• Title/Summary/Keyword: detection technique

Search Result 4,102, Processing Time 0.033 seconds

Photonic-Assisted Reactive-Near-Field Analysis of a 3 dB-Tapered Ka-Band Array Antenna

  • Lee, Dong-Joon;Kang, Jeong-Jin;Kang, No-Weon;Kim, Wan-Sik;Park, Wee-Sang;Rothwell, Edward J.;Whitaker, John F.
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.1
    • /
    • pp.18-24
    • /
    • 2010
  • A Ka-band microstrip array antenna for wide-range detection of moving targets is analyzed through a photonicassisted reactive-near-field characterization technique. The antenna array employs a 3-dB-tapered feed network to suppress the sidelobe level while retaining a wide azimuth beamwidth for a wide detection range. The relative nearelectric field patterns of the array and its 3-dB-tapered feed lines have been measured using an electro-optic fieldmapping technique for minimally invasive millimeter-wave sensing. A number of typical limitations on the technique, involving bandwidth, low signal-modulation depth, and high laser-induced noise in high-frequency applications, have been overcome by suppressing the carrier portion of the optical interrogation beam.

Advanced Process Technique for Field Check Data Editing and Structured Editing on Digital Map Ver2.0, Applying Automatic Error Detection Method (자동 오류검출 방법을 적용한 수치지도 Ver2.0 정위치 및 구조화 편집 공정개선 연구)

  • Lee Jin Soo;Park Chang Taek;Park Ki Surk
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.23 no.3
    • /
    • pp.331-340
    • /
    • 2005
  • Digital map is very important digital geographic information which is the base for various fields such as building and using the geographic information system (GIS), planing the regional development, and etc. Therefore, it needs high accuracy. Then we offer the advanced technique which minimizes errors on digital maps, using the automated inspection through the whole figures. In addition this new technique raises the economical efficiency as well as accuracy applying the automated error detection method which can recognize, search and classify errors automatically.

Enhanced detection and serotyping of Streptococcus pneumoniae using multiplex polymerase chain reaction

  • Ahn, Jong Gyun;Choi, Seong Yeol;Kim, Dong Soo;Kim, Ki Hwan
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.11
    • /
    • pp.424-429
    • /
    • 2012
  • Purpose: Methods for quick and reliable detection of Streptococcus pneumoniae are needed for the diagnosis of pneumococcal disease and vaccine studies. This study aimed to show that sequential multiplex polymerase chain reaction (PCR) is more efficient than conventional culture in achieving S. pneumoniae -positive results. Methods: Nasopharyngeal (NP) secretions were obtained from 842 pediatric patients admitted with lower respiratory infections at Severance Children's Hospital in Korea between March 2009 and June 2010. For identification and serotype determination of pneumococci from the NP secretions, the secretions were evaluated via multiplex PCR technique with 35 serotype-specific primers arranged in 8 multiplex PCR sets and conventional bacteriological culture technique. Results: Among the results for 793 samples that underwent both bacterial culture and PCR analysis for pneumococcal detection, 153 (19.3%) results obtained by PCR and 81 (10.2%) results obtained by conventional culture technique were positive for S. pneumoniae. The predominant serotypes observed, in order of decreasing frequency, were 19A (23%), 6A/B (16%), 19F (11%), 15B/C (5%), 15A (5%), and 11A (4%); further, 26% of the isolates were non-typeable. Conclusion: As opposed to conventional bacteriological tests, PCR analysis can accurately and rapidly identify pneumococcal serotypes.

Sensor clustering technique for practical structural monitoring and maintenance

  • Celik, Ozan;Terrell, Thomas;Gul, Mustafa;Catbas, F. Necati
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.2
    • /
    • pp.273-295
    • /
    • 2018
  • In this study, an investigation of a damage detection methodology for global condition assessment is presented. A particular emphasis is put on the utilization of wireless sensors for more practical, less time consuming, less expensive and safer monitoring and eventually maintenance purposes. Wireless sensors are deployed with a sensor roving technique to maintain a dense sensor field yet requiring fewer sensors. The time series analysis method called ARX models (Auto-Regressive models with eXogeneous input) for different sensor clusters is implemented for the exploration of artificially induced damage and their locations. The performance of the technique is verified by making use of the data sets acquired from a 4-span bridge-type steel structure in a controlled laboratory environment. In that, the free response vibration data of the structure for a specific sensor cluster is measured by both wired and wireless sensors and the acceleration output of each sensor is used as an input to ARX model to estimate the response of the reference channel of that cluster. Using both data types, the ARX based time series analysis method is shown to be effective for damage detection and localization along with the interpretations and conclusions.

Detection of Cavities by Inverse Heat Conduction Boundary Element Method Using Minimal Energy Technique (최소 에너지기법을 이용한 역 열전도 경계요소법의 공동 탐지)

  • Choi, C.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.17 no.4
    • /
    • pp.237-247
    • /
    • 1997
  • A geometrical inverse heat conduction problem is solved for the infrared scanning cavity detection by the boundary element method using minimal energy technique. By minimizing the kinetic energy of temperature field, boundary element equations are converted to the quadratic programming problem. A hypothetical inner boundary is defined such that the actual cavity is located interior to the domain. Temperatures at hypothetical inner boundary are determined to meet the constraints of mea- surement error of surface temperature obtained by infrared scanning, and then boundary element analysis is peformed for the position of an unknown boundary (cavity). Cavity detection algorithm is provided, and the effects of minimal energy technique on the inverse solution method are investigated by means of numerical analysis.

  • PDF

A Study on SMiShing Detection Technique using TaintDroid (테인트드로이드를 이용한 스미싱 탐지 기법 연구)

  • Cho, Jiho;Shin, Jiyong;Lee, Geuk
    • Convergence Security Journal
    • /
    • v.15 no.1
    • /
    • pp.3-9
    • /
    • 2015
  • In this paper, a detection technique of smishing using a TaintDroid is suggested. Suggesting system detects malicious acts by transmitting a URL to the TaintDroid server and installing a relevant application to a virtual device of the TaintDroid server, when a smartphone user receives a text message including the URL suspected as a smishing. Through this we want to distinguish an application that can not install because of suspicion of a smishing in an actual smartphone whether said application is malicious application or not by testing with the virtual device of said system. The detection technique of a smishing using the TaintDroid suggested in this paper is possible to detect in a new form a smishing with a text message and to identifying which application it is through analysis of results from a user.

Helium Leak Test for the PLS Storage Ring Chamber (포항가속기 저장링챔버의 헬륨누설검사)

  • Choi, M.H.;Kim, H.J.;Choi, W.C.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.3
    • /
    • pp.31-38
    • /
    • 1993
  • The storage ring vacuum system for the Pohang Light Source (PLS) has been designed to maintain the vacuum pressure of $10^{-10}Torr$ which requires UHV welding to have helium leak rate less than $1{\times}10^{-10}Torr{\cdot}{\ell}/sec$. In order to develop new technique (PLS) welding technique), a prototype vacuum chamber has been welded by using Tungsten Inert Gas welding method and all the welded joints have been tested with a non-destructive method, so called helium leak detection, to investigate the vacuum tightness of the weld joints. The test was performed with a detection limit of $1{\times}10^{-10}Torr{\cdot}{\ell}/sec$ for helium and no detectable leaks were found for all the welded joints. Thus the performance of welding technique is proven to meet the criteria of helium leak rate required in the PLS Storage Ring. Both the principle and the procedure for the helium leak detection are also discussed.

  • PDF

Visual Sensing of Fires Using Color and Dynamic Features (컬러와 동적 특징을 이용한 화재의 시각적 감지)

  • Do, Yong-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.211-216
    • /
    • 2012
  • Fires are the most common disaster and early fire detection is of great importance to minimize the consequent damage. Simple sensors including smoke detectors are widely used for the purpose but they are able to sense fires only at close proximity. Recently, due to the rapid advances of relevant technologies, vision-based fire sensing has attracted growing attention. In this paper, a novel visual sensing technique to automatically detect fire is presented. The proposed technique consists of multiple steps of image processing: pixel-level, block-level, and frame level. At the first step, fire flame pixel candidates are selected based on their color values in YIQ space from the image of a camera which is installed as a vision sensor at a fire scene. At the second step, the dynamic parts of flames are extracted by comparing two consecutive images. These parts are then represented in regularly divided image blocks to reduce pixel-level detection error and simplify following processing. Finally, the temporal change of the detected blocks is analyzed to confirm the spread of fire. The proposed technique was tested using real fire images and it worked quite reliably.

Detection Performance Improvement of STDR/SSTDR Schemes Using Sign Eliminator (부호 제거기를 활용한 STDR/SSTDR 기법의 탐지 성능 개선)

  • Park, So Ryoung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.6
    • /
    • pp.620-627
    • /
    • 2016
  • This paper proposes an advanced detection technique for cable fault by eliminating the sign of reference signal in STDR(sequence time-domain reflectometry) and SSTDR(spread-spectrum time-domain reflectometry). The proposed fault-detection technique can eliminate the reference signal more effectively than the conventional one since the sign detector can approximately recover the distorted reference signal by cable and connector, and consequently, can detect the reflected signal by fault more effectively than the conventional one. Especially, it is shown that the error rate of proposed technique can be significantly lower than the conventional one in the case of far fault simulation.

Neural Net Application Test for the Damage Detection of a Scaled-down Steel Truss Bridge (축소모형 강트러스 교량의 손상검출을 위한 신경회로망의 적용성 검토)

  • Kim, Chi-Yeop;Kwon, Il-Bum;Choi, Man-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.4
    • /
    • pp.137-147
    • /
    • 1998
  • The neural net application was tried to develop the technique for monitoring the health status of a steel truss bridge which was scaled down to 1/15 of the real bridge for the laboratory experiments. The damage scenarios were chosen as 7 cases. The dynamic behavior, which was changed due to the breakage of the members, of the bridge was investigated by finite element analysis. The bridge consists of single spam, and eight (8) main structural subsystems. The loading vehicle, which weighs as 100 kgf, was operated by the servo-motor controller. The accelerometers were bonded on the surface of 7 cross-beams to measure the dynamic behavior induced by the abnormal structural condition. Artificial neural network technique was used to determine the severity of the damage. At first, the neural net was learnt by the results of finite element analysis, and also, the maximum detection error was 3.65 percents. Another neural net was also learnt, and verified by the experimental results, and in this case, the maximum detection error was 1.05 percents. In future study, neural net is necessary to be learnt and verified by various data from the real bridge.

  • PDF