• 제목/요약/키워드: depth radiation

검색결과 637건 처리시간 0.026초

STUDY ON THE ELECTRON GENERATION BY A MICRO-CHANNEL PLATE BASED ON EGS4 CALCULATIONS AND THE UNIVERSAL YIELD CURVE

  • Moon, B.S.;Han, S.H.;Kim, Y.K.;Chung, C.E.
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.177-181
    • /
    • 2001
  • The conversion efficiency of a cesium iodine coated micro-channel plate is studied. We use the EGS4 code to transport photons and generated electrons until their energies become less than 1keV and 10keV respectively. Among the generated electrons, the emission from the secondary electrons located within the escape depth of 56nm from the photo-converter boundary is estimated by integrating the product of the secondary electrons with a probability depending only on their geometric locations. The secondary electron emission from the generated electrons of energy higher than 100eV is estimated by the 'universal yield curve'. The sum of these provides an estimate for the secondary electron yield and we show that results of applying this algorithm agree with known experimental results. Using this algorithm, we computed secondary electron emissions from a micro-channel plate used in a gas electron multiplier detector that is currently being developed at Korea Atomic Energy Research Institute.

  • PDF

A Study of Three-dimension Tissue Equivalent Compensator for 6MV X-Rays (6MV X-선에 대한 삼차원적 조직보상체의 연구)

  • Kim, Ok-Bae;Choi, Tae-Jin;Suh, Soo-Jhi
    • Radiation Oncology Journal
    • /
    • 제7권1호
    • /
    • pp.133-140
    • /
    • 1989
  • Three-dimension paraffin compensator was designed to construct the tissue equivalent compensator for irregular body contours and obiliques beam incidence. The ratio of compensator thickness to tissue deficit was depended on field size, depth and air gap because the scattered dose loss. The ratio of compensator-tissue was optimized 0.79, 0.73, 0.61 and 0.56 in 6MV x-rays as function of field size $4{\times}4$, $10{\times}10$, $20{\times}20$ and $30{\times}30cm^2$ respectively. in our study. Using this tissue equivalent compensator, it can be got 2% difference of dose at same mid-plane in phantom study.

  • PDF

Cs-137 distribution around Kori Nuclear Power Plant

  • Lee, H.;Kang, H.S.;Choi, H.J.;Yu, D.H.;Lim, K.M.;Choi, Y.H.
    • Journal of Radiation Protection and Research
    • /
    • 제28권4호
    • /
    • pp.349-351
    • /
    • 2003
  • To ensure the safety of the currently operating nuclear power plant, the Periodic Safety Review program has been conducted. In PSR program, the cumulative behavior of the radionuclide that might be released from the power plant is addressed. The Cs-137 in soil around Kori nuclear power plant was investigated. The soil sample was analyzed and compared with the reference area. The model calculation explained the depth profile of Cs-137.

Physiological and Ecological Studies of the Vegetation on Ore Deposits (금속광물상에 나타나는 식물에 관한 생리생태학적 연구 3. 괴산 우라늄광지대 식물의 방사선생태학적 징상)

  • Chang, Nam Kee;Chang Soo Mok
    • The Korean Journal of Ecology
    • /
    • 제5권4호
    • /
    • pp.137-142
    • /
    • 1982
  • From 1975 to 1981, the survey was carried out to find out radioecological effects of uranium ore deposits on natural vegetation in Koisan, Korea. The symptoms of spotty and mosaic chlorosis, and necrosis were observed in flowering plants in the areas of uranium ore deposits at Deok-Peung-Ri A, B, and C in Koisan. Although 13 species were found to be chlorosis and necrosis, foliages observed are small and very rare. The features of these symptoms closely resemble those occured by the effects of heavy meetals. The amount of transparent radiation throughout the depth of soils from uranium radiation sources decreases exponentially. The mean contents in leaves of spotty and mosaik chlorotic plants, and soils were 1.36~1.53 and 5.3~7.4 ppm, respectively.

  • PDF

Morphological Factors and Cardiac Doses in Whole Breast Radiation for Left-sided Breast Cancer

  • Guan, Hui;Dong, Yuan-Li;Ding, Li-Jie;Zhang, Zi-Cheng;Huang, Wei;Liu, Cheng-Xin;Fu, Cheng-Rui;Zhu, Jian;Li, Hong-Sheng;Li, Miao-Miao;Li, Bao-Sheng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권7호
    • /
    • pp.2889-2894
    • /
    • 2015
  • Background: To investigate the impact of the breast size, shape, maximum heart depth (MDH), and chest wall hypotenuse (the distance connecting middle point of the sternum and the length of lung draw on the selected transverse CT slice) on the volumetric dose to heart with whole breast irradiation (WBI) of left-sided breast cancer patients. Materials and Methods: Fifty-three patients with left-sided breast cancer undergoing adjuvant intensity-modulated radiotherapy (IMRT) were enrolled in the study. The primary breast size and shape, MHD and DCWH (chest wall hypotenuse) were contoured on radiotherapy (RT) planning CT slices. The dose data of hearts were obtained from the dose-volume histograms (DVHs). Data were analyzed by one-way analysis of variance (ANOVA), Student's t-test and linear regression analysis. Results: Breast size was independent of heart dose, whereas breast shape, MHD and DCWH were correlated with heart dose. The shapes of breasts were divided into four types, as the flap type, hemisphere type, cone type and pendulous type with heart mean dose being $491.8{\pm}234.6cGy$, $752.7{\pm}219.0cGy$, $620.2{\pm}275.7cGy$, and $666.1{\pm}238.0cGy$, respectively. The flap type of breasts shows a strong statistically reduction in heart dose, compared to others (p=0.008 for V30 of heart). DCWH and MHD were found to be the most important parameters correlating with heart dose in WBI. Conclusions: More attention should be paid to the heart dose of non-flap type patients. The MHD was found to be the most important parameter to correlate with heart dose in tangential WBI, closely followed by the DCWH, which could help radiation oncologists and physicsts evaluate heart dose and design RT plan in advance.

On the Method of Rankine Source Distribution for Free Surface Flow Problem: Radiation Condition and Influence of Finite Distribution (자유표면문제해석(자유표면문제해석)을 위한 Rankine용출점(湧出點) 분포법(分布法) -방사조건(放射條件)과 유한분포(有限分布)의 영향-)

  • Chang-Sup,Lee;Seung-Il,Yang;Chang-Gu,Kang
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • 제19권2호
    • /
    • pp.13-18
    • /
    • 1982
  • The method of Rankine source distribution is emerging as a powerful yet simple alternative for the solution of complicated free surface problems. But it has been uncertain whether the radiation condition could be satisfied exactly by distributing the simple sources on the free surface only. In this paper, it is proved rigorously that the Rankine sources, whose intensities are varying sinusoidally along the axis satisfying the free surface boundary condition, generate the radiation waves both in the infinite and finite-depth flows. A formula is derived to give the upper and lower bounds of the errors in the induced velocity computation that will be introduced by truncating the extent of source distribution on the free surface. Since the truncation is inevitable in the numerical analysis, this formula may be used as a criterion to limit the position of the field points, where velocity computation is made, away from the truncation boundary. A typical analysis shows that the maximum error will be 3.4 percent of the exact induced velocity when the field point is on the free surface two wave lengths away from the truncation boundary.

  • PDF

Fast Neutron Beam Dosimetry (속중성자선의 선량분포에 관한 연구)

  • Lee Hyo Nam;Ji Young Hoon;Ji Kwang Soo;Lee Dong Han
    • The Journal of Korean Society for Radiation Therapy
    • /
    • 제9권1호
    • /
    • pp.71-81
    • /
    • 1997
  • I. Objective and Importance of the Project We have been using MC-50 cyclotron and NT-50 neutron therapy machine for treating cancer patients since 1986 at Korea Cancer Center Hospital. It is mandatory to measure accurately the dose distribution and the total absorbed dose of fast neutron for putting it to the clinical use. At present the methods of measurement of fast neutron are proposed largely by American Associations of Physicists in Medicine (Task Group 18), European Clinical Neutron Dosimetry Group, and International Commission on Radiation Units and Measurements. The complexity of measurement, however, induce the methodological differences between them. In our study, therefore, we tried to establish a unique technique of measurement by means of measuring the emitted doses and the dose distribution of fast neutron beam from neutron therapy machine, and to invent a standard method of measurement adequate to our situation. II. Scope and Contents of the Project For establishing a unique technique of measurement and inventing a standard method of measurement of fast neutron beam, 1. to grasp the physical characteristics of neutron therapy machine 2. to study the principles for measrement of fast neutron beam 3. to get the dose distribution (dose rate, percent-depth dose, flatness etc) throught the actual measurement 4. to compare our data with those being cited world-widely.

  • PDF

Development of a Virtual Frisch-Grid CZT Detector Based on the Array Structure

  • Kim, Younghak;Lee, Wonho
    • Journal of Radiation Protection and Research
    • /
    • 제45권1호
    • /
    • pp.35-44
    • /
    • 2020
  • Background: Cadmium zinc telluride (CZT) is a promising material because of a high detection efficiency, good energy resolution, and operability at room temperature. However, the cost of CZT dramatically increases as its size increases. In this study, to achieve a large effective volume with relatively low cost, an array structure comprised of individual virtual Frisch-grid CZT detectors was proposed. Materials and Methods: The prototype consisted of 2 × 2 CZTs, a holder, anode and cathode printed circuit boards (PCBs), and an application-specific integrated circuit (ASIC). CZTs were used and the non-contacting shielding electrode method was applied for virtual Frisch-grid effect. An ASIC was used, and the holder and the PCBs were fabricated. In the current system, because the CZTs formed a common cathode, a total of 5 channels were assigned for data processing. Results and Discussion: An experiment using 137Cs at room temperature was conducted for 10 minutes. Energy and timing information was acquired and the depth of interaction was calculated by the timing difference between the signals of both electrodes. Based on obtained three-dimensional position information, the energy correction was carried out, and as a result the energy spectra showed the improvements. In addition, a Compton image was reconstructed using the iterative method. Conclusion: The virtual Frisch-grid CZT detector based on the array structure was developed and the energy spectra and the Compton image were successfully acquired.

Prediction of Wave-Induced Current Using Time-Dependent Wave Model (쌍곡선형 파랑모형을 이용한 해빈류 예측)

  • 이정만;김재중
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 한국항해항만학회 1998년도 추계학술대회논문집:21세기에 대비한 지능형 통합항만관리
    • /
    • pp.189-199
    • /
    • 1998
  • Wave-induced current model is developed in our study and this model is composed with wave transform model and current model. Two types of wave model are used in our study, one is Copeland(1985) type which is applied in the offshore region and the other is Watanabe and Maruyama(1984) type which is applied in the surf zone. The depth-integrated and time-averaged governing equation of an unsteady nonlinear form is used in the wave induced current model. Lateral mising, radiation stresses, surface and bottom stresses are considered in our current model. Copeland's(1985) relult is used to calculate radiation stress and Berkmeir & Darlymple's(1976) is used as a surface friction formula. Numerical solutions are obtained by Leendertse scheme and compared with Noda's(1974) experimental results for the uniform slope coastal region test and Nishimura & Maruyama's(1985) experimental relults and numerical simulation results for the detached breakwater test. The results from our wave model show good agreement with the others and also show nonlinear effects around the detached breakwater. Wave induced current model is developed in this study and this model shows nonlinear effects around the detached breakwater and can be applied in the surf zone and also consider the friction stresses.

  • PDF

Clinical Applications of Microwave and Ultrasound in Hyperthermia: Preliminary Results (극초단파와 초음파온열치료에 의한 각종암의 임상치료)

  • Koh Kyoung Hwan;Park Young Hwan;Cho Chul Koo;Yoo Seong Yul
    • Radiation Oncology Journal
    • /
    • 제6권1호
    • /
    • pp.75-80
    • /
    • 1988
  • Twenty seven lesions of 25 patients with locally advanced malignant tumors were treated with combined hyperthermia introduced by microwave and ultrasound and radiotherapy. Most of all patients were failed with previous conventional therapeutic trial. Hyperthermia had been done immediately after radiotherapy, twice a week, $43^{\circ}C$ for one hour and radiotherapy had been done 5 fractions per week with fraction size of 2Gy upto 30 to 60Gy. Conclusions are as follows. 1. Total response rate (PR+PR) to thermoradiotherapy with microwave and ultrasound was $81\%$. 2. Tumor depth, minimum temperature of tumor center, number of heat fraction and radiation dose were statistically significant factors affecting response. 3. Hyperthermia with microwave and ultrasound can be used efficiently to control locally advanced malignant disease whether previously received near tolerance dose of radiotherapy or not.

  • PDF