• 제목/요약/키워드: detection voltage

검색결과 918건 처리시간 0.035초

비접촉 전압위상 검출 기술을 이용한 무정전 절연저항 측정 방법에 관한 연구 (A Study on Measurement Technique of Insulation Resistance for Non-interrupting Inspection Using Non-contact Voltage Phase Detection Technology)

  • 이기연;문현욱;김동우;임용배;최동환;김용혁
    • 전기학회논문지
    • /
    • 제67권8호
    • /
    • pp.1106-1112
    • /
    • 2018
  • In this paper, measurement techniques are presented to test the performance of insulation without interruption if it is difficult to measure insulation resistance. Especially, non-contact voltage phase detection techniques have been developed that can be applied in environments where it is difficult to find voltage measurement locations such as component receptors. The performance verification of the non-interrupting insulation resistance measuring devices has been tested against existing products using standard calibration equipment and test jigs. The validation confirmed performance within 2 % for direct contact type and within 10 % for non-contact type. In addition, the procedure to make continuous insulation test using the equipment was proposed.

전력선 계통의 순시 전압 강하 제어기 설계 (Instantaneous Voltage Sag Corrector Controller Design of Power Line System)

  • 이상훈;홍현문
    • 조명전기설비학회논문지
    • /
    • 제20권3호
    • /
    • pp.6-11
    • /
    • 2006
  • 본 논문은 전력품질 향상을 목적으로 VSC의 새로운 제어 기법의 디자인에 대하여 기술하였다. 전압강하의 빠른 검출 기술은 동기 회전 d q-기준축에서 순시값의 검출을 통해서 구현되었다. 1차 디지털 필터는 노이즈에 대하여 둔감한 특성을 막을 수 있는 검출 알고리즘을 부가하였다. 필터의 전체 검출과 컷오프 주파수 사이에서 관계에 대하여 기술하였다. 에너지 저장 요소로서 사용되는 캐패시터 뱅크의 사이즈는 회로 해석으로서 입 출력 에너지의 관점에서 디자인 되었다. 마지막으로, 제안된 기법의 유효성은 모의실험을 통하여 증명되었다.

Open and Short Circuit Switches Fault Detection of Voltage Source Inverter Using Spectrogram

  • Ahmad, N.S.;Abdullah, A.R.;Bahari, N.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.190-199
    • /
    • 2014
  • In the last years, fault problem in power electronics has been more and more investigated both from theoretical and practical point of view. The fault problem can cause equipment failure, data and economical losses. And the analyze system require to ensure fault problem and also rectify failures. The current errors on these faults are applied for identified type of faults. This paper presents technique to detection and identification faults in three-phase voltage source inverter (VSI) by using time-frequency distribution (TFD). TFD capable represent time frequency representation (TFR) in temporal and spectral information. Based on TFR, signal parameters are calculated such as instantaneous average current, instantaneous root mean square current, instantaneous fundamental root mean square current and, instantaneous total current waveform distortion. From on results, the detection of VSI faults could be determined based on characteristic of parameter estimation. And also concluded that the fault detection is capable of identifying the type of inverter fault and can reduce cost maintenance.

Hybrid 검출방식을 적용한 삼상 선로 응동형 DVR(Dynamic Voltage Restorer) (Development of Three-Phase Line-Interactive Dynamic Voltage Restorer with Hybrid Detection Method)

  • 정종규;한병문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.901_902
    • /
    • 2009
  • This paper describes the development of a three-phase Line-Interactive DVR(Dynamic Voltage Restorer), which is applied to Hybrid detection method and super-capacitor. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental will be work with 3kVA prototype. The developed system can compensates the input voltage sag and interruption within 2ms, in which the maximum allowable sensitive load, such as computer, communication equipment, automation equipment, and medical equipment. The developed system has a simple structure to be easily implemented with commercially available components and to be highly reliable in operation.

  • PDF

필터뱅크기법에 기반한 전력신호 플리커 검출 (Power Signal Flicker Detection Based on Filter Bank Technique)

  • 최훈;배현덕
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.179-193
    • /
    • 2016
  • In power quality monitoring, voltage fluctuation is one of the power quality problems, which cause light flickers. To determine the flicker severity, the flicker meter concept was developed in an IEC 61000-4-15 standard. Generally, voltage fluctuations are described as an amplitude modulation(AM). The flicker meter of IEC 61000-4-15 as an international standard for flicker measurement recommends square demodulation method to detect flicker signals from voltage fluctuation signals. This paper suggests a new effective method using filter bank to detect and estimate flicker signals, which do not need square demodulation. For the accurate detection of flicker signals, the filter bank is designed with a full consideration of the spectrum characteristics of voltage fluctuation signals described as AM. The frequency and magnitude of the detected flicker signals are estimated using recursive method. Computer simulations were performed on synthesized signals to prove validity of the proposed method.

계통연계형 태양광발전시스템을 위한 단독운전 검출에 관한 연구 (A Study on the Islanding Detection for Grid Connected Photovoltaic System)

  • 이기제;김민;이진섭;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.555-558
    • /
    • 2002
  • The general ways of the anti-islanding can be classified into the active method and passive method. The passive method which use only the voltage information when power failure occurs has much possibility of the wrong detection. And the active method detects the change of the voltage frequency as instantaneously changing the frequency of the inverter output current. Therefore, in this paper, the method to inject arbitrary order harmonics into controlled current is proposed. In this method islanding can be detected by measuring the amount of load voltage of injected harmonics order. And as a current control method predictive control method is used, which make actual current accurately to track reference current by Instantaneously computing converter output voltage and has fast response in transient state. This parer proposed method was verified by simulation.

  • PDF

위상고정회로를 사용한 AM신호 검파방식의 해석 (An Analysis of a Phase Locked AM signal Detection)

  • 문상재
    • 대한전자공학회논문지
    • /
    • 제13권5호
    • /
    • pp.24-29
    • /
    • 1976
  • Phase locked AM신호 검파방식에서는 위상고정회로를 사용하여 입력신호로부터 반송신호를 분리 재생시킨다. 입력잡음은 백색 Gaussian잡음이고, 전려제어발진기의 자유발진주파수와 입력반송신호주파수가 같다는 가정하에 위상고정회로의 동작특성을 해석하고, 본 검파방식의 신호대 잡음비를 정량적으로 고찰하였다. Phase locked AM신호 검파방식은 종래의 검파방식에 비해서 잡음의 영향을 적게 받게됨을 본 해석에서 알 수 있다. In the phase locked AM signal detection, phase locked loop is used to extract a synchronous carrier from an input AM signal. Under the assumption that input noise is white Gaussian and free-running frequency of voltage controlled oscillator is the same that of an input carrier, operational behaviours of phase locked loop is analyzed and signal to noise ratio of the detection is derived quentitatively. The results show that the phase locked AM signal detection method offers a higher degree of noise mmunity than conventional AM signal detections.

  • PDF

Anomaly detection of isolating switch based on single shot multibox detector and improved frame differencing

  • Duan, Yuanfeng;Zhu, Qi;Zhang, Hongmei;Wei, Wei;Yun, Chung Bang
    • Smart Structures and Systems
    • /
    • 제28권6호
    • /
    • pp.811-825
    • /
    • 2021
  • High-voltage isolating switches play a paramount role in ensuring the safety of power supply systems. However, their exposure to outdoor environmental conditions may cause serious physical defects, which may result in great risk to power supply systems and society. Image processing-based methods have been used for anomaly detection. However, their accuracy is affected by numerous uncertainties due to manually extracted features, which makes the anomaly detection of isolating switches still challenging. In this paper, a vision-based anomaly detection method for isolating switches, which uses the rotational angle of the switch system for more accurate and direct anomaly detection with the help of deep learning (DL) and image processing methods (Single Shot Multibox Detector (SSD), improved frame differencing method, and Hough transform), is proposed. The SSD is a deep learning method for object classification and localization. In addition, an improved frame differencing method is introduced for better feature extraction and a hough transform method is adopted for rotational angle calculation. A number of experiments are conducted for anomaly detection of single and multiple switches using video frames. The results of the experiments demonstrate that the SSD outperforms the You-Only-Look-Once network. The effectiveness and robustness of the proposed method have been proven under various conditions, such as different illumination and camera locations using 96 videos from the experiments.

센서리스 매입형 영구자석 브러시리스 직류전동기 구동장치에서 단순화된 회전자 위치검출 오차 분석 방법 (A Simplified Analysis Approach on the Rotor Position Detection Error in Sensorless Interior Permanent Magnet Brushless DC Motor Drives)

  • 이광운;박태식
    • 전력전자학회논문지
    • /
    • 제21권5호
    • /
    • pp.449-452
    • /
    • 2016
  • This paper presents a simplified analysis on the rotor position detection error in sensorless interior permanent magnet brushless DC motor (BLDCM) drives, wherein terminal voltage sensing based on the back-electromotive force (back-EMF) zero-crossing point detecting circuitry is employed. The effect of a rotor saliency on the back-EMF's zero-crossing point detection is analyzed using the extended EMF-based voltage equation of the interior permanent BLDCM in a stationary reference frame, and thus the overall analysis is considerably simplified compared to the conventional one. Simulation results are provided to verify the effectiveness of the proposed method.

전류 테스팅 고장모델을 위한 객체기반의 고장 검출 (Object Oriented Fault Detection for Fault Models of Current Testing)

  • 배성환;한종길
    • 한국전자통신학회논문지
    • /
    • 제5권4호
    • /
    • pp.443-449
    • /
    • 2010
  • 전류 테스팅은 기존의 전압 테스트 방식에 비해서 높은 고장 검출과 진단 능력을 가진 효과적인 테스트 방식이다. 그러나 상대적으로 느린 전류 테스팅을 위해서 항상 같은 값을 가지는 노드를 찾아내어 제거하는 효율적인 검출 기법이 필요하다. 본 논문에서는 전류 테스팅을 위한 다양한 고장모델에 적용 가능한 객체기반의 고장 검출 기법을 제안한다. ISCAS 벤치마크 회로의 실험결과을 통해서 제안된 방식이 고려되는 고장의 수를 효과적으로 감소시킬 수 있고 다양한 전류 테스팅 고장모델에 적용 가능함을 확인하였다.