• Title/Summary/Keyword: design formula

Search Result 1,322, Processing Time 0.033 seconds

Estimation of the Fundamental Period for Residential Buildings with Shear-Wall System

  • Chun, Young-Soo;Chang, Kug-Kwan;Lee, Li-Hyung
    • KCI Concrete Journal
    • /
    • v.12 no.1
    • /
    • pp.121-130
    • /
    • 2000
  • This study focused on evaluating the reliability of code formulas such as those of the current Korean Building Code(KBC 1988). UBC 1997, NBCC 1995. and BSLJ 1994 for estimating the fundamental period of RC apartment buildings with shear-wall dominant systems, representative of typical residential buildings in Korea. For this purpose, full-scale measurements were carried out on fifty RC apartment buildings, and these results were compared to those obtained by code formulas and also by dynamic analysis. Although these code formulas are based on the measured periods of buildings during various earthquakes and building period varies with the amplitude of structural deflection or strain level, ambient surveys should provide an effective tool for experimentally verifying the design period to the completed building. This comparison shows that comparatively large errors are likely to occure when the code formula of KBC 1988 is used, and all the other code formulas are not sufficient to estimate the fundamental period of apartment buildings with shear-wall dominant systems. An improved formula is proposed by regression analysis on the basis of the measured period data. The proposal is for the servicebility stress level, but it can also be applied for seismic code in the regions of low seismicity similar to Korea.

  • PDF

A Study on Behavior of the Earth Retaining Structure by Field Measurement and Numerical Analysis (현장계측과 수치해석에 의한 흙막이구조물의 거동 비교분석)

  • Wo, Jongtae
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.286-295
    • /
    • 2017
  • In this study, it is compared various coefficients of subgrade reaction for application of numerical analysis based on measured data by using various theories and empirical formula. The ratio of the maximum and minimum value is 6.80 at the top of wall but it is 1.06 at the maximum displacement point depends on change of calculated coefficient of subgrade reaction. The data of displacement were generally similar considering an increment of a coefficient of subgrade reaction. And the results of comparison of the displacement at the maximum displacement point by numerical analysis and measured data show similar displacement shape.

Study on Accuracy of Product by Radial Deformation of Die in Backward Extrusion (후방압출 공정에서 금형의 반경반향 변형량을 통한 제품정밀도에 관한 연구)

  • 이강희;박태식;박용복
    • Transactions of Materials Processing
    • /
    • v.12 no.5
    • /
    • pp.498-503
    • /
    • 2003
  • The die for cold forging gets a very high axial load and radial pressure during processing and hence deforms considerably in the radial direction. This radial deformation of die becomes a important factor influencing the dimensional accuracy of a product. In order to obtain the product with highly accurate dimension, therefore, it is essential to acquire some information on elastic deformation of the die and the product. The study has been performed for the relation of the deformation between the die and the product in backward extrusion. The strain of the die has been given by the simple experiment using the strain gauges attached to the outer surface of the die. Also the history of the deformation of the die and the product has been given by the experiment and Lames' formula. The results has been compared with the previous another method. The study has given useful results for the deformation history of the die and the product through the experiment and Lame's formula in backward extrusion, which can be applied in the die design for the product with accurate dimension.

Estimating UCS of cement-grouted sand using characteristics of sand and UCS of pure grout

  • Lee, Changho;Nam, Hongyeop;Lee, Woojin;Choo, Hyunwook;Ku, Taeseo
    • Geomechanics and Engineering
    • /
    • v.19 no.4
    • /
    • pp.343-352
    • /
    • 2019
  • For quality control and the economical design of grouted sand, the prior establishment of the unconfined compressive strength (UCS) estimating formula is very important. This study aims to develop an empirical UCS estimating formula for grouted sand based on the physical properties of sands and the UCS of cured pure grout. Four sands with varying particle sizes were grouted with both microfine cement and Ordinary Portland cement. Grouted specimens were prepared at three different relative densities and at three different water-to-cement ratios, and unconfined compression tests were performed. The results demonstrate that UCS of grouted sand can be expressed as the power function of the UCS of cured pure grout: $UCS_{grouted\;sand}/1MPa=A_{soil}{\cdot}(UCS_{pure}/1MPa)^N$. Because the exponent N strongly depends on the combination of pore area and pore size, N is expressed as the function of porosity (n) and specific surface ($S_a$). Additionally, because $S_a$ determines the area of the sand particle that cement particles can adsorb and n determines the number of cementation bondings between sand particles, $A_{soil}$ is also expressed as the function of n and $S_a$. Finally, the direct relationship between $A_{soil}$ and N is also investigated.

A Comparison Study on Mechanical Properties of XLPE Insulation Thermally Degraded at Equivalent and Variable Temperature Conditions (XLPE 절연체의 등가 및 가변온도 가속열화실험을 통한 기계적 특성 비교 분석)

  • Taejoon, Kim;Jae-Sang, Hwang;Sung Hoon, Jung;Tae Young, Kim
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.73-77
    • /
    • 2022
  • Recently, as the number of years of operation has increased for more than 30 years, interest in evaluating the remaining life of major power facilities such as transformers and ultra-high voltage cables is increasing. In particular, the risk of failure is increasing because the underground transmission XLPE cable has been built since 1980 and has been operating in excess of 30 years of design life or close proximity. Therefore, it is necessary to develop an algorithm to evaluate the residual life of the XLPE cable considering the load to determine the risk of failure. Since load data is large amount of data, it is necessary to make the variable load information equivalent to the time unit first in order to calculate the remaining life of the system quickly. In overseas literature, transformers are reported to be standardized for variable load equivalent conversion formulas, but they have not been reported for ultra-high voltage cables. Therefore, in this paper, whether the equivalent conversion formula of a transformer can be applied to XLPE cables was reviewed through accelerated degradation tests under equivalent and variable temperature conditions, and considerations were studied when evaluating the remaining operating life of XLPE cables based on the experimental results.

Research on flexural bearing capacity of cold-formed thin-walled steel and reinforced concrete sandwich composite slabs

  • Qiao, Wentao;Huang, Zhiyuan;Yan, Xiaoshuo;Wang, Dong;Meng, Lijun
    • Steel and Composite Structures
    • /
    • v.45 no.2
    • /
    • pp.219-230
    • /
    • 2022
  • The aim of this paper is to study the mechanical behaviors of the cold-formed thin-walled steel and reinforced concrete sandwich composite slab (CTS&RC-SCS) under vertical loads and to develop the calculation methods of its flexural bearing capacity and section stiffness. Two CTS&RC-SCS specimens were designed and manufactured to carry out the static loading test, and meanwhile, the numerical simulation analyses based on finite element method were implemented. The comparison between experimental results and numerical analysis results shows that the CTS&RC-SCS has good flexural capacity and ductility, and the accuracy and rationality of the numerical simulation analysis are verified. Further, the variable parameter analysis results indicate that neither increasing the concrete strength grade nor increasing the thickness of C-sections can significantly improve the flexural capacity of CTS&RC-SCS. With the increase of the ratio of longitudinal bars and the thickness of the composite slab, the flexural capacity of CTS&RC-SCS will be significantly increased. On the basis of experimental research and numerical analysis above, the calculation formula of the flexural capacity of CTS&RC-SCS was deduced according to the plastic section design theory, and section stiffness calculation formula was proposed according to the theory of transformed section. In terms of the ultimate flexural capacity and mid-span deflection, the calculated values based on the formulas and the experimental values are in good agreement.

On compressive behavior of large welded hollow spherical joints with both internal and external stiffeners

  • Tingting Shu;Xian Xu;Yaozhi Luo
    • Steel and Composite Structures
    • /
    • v.46 no.2
    • /
    • pp.211-220
    • /
    • 2023
  • Welded hollow spherical joints are commonly used joints in space grid structures. An internal stiffener is generally adopted to strengthen the joints when large hollow spheres are used. To further strengthen it, external stiffeners can be used at the same time. In this study, axial compression tests are conducted on four full-scale 550 mm spherical joints. The failure modes and strengths of the tested joints are investigated. It shows that the external stiffeners are able to increase the strength of the joint up to 25%. A numerical model for large spherical joints with stiffeners is established and verified against the experimental results. Parametric studies are executed considering six main design factors using the verified model. It is found that the strength of the spherical joint increases as the thickness, height and number of the external stiffeners increase, and the hollow sphere's diameter has a neglectable effect on the enhancement caused by the external stiffeners. Based on the experimental and numerical results, a practical formula for the compressive bearing capacity of large welded hollow spherical joints with both internal and external stiffeners is proposed. The proposed formula gives a conservative prediction on the compressive capacity of large welded hollow spherical joints with both internal and external stiffeners.

A Study on the Comparative Analysis of Hand Calculations and Fire Simulation for Estimating Fire Spread Paths in Jecheon Sports Center (제천스포츠센터 화재확산경로 추정을 위한 예측식 및 화재시뮬레이션 비교 분석에 관한 연구)

  • Choi, Yun-Ju;Kim, Yun-Seong;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.51-52
    • /
    • 2022
  • In previous studies, fire simulation was used to estimate the fire spread path. According to previous studies, the fire spread path was estimated to be the main staircase, but consideration of interior materials and internal bulkheads was insufficient. In this study, the ignition time of the 3rd layer was analyzed using the prediction formula considering the interior materials and internal bulkheads. As a result of referring to the architectural drawings, it was found that the interior material of the 3rd floor was made of polystyrene. The internal ignition time of the third floor using FDTs was calculated to be 14,070 seconds (about 234 minutes). The internal ignition time of the 3rd floor using the Handbook on Design Calculation Methods of Fire Behavior was calculated to be 3,104 seconds (about 51 minutes). As a result of calculating the ignition time through the predictive formula, there is a large difference in the ignition time, so it is necessary to review the condition of the variable as a result of the calculation in the future.

  • PDF

Tension estimation method using natural frequencies for cable equipped with two dampers

  • Aiko Furukawa;Kenki Goda;Tomohiro Takeichi
    • Structural Monitoring and Maintenance
    • /
    • v.10 no.4
    • /
    • pp.361-379
    • /
    • 2023
  • In cable structure maintenance, particularly for cable-stayed bridges, cable safety assessment relies on estimating cable tension. Conventionally, in Japan, cable tension is estimated from the natural frequencies of the cable using the higher-order vibration method. In recent years, dampers have been installed on cables to reduce cable vibrations. Because the higher-order vibration method is a method for damper-free cables, the damper must be removed to measure the natural frequencies of a cable without a damper. However, cables on some cable-stayed bridges have two dampers: one on the girder side and another on the tower side. Notably, removing and reinstalling the damper on the tower side are considerably more time- and labor-intensive. This paper introduces a tension estimation method for cables with two dampers, using natural frequencies. The proposed method was validated through numerical simulation and experiment. In the numerical tests, without measurement error in the natural frequencies, the maximum estimation error among 100 models was 3.3%. With measurement error of 2%, the average estimation error was within 5%, with a maximum error of 9%. The proposed method has high accuracy because the higher-order vibration method for a damper-free cable still has an estimation error of 5%. The experimental verification emphasizes the importance of accurate damper modeling, highlighting potential discrepancies between existing damper design formula and actual damper behavior. By revising the damper formula, the proposed method achieved accurate cable tension estimation, with a maximum estimation error of approximately 10%.

A Study on the Factors affecting Korean Medical Students' Satisfaction with Education and Trust in Korean Medicine (한의대생의 교육 만족도 및 한의학 신뢰도에 대한 영향 요인 연구)

  • Yejin Han
    • Herbal Formula Science
    • /
    • v.32 no.1
    • /
    • pp.91-98
    • /
    • 2024
  • Objective : This study aimed to investigate Korean medical students' satisfaction with Korean medicine education and their trust in Korean medicine. It also explored the factors affecting satisfaction with Korean medicine education and trust in Korean medicine. Methods : Based on a total of 381 survey responses, the satisfaction with Korean medicine education, reflection of educational needs, trust in Korean medicine, reasons for maladjustment to education, and suggestions for improving education were analyzed. Results : Satisfaction with Korean medicine education and trust in Korean medicine were generally above average. However, reflection of educational needs was below average. It was found that the curriculum should be rearranged according to the needs of premedical students and medical students. The factors affecting satisfaction with Korean medicine education were gender, academic year, dropout experience, trust in Korean medicine, and reflection of educational needs. Factors affecting trust in Korean medicine were gender, academic year, and satisfaction with Korean medicine education. Conclusion : This study found that satisfaction with Korean medicine education and trust in Korean medicine have a reciprocal relationship. To improve students' satisfaction and adjustment to Korean medicine education, it is necessary to implement strategies to increase students' trust in Korean medicine. In addition, it is important for students and instructors to collaborate on curriculum design by establishing a feedback system that reflects students' needs.