• Title/Summary/Keyword: desalination plant

Search Result 112, Processing Time 0.022 seconds

Optimization of energy efficiency through comparative analysis of factors affecting the operation with energy recovery devices on SWRO desalination process (역삼투막 해수담수화 공정에서 에너지 회수장치의 운영인자 비교분석을 통한 에너지 효율 최적화 연구)

  • Kim, Pooreum;Kim, Hyungsoo;Park, Junyoung;Kim, Taewoo;Kim, Minjin;Park, Kitae;Kim, Jihoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • Recently, interest in the development of alternative water resources has been increasing rapidly due to environmental pollution and depletion of water resources. In particular, seawater desalination has been attracting the most attention as alternative water resources. As seawater desalination consumes a large amount of energy due to high operating pressure, many researches have been conducted to improve energy efficiency such as energy recovery device (ERD). Consequently, this study aims to compare the energy efficiency of RO process according to ERD of isobaric type which is applied in scientific control pilot plant process of each $100m^3/day$ scale based on actual RO product water. As a result, it was confirmed that efficiency, mixing rate, and permeate conductivity were different depending on the size of the apparatus even though the same principle of the ERD was applied. It is believed that this is caused by the difference in cross-sectional area of the contacted portion for pressure transfer inside the ERD. Therefore, further study is needed to confirm the optimum conditions what is applicable to the actual process considering the correlation with other factors as well as the factors obtained from the previous experiments.

Study on the Necessity of Energy Recovery Device in Small Scale Reverse Osmosis Desalination Plant (소규모 역삼투 담수화 시설에서 에너지 회수장치의 필요성에 대한 연구)

  • Jeon, Jongmin;Kwak, Kyungsup;Kim, Noori;Jung, Jaehak;Son, Dong-Min;Kim, Suhan
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.762-766
    • /
    • 2017
  • Energy recovery device (ERD) is used to save energy consumption in seawater reverse osmosis processes. However, small-scale ERDs (<$100m^3/d$) are hardly observed in seawater desalination market. In South Korea, most of seawater desalination plants for drinking water production are small-scaled and have been operated in island areas or on ships. Thus, the effect of ERDs for these small-scale SWRO processes should not be neglected. In this work, the small-scale SWRO processes are designed and analyzed in terms of energy consumption with/without ERD. The realistic efficiencies of high pressure pumps are considered for the energy analyses. The unit cost of electricity depending on the application place (e.g., inland and island areas, on ships) is investigated to calculate the energy cost for unit water production in various SWRO applications classified by plant capacity, application place, and the installation of ERD. As a result, the energy cost can be saved up to $1,640.4KRW/m^3$ when ERD is applied, and the saving effect increases at smaller plants on ships. In conclusion, the development of small-scale ERDs are necessary because small-scale SWRO processes are dominant in Korean seawater desalination market, and the electricity saving effect becomes higher at smaller-scaled system.

Simulation study of DAF flotation basin using CFD (전산유체해석기법을 이용한 용존공기부상공정의 유동해석)

  • Park, Byungsung;Woo, Sungwoo;Park, Sungwon;Min, Jinhee;Lee, Woonyoung;You, Sunam;Jun, Gabjin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.261-272
    • /
    • 2013
  • Algae boom (Red tide) in south coastal area of Korea has been appeared several times during a decade. If algae boom appears in the desalination plant, media filter and UF filter are clogged quickly, and the plant should be shutdown. In general, Algae can be removed from water by flotation better than by sedimentation, because of the low density of algal cell. The purpose of this study conducts the CFD simulation of DAF flotation basin to apply the design of the dissolved air flotation with ball filter in the Test Bed for SWRO desalination plant. In this study, Eulerian-Eulerian multiphase model was applied to simulate the behavior of air bubbles and seawater. Density difference model and gravity were used. But de-sludge process and mass transfer between air bubbles and seawater were ignored. Main parameter is hydraulic loading rate which is varied from 20 m/hr to 27.5 m/hr. Geometry of flotation basin were changed to improve the DAF performance. According to the result of this study, the increase of hydraulic loading rate causes that the flow in the separation basin is widely affected and the concentration of air is increased. The flow pattern in the contact zone of flotation basin is greatly affected by the location of nozzle header. When the nozzle header was installed not the bottom of the contact zone but the above, the opportunity of contact between influent and recycle flow was increased.

Economic Analysis of Geothermal Energy and VMD Desalination Hybrid Process (지열에너지와 진공 막 증류법을 활용한 해수담수화 연계형 공정의 경제성 분석)

  • Park, Kiho;Kim, Jin Hyun;Kim, Hyuk Soo;Lee, Kwan-Young;Yang, Dae Ryook;Kim, Kyung Nam
    • Clean Technology
    • /
    • v.20 no.1
    • /
    • pp.13-21
    • /
    • 2014
  • Because of the water scarcity caused by the increase of salinity in the underground water, seawater desalination stands out as one of the most promising solution. As there are so much energy costs in operating desalination plants, new hybrid process which is more effective should be researched. A geothermal VMD (vacuum membrane distillation) hybrid process is a competitive alternative for seawater desalination. Because geothermal energy has significant characteristics of high capacity factor to operate the power plant at full capacity for 24 hour per day, it can be a priority heat source of VMD superior to any other renewable energies such as solar and wind power. In this study, we design a geothermal VMD hybrid process, analyze it economically and finally compare the result with a case of conventional VMD process. Geothermal VMD hybrid process generates $23,822,409 of NPV (net present value) more than the conventional VMD process in case of 5% discount rate. The break-even point between these processes is 5.36 year. Sensitivity analysis indicates that steam cost is the most decisive influence variable to the economic outcome.

Development of a predictive model of the limiting current density of an electrodialysis process using response surface methodology

  • Ali, Mourad Ben Sik;Hamrouni, Bechir
    • Membrane and Water Treatment
    • /
    • v.7 no.2
    • /
    • pp.127-141
    • /
    • 2016
  • Electrodialysis (ED) is known to be a useful membrane process for desalination, concentration, separation, and purification in many fields. In this process, it is desirable to work at high current density in order to achieve fast desalination with the lowest possible effective membrane area. In practice, however, operating currents are restricted by the occurrence of concentration polarization phenomena. Many studies showed the occurrence of a limiting current density (LCD). The limiting current density in the electrodialysis process is an important parameter which determines the electrical resistance and the current utilization. Therefore, its reliable determination is required for designing an efficient electrodialysis plant. The purpose of this study is the development of a predictive model of the limiting current density in an electrodialysis process using response surface methodology (RSM). A two-factor central composite design (CCD) of RSM was used to analyze the effect of operation conditions (the initial salt concentration (C) and the linear flow velocity of solution to be treated (u)) on the limiting current density and to establish a regression model. All experiments were carried out on synthetic brackish water solutions using a laboratory scale electrodialysis cell. The limiting current density for each experiment was determined using the Cowan-Brown method. A suitable regression model for predicting LCD within the ranges of variables used was developed based on experimental results. The proposed mathematical quadratic model was simple. Its quality was evaluated by regression analysis and by the Analysis Of Variance, popularly known as the ANOVA.

Comprehensive Analysis of Major Factors Associated with the Performance of Reverse Osmosis Desalination Plant for Energy-saving (에너지 소모를 고려한 역삼투 해수담수화 플랜트 주요 성능인자 영향 분석)

  • Kim, Jihye;Lee, Kyung-Hyuk;Lim, Jae-Lim
    • Membrane Journal
    • /
    • v.29 no.6
    • /
    • pp.314-322
    • /
    • 2019
  • A worsened drought in Chungnam province of Korea due to climate change and increasing water demand at Daesan industrial complex have motivated the 100,000 ㎥/d seawater desalination project. In this study, therefore, the comprehensive analysis of parameters affecting the reverse osmosis (RO) performance was conducted. Under the various conditions of feedwater salinity and temperature in Daesan, energy consumption was calculated as 2.39 ± 0.13 kWh/㎥. The decrease in membrane flux and recovery rate positively impacted annual operation cost. The average total dissolved solids (TDS) of the permeate and energy consumption with highly permeable membrane according to the membrane manufacturer were 3.84 mg/L and 2.22 ± 0.13 kWh/㎥, respectively. In addition, energy saving up to 0.29 kWh/㎥ or cost reduction of membrane module up to 15.6% is expected by changing the RO configuration from full two pass to partial or split partial two pass.

Effect of Pretreated Seawater Quality on SDI in SWRO Desalination Process (SWRO 해수담수화 공정에서 전처리된 수질조건이 SDI에 미치는 영향)

  • Son, Dong-Min;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.3
    • /
    • pp.200-205
    • /
    • 2013
  • Pretreatment process is the critical step of RO (Reverse Osmosis) membrane desalination plant in order to prevent RO membrane fouling. The pretreatment as a key component of RO process must be designed to produce a constant and high quality RO feedwater which has low silt density index (SDI). This experiment was conducted to assess parameters affecting SDI value, such as pH, seawater turbidity, temperature, and coagulant dose. The experimental results indicated that the source seawater turbidity did cause little effects on SDI values of filtered water. The 0.45 um hydrophilic membrane was more appropriate than the hydrophobic membrane for measuring SDI. The SDI value was increased with decreasing pH under the condition of below pH 7.0. In addition, the water temperature significantly affected the SDI values, showing higher SDI value with lower water temperature.

Ecological studies of the certain Halophytes on the high saline soil (고염도 토양에 있어서 몇가지 염식생식물의 생태에 대하여)

  • 홍순우
    • Journal of Plant Biology
    • /
    • v.13 no.1
    • /
    • pp.25-32
    • /
    • 1970
  • Ecological study on the reclaimed high saline soil was carried out throughout a year(1969) to elucidate the changes of the structure of halophytes communiteis and the possibilities of desalination from high saline soil by absorption of chloride ion. Results from this studies are summarized as followings; 1) The growth rates of halophytes showed a variation; maximum growth rate of Salicornia appeared on August, Chenopodium on July, Suaeda on July, Aster on August and Scirpus on June. 2) Changes of frequency of each halophyte were varied in accordance with species. Chenopodium and Salicornia have the highest frequency of all on May. However, frequency as well as density of halophytes decreased after on May due to competition for absorbing moisture in plant communities. 3) The terrestrial plants which were succeed into the reclaimed tidal land had herborized 25 species on the both side of irrigation route. 4) Each of the maximum chloride uptake by halophytes appeared on May(Salicornia and Aster), on June(Chenopodium and Scirpus), and on August(Suaeda), respectirecely 5) Among the halophytes, Salicornia was confirmed to absorb the highest amount of chloride. A possible amount of chloride uptake by all halophytes per 100 square cm reached about 24,629. ppm.

  • PDF

Classification of Soil Desalination Areas Using High Resolution Satellite Imagery in Saemangeum Reclaimed Land

  • Lee, Kyung-Do;Baek, Shin-Chul;Hong, Suk-Young;Kim, Yi-Hyun;Na, Sang-Il;Lee, Kyeong-Bo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.6
    • /
    • pp.426-433
    • /
    • 2013
  • This study was aimed to classify soil desalination area for cultivation using NDVI (Normalized difference vegetation index) of high-resolution satellite image because the soil salinity affects the change of plant community in reclaimed lands. We measured the soil salinity and NDVI at 28 sites in the Saemangeum reclaimed land in June 2013. In halophyte and non-vegetation sites, no relation was found between NDVI and soil salinity. In glycophyte sites, however, we found that the soil salinity was below 0.1% and NDVI ranged from 0.11 to 0.57 which was greater than the other sites. So, we could distinguish the glycophyte sites from the halophyte sites and non-vegetation, and classify the area that soil salinty was below 0.1%. This technique could save the time and labor to measure the soil salinity in large area for agricultural utilization.