• Title/Summary/Keyword: deterioration ratio

Search Result 450, Processing Time 0.177 seconds

ZnO thin film Gas sensors for detection of TMA gas with Pt/Ti thin film heater (Pt/Ti 발열체가 내장된 TMA 가스 측정용 ZnO 박막 가스 센서)

  • 류지열;박성현;최혁환;권태하
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.6
    • /
    • pp.127-135
    • /
    • 1996
  • To increase the sensitivity and the selectivity of the sensors to TMA gas, the composition ratio and the growth conditions of the ZnO films are studied. Annealing of the ZnO films in the various time ranges and temperatures in the oxygen is carried out to enhance the stbility of the electrical resistance. Pt/Ti heater deposited on backside of the substrates in used to control the operating temperature of th esensor. The ZnO thin film sensors doped to 4.0 wt% $Al_{2}$O$_{3}$ 1.0wt.% TiO$_{2}$ and 0.2wt.% V$_{2}$O$_{5}$ exhibited a high sensitivity and an excellent selectivity for TMA gas. The sensors made with the thin films annealed at 700$^{\circ}$C for 60 minutes in the oxygen atmosphere had a good stability and linearity. The heater deposited in the ratio of 1 to 1 (Pt:Ti) had a good heating properties. The sensors fabricated using above conditions showed a good response to the actual gases of a mackerel at a step of deterioration after death.

  • PDF

The Performance Evaluation Analysis of PV System for Arch and Flat-Plate Type (평판형 및 아치형 태양광발전 시스템의 성능평가 분석)

  • Piao, Zheng-Guo;Choi, Youn-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.7
    • /
    • pp.1012-1018
    • /
    • 2015
  • The studies on the operating performance analysis or design about the fixed tilt angle flat-plate photovoltaic (PV) system are still lively going off. However the operating property analysis about the arch type PV system which means PV array were designed as round type is dissatisfied. In this paper, we theoretically established the factors which are cause of the deterioration in performance of arch type PV system. In addition, we use the Solar Pro simulation tools to design both flat-plate type and arch type 30kW PV systems. The simulations about arch type PV system applied two ways such as central inverter and string inverter were conducted. The performance ratio (PR) of the PV system with flat-plate type shows the highest value 74[%] when the tilt angle is 30°. In case of arch type, when applying central inverter method, PR value shows approximately 73[%] and no more difference with arch type of the PV array. This value shows 1[%] decrease compare with the flat-plate type. However when applying string inverter methods, the average PR value shows 80 % and 6% improved than the central inverter method.

The Modified Median Filter using Standard Deviation in Impulse Noise Environment (임펄스 잡음환경에서 표준편차를 이용한 변형된 메디안 필터)

  • Long, Xu;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.7
    • /
    • pp.1725-1731
    • /
    • 2013
  • Recently, as industrial society is developed as high digital information age, image processing is used in a variety of areas. However, image deterioration is still occurred by several noises in the data processing, and different kinds of researches are in progress for noise removal. Therefore, this paper limited the modified median filter by using standard deviation to removes impulse noise. The proposed algorithms divided into noise detection and noise removal, the noise free pixel is maintained, the noise pixel filtered. And it was compared with the existing methods for its objective judgment, using PSNR(peak signal to noise ratio) as standard criteria.

An Experimental Study on the Concrete Pore Structure Property (콘크리트의 공극 특성에 관한 실험적 연구)

  • Lee, Mun-Hwan;Jung, Mi-Kyung;Oh, Se-Chul;Seo, Chee-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.4
    • /
    • pp.179-189
    • /
    • 1999
  • This study attempts to propose an evaluation considering the property of concrete pore which affects the deterioration of neutralization and the rebar resistance of concrete. Understanding pore property of concrete in using extent, for practical using of concrete manufacturing condition. basic quality property and durability estimation etc, the results of the experiment are as follows. 1) The result of analysis pore property of every specimen with the method of area ratio, in limitation of $10^{-6}{\sim}10^{-5}m$, the pore distribution ratio was maximum. It was high value as W/C was increased and the unit cement content was decreased. 2) In case of using admixture. the volume of pores was some increased as variation of mixing content. In high W/C range, it was very increased compared with plain concrete. 3) Concerned with compressive strength and volume of pores in hardened concrete, it is possible compressive strength estimation using the property of concrete pores. 4) Direct measurement of concrete pore property is difficult. the valuation of the dynamic modulus of elasticity using ultrasonic wave velocity was available. 5) Quantitatively evaluation of concrete structure durability by past result of pore distribution estimation, and it can be estimative scale of property study on the concrete materials.

  • PDF

An empirical study of the impact which the change of age ratio of disaster response organization has on organization effectiveness and quality assurance - Focused on field activities firefighters in Seoul metropolitan city - (재난대응조직 연령구성비 변화가 조직효과성 및 서비스질 보장활동에 미치는 영향에 관한 실증분석 - 서울지역 현장활동 소방공무원을 중심으로 -)

  • Park, Chan-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.133-145
    • /
    • 2014
  • Aging of the fire organizations, typical disaster response agencies also will be in serious problems with aging society. It is expected that the ratio of more than fifties will reach 31~40% after 10~15 years in Seoul fire organization. This Aging of firefighters can bring about a serious problem in disaster and safety management, since firefighters require robust fitness and healthy bodies in disaster situations. In this study, after the analysis of aging status and trend of firefighters in Seoul, I have an empirical analysis about the impact this aging has on organization effectiveness and QA. As a result, the increase of the elderly reduced organization effectiveness and QA. In addition, in the group consisting of less than 50, it is expected to increase the organization's effectiveness and QA activities through field activity to improve the professional skills with age, but could not be confirmed. In the group consisting of more than fifties, it was found that aging had a significant negative impact on organizational effectiveness and QA activities as factors, including physical deterioration by aging.

Storage Life Investigation of Diverse Grape Cultivars (포도품종에 따른 저장성 연구)

  • 남상영;강한철;김태수
    • Food Science and Preservation
    • /
    • v.7 no.1
    • /
    • pp.29-32
    • /
    • 2000
  • Storage life of grape cultivars including Kyoho(Inzuka), which were imported from Japan and are cultivated after adoption as farming application, were examined. The stu요 was accomplished with grapes packed by PE film under storage temperature $0^{\circ}C$ and humidity 90%RH loss of weight, Weight loss and occurrence of abnormal fruit increased in proportion to storage days. Abnormal fruits of Kyoho(izuka), North Black , and Seto giants increased rapidly after 60 days of storage, resulting in slight deterioration of commercial value. Similarly, this phenomenon of Campbell early , Takasumi , and Aki Queen occurred after 70 days of storage. External appearance decreased rapidly after 60 days of storage, resulting in 7.0 index of Takatsuma and Aki Queen , 3.0-3.6 of North Black and Seto Giants, and 5.0 of Campbell Early, kyoho (izuka0, and takasumi after 80 days of storage. Soluble solide content and titratable acidity showed a trend to be decreased with lapse of storage. Sugar/acid ratio shwoed much fluctuation between different grapes. Possible storage days, in view of more 70% merchandise berry ratio, were 90 days of Takatsuma and Aki Queen , 70 days of Campbell Early, 60 days of Takasumi , kyoho(Iizuka), and Seto giants, below 60 days of North Black.

  • PDF

Effect of Premixed Fuels Charge on Exhaust Emission Characteristics of HCCI Diesel Engine (HCCI 디젤엔진의 배기특성에 미치는 예혼합 연료의 영향)

  • Kim Myung Yoon;Yoon Young Hoon;Hwang Suk Jun;Kim Dae Sik;Lee Chang Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.4
    • /
    • pp.182-189
    • /
    • 2005
  • In order to investigate the effect of premixed gasoline, diesel fuel, and n-heptane charges on the combustion and exhaust emission characteristics in a direct injection (DI) diesel engine, the experimental studies are performed. The premixed fuels are injected into the premixing chamber that installed upstream of the intake port in order to minimize the inhomogeneity effect of premixed charge. The injection nozzle for directly injected fuel is equipped in the center of the combustion chamber. The air temperature control system is equipped in the intake manifold to examine the effect of air temperature. The experimental results of this study show premixing fuel is effective method to reduce the NOx and soot emissions of diesel engine. NOx emissions are linearly decreased with increasing premixed ratio for the three kinds of premixed fuels. The heating of intake air $(80^{\circ}C)$ reduced the deterioration of BSFC in high premixed ratio, because it promotes evaporation of premixed diesel droplet in the premixing chamber.

DEVELOPMENT OF A RECONFIGURABLE CONTROL FOR AN SP-100 SPACE REACTOR

  • Na Man-Gyun;Upadhyaya Belle R.
    • Nuclear Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.63-74
    • /
    • 2007
  • In this paper, a reconfigurable controller consisting of a normal controller and a standby controller is designed to control the thermoelectric (TE) power in the SP-100 space reactor. The normal controller uses a model predictive control (MPC) method where the future TE power is predicted by using support vector regression. A genetic algorithm that can effectively accomplish multiple objectives is used to optimize the normal controller. The performance of the normal controller depends on the capability of predicting the future TE power. Therefore, if the prediction performance is degraded, the proportional-integral (PI) controller of the standby controller begins to work instead of the normal controller. Performance deterioration is detected by a sequential probability ratio test (SPRT). A lumped parameter simulation model of the SP-100 nuclear space reactor is used to verify the proposed reconfigurable controller. The results of numerical simulations to assess the performance of the proposed controller show that the TE generator power level controlled by the proposed reconfigurable controller could track the target power level effectively, satisfying all control constraints. Furthermore, the normal controller is automatically switched to the standby controller when the performance of the normal controller degrades.

The Association between Health-related Quality of Life and Depression on Activity Restriction in Osteoarthritis: A Cross-sectional Study

  • Lee, Do-Youn;Kim, Seong-Gil
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.6
    • /
    • pp.329-334
    • /
    • 2020
  • Purpose: The purpose of this study is to provide basic evidence on the need to approach osteoarthritis patients through a psychological factors-considering rehabilitation program by understanding how activity restrictions in osteoarthritis affect health-related quality of life and depression. Methods: This study assessed 3,761 osteoarthritis patients from the Korea National Health and Nutrition Examination Survey. The subjects were divided into two categories: with and without activity restriction. Results: The prevalence of osteoarthritis in women was higher than that of men (men: 19.7%; women: 80.3%), and high BMI increased the prevalence of osteoarthritis. The EQ-5D index of subjects with activity restriction was 0.84±0.18 (points), while in those without activity restriction was 0.93±0.12, and the diagnosis of depression was 15.8%, 8.2%. There was a statistically significant difference in the odds ratio for each item in the EQ-5D. Moreover, the odds ratio for depression with activity restriction was 2.098 compared with no activity restriction. Conclusion: Activity restriction of osteoarthritis patients significantly decreases the health-related quality of life and increase the probability of depression. Therefore, early diagnosis of depression symptoms to prevent deterioration of symptoms in patients with osteoarthritis and to increase compliance with rehabilitation treatment, and to provide arbitration, including treatment that can alleviate depression.

Evaluation of Ventilation Rate and External Air Mixing Ratio in Semi-closed Loop Ventilation System of Pig House Considering Pressure Loss (압력손실을 고려한 양돈시설의 반폐회로 환기시스템의 환기량 및 혼합비율 평가)

  • Park You-me;Kim Rack-woo;Kim Jun-gyu
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.1
    • /
    • pp.61-72
    • /
    • 2023
  • The increase in the rearing intensity of pigs has caused deterioration in the pig house's internal environment such as temperature, humidity, ammonia gas, and so on. Traditionally, the widely used method to control the internal environment was through the manipulation of the ventilation system. However, the conventional ventilation system had a limitation to control the internal environment, prevent livestock disease, save energy, and reduce odor emission. To overcome this problem, the air-recirculated ventilation system was suggested. This system has a semi-closed loop ventilation type. For designing this system, it was essential to evaluate the ventilation rates considering the pressure loss of ducts. Therefore, in this study, pressure loss calculation and experiment were conducted for the quantitative ventilation design of a semi-closed loop system. The results of the experiment showed that the inlet through which external air flows should always be opened. In addition, it was also found that for the optimum design of the semi-closed loop ventilation system, it was appropriate to install a damper or a backflow prevention device rather than a ventilation fan.