• Title/Summary/Keyword: detectors

검색결과 1,435건 처리시간 0.028초

대규모 시설을 위한 다채널 가스 누설 경보기 개발 (Development of Multi Channel Gas Leakage Detector for Large Facility)

  • 정규원
    • 한국안전학회지
    • /
    • 제23권3호
    • /
    • pp.1-7
    • /
    • 2008
  • As a clean fuel, LNG or LPG is widely used in large restaurants or plants instead of coal. These fuels are easy to use and cheap. However, they are inflammable very much and easily exploded at the worst. So there are many laws and regulations legislated for the handling and usage of the gas facilities. Nevertheless, very harsh explosions occurred in several domestic or foreign places. In this paper a gas detection and alarm system was developed for large facilities. A new concept for connecting many gas detectors was proposed and based upon that a system including hardware and software have been developed and tested. Although up to 16 gas detectors apart 1 km from main controller can be connected currently, this system can be easily expanded for more detectors because each gas detector receiver communicates with main controller using industrial standard RS-485 multi drop technique. Furthermore several additive functions was included for the installation and maintenance convenience.

실시간신호제어를 위한 차량검지기 정보의 신뢰성 비교평가 (A Comparative Evaluation of Confidence of Vehicle-Dectetor Informations for Real-Time Traffic Signal Control.)

  • 오영태;이철기
    • 대한교통학회지
    • /
    • 제14권3호
    • /
    • pp.91-125
    • /
    • 1996
  • The purpose of this paper is comparatively to evaluate the confidence of Vehicle-Detector informations for various detectors in order to test to be possible the application of these to real time traffic signal control. The detectors which are tested for this study are Circle-Shaped Loop, Ultrasonic, Microwave and Image detector. The tested items for each detectors are traffic volume, degree of saturation for through and left turn movement, speed and queue length, etc. These items for each are tested at the field according to several situations, such as dry day, raining day, night and daytime. The result of these tests are performed comparative analysis and statistical examination in order to increase the confidence of the experiments.

  • PDF

마이크로프로세서를 사용한 UV/IR 불곶 감지기 (UV/IR flame detector using Microprocessor)

  • 박성진;임병현;임종연;김명원;윤길호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.215-218
    • /
    • 2001
  • A flame detector responds either to radiant energy visible to the human eye or outside the range of human vision. Such a detector is sensitive to glowing embers, coals, or flames which radiate energy of sufficient intensity and spectral quality to actuate the alarm. An infra-red detectors can respond to the total IR component of the flame alone or in combination with flame flicker in the frequency range of 5 to 30 Hz. A major problem in the use of infrared detectors receiving total IR radiation is the possible interference of solar radiation in the infrared region. When detectors are located in places shielded from the sun, such as vaults. filtering or shielding the unit from the sun's rays is unnecessary. In this study, we proposed method for redue a false alarm with using filtering & sensor technology for distinguish of causes of raise a false alarm and pure flame.

  • PDF

THIN-FILM-COATED DETECTORS FOR NEUTRON DETECTION

  • McGregor Douglas S.;Gersch Holly K.;Sanders Jeffrey D.;Klann Raymond T.;Lindsay John T.
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.167-175
    • /
    • 2001
  • Semiconductor diode detectors coated with neutron reactive material are presently under investigation for various uses, such as remote sensing of thermal neutrons, fast neutron counting, and thermal neutron radiography. Theory indicates that single-coated devices can yield thermal neutron efficiencies from 4% to 11 %, which is supported by experimental evidence. Radiation endurance measurements indicate that the devices function well up to a limiting thermal neutron fluence of $10^{13}/cm^2$, beyond which noticeable degradation occurs. Thermal neutron contrast images of step wedges and simple phantoms, taken with dual in-line pixel devices, show promise for thermal neutron imaging detectors.

  • PDF

IMPROVING REGIONAL OVERPOWER PROTECTION TRIP SET POINT VIA CHANNEL OPTIMIZATION

  • Kastanya, Doddy
    • Nuclear Engineering and Technology
    • /
    • 제44권7호
    • /
    • pp.799-806
    • /
    • 2012
  • In recent years, a new algorithm has been introduced to perform the regional overpower protection (ROP) detector layout optimization for $CANDU^{(R)}$ reactors. This algorithm is called DETPLASA. This algorithm has been shown to successfully come up with a detector layout which meets the target trip set point (TSP) value. Knowing that these ROP detectors are placed in a number of safety channels, one expects that there is an optimal placement of the candidate detectors into these channels. The objective of the present paper is to show that a slight improvement to the TSP value can be realized by optimizing the channelization of these ROP detectors. Depending on the size of the ROP system, based on numerical experiments performed in this study, the range of additional TSP improvement is from 0.16%FP (full power) to 0.56%FP.

광섬유 출력 측정용 광검출기의 비선형성 평가 연구 (Nonlinear characteristics of photodetectors for optical fiber power measurements)

  • 이덕희;류지욱;서정철
    • 한국광학회지
    • /
    • 제15권4호
    • /
    • pp.321-324
    • /
    • 2004
  • 광통신 출력 측정용 광검출기의 비선형성 특성을 측정하기 위하여 광합산 방법을 이용한 비선형성 측정 장치를 구성하였다. KRISS 출력 소급성을 갖는 고출력용 광검출기와 저출력용 광검출기의 비선형성을 측정하였는데, 50 ㏈의 작동영역에서 각 검출기의 비선형성은 0.01% 및 0.02% 이내로 측정되었다. 이 광검출기들은 선형성이 우수하므로 광섬유 광특성 측정 분야에서 KRISS 표준기로 사용되고 있다.

연기감지기의 내식시험에 관한 연구 (A Study on the Corrosion Resistance Test of Smoke Detectors)

  • 김형권;윤헌주;권성필;사공성호;백창선
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.155-158
    • /
    • 2008
  • In this study we compared corrosion resistance tests which were carried out according to the national technique standard and the UL standard to ensure the reliability of smoke detectors in foul weather. The sensitivity of smoke detectors became so blunt that the least operational smoke concentration was a maximum change of 13% in the national technique standard, while it was a maximum change of 145% in the UL standard. As a result of this study the test method of corrosion resistance was made an objective evaluation in the national technique standard. Therefore it could be said that a basis of developing the test method of corrosion resistance was prepared for our country.

  • PDF

Transient Photocurrent in Amorphous Silicon Radiation Detectors

  • Lee, Hyoung-Koo;Suh, Tae-Suk;Choe, Bo-Young;Shinn, Kyung-Sub;Cho, Gyu-Seong
    • Nuclear Engineering and Technology
    • /
    • 제29권6호
    • /
    • pp.468-475
    • /
    • 1997
  • The transient photocurrent in amorphous silicon radiation detectors (n-i-n and forward biased p-i-n) were analyzed. The transient photocurrents in these devices could be modeled using multiple trap levels in the forbidden gap. Using this model the rise and decay shapes of the photocurrents could be fitted. The decaying photocurrent shapes of the p-i-n and n-i-n devices after a short duration of light pulse showed a similar behavior at low dark current density levels, but at higher dark current density levels the photocurrent of the p-i-n diode decayed faster than that of the n-i-n, which could be explained by the decreased electron lifetimes in the forward biased p-i-n diode at high dark current densities. The transient photoconductive gain behaviors in the amorphous silicon radiation detectors are discussed in terms of device configuration, dark current density and time scale.

  • PDF

Efficient detectors for MIMO-OFDM systems under spatial correlation antenna arrays

  • Guerra, David William Marques;Fukuda, Rafael Masashi;Kobayashi, Ricardo Tadashi;Abrao, Taufik
    • ETRI Journal
    • /
    • 제40권5호
    • /
    • pp.570-581
    • /
    • 2018
  • This work analyzes the performance of implementable detectors for the multiple-input multiple-output (MIMO) orthogonal frequency division multiplexing (OFDM) technique under specific and realistic operation system conditions, including antenna correlation and array configuration. A time-domain channel model was used to evaluate the system performance under realistic communication channel and system scenarios, including different channel correlation, modulation order, and antenna array configurations. Several MIMO-OFDM detectors were analyzed for the purpose of achieving high performance combined with high capacity systems and manageable computational complexity. Numerical Monte Carlo simulations demonstrate the channel selectivity effect, while the impact of the number of antennas, adoption of linear against heuristic-based detection schemes, and the spatial correlation effect under linear and planar antenna arrays are analyzed in the MIMO-OFDM context.

Efficient Training Sequence Structure for Adaptive Linear Multiuser Detectors in Space-Time Block Coded Multiuser Systems

  • Hwang Hyeon Chyeol;Shin Seung Hoon;Seok Hyun Taek;Lee Hyung Ki;Yoo Dong Kwan;Kwak Kyung Sup
    • 한국통신학회논문지
    • /
    • 제30권6C호
    • /
    • pp.481-489
    • /
    • 2005
  • In this letter, we propose an efficient training sequence structure for adaptive linear multiuser detectors in space-time block coded multiuser systems, by exploiting a particular property of the minimum mean square error multiuser detectors used in these systems. The proposed structure wastes less overall system capacity than the straightforward training structure, without any corresponding loss of performance, as confirmed by the simulation results.