• Title/Summary/Keyword: deterioration level

Search Result 521, Processing Time 0.026 seconds

Urinary Change of Kallikrein in Adenine-Induced Renal Failure Rat (Adenine 유발 신부전 흰쥐에서의 뇨중 Kallikrein의 변화)

  • Lee, Tae-Woong;Seo, Suk-Soo;Lee, Kyung-Hee;Young, Han-Suk;Chung, Joon-Ki;Choi, Jae-Sue
    • YAKHAK HOEJI
    • /
    • v.35 no.6
    • /
    • pp.504-508
    • /
    • 1991
  • In order to investigate whether the function of distal nephron is disturbed in adenine-induced renal failure rats, we measured the urinary kallikrein level in adenine-ingesting rats fed on 0.75% adenine diet for 1 to 10 days. Administration of 0.75% adenine to rats significantly increased blood urea nitrogen level and urine volume, while the level of kallikrein along with the urinary excretions of urea and inorganic phosphate were significantly decreased. From these results, it is suggested that adenine-induced renal failure is caused by early deterioration of distal nephron as well as proximal nephron.

  • PDF

Harmonics Analysis of Leakage Current due to Artificial Contamination of Distribution Arresters (배전용 피뢰기의 인공오손에 의한 누설전류의 고조파 분석)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1306-1313
    • /
    • 2012
  • This paper reports the contamination performance of two distribution arresters (new and used ones) tested under three different contaminant conditions - clean fog, ESDD (equivalent salt deposit density) level (A, B, C, and D), and kaolin contamination conditions, and their leakage current, total leakage current, and component of the resistive leakage current were measured in order to diagnose arrester deterioration. The 3rd harmonics was larger than 5th and 7th ones for the arrester under the clean fog, and as the ESDD contamination level was applied, 5th one became relatively larger than 3rd one. Therefore, these results indicated that the resistive leakage current could be used for the diagnosis of the arresters.

Large Area Wafer-Level High-Power Electronic Package Using Temporary Bonding and Debonding with Double-Sided Thermal Release Tape (양면 열박리 테이프 기반 임시 접합 공정을 이용한 대면적 웨이퍼 레벨 고출력 전자패키지)

  • Hwang, Yong-Sik;Kang, Il-Suk;Lee, Ga-Won
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.36-40
    • /
    • 2022
  • High-power devices, such as LEDs and radars, inevitably generate a large amount of heat, which is the main cause of shortening lifespan, deterioration in performance, and failure of electronic devices. The embedded IC process can be a solution; however, when applied to large-area substrates (larger than 8 in), there is a limit owing to the difficulty in the process after wafer thinning. In this study, an 8-in wafer-level high-power electronic package based on the embedded IC process was implemented with temporary bonding and debonding technology using double-sided thermal release tape. Good heat-dissipation characteristics were demonstrated both theoretically and experimentally. These findings will advance the commercialization of high-power electronic packaging.

Analysis of Surface Contaminants and Deterioration Degree on the Seated Stone Statue of Buddhist Master Seungga at Seunggasa Temple in Seoul, Korea (승가사 석조승가대사좌상의 손상도 및 표면오염물 분석)

  • Kim, Sung Han;Lee, Chan Hee;Naruto, Araki
    • Economic and Environmental Geology
    • /
    • v.50 no.6
    • /
    • pp.497-508
    • /
    • 2017
  • This study was carried out to document and diagnose the conditions of the seated stone statue of Buddhist Master Seungga in Seunggasa temple immediately after its conservation treatment, which was found to be long covered in surface of white materials. The stone Halo was researched along with the Statue, and basic data was secured through precisely examination and nondestructive diagnosis. The result from the surface deterioration evaluation shows that both the Statue and Halo had a little bit of physical deterioration, although their level of chemical deterioration was proportionally higher due to discoloration. The physical property diagnosis using ultrasonic measurements on the Statue and Halo showed that the average ultrasonic velocity was found to be 3,570 m/s and 3,373 m/s, respectively, which corresponds to grade III, an indication of a favorable physical property. The surface covered materials were detected to be Ca, Ti, Pb, Fe, Al and Si, emanating from Hobun (Oster shell powder; $CaCO_3$) or lime ($CaO{\cdot}Ca(OH)_2$) and silicate minerals. Furthermore, Ti and Pb seems to be the component of the white coloring pigments, titanium white ($TiO_2$) and white lead ($2PbCO_2{\cdot}Pb(OH)_2$). Therefore, the seated stone statue of Buddhist Master Seungga is presumed to be painted with Hobun or lime and thereafter painted over with titanium white and white lead.

PD Source Detection of Oil Transformer Using Three-dimensional Construction (3차원 해석에 의한 유입변압기 PD발생점 탐지)

  • Yoon, Chul-Sub;Choi, Gil-Soo;Lee, Eun-Suk
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1036-1038
    • /
    • 1998
  • The while, PD source detection in the oil TR was the level of the planar source detection. and it is to respected scientific research. The planar source detection technique had limits which have difficulties finding out the point of deterioration generation. In this study, our purpose is a development of PD source detection technique with Three-Dimensional using a principle and a technique of the planar source location.

  • PDF

Study on Mutual Relation between the Level of Deterioration Influenced by the Changes of Chemical and Physical Properties and the Change of Dielectric Constant for Engine Oil - Gasoline Engine Oil (엔진오일의 화학적 및 물리적 변화에 의한 퇴화정도와 유전상수 변화에 관한 상호관계 연구 - 가솔린엔진오일)

  • Chun, Sang-Myung
    • Tribology and Lubricants
    • /
    • v.22 no.5
    • /
    • pp.260-268
    • /
    • 2006
  • The dielectric constants of used gasoline engine oils were obtained at a few temperatures and a frequency. Through analyzing the characteristics of dielectric constant, the related correlation between the changes in dielectric constants of oil and the degree of oil deterioration is going to be found. The dielectric constant was calculated using cross capacitances measured by a sensor tube. As results of the measurement of the fresh engine oil's dielectric constant, it was found that the value of dielectric constant was set down below $60^{\circ}C$ regardless changing frequency. Further, above 6 kHz, the dielectric constant was set down even if temperature was above $100^{\circ}C$ Therefore, for the measurement of used oils, it was selected the frequency of 6 kHz,,and the temperature of $80^{\circ}C$ preventing a certain ionic-conduction effects on the measured dielectric constant and the evaporation of a certain fluid mixed with engine oil. Specially, the effects of the mixing fluid like coolant, water and fuel on the fresh engine oil's dielectric constant were studied. It was found that the oil mixed with coolant showed the highest value, next water, and the lowest fuel. As results of the measurement of the used engine oil's dielectric constant, it was found that the possible changed rate of the used engine oil's dielectric constant based on the warning limit for engine oil in service was below 4% for gasoline engine oil.

Study on Mutual Relation between the Level of Deterioration Influenced by the Changes of Chemical and Physical Properties and the Change of Dielectric Constant for Engine Oil - Diesel Engine Oil (엔진오일의 화학적 및 물리적 변화에 의한 퇴화정도와 유전상수 변화에 관한 상호관계 연구 - 디젤엔진오일)

  • Chun, Sang-Myung
    • Tribology and Lubricants
    • /
    • v.22 no.5
    • /
    • pp.290-300
    • /
    • 2006
  • The dielectric constants of used diesel engine oils were obtained at a few temperatures and a frequency. Through analyzing the characteristics of dielectric constant, the related correlation between the changes in dielectric constants of oil and the degree of oil deterioration is going to be found. The dielectric constant was calculated using cross capacitances measured by a sensor tube. As results of the measurement of the fresh engine oil's dielectric constant, it was found that the value of dielectric constant was set down below $60^{\circ}C$ regardless changing frequency. Further, above 6 kHz, the dielectric constant was set down even if temperature was above $100^{\circ}C$. Therefore, for the measurement of used oils, it was selected the frequency of 6 kHz, and the temperature of $80^{\circ}C$ preventing a certain ionic-conduction effects on the measured dielectric constant and the evaporation of a certain fluid mixed with engine oil. Specially, the effects of the mixing fluid like coolant, water and fuel on the fresh engine oil's dielectric constant were studied. It was found that the oil mixed with coolant showed the highest value, next water, and the lowest fuel. As results of the measurement of the used engine oil's dielectric constant, it was found that the possible changed rate of the used engine oil's dielectric constant based on the warning limit for engine oil in service was below 10% for diesel engine oil.

Estimation of sewer deterioration by Weibull distribution function (와이블 분포함수를 이용한 하수관로 노후도 추정)

  • Kang, Byongjun;Yoo, Soonyu;Park, Kyoohong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.4
    • /
    • pp.251-258
    • /
    • 2020
  • Sewer deterioration models are needed to forecast the remaining life expectancy of sewer networks by assessing their conditions. In this study, the serious defect (or condition state 3) occurrence probability, at which sewer rehabilitation program should be implemented, was evaluated using four probability distribution functions such as normal, lognormal, exponential, and Weibull distribution. A sample of 252 km of CCTV-inspected sewer pipe data in city Z was collected in the first place. Then the effective data (284 sewer sections of 8.15 km) with reliable information were extracted and classified into 3 groups considering the sub-catchment area, sewer material, and sewer pipe size. Anderson-Darling test was conducted to select the most fitted probability distribution of sewer defect occurrence as Weibull distribution. The shape parameters (β) and scale parameters (η) of Weibull distribution were estimated from the data set of 3 classified groups, including standard errors, 95% confidence intervals, and log-likelihood values. The plot of probability density function and cumulative distribution function were obtained using the estimated parameter values, which could be used to indicate the quantitative level of risk on occurrence of CS3. It was estimated that sewer data group 1, group 2, and group 3 has CS3 occurrence probability exceeding 50% at 13th-year, 11th-year, and 16th-year after the installation, respectively. For every data groups, the time exceeding the CS3 occurrence probability of 90% was also predicted to be 27th- to 30th-year after the installation.

Assessment of interhospital transport care for pediatric patients

  • Chaichotjinda, Krittiya;Chantra, Marut;Pandee, Uthen
    • Clinical and Experimental Pediatrics
    • /
    • v.63 no.5
    • /
    • pp.184-188
    • /
    • 2020
  • Background: Many critically ill patients require transfer to a higher-level hospital for complex medical care. Despite the publication of the American Academy of Pediatrics guidelines for pediatric interhospital transportation services and the establishment of many pediatric transport programs, adverse events during pediatric transport still occur. Purpose: To determine the incidence of adverse events occurring during pediatric transport and explore their complications and risk factors. Methods: This prospective observational study explored the adverse events that occurred during the interhospital transport of all pediatric patients referred to the pediatric intensive care unit of Ramathibodi Hospital between March 2016 and June 2017. Results: There were 122 pediatric transports to the unit. Adverse events occurred in 25 cases (22%). Physiologic deterioration occurred in 15 patients (60%). Most issues (11 events) involved circulatory problems causing patient hypotension and poor tissue perfusion requiring fluid resuscitation or inotropic administration on arrival at the unit. Respiratory complications were the second most common cause (4 events). Equipment-related adverse events occurred in 5 patients (20%). The common causes were accidental extubation and endotracheal tube displacement. Five patients had both physiologic deterioration and equipment-related adverse events. Regarding transport personnel, the group without complications more often had a physician escort than the group with complications (92% vs. 76%; relative risk, 2.4; P=0.028). Conclusion: The incidence of adverse events occurring during the transport of critically ill pediatric patients was 22%. Most events involved physiological deterioration. Escort personnel maybe the key to preventing and appropriately monitoring complications occurring during transport.

Evaluation on De-Icing Salts Laden Environment of Road in Seoul (제설제에 노출된 서울시내 도로 시설물의 열화 환경 분석)

  • Yoon, In-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • De -icing salts have been used commonly in areas where snow or ice is a seasonal safety hazard for roadway, however, the salts is one of main causes on serious deterioration of road infrastructures in crowded urban city like Seoul. In order to establish maintenance strategy of road infrastructures under de-icing salts laden environment, it is necessary to examine environmental characteristics and its response to the existing facilities. The purpose of this study is to evaluate the deterioration environment of road infrastructures. Additional purpose is to develop a design model and details for durability design of infrastructures under de-icing salts laden environment, considering mainly a build-up rate of surface chlorides. Concentration of external chloride solution and surface chloride content were calculated at the level of average de-icing salts for 5 years, ratio of auxiliary road of 17.5 to 30%, and effective exposure area to snow 50 to 80%. The chloride build-up rate was 0.073 ~ 0.077% / year and the maximum surface chloride content was calculated to be 2.2 ~ 2.31% by concrete wt. This study is expected to be used for establishing integrated strategy of road infrastructures, such as predicting chloride profiles or degree of chemical corrosion to exposure concrete.