • 패션비즈니스
    • /
    • 제9권3호
    • /
    • pp.47-63
    • /
    • 2005
  • The study with the subjects at 200 adult males in Busan in their 20s had a purpose at analyzing lateral body shapes to develop men's educational dress forms. The following are the conclusions: 1. Comparison at the Body Dimensions at Busan Male Adults in Their 20s and the 5th Survey at Korean Body Measurement In the comparison at the Busan and national body dimensions by way at Mollison's relative deviation, all compared items were under the deviation of 0.7. Therefore, the sample of Busan male grown-ups is understood io represent the body shapes of the average Korean male adults in their 20s. 2. Results of Lateral Body Shape Classification From factor analysis, seven factors were produced to explain 75.45% of all variables. Those 7 factors to compose lateral body shapes were hip prominence, back-neck sides, upper body's front-back depth, lateral upper body depth, hip-waist depth, front chest-waist depth, and hip and waist height. Cluster analysis revealed four characteristic lateral body shapes. Type 1 with the appearance rate of 11.70%, named D, had the greatest upper chest angle and tanterior neck lower angle. The front side was more developed. Type 2 with 33.51%, named I, was generally long and slender. Type 3 with 24.47%, named d, had the biggest depth differences in hip-chest as well as more prominent back hip. Type 4 with 30.32%, named q, had the biggest dorsal upper angle and the tiniest chest upper angle as the back area was a little bent.

3-D CT를 이용한 악교정술 전후의 하악과 설골의 위치에 관한 연구 (THE POSITIONAL RELATIONSHIP BETWEEN THE MANDIBLE AND THE HYOID BONE IN MANDIBULAR PROTRUSION AFTER ORTHOGNATHIC SURGERY EVALUATED WITH 3-D CT)

  • 이상한;남정훈;정창욱;권대근
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제29권3호
    • /
    • pp.173-181
    • /
    • 2003
  • Purpose : This study was intended to evaluate the positional relationship between the hyoid bone and the mandible in patients with mandibular protrusion after mandibular set-back surgery by means of 3D-CT. Materials and methods : Preoperative(3 weeks before) and postoperative (6 weeks after) 3D-CT & cephalogram were taken on 32 patients(12 male, 20 female, mean age of 23.2) treated by bilateral sagittal split osteotomy with rigid fixation. The angular measurement on 3D-CT basilar view were deviation of Me & H, long axis angle of left & right cornu majus. The lineal measurement on 3D-CT basilar view were composed of intercondylar line and coordinates(x,y) of Me & H. The angular & lineal measurement of lateral cephalogram were composed of mandibular plane angle, SNA, SNB, ANB, FH-NA & FH-NB, and coordinates(x,y) of B, Pog, Me & H, PAS, Lpw, MPH and IAS. On the frontal cephalogram, deviation of Me were evaluated. Results : The mean mandibular set-back was 8.0mm horizontally and mandibular plane angle was slightly increased. The hyoid bone was displaced postero-inferiorly, the distance between MP(mandibular plane) and H(hyoid bone) was increased and the posterior airway space values (PAS, Lpw, IAS) were decreased. The coordinates Me(x,y), H(x,y) and deviation angle Me'& H' were revealed the strong positive correlation. Conclusion : The results revealed that the horizontal, vertical and transverse relationship of the mandibular and the hyoid bone movements were significantly correlated in patients performed mandibular set-back surgery.

굴절이상과 편위각에 따른 망막대응의 임상적 고찰 (Clinical Features of Retinal Correspondence according to Refractive Errors and Deviation Angles)

  • 위대광;주석희;이군자;임현성
    • 한국안광학회지
    • /
    • 제15권4호
    • /
    • pp.367-372
    • /
    • 2010
  • 목적: 굴절이상과 편위각의 크기에 따라 정상망막대응과 이상망막대응의 분포를 확인하여 사시환자의 감각기능 평가에 있어 도움이 되고자 하였다. 방법: 56명(남: 26명, 여: 30명)을 대상으로 타각적 굴절검사와 자각적 굴절검사를 하였고, 원거리 완전 교정상태에서 Synoptophore(OCULUS Synoptophore, Germany)를 이용하여 타각적 사시각을 측정한 후에 자각적 사시각을 측정하였다. 굴절이상(정시, 원시, 근시)과 부등시(양안 1.00D 이상의 굴절이상차이를 보이는 경우), 편위각(미세사시각, 중간사시각, 큰 사시각)으로 구분하여 각 군별로 정상망막대응과 이상망막대응의 빈도 및 이상각의 크기도 알아보았다. 결과: 굴절이상별로 나눈 군에서 정상망막대응은 정시에서 12명(67%)으로 가장 많았고, 이상망막대응은 원시나 정시보다 근시에서 71%로 가장 많았다. 0 ~${\pm}10{\triangle}$의 미세사시각에서 이상망막대응이 가장 작게(46%) 조사되었다. 결론: 정상망막대응은 정시에서 가장 많았고 굴절이상이 클수록 이상망막대응이 많았으며 원시보다는 근시에서 이상망막대응이 더 많았다. 또한 편위각이 작을수록 정상망막대응이 많았지만 전체적으로는 이상망막대응이 많았다.