• Title/Summary/Keyword: detection technique

Search Result 4,105, Processing Time 0.036 seconds

Matching Pursuit Approach for Guided Wave-based Damage Inspection (유도 초음파 이용 결함 진단을 위한 정합추적 기법)

  • Hong, Jin-Chul;Sun, Kyung-Ho;Kim, Yoon-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.4 s.97
    • /
    • pp.382-387
    • /
    • 2005
  • For successful guided-wave damage inspection, the appropriate signal processing of measured wave signals is very important. The objective of this paper is to introduce an efficient signal processing technique especially suitable for the guided-waves used for damage detection. The key idea of this technique is to model guided-waves by chirp functions of special form considering the dispersion phenomenon. To determine the parameter of the chirp functions simulating guided-waves, the matching pursuit algorithm is employed. The damage information in waveguides can be extracted by pulse-characterizing parameters. The effectiveness of present method is checked with the guided wave-based damage inspection.

3D Particle Image Detection by Using Color Encoded Illumination System

  • Kawahashi M.;Hirahara H.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.100-107
    • /
    • 2001
  • A simple new technique of particle depth position measurement, which can be applied for three-dimensional velocity measurement of fluid flows, is proposed. Two color illumination system that intensity is encoded as a function of z-coordinate is introduced. A calibration procedure is described and a profile of small sphere is detected by using the present method as preliminary test. Then, this method is applied to three-dimensional velocity field measurement of simple flow fields seeded with tracer particles. The motion of the particles is recorded by color 3CCD camera. The particle position in the image plane is read directly from the recorded image and the depth of each particle is measured by calculation of the intensity ratio of encoded two color illumination. Therefore three-dimensional velocity components are reconstructed. Although the result includes to some extent error, the feasibility of the present technique for three-dimensional velocity measurement was confirmed.

  • PDF

An Improvement of Signal Processing of Pulse Oximeter Using Modulization (모듈화를 이용한 펄스 옥시메터의 신호처리 개선)

  • 이한욱;이주원;이종희;조원래;장두봉;김영일;이건기
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.117-120
    • /
    • 2000
  • Pulse oximetry is a well established non-invasive optical technique for monitoring the SpO$_2$ during anaesthesia, recovery and intensive care. Pulse oximeters determine the oxygen saturation level of blood by measuring the light absorption of arterial blood. The sensors consists of red and infrared light sources and photodetectors. In the measurement of the hemoglobin oxygen saturation, conventional method has required the technique of filtering of remove the noise, and of complex signal processing algorithm. So much time have required to signal processing. In this research, we separate AC signal and DC signal in the stage of signal detection. We filter the noise from each signal and convert A/D. We obtain the SpO$_2$ using the DSP algorithm.

  • PDF

Sensorless control of PMSM in low speed range using high frequency voltage injection (전압주입 방식을 이용한 PMSM 센서리스 제어에 관한 연구)

  • Yoon Seok-chae;Kim Jang-mok
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.119-122
    • /
    • 2003
  • This paper describes the sensorless technique for the surface-mounted permanent-magent synchronous motor(SPMSM or PMSM) drive based on magnetic saliency. The control technique is a sensorless control algorithm that injects the high frequency voltage to the stator terminal in order to estimate the rotor position and speed. The rotor position and speed for sensorless vector control is achieved by appropriate signal processing to extract the position information from the stator current in the low speed range including zero speed. Proposed sensorless algorithm using the double-band hysteresis controller and initial rotor position detection exhibits excellent reference tracking and increased robustness. Experimental results are presented to verify the feasibility of the proposed control schemes.

  • PDF

High frequency partial discharge measurement by metal foil electrode (박전극을 이용한 고주파 부분방전 측정 연구)

  • Kim, C.S.;Shin, D.S.;Lee, C.Y.;Kim, J.N.;Baek, J.H.;Kim, D.W.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1081-1083
    • /
    • 1999
  • The capacitive coupling technique has been used as conventional method for PD detection on the power cable line. Recently, however PD measurement using by high frequency is known to have an excellent sensitivity comparison with low frequency on-site. In this paper, the high frequency characteristic of two type of metal foil sensor was studied and the technique was proved to be more effective diagnostic method than conventional method for qualification of EHV cable and accessories.

  • PDF

A Study on the Characteristics of Steering Angle Sensor using Magnetic Induction (자기유도를 이용한 조향각 센서의 특성 연구)

  • Kim, Byeong-Woo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.2
    • /
    • pp.48-55
    • /
    • 2010
  • We have development the steering angle sensor using not only detecting parts but also integrating technique with semiconductors for automobile applications. The performance design and analysis of the steering angle sensor for intelligent vehicles is complicated due to variety of parameters. In this study, the performance characteristics of the angle sensor were analyzed using test rig. By means of magnetic induction technique, these new the steering angle sensors showed excellent magnetic characteristics. The detection range of steering angle sensor obtained was ${\pm}800^{\circ}$, the maximum non-linearity is 0.744% Full Span and the temperature range was $-40^{\circ}C{\sim}+125^{\circ}C$. With this conclusive, the inductive angle sensor was quite satisfactory for many applications in intelligent vehicles.

Micro-PIXE as a Technique for Multi-elemental Detection and Localization in Various Atmospheric Environmental Samples

  • Ma, Chang-Jin;Choi, Sung-Boo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.E1
    • /
    • pp.54-62
    • /
    • 2008
  • Microbeam PIXE, often called micro-PIXE, is one of powerful tools for analyzing a wide range of elements for various samples. Moreover, it has important applications of interest to the atmospheric science. In the present study, a qualitative elemental imagination for various atmospheric environmental species was attempted using micro-PIXE. Especially, in combination with a novel individual droplet collection method and the micro-PIXE analytical technique, the chemical specification of various individual atmospheric samples could be carried out. Here, we briefly introduce the results of an application of micro-PIXE to the study of atmospheric environment. The detailed spatial resolution of multiple elements for various samples like individual ambient particles, individual raindrops, individual fog droplets, and individual snow crystals could be successfully achieved by scanning 2.6 MeV $H^+$ micro beam ($1{\sim}2{\mu}m$) accelerated by 3 MeV single-end accelerator.

Ultrasonic Evaluation of Worn Surface (초음파를 이용한 마멸표면 평가)

  • 안효석;김두인
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.233-239
    • /
    • 1999
  • The feasibility of an ultrasonic technique using a pulse-echo method of normal-incident compressional waves was evaluated for its sensitivity to the worn surface and near surface damage due to wear. Worn surfaces were generated at various oscillation frequency under a given load and amplitude and these surface were in situ monitored using a ultrasonic wave detection system. Analysis of the ultrasonic waves received from the worn surface revealed a close relationship between the surface and near-surface damage and the maximum echo-amplitude of the compressional waves. The ultrasonic technique was successful in assessing the level of severity of the worn surface in real time during the wear process. It is also shown that the wear depth can be easily measured by the calculation of change of the specimen thickness based on the wave speed measured for the specimen medium.

  • PDF

Low Attenuation Waveguide for Structural Health Monitoring with Leaky Surface Waves

  • Bezdek, M.;Joseph, K.;Tittmann, B.R.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.3
    • /
    • pp.241-262
    • /
    • 2012
  • Some applications require structural health monitoring in inaccessible components. This paper presents a technique useful for Structural Health Monitoring of double wall structures, such as double wall steam pipes and double wall pressure vessels separated from an ultrasonic transducer by three layers. Detection has been demonstrated at distances in excess of one meter for a fixed transducer. The case presented here is for one of the layers, the middle layer, being a fluid. For certain transducer configurations the wave propagating in the fluid is a wave with low velocity and attenuation. The paper presents a model based on wave theory and finite element simulation; the experimental set-up and observations, and comparison between theory and experiment. The results provide a description of the technique, understanding of the phenomenon and its possible applications in Structural Health Monitoring.

Analysis of 3-Dimensional Hydrodynamic Focusing in Circular Capillary Tube and Rectangular Microchannel (원형 모세관과 사각형 단면의 미세채널에서 3차원 수력학적 집속유동 분석)

  • Yoon, Seong-Hee;Kim, Kyung-Hoon;Kim, Jung-Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.2
    • /
    • pp.21-26
    • /
    • 2011
  • Hydrodynamic focusing technique to generate focused flow has been used for flow cytometry in microfluidic devices. However, devices with circular capillary tubes made of glass are not suitable for flow visualization or optical signal detection because the rays of light are distorted at the curved interface. We devised a new acrylic chamber assembled with a pulled micropipette and a rectangular microchannel made of glass. This new channel geometry enabled us to visualize the three-dimensional (3D) flow characteristics with confocal imaging technique. We analyzed the 3D hydrodynamic focusing in a circular capillary tube and a rectangular microchannel over a practical range of flow rates, viscosities and pressure drops.