• Title/Summary/Keyword: development method

Search Result 32,252, Processing Time 0.052 seconds

Direction Finding and Tracking using Single-Ring Circular Array Antenna and Space Division Table (단원형배열안테나와 공간분할테이블을 이용한 방향탐지 및 추적)

  • Park, Hyeongyu;Woo, Daewoong;Kim, Jaesik;Park, Jinsung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.117-124
    • /
    • 2022
  • Single-ring circular array antennas can be applied to direction finding systems in order to use nose-section in other purposes, and the interferometry is a proper direction finding method to those systems. We usually make the interferometer baseline long enough to achieve good angular accuracy. However, an interferometer with baseline longer than a half-wavelength has the ambiguity problem. In this paper, we present a novel method for solving the ambiguity problem in interferometry systems. This technique is based on the amplitude comparison method and the space division table, and it can place a target within the angular region in which the ambiguity problem does not occur by roughly estimating direction-of-arrival. The Monte Carlo simulation results show that proposed method can effectively remove the ambiguity problem in the system.

Antiferroelectric Liquid Crystal Display with High Image Quality

  • Chang, Young-Joo;Yu, Jeong-Seon;Yoo, Jeong-Geun;Jeong, Dong-Jin;Park, Sung-Chon;Chae, Su-Yong;Yang, Hong-Geun
    • Journal of Information Display
    • /
    • v.3 no.4
    • /
    • pp.1-3
    • /
    • 2002
  • The antiferroelectric liquid crystal display (AFLCD) is a unique display that can at demonstrate a moving image perfectly the passive matrix driving scheme. We optimised driving the waveform and introduced a dual-driving method. Also, by improving this driving method and using line inversion method, we realize the AFLC display of high image quality with $160(RGB){\times}240$, 32768 colors, crosstalk free and flicker free contrast ratio is greater than 60:1, and the brightness is above 200 $cd/m^2$.

Design for ILS in Ammunition Development applying QFD Method (QFD를 활용한 탄약 ILS 효율화 방안 연구)

  • Lee, Seung-Mok;Park, Young-Won
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.5 no.2
    • /
    • pp.1-9
    • /
    • 2009
  • This paper proposes an effective method on the DFILS(Design for Integrated Logistics Support) in ammunition development applying QFD(Quality Function Deployment) method. The goal of this research is to define the Design for ILS approach at the start of the ammunition development and to yield a set of reusable requirements. Based on 000mm High-Explosive(Warship ammunition) development work, a QFD software tool, CUPID, was used to analyze and define the field force's requirements. Additionally, a set of reusable requirements are identified and defined for use during the Design for ILS development phase in the next-generation ammunition development process. These set of requirements that consider both the priority and importance of the VOC(Voice of Customer) will contribute to the early phase of the ammunition development to implement the Design for ILS specialty engineering effort.

  • PDF

2-Dimensional Spatial Averaging Driving Methods for High Speed Driving of AMLCDs

  • You, Bong-Hyun;Lee, Jun-Pyo;Kim, Dong-Gyu;Park, Jin-Ho;Kim, Yun-Jae;Berkeley, Brian H.;Kim, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1323-1326
    • /
    • 2007
  • A new driving method employing 2-dimensional spatial averaging is proposed. This method successfully eliminates the vertical line artifact caused by luminance difference from unbalanced charging voltage between polarities. This spatial averaging method can secure charging time, minimize driver heating, and achieve higher display quality.

  • PDF

Antiferroelectric Liquid Crystal Display with High Image Quality

  • Yu, Jeong-Seon;Chang, Young-Joo;Yoo, Jeong-Geun;Jeong, Dong-Jin;Park, Sung-Chon;Chae, Su-Yong;Yang, Hong-Geun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.545-547
    • /
    • 2002
  • The antiferroelectric liquid crystal display (AFLCD) is unique display that can show the perfect moving image using the passive matrix driving scheme. We optimized the driving waveform and introduced the dual driving method. Also, by improving this driving method and using line inversion method, we realized AFLC display with high image quality, which has 160(RGB)${\times}$240, 32768colors, crosstalk free and flicker free. The contrast ratio is greater than 60:1, and the brightness is above 200cd/$m^2$.

  • PDF

HILS Technique based on Inertial Sensor Modeling for High Maneuvering Missiles (고기동 유도탄 모의비행시험 기법 밀 관성센서 모델링)

  • Kim, Ki-Seung;Yu, Myeong-Jong;Ra, Won-Sang;Lee, Sang-Woo;Kim, Young-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2540-2542
    • /
    • 2005
  • This paper proposed the new HILS technique called Injection Method for Inertial Sensor Verification of high maneuvering missiles. The performance of Inertial Sensor is verified by Injection Method and traditional FMS Method. After all, Injection Method for Inertial Sensor has capability for various scenario and critical condition test.

  • PDF

Development of Evidence Based Clinical Practice Guideline to Improve Quality of Critical Care Nursing (중환자 간호실무 질 향상을 위한 근거중심 임상실무지침서의 개발)

  • Park, Myong-Hwa
    • Journal of Korean Critical Care Nursing
    • /
    • v.2 no.2
    • /
    • pp.68-78
    • /
    • 2009
  • Evidence based clinical practice guideline are designed to help healthcare practitioners evaluate and implement the increasing amount of evidence on best practice. Critical care area is one of the clinical sites where evidence based clinical practice guideline is needed most. This paper reviewed the definition of evidence based clinical practice guidelines, the development method of evidence based clinical practice guideline, and the current trends in guideline developing. Traditional method of guideline development is consensus based but it moves into evidence based development. Evidence based guideline is based on best available evidence and uses the strongest method to determine its effect on clinical outcomes. The current trends in guidelines is to develop the guideline at regional/national level and do subsequent modification to suit local circumstances. There is an urgent need of exploring the method of guideline development and adaptation which are appropriate for Korean clinical setting.

  • PDF

Kano모델 및 고객만족 계수를 이용한 신제품 개발

  • Park, No-Guk;Lee, Sang-Bok
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2009.10a
    • /
    • pp.358-369
    • /
    • 2009
  • In this paper, we propose development of new products including the proposed process of at the customer's requirements. The success of new product development depends on customer satisfaction in the marketplace. Existing product development process, including the customer's interest was weak. In this paper, we propose development of new products which include Kano's attractive quality factor method and Timko's customer satisfaction index factor method. Also we verified new medical treatment of incontinence-nency which is applied to the proposed process.

  • PDF

STUDY ON ANALYSIS OF SIGNIFICANCE OF SYMPTOM-TREATMENT METHOD COMBINATION

  • Oh, Yong Taek;Nam, Bo Ryeong;Kim, An Na
    • Journal of applied mathematics & informatics
    • /
    • v.32 no.5_6
    • /
    • pp.737-746
    • /
    • 2014
  • Treatment method refers to a principle or method for treating diseases in Traditional Korean Medicine(TKM). As doctors determine the ideal treatment for a patient's disease or symptom, they are also able to prescribe effective treatment means for the diseases or symptom such as medicinal materials, prescription, acupuncture and moxibustion. Therefore, if significant symptom-treatment method combinations are found from literature or database, proper treatment means for the patient's diseases or symptom may be presented to TKM doctors and enhanced treatment accuracy and efficiency can be expected. This study aims to analyze the relation between symptom and treatment method by interpreting hypotheses through null hypotheses to find significant symptom-treatment method combinations. This combinations suggested in this study will be compared with TKM experts analysis result to find an objective analysis method and eventually apply the method to medical big data, e.g., a huge amount of literature or treatment records.

Comparison between predicted total digestible nutrients and actual total digestible nutrients using nutrient digestibility of rice straw and timothy in ruminants

  • Ryu, Chae Hwa;Lee, Seul;Kim, Byeonghyeon;Ji, Sang Yun;Jung, Hyunjung;Lee, Hyun-Jeong;Song, Jae-Yong;Baek, Youl Chang
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.2
    • /
    • pp.333-342
    • /
    • 2021
  • This study attempted to compare total digestible nutrients (TDN) calculated as Rohweder, NRC, and Waldo and Peiqiang methods and TDN measured as digestibility of in vivo appearance. Rohweder method showed that the TDN of rice straw and timothy were 54.32% and 57.79%, respectively. In NRC method, the digestibility of neutral detergent fiber (NDF) and TDN of rice straw were 50.76% and 53.15%, respectively. When NRC method was applied in Timothy, the digestibility of NDF and TDN were 51.53% and 55.22%, respectively. Waldo and Peiqiang method calculated the results through the rumen in situ test. NDF digestibility of rice straw and timothy was 44.61% and 51.82%, which was different from the results of NRC method. In addition, TDN was predicted to be 48.85% for rice straw and 55.41% for timothy. In the in vivo apparent digestibility experiment, the digestibility of NDF and TDN in rice straw was 41.10% and 44.79%, respectively. In timothy, the digestibility of NDF and TDN were measured as 51.29% and 58.18%, respectively. As a result of a series of studies, rice straw was found in Rohweder and NRC methods showed higher TDN than other methods. In this study, there was a difference in rice straw by measurement method, but there was no difference in timothy. Therefore, when evaluating the value of feed in order to provide roughage to ruminant, calculation methods must be modified and supplemented. In addition, TDN should be considered to apply several evaluation methods instead of one method.