• Title/Summary/Keyword: detector data

Search Result 1,144, Processing Time 0.028 seconds

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF

Application of Off-axis Correction Method for EPID Based IMRT QA (EPID를 사용한 세기조절방사선치료의 정도관리에 있어 축이탈 보정(Off-axis Correction)의 적용)

  • Cho, Ilsung;Kwark, Jungwon;Park, Sung Ho;Ahn, Seung Do;Jeong, Dong Hyeok;Cho, Byungchul
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.317-325
    • /
    • 2012
  • The Varian PORTALVISION (Varian Medical Systems, US) shows significant overresponses as the off-center distance increases compared to the predicted dose. In order to correct the dose discrepancy, the off-axis correction is applied to VARIAN iX linear accelerators. The portal dose for $38{\times}28cm^2$ open field is acquired for 6 MV, 15 MV photon beams and also are predicted by PDIP algorithm under the same condition of the portal dose acquisition. The off-axis correction is applied by modifying the $40{\times}40cm^2$ diagonal beam profile data which is used for the beam profile calibration. The ratios between predicted dose and measured dose is modeled as a function of off-axis distance with the $4^{th}$ polynomial and is applied to the $40{\times}40cm^2$ diagonal beam profile data as the weight to correct measured dose by EPID detector. The discrepancy between measured dose and predicted dose is reduced from $4.17{\pm}2.76$ CU to $0.18{\pm}0.8$ CU for 6 MV photon beam and from $3.23{\pm}2.59$ CU to $0.04{\pm}0.85$ CU for 15 MV photon beam. The passing rate of gamma analysis for the pyramid fluence patten with the 4%, 4 mm criteria is improved from 98.7% to 99.1% for 6 MV photon beam, from 99.8% to 99.9% for 15 MV photon beam. IMRT QA is also performed for randomly selected Head and Neck and Prostate IMRT plans after applying the off-axis correction. The gamma passing rare is improved by 3% on average, for Head and Neck cases: $94.7{\pm}3.2%$ to $98.2{\pm}1.4%$, for Prostate cases: $95.5{\pm}2.6%$, $98.4{\pm}1.8%$. The gamma analysis criteria is 3%, 3 mm with 10% threshold. It is considered that the off-axis correction might be an effective and easily adaptable means for correcting the discrepancy between measured dose and predicted dose for IMRT QA using EPID in clinic.

Survey on the Content and Intake Pattern of Sugar from Elementary and Middle School Foodservices in Daejeon and Chungcheong Province (대전.충청지역 초.중학교 급식의 당 함량 및 급식을 통한 당류의 섭취실태 연구)

  • Park, You-Gyoung;Lee, Eun-Mi;Kim, Chang-Soo;Eom, Joon-Ho;Byun, Jung-A;Sun, Nam-Kyu;Lee, Jin-Ha;Heo, Ok-Soon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.10
    • /
    • pp.1545-1554
    • /
    • 2010
  • Korean government will set up the nationwide food safety system with strict control of hazardous nutrients like sugar, fatty acids and sodium as well as advanced nutrition education system. In addition, almost one hundred percent of school food service rate forced the government to consider more effective ways to upgrade the nutritional status of school meals. The object of our study was to provide the data on content and consumption of sugar in school meal for the nationwide project. For this purpose, we surveyed the sugar content of 842 school meal menus and their intake level for 154 days in 8 schools in Daejeon and Chungcheong Province. Sugar contents, the sum of the quantity of 5 sugars commonly detected in food, were analysed with HPLC-RID (Refractive Index Detector). Sugar intakes were calculated by multiplying the intake of each menu to the sugar content of that menu. The sugar content was highest in the desserts, which include fruit juices, dairy products and fruits. Sugar content of side dish was high in sauces and braised foods. Sugar intake from one dish is high in beverage and dairy product, and one dish meals contribute greatly to sugar intake because of their large amount of meal intake. The average lunch meal intakes of second grade and fifth grade elementary school students were 244 g/meal and 304 g/meal, respectively. The meal intake of middle school student was 401 g/meal. The average sugar intake from one day school lunch was 4.22 g (4.03 g on elementary and 5.31 g on middle school student), which is less than 10% of daily sugar reference value for Koreans. The result of this study provides exact data of sugar intake pattern based on the content of sugar which is matched directly to the meals consumed by the students.

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

Fermentable Sugar Contents of Commercial Medical Foods and Carbohydrate Ingredients (상업용 메디컬푸드 및 탄수화물 급원의 발효성 당류 함량에 관한 연구)

  • Shin, Hee-Chang;Kang, Nam-Hee;Lee, Jang-Woon;Lee, Yoon-Bok;Lee, Kyun-Hee;Oh, Seung-Hyun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.8
    • /
    • pp.1200-1205
    • /
    • 2015
  • Medical foods are enteral nutrition for patients, but they cause maladaptation symptoms like diarrhea. Although the cause of diarrhea remains unknown, some studies have indicated that the cause of diarrhea is fermentable oligosaccharides, disaccharides, monosaccharides, and polyols (FODMAP). This is a consideration for medical foods since they are easily fermented by intestinal bacterial. In this study, we estimated the FODMAP contents of commercial medical foods and carbohydrate ingredients. We measured the concentrations of FODMAP in 13 types of different medical foods and five types of carbohydrate ingredients by using high performance liquid chromatography with an evaporative light scattering detector (HPLC-ELSD). The limits of detection of FODMAP were fructose, 0.002; lactose, 0.010; raffinose, 0.003; stachyose, 0.032; 1-kestose, 0.005; nystose, 0.012; and 1-fructofuranosylnystose, 0.003 mg/kg. Limits of quantitation of FODMAP were fructose, 0.008; lactose, 0.033; raffinose, 0.009; stachyose, 0.107; 1-kestose, 0.015; nystose, 0.042; and 1-fructofuranosylnystose, 0.011 mg/kg, respectively. Concentration of FODMAP ranged from 0.428~2.968 g/200 mL. Concentrations of carbohydrate ingredients in FODMAP were chicory fiber, 278.423; soy fiber, 27.467; indigestible maltodextrin, 52.384; maltodextrin (DE10~15), 32.973; and maltodextrin (DE15~20), 50.043 g/kg. Contents of carbohydrates were 19.0~41.0 g/200 mL in commercial medical foods. We expected a correlation between contents of carbohydrates and FODMAP, as carbohydrates included FODMAP. However, we detected a low correlation (r=0.55). Since most commercial medical foods have a similar carbohydrate ingredients and nutritional values, the difference between products was determined by FODMAP contents of carbohydrate ingredients. In this study, we analyzed FODMAP contents of commercial medical foods and carbohydrate ingredients. These results are expected to be utilized as basic data for product development and minimizing maladaptation of medical foods.

Distributions of 137Cs and 90Sr in the Soil of Uljin, South Korea (울진토양에서의 137Cs 및 90Sr 분포)

  • Song, JiYeon;Kim, Wan;Maeng, Seongjin;Lee, Sang Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.49-55
    • /
    • 2016
  • Background: For the purpose of baseline data collection and enhancement of environmental monitoring the distribution studies of $^{137}Cs$ and $^{90}Sr$ in the soil of Uljin province was performed and the relation between surface soil activities and soil properties (pH, TOC and median of the surface soil) was analyzed. Materials and Methods: For 14 spots within 10 km from the NPP surface soil samples were collected and soils for depth profile were sampled for 3 spots in April 2011. Using ${\gamma}$-ray spectrometry with HPGe detector, the concentrations of $^{137}Cs$ were determined and the concentrations of $^{90}Sr$ were measured by counting ${\beta}$-activity of $^{90}Y$ (in equilibrium with $^{90}Sr$) in a gas flow proportional counter. Results and Discussion: The concentration ranges of $^{137}Cs$ and $^{90}Sr$ were $<0.479-39.6Bq{\cdot}(kg-dry)^{-1}$ (avg. $7.51Bq{\cdot}(kg-dry)^{-1}$) and $0.209-1.85Bq{\cdot}(kg-dry)^{-1}$ (avg. $0.74Bq{\cdot}(kg-dry)^{-1}$) which were similar to the reported values from other regions in Korea. The activity ratio of $^{137}Cs$ to $^{90}Sr$ in surface soils was around 9.67, which is much bigger than the initial value of 1.75 for worldwide fallouts because of faster downward movement of $^{90}Sr$ after fallout than that of $^{137}Cs$. For depth profile studies soils were collected down to 40 cm depth for the locations of Deokgu, Hujeong and Maehwa. The $^{137}Cs$ concentration distribution of the first two showed maximum values at top soils and decreased rapidly in exponential manner, while $^{90}Sr$ showed two local maximum values for soils near top and about 30 cm depth. Through linear fittings between the $^{137}Cs$ and $^{90}Sr$ concentrations of surface soil and pH, TOC and median of the surface soil, the only probable relationship obtained was between $^{137}Cs$ and TOC (determination coefficient $R^2=0.6$). Conclusion: The concentration ranges of $^{137}Cs$ and $^{90}Sr$ in Uljin were similar to the reported values from other regions in Korea. The only probable relationship obtained between activities and soil properties was between $^{137}Cs$ and TOC.

Monitoring Total Mercury and Methylmercury in Commonly Consumed Aquatic Foods (다소비 수산식품 중 총수은 및 메틸수은 모니터링)

  • Joo, Hyun-Jin;Noh, Mi-Jung;Yoo, Ji-Heon;Jang, Young-Mi;Park, Jong-Seok;Kang, Myoung-Hee;Kim, Mee-Hye
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.3
    • /
    • pp.269-276
    • /
    • 2010
  • Total mercury and methylmercury concentrations were determined in 15 commonly consumed aquatic food species using total mercury analyzer and gas chromatography with electron capture detector. The mean total mercury and methylmercury concentrations (mg/kg) were 0.088 and 0.034 in mackerel, 0.061 and 0.016 in hair tail, 0.030 and 0.005 in yellow croaker, 0.032 and 0.008 in Alaska pollock, 0.059 and 0.023 in eastern catfish, 0.110 and 0.045 in snakehead, 0.030 and 0.011 in Japanese common squid, 0.026 and 0.009 in common octopus, 0.035 and 0.008 in swimming crab, 0.009 and not detected (ND) in oyster, 0.011 and ND in shortneck clam, 0.008 and ND in mussel, 0.018 and ND in sea mustard, 0.007 and ND in nori, and 0.019 and ND in sea tangle, respectively. The total weekly dietary intakes of total mercury and methylmercury were estimated, respectively, using food consumption data from diet surveys and the concentrations of total mercury and methylmercury from this study. They were $0.178\;{\mu}g/kg$ body weight (b.w.)/week (3.57% of provisional tolerable weekly intake (PTWI)) and $0.052\;{\mu}g/kg$ b.w./week (3.34% of PTWI) respectively, and all were within their respective PTWI set by the Joint FAO/WHO Expert Committee on Food Additives (JECFA). Therefore, considering that the main contributor to mercury intake in the diet is aquatic foods and that the 15 aquatic food species examined in this study are highly consumed, it is concluded that the mercury levels in the foods measured in this study do not present a concern for consumer health.

Dosimetric Influence of Implanted Gold Markers in Proton Therapy for Prostate Cancer (전립선암에 대한 양성자치료에서 금마커에 의한 방사선 선량분포의 영향)

  • Kwak, Jung-Won;Shin, Jung-Wook;Kim, Jin-Sung;Park, Sung-Yong;Shin, Dong-Ho;Yoon, Myong-Geun;Park, So-Ah;Kim, Dong-Wook;Lim, Young-Gyeung;Lee, Se-Byeong
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.291-297
    • /
    • 2010
  • This study examined the dosimetric influence of implanted gold markers in proton therapy and the effects of their positions in the spread-out Bragg peak (SOBP) proton beam. The implanted cylindrical gold markers were 3 mm long and 1.2 mm in diameter. The dosimetric influence of the gold markers was determined with markers at various locations in a proton-beam field. Spatial dose distributions were measured using a three-dimensional moving water phantom and a stereotactic diode detector with an effective diameter of 0.5 mm. Also, a film dosimetry was performed using Gafchromic External Beam Treatment (EBT) film. The GEANT4 simulation toolkit was used for Monte-Carlo simulations to confirm the measurements and to construct the dose-volume histogram with implanting markers. Motion data were obtained from the portal images of 10 patients to investigate the effect of organ motions on the dosimetric influence of markers in the presence of a rectal balloon. The underdosed volume due to a single gold marker, in which the dose was less than 95% of a prescribed amount, was 0.15 cc. The underdosed volume due to the presence of a gold marker is much smaller than the target volume. However, the underdosed volume is inside the gross tumor volume and is not smeared out due to translational prostate motions. The positions of gold markers and the conditions of the proton-beam field give different impacts on the dose distribution of a target with implanted gold markers, and should be considered in all clinical proton-based therapies.

The Influence of Landscape Pavements on the WBGT of Outdoor Spaces without Ventilation or Shade at Summer Midday (조경포장이 옥외공간의 온열쾌적성지수(WBGT)에 미치는 영향 - 통풍과 차광이 배제된 하절기 주간의 조건에서 -)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.2
    • /
    • pp.1-8
    • /
    • 2010
  • The purpose of the study was to evaluate the influence of landscaping pavements on WBGT(Wet-Bulb Globe Temperature) of outdoor spaces that lack ventilation and shade at summer midday. The relative humidity(RH), dry-bulb temperature(DT) and globe temperature(GT) were recorded every minute from June to October 2009 at a height of 1.2m above ten experimental beds with different pavements, by a measuring system consisting of an electric humidity sensor(GHM-15), resistance temperature detector(RTD, Pt-100), standard black globe(${\phi} 150mm$) and data acquisition systems(National Instrument's Labview and Compact FieldPoint). Additionally, the surface dry-bulb temperatures also were recorded and compared. The area of each experimental bed was 1.5m(W)${\times}$2.0m(L) and ten different kinds of pavement were used including grass, grass+cubic stone, grass+porous brick, brick, stone panels, cubic stone, interlocking blocks, clay brick, naked soil, gravel and concrete. To prevent interference from ventilation, a 1.5m height cubic steel frame was established around each bed and each vertical side of the frame was covered with transparent polyethylene film. Based on the records of the hottest period from noon to 3 PM on 26 days with a peak dry-bulb temperature over $30^{\circ}C$ at natural condition, the wet-bulb temperature(WT) and WBGT were calculated and compared. The major findings were as follows: 1. The average surface DT was $40.1^{\circ}C$, which is $9^{\circ}C$ higher than that of the natural condition. The surface DT of the pavements with grass were higher than those of concrete and interlocking block. The peak DT of the surface almost every pavement rose to above $50^{\circ}C$ during the hottest time. 2. The averages of DT, WT and GT were $40.1^{\circ}C$, $27.5^{\circ}C$ and $49.1^{\circ}C$, and the peak values rose to $48.1^{\circ}C$, $45.8^{\circ}C$ and $59.5^{\circ}C$, respectively. In spite of slight differences that resulted according to pavements, no coherent differentiating factor could be found. 3. The average WBGT of grass was the highest at $34.3^{\circ}C$ while the others were similar in the range of around $33{\pm}1^{\circ}C$. Meanwhile, the peak WBGT was highest with stone panel at $47.9^{\circ}C$. Though there were some differences according to pavements, and while grass seemed to be worst in terms of WBGT, it seems difficult to say ablolutely that grass was the worst because the measurement was conducted without ventilation and shade during summer daytime hours only, which had temperatures that rose to a dangerous degree(above $45^{\circ}C$ WBGT), withering the grass during the hottest period. The average WBGT resulted also showed that the thermal environment of the pavement without ventilation and shade were at an intolerable level for humans regardless of the pavement type. In summary, the results of this study show that ventilation and shade are more important factor than pavement type in terms of outdoor thermal comfort in summer daylight hours.

Development of Aceclofenac Soft Capsule (Clanza S Soft Capsule) (아세클로페낙 연질캡슐(클란자 에스 연질캡슐)의 개발)

  • Yong, Chul-Soon;Lee, Kyung-Hee;Choi, Jin-Suck;Park, Byung-Joo;Jung, Se-Hyun;Kim, Yong-Il;Park, Sang-Man;Bae, Myung-Soo;Kim, Gui-Ja;Gill, Young-Sig;Yu, Chang-Hun;Kang, Sung-Lyoung;Yoo, Bong-Kyu;Rhee, Jong-Dal;Choi, Han-Gon
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.1
    • /
    • pp.49-55
    • /
    • 2004
  • To develop a aceclofenac soft capsule, four preparations with various solubilizers were prepared and their dissolution test was carried out. Among four preparations tested, a preparation with ethanolamine was selected as a formula of aceclofenac soft capsule (Clanza $S^{TM}$), since it showed the fastεst dissolution rate. Bioequivalence of aceclofenac tablet, $Airtal^{TM}$ (Dae-Woong Pharmaceutical Co., Ltd.) and aceclofenac soft capsule, Clanza $S^{TM}$ (Korea United Pharmaceutical Co., Ltd.) was evaluated according to the guideline of KA Fourteen normal male volunteers (age 20 - 25 years old) were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After oral administration of one tablet or capsule containing 100 mg of aceclofenac, blood was taken at predetermined time intervals and the concentration of aceclofenac in plasma was determined with an HPLC method under UV detector The pharmacokinetic parameters ($C_{max}$ and $AUC_t$) were calculated and ANOVA was utilized for the statistical analysis of parameters using logarithmetically transformed $AUC_t$, $C_{max}$ and $T_{max}$. The results showed that the differences in $AUC_t$, $C_{max}$ and $T_{max}$ between Aral tablet and Clanza soft capsule were 2.89%, 0.18% and 43.0%, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log(0.8) to log(15) (e.g. log(0.81) -log(1.23) ad log(0.89) -log(1.4)) fo $AUC_t$ and $C_{max}$, respectively. Thus, the criteria of the KFDA guidelines for the equivalence was satisfied, indicating that Clanza $S^{TM}$ soft capsule is bioequivalent to$Airtal^{TM}$ tablet.