• 제목/요약/키워드: deterioration level

검색결과 521건 처리시간 0.023초

오일필터 일체형 엔진오일퇴화감지센서 시작품 개발 I (The Prototype Development of an Engine Oil Deterioration Sensor Installed Inside an Oil Filter)

  • 전상명
    • Tribology and Lubricants
    • /
    • 제24권2호
    • /
    • pp.82-89
    • /
    • 2008
  • The purpose of this study is to develop the proto type sensor installed inside an oil filter in order to detect oil deterioration level. The sensor is made up with two concentric cylinders with constant gap in between and a filter element inside the central area. The size will be designed as similar as real oil filters. The sensor will be tested on a test rig, which is circulating engine oil, with the same size of an oil filter adapting housing as real engines'. It will be measured the capacitance of a sample engine oil, then be able to be gotten the dielectric constant. The changes in the dielectric constant could be correlated with the engine oil deterioration level if the sensor development would be completed. In this paper, it will be shown the test results carrying out under variable temperature conditions at atmosphere pressure.

트럭 공차중량, 중앙분리대 피복두께 및 열화수준에 따른 중앙분리대 충돌해석모델의 민감도 분석 (Evaluation of Impact Resistance for Concrete Median Barrier Depending on Vehicle Curb Weight, Concrete Cover Depth and Level of Deterioration)

  • 이재하;이일근;정유석;김경진;김우석
    • 한국전산구조공학회논문집
    • /
    • 제30권4호
    • /
    • pp.297-306
    • /
    • 2017
  • 국내 고속도로 콘크리트 중앙분리대는 SB5-B(270kJ)의 충돌등급에 저항하도록 설계되어 있다. 그러나 최근 대형 화물차량의 충돌사고가 지속적으로 증가하는 경향을 보이고 있어 SB6(420kJ) 등급으로의 상향이 필요하다. 충돌등급 상향을 위한 새로운 중앙분리대 단면을 제시하기 위해서는 실제 충돌시험을 수행하여 기준 통과여부를 결정하며, 충돌시험 수행을 위한 적정 단면을 제시하기 위해서는 충돌해석을 통해 선정한다. 이러한 충돌해석의 정확도 향상을 위해서는 차량 모델, 콘크리트 단면 열화상태, 콘크리트 피복 두께 등 다양한 변수에 대한 정확한 변수 선정이 필요하다. 따라서 본 연구에서는 공차 중량, 단면 열화, 콘크리트 피복 두께에 대한 변수연구를 수행하여 충돌저항성능 저감을 확인하였다. 전체 중량뿐만 아닌 공차 중량에 따라 중앙분리대의 충돌저항성능에 차이가 있는 것으로 확인되었으며, 10cm 이하의 콘크리트 피복 두께에서는 충돌저항성능이 민감하게 증가 또는 감소한다. 단면 열화가 발생할 경우 중앙분리대의 충돌저항성능의 감소가 발생하여 열화정도에 따른 보수 및 보강이 이루어져야 하는 것으로 판단된다. 따라서 콘크리트 구조물과 차량의 충돌해석을 수행할 경우 트럭의 공차중량 비율, 콘크리트의 피복두께 및 열화에 대한 영향이 상세하게 고려될 필요가 있음을 확인하였다.

Replacement Policy for Equipments that Cumulatively Deteriorate

  • Yun Deok K.;Park Kyung S.
    • 한국국방경영분석학회지
    • /
    • 제7권2호
    • /
    • pp.100-113
    • /
    • 1981
  • A replacement policy for a finite time span is proposed for the cumulative process where an item can fail only when the total amount of deterioration exceeds a prespecified failure level. The optimal deterioration limit level is determined to minimize the total cost expected per unit for a given time span. An illustrative example in case of periodically inspected reformer tubes in ammonia plant is also presented.

  • PDF

대형디젤기관에서 바이오디젤 열화와 엔진부하에 따른 배출가스특성 및 성능에 관한 연구 (Study on Performance and An Exhaust Emission by Bio-Diesel Deterioration and Engine Load Rate at Heavy-Duty Diesel Engine)

  • 박만재;김미수
    • 한국공작기계학회논문집
    • /
    • 제16권3호
    • /
    • pp.56-63
    • /
    • 2007
  • Modern diesel vehicle has to comply with the EURO IV, V regulation with low level of particulate matter and smoke emission Moreover, emission standards of each countries are becoming stringent in advanced countries such as USA and Europe. Because Bio-diesel is similar to diesel fuel, it is essential to judge the environmental and health effects deriving from the use of Bio-diesel in diesel engine. The deterioration characteristics of emission in accordance with aging vehicles must be regulated for Bio-diesel. Therefore, under 1200 driving hours, 220,000km driving distance condition and full load, the deterioration characteristics of emission were estimated. We could reduce sulfur contents of fuel, particulate matter and smoke emission by using Bio-diesel and conform the influence of engine performance, emission, and fuel consumption by Bio-diesel deterioration

딥스틱게이지형 소형 엔진열화감지센서 개발 (Development of a Dipstick Gage Type Small Engine oil Deterioration Detection Sensor)

  • 전상명
    • Tribology and Lubricants
    • /
    • 제29권2호
    • /
    • pp.77-84
    • /
    • 2013
  • A small engine-oil-deterioration detection sensor was developed and installed at the tip of a dipstick gage. The sensor part was manufactured using printed circuit board (PCB) manufacturing technology. A set of sensor covers was installed in order to protect the sensor and realize good signal stability. The small engine-oil-deterioration detection sensor system comprised a dual sensor having etched copper electrodes coated with gold and ceramic, a flexible PCB (FPCB) acting as electric wire, and a dummy PCB with only a lock connector. The sensor can easily be installed by insertion through the guide tube of a dipstick gage. Thus, a driver can easily handle it without further installation equipment. The sensor can determine the level of deterioration in the engine oil by estimating the corresponding dielectric constant of the engine oil.

AN ECONOMIC PRODUCTION QUANTITY INVENTORY MODEL INVOLVING FUZZY DEMAND RATE AND FUZZY DETERIORATION RATE

  • De, Sujit-Kumar;A. Goswami;P.K. Kundu
    • Journal of applied mathematics & informatics
    • /
    • 제12권1_2호
    • /
    • pp.251-260
    • /
    • 2003
  • Generally, in deriving the solution of economic production quantity (EPQ) inventory model, we consider the demand rate and deterioration rate as constant quantity. But in case of real life problems, the demand rate and deterioration rate are not actually constant but slightly disturbed from their original crisp value. The motivation of this paper is to consider a more realistic EPQ inventory model with finite production rate, fuzzy demand rate and fuzzy deterioration rate. The effect of the loss in production quantity due to faulty/old machine have also been taken into consideration. The methodology to obtain the optimum value of the fuzzy total cost is derived and a numerical example is used to illustrate the computation procedure. A sensitivity analysis is also carried out to get the sensitiveness of the tolarance of different input parameters.

공정의 열화를 고려한 경제적 관리한계 결정 (A determination of economic control limits considering process deterioration)

  • 심윤보;김성집
    • 산업경영시스템학회지
    • /
    • 제21권45호
    • /
    • pp.237-246
    • /
    • 1998
  • In most statistical process control(SPC), control charts are used in which samples are taken and a suitable statistic is determined and plotted. In these control charts, control limits, ${\mu}{\pm}textsc{k{\sigma}}$, from which a decision is made are mostly ${\mu}{\pm}3{\sigma}$ and current literature in control charts are mainly concerned with detecting a shift in the mean. Therefore, when $\sigma$ is increased considerably after a long time, using control limits set at the first time causes a great deal of economic loss. In this paper the solutions to determine new control limits which maximizes the profit per unit produced and reduce $\sigma$ to economically optimal level for a certain cost when $\sigma$ is increased due to process deterioration are proposed. By applying new control limits, $\alpha$ error decreases considerably compared to apply initial control limits when $\sigma$ is increased due to process deterioration. Therefore, false alarm investigation cost drops down to the level of initial a error. And also this solution provides useful information regarding replacement of a process when the process is reviewed regularly.

  • PDF

Numerical Comparison of Thermalhydraulic Aspects of Supercritical Carbon Dioxide and Subcritical Water-Based Natural Circulation Loop

  • Sarkar, Milan Krishna Singha;Basu, Dipankar Narayan
    • Nuclear Engineering and Technology
    • /
    • 제49권1호
    • /
    • pp.103-112
    • /
    • 2017
  • Application of the supercritical condition in reactor core cooling needs to be properly justified based on the extreme level of parameters involved. Therefore, a numerical study is presented to compare the thermalhydraulic performance of supercritical and single-phase natural circulation loops under low-to-intermediate power levels. Carbon dioxide and water are selected as respective working fluids, operating under an identical set of conditions. Accordingly, a three-dimensional computational model was developed, and solved with an appropriate turbulence model and equations of state. Large asymmetry in velocity and temperature profiles was observed in a single cross section due to local buoyancy effect, which is more prominent for supercritical fluids. Mass flow rate in a supercritical loop increases with power until a maximum is reached, which subsequently corresponds to a rapid deterioration in heat transfer coefficient. That can be identified as the limit of operation for such loops to avoid a high temperature, and therefore, the use of a supercritical loop is suggested only until the appearance of such maxima. Flow-induced heat transfer deterioration can be delayed by increasing system pressure or lowering sink temperature. Bulk temperature level throughout the loop with water as working fluid is higher than supercritical carbon dioxide. This is until the heat transfer deterioration, and hence the use of a single-phase loop is prescribed beyond that limit.

철근부식에 의한 철근콘크리트골조의 구조성능분석 (Structural Performance Investigation for the Reinforced Concrete Frames Deteriorated by the Reinforcement Corrosion)

  • 최세운
    • 한국전산구조공학회논문집
    • /
    • 제28권5호
    • /
    • pp.563-570
    • /
    • 2015
  • 기존 구조물의 손상평가에 관한 연구는 지진 등과 같은 과도한 하중에 의한 손상을 고려하였다. 그러나 구조물은 과도한 하중없이도 장기간의 시간에 따라 염화물, 탄성화 등과 같은 이유로 노후화가 진행되어 구조성능이 저하될 수 있다. 그래서 구조물의 건전도를 효과적으로 관리하기 위해서는 노후화에 의한 구조성능 저하도 검토되어야 한다. 본 연구에서는 염화물에 의한 철근의 부식을 노후화 요인으로 고려한다. 철근부식에 의한 재료의 구조성능 저하를 고려하기 위해 부식정도에 따른 철근의 단면적, 항복강도, 파단변형률, 피복 콘크리트 강도 등을 예측한다. 이를 구조모델링에 적용하여 구조부재 및 구조물의 구조성능 저하를 분석한다. 구조부재의 구조성능을 분석하기 위해 모멘트-곡률 해석을 수행한다. 구조물 레벨의 구조성능을 고려하기 위해, 고유치해석을 통한 고유주기와 모드형상을 분석한다. 또한 비선형 정적해석을 통해 구조물의 강도와 변형성능을 분석한다.

Clarification the Current Situation of Deterioration and Its Causes of Modernization Heritage Built with Bricks in Japan: A Case Study of Long-Term Monitoring Investigation at Sarushima Battery, Yokosuka, Japan

  • Fukami, Risako;Matsui, Toshiya;Kawamoto, Mayumi
    • 보존과학회지
    • /
    • 제38권4호
    • /
    • pp.265-276
    • /
    • 2022
  • A long-term monitoring investigation at Sarushima Battery (Kanagawa, Japan), which is one of the modernization heritages was conducted from 2017.06 to 2020.12. The investigation of the temperature and relative humidity (RH), measurement of the amount of brick decay, and X-ray diffraction analysis of the brick decay was conducted to understand in detail the environment in which the historical brick structure, the state of deterioration, identify the factors of deterioration. Furthermore, it was discussed whether the suitability of these investigation methods for assessing the status, identifying the level of deterioration and the factors that led to deterioration at the historical brick heritages. It was found that the brick deterioration at the site progressed especially in two periods: in April, and from June to August. These periods coincided with the period when the RH inside the structure decreased, and the Toyo-gumi bricks were in the process of absorbing moisture. Several different types of salts were detected in brick decay, especially thenardite, which is considered highly hazardous and destructive during periods when the amount of brick decay increased. Therefore, the RH in the structure and the salts present in the bricks were identified as one of the factors in the deterioration of the bricks at the site. The methods used in this study are appropriate as the initial survey methods for investigating the current conditions and identifying the causes of deterioration because it is possible to understand the environment within the modernization heritages, grasp the details of deterioration progression, and identify the characteristics of deterioration progression and its factors through long-term investigation using the simple methods.