• Title/Summary/Keyword: detection technique

Search Result 4,102, Processing Time 0.031 seconds

Evaluation of Saltwater Intrusion to Coastal Aquifer by Using Probability Statistics (확률통계기법을 이용한 해안지역 대수층의 염수침입 평가)

  • Cheong, Jae-Yeol;Hamm, Se-Yeong;Kim, Kwang-Koo;Lee, Chung-Mo;Jeon, Hang-Tak;Ok, Soon-Il
    • The Journal of Engineering Geology
    • /
    • v.26 no.3
    • /
    • pp.371-382
    • /
    • 2016
  • Saltwater intrusion in coastal regions can be detected by using numerous geochemical constituents in groundwater. However, insufficient numbers of groundwater data can often make us difficult to interpret saltwater intrusion. Probability statistics technique enables statistical prediction using a limited numbers of water quality data for a wider range and can make to effectively evaluate saltwater intrusion through a characterized distribution of probability. This study evaluated saltwater intrusion by applying probability statistics to the chemical constituents in groundwater, coastal discharge, and stream water in the coastal areas of Busan City. By the result of the study, it is proven that Na+, Mg2+, K+, SO42−, and Cl, abundantly contained in seawater, are valuable indicators for evaluating saltwater intrusion. On the other hand, it is judged that Si4+, Fe2+, NO3, and PO43−, showing similar probability distribution in groundwater, coastal discharge, and stream water, are not appropriate indicators for the detection of saltwater intrusion.

Isolation and identification of Cryptosporidium from various animals in Korea I. Prevalence of Cyuptosporidium in various animals (한국산 동물로부터 크립토스포리디움의 분리 및 동정 I . 각종 동물의 크립토스포리더움 감염상황)

  • Lee, Jae-Gu;Seo, Yeong-Seok;Park, Bae-Geun
    • Parasites, Hosts and Diseases
    • /
    • v.29 no.2
    • /
    • pp.139-148
    • /
    • 1991
  • Cryptosporidium, a coccidian protozoa, commonly causes a self-limiting diarrheal illness in humans and animals. Fecal samples from various animals in Chonbuk district were observed using Sheather's aoatation technique, Kinyoun's modified acid-fast staining, and osmic acid pre-fixed Giemsa staining. The oocysts were detected in 74 cages(29.6%) out of 250 cages of mature mice, 26 (13.3%) out of 195 mature house rats, 75 (15.0%) out of 4-week-old 500 fowls, 98(19.9%) out of 6 to 8-month-old 500 pigs, and 111(22,2%) out of 2 to 5-year-old 500 dairy cattle, respectively. The degree of prevalence was slight in general, but actual prevalence was higher than infection rate because the detection rates were higher in repeated-preparation examinations in comparison to the first examination. Meanwhile, large and small types of oocysts were detected from mice, house rats, pigs, and cattle, and midium type from fowls.

  • PDF

Automatic On-Chip Glitch-Free Backup Clock Changing Method for MCU Clock Failure Protection in Unsafe I/O Pin Noisy Environment (안전하지 않은 I/O핀 노이즈 환경에서 MCU 클럭 보호를 위한 자동 온칩 글리치 프리 백업 클럭 변환 기법)

  • An, Joonghyun;Youn, Jiae;Cho, Jeonghun;Park, Daejin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.12
    • /
    • pp.99-108
    • /
    • 2015
  • The embedded microcontroller which is operated by the logic gates synchronized on the clock pulse, is gradually used as main controller of mission-critical systems. Severe electrical situations such as high voltage/frequency surge may cause malfunctioning of the clock source. The tolerant system operation is required against the various external electric noise and means the robust design technique is becoming more important issue in system clock failure problems. In this paper, we propose on-chip backup clock change architecture for the automatic clock failure detection. For the this, we adopt the edge detector, noise canceller logic and glitch-free clock changer circuit. The implemented edge detector unit detects the abnormal low-frequency of the clock source and the delay chain circuit of the clock pulse by the noise canceller can cancel out the glitch clock. The externally invalid clock source by detecting the emergency status will be switched to back-up clock source by glitch-free clock changer circuit. The proposed circuits are evaluated by Verilog simulation and the fabricated IC is validated by using test equipment electrical field radiation noise

Determination of 4 Parabens in Human Urine by Online SPE and LC-MS/MS Techniques (온라인 고체상추출과 LC-MS/MS 기술을 이용한 소변 중 파라벤류 분석)

  • Kim, Jung Hoan;Kho, Young Lim;Kim, Pan Gyi;Jeong, Jee Yeon;Lee, Eun Hee;Lee, Seung-Youl;Nam, Hye-Seon;Rhee, Gyu-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.6
    • /
    • pp.561-567
    • /
    • 2012
  • Objectives: Parabens are widely used as antimicrobial agents in pharmaceuticals and cosmetics as well as by the food industry. Parabens have been reported to show weak estrogenic activity and be related to health effects such as allergic reactions and skin and breast cancer. We evaluated an online solid phase extraction (SPE) method coupled with LC-MS/MS technique using free and conjugated parent parabens in human urine for assessing human exposure to parabens. Methods: We employed LC/MS/MS through online solid phase extraction and column-switching techniques and analyzed free and conjugated parabens as biomarkers of human exposure. Four major parabens, methyl-paraben (MP), ethyl-paraben (EP), propyl-paraben (PP) and butyl-paraben (BP), were analyzed. Method validation was performed by sensitivity, accuracy, precision and comparison of the results of online SPE with offline SPE. Results: The limits of detection (LOD) were in the range of 0.2-2 ng/mL, and actual limits of quantification (LOQ) were in the range of 0.7-6 ng/mL urine, depending upon the compound. Accuracy was in the range of 98.3-106.4%, and precision was in the range of 1.3-8.7% (CV) depending upon the compound. We found a good correlation between the results of analysis by online SPE method and that by off-line SPE method. Conclusions: The online SPE method showed proper LOD and validated accuracy, precision and good correlation with the offline method for analyzing parabens in urine.

Voice Packet Processing Scheme for Voice Quality and Bandwidth Efficiency in VoIP (VoIP의 음성품질/대역효율 개선을 위한 음성패킷 처리)

  • Kim, Jae-Won;Sohn, Dong-Chul
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.7
    • /
    • pp.896-904
    • /
    • 2004
  • In this paper, We present an efficient variable rate speech coder for spectral efficiency and packet processing technique for packet loss compensation of a voice codec with 10msec frame in VoIP service. Through disconnecting the users from the spectral resource during silence interval of about 60% period, a variable rate voice coder based on a voice activity detection(VAD) can increase spectral gain by two times. The performance of the method was analyzed by variation of detected voice activity factor and degraded speech frame ratio under various background noise level, and compared those of G.729B of ITU-T 8kbps standard speech codec. A method to compensate lost packets utilized addition of recovery data to a main stream and error concealment scheme for speech quality enhancement, the performance is verified by reconstructed speech quality. The proposed scheme can achieve spectral gain by two times or enhance speech quality by 3dB through reserved bandwidth of VAD. Therefore, the proposed method can enhance a spectral efficiency or speech quality of VoIP.

  • PDF

Measurement of Total Plasma Homocysteine in Patients with Chronic Renal Failure Using HPLC/FLD (만성신부전증환자에서 HPLC/FLD를 이용한 혈장 Homocysteine의 측정)

  • Kyung-Ok Lee;Bo-Kyung Kang;Hyung-Jin Roh;Kwang-Suk Ryoo;Jeong-Yeon Yoo;Man-Jeong Paik;Kang-Hyeob Lee
    • Biomedical Science Letters
    • /
    • v.3 no.1
    • /
    • pp.29-35
    • /
    • 1997
  • Cardiovascular disease has been the leading cause of death among patients with chronic renal failure. Many reports have been described that homocysteine is one of the independent risk factor to the occulsive vascular disease. In this study, HPLC/FLD (high performance liquid chromatography-fluorescence detector) technique was used to measure homocysteine level in patients with chronic renal failure and normal control group. The detection limit and recovery of total plasma homocysteine using HPLC/FLD were 98.6$\pm$5.8% and 0.2 nmol/ml, respectively. The linearity of this method was established in concentration range of 2~50 nmol/ml (correlation coefficient=0.9997). The concentrations of total plasma homocysteine were 6.81$\pm$1.54 nmol/ml and 27.28$\pm$14.94 nmol/ml in normal control (n=20) and patient group (n=90), respectively (p<0.05). In this study, the HPLC/FLD method showed high sensitivity and reproducibility for a routine clinical laboratory testing. Moreover determination of homocysteine level in plasma might be useful for a biochemical marker for predicting the cardiovascular diseases and for monitoring of therapeutic effect of lowering homocysteine in patients with chronic renal failure.

  • PDF

Rapid Detection of Lactobacillus Genus Inhabiting in Vagina of 20's Healthy Women Using Multiplex PCR (Multiplex PCR 분석을 통한 건강한 20대 여성의 질 내에 서식하는 Lactobacillus 속 유산균의 신속한 검출)

  • Oh, Cho-Rong;Cho, Hong-Bum
    • Korean Journal of Microbiology
    • /
    • v.48 no.4
    • /
    • pp.309-313
    • /
    • 2012
  • The purpose of this study is to simultaneously detect and identify specific genus of Lactobacillus distributed in vagina of healthy women in their twenties by using multiplex primer. Vaginal fluid samples were taken from 166 women who were healthy and did not have vaginosis symptoms caused by bacterial infection. Six species of lactic acid bacteria belong to Lactobacillus genus that are known to inhabit in healthy vagina were selected to make a species-specific multiplex primer. Multiplex primer I was specified to selectively detect L. iners, L. crispatus, L. gasseri and multiplex primer II was specified to selectively detect L. acidophilus, L. jensenii, L. fermentum. L. crispatus (77%) was most frequently detected, and L. acidophilus (57%) and L. jensenii (57%) were relatively higher than others. Although the proportion of L. iners (59%) was a little higher than those of L. acidophilus and L. jensenii, this should be further validated in healthy women's vagina to be sure since they often appear in women having bacterial vaginosis and/or during the antibiotic therapy. Conclusively, the multiplex PCR technique using the species-specific primer could a useful tool to predict variation of vaginal health condition and process of recovery from vaginal disease.

Analysis of Music and Photo for User Creative Movie (동영상 콘텐츠 생성을 위한 음악과 사진 분석)

  • Chung, Myoung-Bum;Ko, Il-Ju
    • The KIPS Transactions:PartD
    • /
    • v.14D no.4 s.114
    • /
    • pp.381-388
    • /
    • 2007
  • Consumers changed to the subject to produce a digital contents as data transmission technique is advanced and a digital machine is diffused variously. Users are interested greatly in a user creative movie (UCM) production among various online contents. The UCM production method which uses the music and picture is the method that users make the UCM more easily. However, the UCM production service has the problem that any association does not exist in the music and picture and that the picture changes according to fixed time interval without the relation at a music rhythm. To solve this problem, we propose the UCM production method which uses a music analysis and picture analysis in the paper. A music analysis finds a picture change time according to the rhythm and a picture analysis finds the association of the picture. A music analysis finds strong parts of the sound which uses Root-Mean-Square (RMS). And a picture analysis classifies the picture as a scenery picture and people picture which uses structure simplicity of the picture(SSP) and face region detection. A picture analysis got correct result of 86.4% in the experiment and we can finds the association at each picture and arranges the sequence which the picture appears. Therefore, if we use a music and picture analysis at the UCM production, users may make natural and efficient movie.

Development of CCTV Cooperation Tracking System for Real-Time Crime Monitoring (실시간 범죄 모니터링을 위한 CCTV 협업 추적시스템 개발 연구)

  • Choi, Woo-Chul;Na, Joon-Yeop
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.546-554
    • /
    • 2019
  • Typically, closed-circuit television (CCTV) monitoring is mainly used for post-processes (i.e. to provide evidence after an incident has occurred), but by using a streaming video feed, machine-based learning, and advanced image recognition techniques, current technology can be extended to respond to crimes or reports of missing persons in real time. The multi-CCTV cooperation technique developed in this study is a program model that delivers similarity information about a suspect (or moving object) extracted via CCTV at one location and sent to a monitoring agent to track the selected suspect or object when he, she, or it moves out of range to another CCTV camera. To improve the operating efficiency of local government CCTV control centers, we describe here the partial automation of a CCTV control system that currently relies upon monitoring by human agents. We envisage an integrated crime prevention service, which incorporates the cooperative CCTV network suggested in this study and that can easily be experienced by citizens in ways such as determining a precise individual location in real time and providing a crime prevention service linked to smartphones and/or crime prevention/safety information.

Determination of Hg (II) Ion at a Chemically Modified Carbon Paste Electrode Containing L-Sparteine (L-Sparteine 수식전극을 사용한 Hg (II) 이온의 정량)

  • Euh Duck Jeong;Mi-Sook Won;Yoon-Bo Shim
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.5
    • /
    • pp.545-552
    • /
    • 1991
  • A mercury ion-sensitive carbon-paste electrode (CPE) was constructed with l-sparteine. Mercury (II) ion was chemically deposited by the complexation with l-sparteine onto the CPE. The surface of CPEs was characterized by cyclic voltammetry and anodic stripping voltammetry in an acetate buffer solution, separately. Exposure of CPEs to acid solution could regenerate surface and reuse it for deposition. In 5 deposition/measurement/regeneration cycle, the response was reproducible and in licnear up to $2.0\;{\times}\;10^{-6}$ M with linear sweep voltammetry. In case of using the differential pulse technique, we have obtained the linear response up to $7.0 {\times}10^{-7}$ M with relative standard deviation of ${\pm}5.1$%. The detection limit was $5.0{\times}10^{-7}$ M for 20 minutes of the deposition. We have investigated the interference effect of various metal ions, which are expected to form the complex with ligand. Silver (I) ion of these has interfered with the analysis of Hg (II) ions. However, pretreatment of the silver (I) ion with potassium chloride led to no interference on the analysis of mercury ions in aqueous solution.

  • PDF