Evaluation of Design Parameter on Residuals Treatment Facilities in Membrane Water Treatment Plants (막여과 정수장에서의 배출수처리시설 설계인자 평가)

  • Moon, Yong-Taik;Seo, In-Seok;Kim, Hong-Suck;Park, No-Suk;Ahn, Hyo-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.138-146
    • /
    • 2006
  • The characteristics of backwash and concentrate discharges depend upon the quality of the water being treated and the net recovery of the membrane system. This paper is to indicate a design methods on the capacities of residuals treatment facilities in membrane processes for drinking water. We operated a demonstration membrane plant with a recovery rate of 90% for designing G-water treatment plant. We investigated on design parameter (optimum coagulant dosage and surface loading rate etc.) to design efficiently the residuals treatment facilities. The settling test was conducted with 1m columns dosing PACl to kaolin and membrane residuals under the experimental condition that discharge permit was under a 60mg/L. When the quantity of membrane residuals was $1,575m^3/day$, the estimated results for 1st thickener demonstrated the surface loading rate of 14.4m/day, detention time of 5.83hr, available depth of 3.5m.

A Study on Process Improvement for Reduction of Pollution Loading Rate in Small Individual Sewage Plant (소규모 개인하수처리시설의 MBR공정 적용에 관한 연구)

  • Eom, Han Ki;Choi, Yoo Hyun;Joo, Hyun Jong
    • Journal of Environmental Science International
    • /
    • v.25 no.2
    • /
    • pp.323-329
    • /
    • 2016
  • In this study, the applicability of MBR process was evaluated to improve processing of personal sewage treatment facilities of $50m^3/day$ or less. As result of the research, stable discharge water quality could be secured as result of the MBR effector operation according to rate of inflow and inflow load and treatment efficiency of 98% or higher was shown by the membrane filtering method operation for SS, $BOD_5$. it was found that high treatment efficiency of 99% or higher. It is judged that detention time can be designed until 6.9 hr when applying MBR process on personal sewage treatment facilities with high pollution load and that cutback of pollution load can be possible through this study. It was shown that MBR process application reduces an annual cost of 4,829,600 won based on the basic unit calculation results and solves burden of amount of borne by causers according to excess of discharge water quality standards.

Nitrogen Removal Rate of Free-Water-Surface Treatment Wetland System Constructed on Floodplain During Its Initial Operating Stage (고수부지에 조성한 수질정화 자유수면습지의 초기운영단계 질소제거)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.6
    • /
    • pp.41-48
    • /
    • 2003
  • Nitrogen removal rate and emergent plant growth were investigated of a free-water-surface constructed treatment wetland system, whose dimensions were 31m in length and 12m in width. The system was constructed on floodplain in the Kwangju Stream from May to June 2001. Cattails(Typha angustifolia) were transplanted from natural wetlands and their stems were cut at about 40cm height from their bottom ends. Water of the Kwangju Stream were funneled into the system by gravity flow and its treated effluent was discharged back into the stream. The average height of the cattail stems was 45.2cm in July 2001 and 186cm in October 2001. The number of stems averaged 22 stems/$m^2$ in July 2001 and 52 stems/$m^2$ in September 2001. Volume and water quality of inflow and outflow were analyzed from July 2001 through December 2001. Inflow and outflow averaged 40.01 and 39.55 $m^3$/day, respectively. Hydraulic detention time was about 1.5 days. Average nitrogen uptake by cattails was 69.31 $N\;mg\;m^{-2}\;day^{-1}$. Removal rate of $NO_3-N$, $NH_3-N$ and T-N averaged 195.58, 53.65 and 628.44 $mg\;m^{-2}\;day^{-1}$, respectively. The average removal rate of T-N was about 39%.

The Evaluation of Performance Limiting Factors for the Optimization of Drinking Water Treatment (정수장 최적화를 위한 성능제한인자 평가에 관한 연구)

  • Kim, Jeong Hyun;Bae, Chul Ho;Park, No Suk;Moon, Yong Taik;Lee, Sun Ju;Kown, Soon Buhm;Ahn, Hyo Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.78-91
    • /
    • 2005
  • Performance limiting factors (PLFs) derived from 161 drinking water treatment plants (DWTPs), assessed by International Technical Diagnosis & Assistance Center, were analyzed and evaluated in more detail in this study. In order to conduct study, 161 DWTPs were divided into five categories depending on their capacity, and into twelve groups according to processes and facilities. From the results of analysis, PLFs and their distribution ratio derived from each category were significantly different. Filtration was the most important performance limiting process in all DWTPs of five categories, and the PLFs in filtration were backwashing velocity, media configuration, bed depth, and formation of mud-ball. The PLFs in coagulation-flocculation process were found out to be coagulant dosage, mixing speed, mechanical problems, and others in the order of frequency of occurrence. Also, insufficient disinfection ability that is resulted from insufficient hydraulic detention time and improper chlorine dose and injection point, is the most significant among PLFs in a clear well. In the case of sedimentation, inappropriate baffle structure and excessive upward velocity were PLFs. In addition, the results showed that high turbid water and low alkalinity in a rainy season, ferric and manganese ions, and ammonia nitrogen have been contributed significantly on the performance of DWTPs.

Uncertainty of Evaluating Design Flood and Mitigation Plan at Downstream of Imjin River (감조하천 홍수위 계산의 불확실성과 저감 대안 - 임진강 하류를 대상으로)

  • Baek, Kyong Oh;Kwon, Hyek Won
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.132-137
    • /
    • 2018
  • Compared with general rivers, fluctuations of the water level and the river bed are severe in the tidal river. In hydro-dynamic aspect, such fluctuation gives different river-bed data to us according to observing period. The time-dependent river-bed data and pre-estimation of the Manning's roughness coefficient which is the key factor of numerical modelling induces uncertainty of evaluating the design flood level. Thus it is necessary to pay more attention to calculate the flood level at tidal rivers than at general rivers. In this study, downstream of the Imjin River where is affected by tide of the West Sea selected as a study site. From the numerical modelling, it was shown that the unsteady simulation gave considerable mitigation of the water level from the starting point to 15 km upstream compared to the steady simulation. Either making a detention pond or optional dredging was not effective to mitigate the flood level at Gugok - Majung region where is located in the downstream of the Imjin River. Therefore, a more sophisticated approach is required to evaluate the design flood level estimation before constructive measures adopted in general rivers when establishing the flood control plan in a tidal river.

Numerical Investigation on Capture of Sub-Micron particles in Electrostatic Precipitator without Corona Discharger (코로나 방전기가 없는 전기집진기의 미세입자 집진에 관한 수치해석)

  • Lee, Jin-Woon;Jang, Jae-Sung;Lee, Seong-Hyuk
    • Journal of ILASS-Korea
    • /
    • v.16 no.2
    • /
    • pp.69-75
    • /
    • 2011
  • This article presents computational fluid dynamics (CFD) simulations of sub-micron particle movements and flow characteristics in laboratory-scale electrostatic precipitator (ESP) without corona discharge, and for simulation, it uses the commercial CFD program (CFD-ACE) including electrostatic theory and Lagrangian-based equation for sub-micron particle movement. For validation of CFD results, a simple cylindrical type of ESP is simulated and numerical prediction shows fairly good agreement with the analytical solution. In particular, the present study investigates the effect of particle diameter, inlet flow rate, and applied electric potential on particle collection efficiency and compares the numerical prediction with the experimental data, showing good agreement. It is found that the particle collection efficiency decreases with increasing inlet flow rate because the particle detention time becomes shorter, whereas it decreases with the increase in sub-micron particle diameter and with the decrease of applied electric voltage resulting from smaller terminal electrostatic velocity.

Characteristics of Biodegradation of Organic Matters in the Nakdong River Watershed (낙동강 수계 내 유기물 시료에 따른 생분해 특성)

  • Kim, Jung Sun;Kang, Lim Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.6
    • /
    • pp.605-611
    • /
    • 2014
  • This research was carried out to examine the concentration and fate of dissolved organic matter due to the increased detention time in middle and down stream of the Nakdong River. Aldo the characteristics of biodegradation of DOM were investigated according to the various water sources. The approaches used to characterize DOM biodegradability include the changes in DOC concentration and DOM fraction. Long-term biodegradation test for each organic source was also conducted. As the result, maximum 50% of DOC was reduced during the first 30 days of biodegradation tests. After 30 days, biodegradation of organic matter was continuously progressed, as showing continuous reduction of DOC. While DOC concentration was reduced, SUVA values for the organic matters were increased. Properties of dissolved organic matter by water sources also showed decreasing hydrophilic components while showing increased hydrophobic components. The more rapid reduction of the hydrophilic components than hydrophobic components might be due to the preferential degradation of the hydrophilic components by microorganisms during biodegradation process.

A New Control Technique of Drainage Pump Based on Fuzzy Control (퍼지제어기법을 사용한 우수배제 펌프의 조작기법 개발)

  • Lee, Won Hwan;Cho, Won Cheol;Shim, Jae Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.107-114
    • /
    • 1992
  • With the increasing of impervious area and shortening of travel time, the risk of flooding in urban area becomes a serious problem in Seoul metropolitan area, and its alternatives are needed. In this study, one of urban flood alternatives, a fuzzy control technique is applied in pumping station to test its drainage capacity of inland inflow, and compared with existing pumping criteria (controled by water level). Three design rainfalls(10, 30, and 50 year) are applied to ILLUDAS model to calculate inflow in detention reservoir. To check the efficiency of fuzzy control, two fuzzy rules are used in the operation of pumping station. In these results, fuzzy control rules, based on the experiences of experts, show applicability in practice and effectiveness in inland flooding prevention.

  • PDF

Pollutant Removal Efficiency of Sedimentation Basin at Inlet of an Irrigation Reservoir (저수지 내 유입부 침강지의 수질정화 효율)

  • Jang, Jeong-Ryeol;Choi, Sun-Hwa;Kwun, Soon-Kuk
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.473-479
    • /
    • 2004
  • A sedimentation basin (SB) at the inlet of an irrigation reservoir which was constructed using an auxiliary dam was monitored to evaluate its pollutant removal efficiency. Water sampling at three points, i.e., inflow stream, upstream and downstream of the reservoir, were taken 5 times before and after the construction of the SB in 1999 and 2003, respectively. No significant water quality variations in inflow stream were observed during these periods. The COD, T-N, T-P and SS removal efficiencies were 38, 24, 35 and 49%, respectively. The results indicated that those removal efficiencies significantly increased during the rainy season and COD removal efficiency, especially, was higher than others studies. The scale of SB in this study was rational as aspects of pollutant removal efficiency and hydraulic detention time. And it is recommended that SB, at inlet of an reservoir, should be constructed as completely separated structure from reservoir water body and having SAR Index from 0.7% to 1.0%.

Biofiltration of Ammonia Gas from Composting Using Sawdust as Biofilter Media (퇴비화 암모니아 가스의 톱밥 바이오 필터 매체에 의한 생물학적 탈취)

  • Hong Ji Hyung;Park Keum Joo
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.107-115
    • /
    • 2003
  • Dairy manure amended with crop and forest residues (moisture 69% wet basis, C/N 22) was composted in a 605 L pilot-scale vessel using continuous air flow (56 L/min) for 19 days. Three pilot-scale sawdust biofilters (moisture 63%, pH 5.0) were built to clean biological waste gas from the composting process. For each methods, two replicated experiments were monitored over a period of three weeks. The system was evaluated to determine the biofilter media depth that would be adequate for compost odour reduction. The compost air cleaning was measured based on ammonia gas concentration before and after passing through the biofilter. Ammonia gas removal efficiency over 3 weeks was 42, 75 and 87% at sawdust biofilter media depth levels of 202, 400 and 600 mm, respectively. Each sawdust biofilter was operated at a moisture content in the range of 60~62% (wb), a temperature from 15 to $25^{\circ}C$, an average pressure drop from 240 to 340 Pa and a detention time from 60 to 180 seconds during the biofiltration process.