• Title/Summary/Keyword: detection technique

Search Result 4,102, Processing Time 0.044 seconds

Development and Implementation of an Over-Temperature Protection System for Power Semiconductor Devices (전력용 반도체 소자의 과열보호시스템 설계 및 구현)

  • Choi, Nak-Gwon;Lee, Sang-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.2
    • /
    • pp.163-168
    • /
    • 2010
  • This paper presents the practical implementation of an over-temperature protection system for power semiconductor devices. In the proposed system, temperature variation is provided with just using $R_{ds(on)}$ characteristics of power MOSFET, while extra device such as a temperature sensor or an over-temperature detection transistor is needed to monitor the temperature in the conventional method. The proposed protection technique is experimentally tested on IRF840 power MOSFET. The PIC microcontroller PIC16F877A is used for the implementation of the proposed protection algorithm. The built-in 10-bit A/D converter is utilized for detecting voltage variance between a drain and a source of IRF840. The induced temperature-resistance relationship based on the measured drain-source voltage, supplies a gate signal to the power MOSFET. If detected temperature's voltage exceeds any a protection temperature's voltage, the microcontroller removes the trigger signal from the power MOSFET. These test results showed satisfactory performances of the proposed protection system in term of accuracy within 1.5%.

Preprocessing Algorithm of Cell Image Based on Inter-Channel Correlation for Automated Cell Segmentation (자동 세포 분할을 위한 채널 간 상관성 기반 세포 영상의 전처리 알고리즘)

  • Song, In-Hwan;Han, Chan-Hee;Lee, Si-Woong
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.84-92
    • /
    • 2011
  • The automated segmentation technique of cell region in Bio Images helps biologists understand complex functions of cells. It is mightly important in that it can process the analysis of cells automatically which has been done manually before. The conventional methods for segmentation of cell and nuclei from multi-channel images consist of two steps. In the first step nuclei are extracted from DNA channel, and used as initial contour for the second step. In the second step cytoplasm are segmented from Actin channel by using Active Contour model based on intensity. However, conventional studies have some limitation that they let the cell segmentation performance fall by not considering inhomogeneous intensity problem in cell images. Therefore, the paper consider correlation between DNA and Actin channel, and then proposes the preprocessing algorithm by which the brightness of cell inside in Actin channel can be compensated homogeneously by using DNA channel information. Experiment result show that the proposed preprocessing method improves the cell segmentation performance compared to the conventional method.

Detection of Abnormal Behavior by Scene Analysis in Surveillance Video (감시 영상에서의 장면 분석을 통한 이상행위 검출)

  • Bae, Gun-Tae;Uh, Young-Jung;Kwak, Soo-Yeong;Byun, Hye-Ran
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.12C
    • /
    • pp.744-752
    • /
    • 2011
  • In intelligent surveillance system, various methods for detecting abnormal behavior were proposed recently. However, most researches are not robust enough to be utilized for actual reality which often has occlusions because of assumption the researches have that individual objects can be tracked. This paper presents a novel method to detect abnormal behavior by analysing major motion of the scene for complex environment in which object tracking cannot work. First, we generate Visual Word and Visual Document from motion information extracted from input video and process them through LDA(Latent Dirichlet Allocation) algorithm which is one of document analysis technique to obtain major motion information(location, magnitude, direction, distribution) of the scene. Using acquired information, we compare similarity between motion appeared in input video and analysed major motion in order to detect motions which does not match to major motions as abnormal behavior.

The Study on X-ray Detection Characteristics of Radiation Detective Sensor with Changing Composition Ratio of Iodine in a-Se (a-Se에 첨가된 Iodine의 조성비 변화에 따른 X선 검출특성 연구)

  • Cha, Byung-Youl;Kang, Sang-Sik;Lee, Gyu-Hong;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.399-402
    • /
    • 2002
  • This paper is researched that electric characteristic of Digital x-ray radiography technique with changing composition ratio of Iodine. Dopant material, Iodine is evaporated with amorphous selenium. Thorugh the old papers say, doponted Iodine will be down the created trap level because of Arsenic dopant material in amorphous selenium. Arsenic material of Composition ratio in amorphous selenium is fixed with 0.3% and test sample is deposited composition of 30, 100, 300, 500, 700ppm with thermal evaporate system. Experimental measurement is performed by dark current and x-ray sensitivity in amorphous selenium based radition detector sensor. Fabricated test sample thickness is $30{\mu}m$ and injected voltage is $3{\mu}m$$6{\mu}m$$9{\mu}m$ to both electrode. Experimental results showed that the net charge of composition rate of 30ppm is 398.88 pc/mR/$cm^2$ very high. And increase of the Iodine composition ratio is tendency to the decrease of net charge. Doping changing composition of Iodine in amorphous selenium detector offered to basical information of amorphous selenium material.

  • PDF

Fabrication and packaging techniques for the application of MEMS strain sensors to wireless crack monitoring in ageing civil infrastructures

  • Ferri, Matteo;Mancarella, Fulvio;Seshia, Ashwin;Ransley, James;Soga, Kenichi;Zalesky, Jan;Roncaglia, Alberto
    • Smart Structures and Systems
    • /
    • v.6 no.3
    • /
    • pp.225-238
    • /
    • 2010
  • We report on the development of a new technology for the fabrication of Micro-Electro-Mechanical-System (MEMS) strain sensors to realize a novel type of crackmeter for health monitoring of ageing civil infrastructures. The fabrication of micromachined silicon MEMS sensors based on a Silicon On Insulator (SOI) technology, designed according to a Double Ended Tuning Fork (DETF) geometry is presented, using a novel process which includes a gap narrowing procedure suitable to fabricate sensors with low motional resistance. In order to employ these sensors for crack monitoring, techniques suited for bonding the MEMS sensors on a steel surface ensuring good strain transfer from steel to silicon and a packaging technique for the bonded sensors are proposed, conceived for realizing a low-power crackmeter for ageing infrastructure monitoring. Moreover, the design of a possible crackmeter geometry suited for detection of crack contraction and expansion with a resolution of $10{\mu}m$ and very low power consumption requirements (potentially suitable for wireless operation) is presented. In these sensors, the small crackmeter range for the first field use is related to long-term observation on existing cracks in underground tunnel test sections.

Determination of Non-Steroidal Anti-Inflammatory Drugs in Human Urine Sample using HPLC/UV and Three Phase Hollow Fiber-Liquid Phase Microextraction (HF-LPME)

  • Cha, Yong Byoung;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3444-3450
    • /
    • 2013
  • Three phase hollow fiber-liquid phase microextraction (HF-LPME), which is faster, simpler and uses a more environmentally friendly sample-preparation technique, was developed for the analysis of Non-Steroidal Anti-Inflammatory Drugs (NSAIDs) in human urine. For the effective simultaneous extraction/concentration of NSAIDs by three phase HF-LPME, parameters (such as extraction organic solvent, pH of donor/acceptor phase, stirring speed, salting-out effect, sample temperature, and extraction time) which influence the extraction efficiency were optimized. NSAIDs were extracted and concentrated from 4 mL of aqueous solution at pH 3 (donor phase) into dihexyl ether immobilized in the wall pores of a porous hollow fiber, and then extracted into the acceptor phase at pH 13 located in the lumen of the hollow fiber. After the extraction, 5 ${\mu}L$ of the acceptor phase was directly injected into the HPLC/UV system. Simultaneous chromatographic separation of seven NSAIDs was achieved on an Eclipse XDB-C18 (4.6 mm i.d. ${\times}$ 150 mm length, 5 ${\mu}m$ particle size) column using isocratic elution with 0.1% formic acid and methanol (30:70) at a HPLC-UV/Vis system. Under optimized conditions (extraction solvent, dihexyl ether; $pH_{donor}$, 3; $pH_{acceptor}$, 13; stirring speed, 1500 rpm; NaCl salt, 10%; sample temperature, $60^{\circ}C$; and extraction time, 45 min), enrichment factors (EF) were between 59 and 260. The limit of detection (LOD) and limit of quantitation (LOQ) in the spiked urine matrix were in the concentration range of 5-15 ng/mL and 15-45 ng/mL, respectively. The relative recovery and precision obtained were between 58 and 136% and below 15.7% RSD, respectively. The calibration curve was linear within the range of 0.015-0.96 ng/mL with the square of the correlation coefficient being more than 0.997. The established method can be used to analyse of NSAIDs of low concentration (ng/mL) in urine.

Electrochemical Investigation of Tryptophan at a Poly(p-aminobenzene sulfonic acid) Film Modified Glassy Carbon Electrode

  • Ya, Yu;Luo, Dengbai;Zhan, Guoqin;Li, Chunya
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.5
    • /
    • pp.928-932
    • /
    • 2008
  • A glassy carbon electrode (GCE) modified with poly(p-aminobenzene sulfonic acid) [Poly(p-ABSA)] film is fabricated by voltammetric technique in phosphate buffer solution (pH 8.0) containing $5.0\;{\times}\;10^{-3}\;mol\;L^{-1}$p- ABSA. Electrochemical behaviors of tryptophan at the Poly(p-ABSA) film electrode are investigated with voltammetry. The results indicate that the electrochemical response of tryptophan is improved significantly in the presence of poly(p-ABSA) film. Compared with the bare glassy carbon electrode, the Poly(p-ABSA) film electrode remarkably enhances the irreversible oxidation peak current of tryptophan. Some parameters such as voltammetric sweeping segments for the electrochemical polymerization, pH, accumulation potential and accumulation time are optimized. Under the optimal conditions, the oxidation peak current is proportional to tryptophan concentration in the range of $1.0\;{\times}\;10^{-7}$ to $1.0\;{\times}\;10^{-6}\;mol\;L^{-1}$, and $2.0\;{\times}\;10^{-6}$ to $1.0\;{\times}\;10^{-5}\;mol\;L^{-1}$ with a detection limit of $7.0\;{\times}\;10^{-8}\;mol\;L^{-1}$. The proposed procedure is successfully applied to the determination of tryptophan in a commercial amino acid oral solution.

Structural Damage Assessment Using Transient Dynamic Response (동적과도응답을 사용한 구조물의 손상진단)

  • 신수봉;오성호;곽임종;고현무
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.4
    • /
    • pp.395-404
    • /
    • 2000
  • A damage detection and assessment algorithm is developed by measuring accelerations at limited locations of a structure under forced vibrations. The developed algorithm applies a time-domain system identification (SI) method that identifies a structure by solving a linearly constrained nonlinear optimization problem for optimal structural parameters. An equation error of the dynamic equilibrium of motion is minimized to estimate optimal parameters. An adaptive parameter grouping scheme is applied to localize damaged members with sparse measured accelerations. Damage is assessed in a statistical manner by applying a time-windowing technique to the measured time history of acceleration. Displacements and velocities at the measured degrees of freedom (DOF) are computed by integrating the measured accelerations. The displacements at the unmeasured DOF are estimated as additional unknowns to the unknown structural parameters, and the corresponding velocities and accelerations we computed by a numerical differentiation. A numerical simulation study with a truss structure is carried out to examine the efficiency of the algorithm. A data perturbation scheme is applied to determine the thresholds lot damage indices and to compute the damage possibility of each member.

  • PDF

Electrospun Non-Directional Zinc Oxide Nanofibers as Nitrogen Monoxide Gas Sensor (전기방사법에 의해 합성된 무방향성 산화아연 나노섬유의 일산화질소 가스 감지 특성)

  • Kim, Ok-Kil;Kim, Hyojin;Kim, Dojin
    • Korean Journal of Materials Research
    • /
    • v.22 no.11
    • /
    • pp.609-614
    • /
    • 2012
  • We report on the NO gas sensing properties of non-directional ZnO nanofibers synthesized using a typical electrospinning technique. These non-directional ZnO nanofibers were electrospun on an $SiO_2$/Si substrate from a solution containing poly vinyl alcohol (PVA) and zinc nitrate hexahydrate dissolved in distilled water. Calcination processing of the ZnO/PVA composite nanofibers resulted in a random network of polycrystalline ZnO nanofibers of 50 nm to 100 nm in diameter. The diameter of the nanofibers was found to depend primarily on the solution viscosity; a proper viscosity was maintained by adding PVA to fabricate uniform ZnO nanofibers. Microstructural measurements using scanning electron microscopy revealed that our synthesized ZnO nanofibers after calcination had coarser surface morphology than those before calcination, indicating that the calcination processing was sufficient to remove organic contents. From the gas sensing response measurements for various NO gas concentrations in dry air at several working temperatures, it was found that gas sensors based on electrospun ZnO nanofibers showed quite good responses, exhibiting a maximum sensitivity to NO gas in dry air at an operating temperature of $200^{\circ}C$. In particular, the non-directional electrospun ZnO nanofiber gas sensors were found to have a good NO gas detection limit of sub-ppm levels in dry air. These results illustrate that non-directional electrospun ZnO nanofibers are promising for use in low-cost, high-performance practical NO gas sensors.

Treatment of Experimental Hydronephrosis Using Renal Artery Embolization and Sclerotherapy in Beagle Dogs (신동맥색전술과 신우경화술을 이용한 비글견의 실험적 수신증 치료)

  • Chang Dong-woo;Lee Young-won;Shin Sang-tae
    • Journal of Veterinary Clinics
    • /
    • v.22 no.2
    • /
    • pp.119-124
    • /
    • 2005
  • This study was performed to validate the procedure of transarterial embolization of the renal artery (TAE-RA) and sclerotherapy of renal pelvis using iohexol-ethanol solution in dogs with unilateral experimental hydronephrosis. Experimental hydronephrosis was induced by unilateral ureter ligation for 20 days in five Beagle dogs. Renal artery embolization with iohexol-ethanol solution was performed using selective catheterization technique in the hydronephrotic kidney and sclerotherapy was done by injection of the iohexol-ethanol solution through percutaneously placed pig-tail catheter. EKG, $SpO_2$ body temperature, pulse, and respiratory rate were within normal ranges during procedures. Average pure ethanol dose for renal artery embolization was $1.1\pm0.3ml/kg$. Renal artery embolization was confirmed by the detection of no blood flow signal at the interlobar and arcuate artery using color Doppler ultrasonography. There were no dogs expired after TAE-RA and sclerotherapy and no side effects associated with regurgitation of iohexol-ethanol solution. The value of BUN, creatinine, ALT, AST, Ca, P in five dogs were within normal range during the experiment period. Ultrasonographically, the mean longitudinal and transverse length and the depth of the embolized kidney significantly decreased at 28 days after TAE-RA. We may conclude that TAE-RA and sclerotherapy with iohexol-ethanol solution is an effective methods for the treatment of unilateral hydronephrosis in dogs.